Used Rockwell Hardness Test for sale (12,639)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
18,513 km
Temperature test chamber 280 liters
FeutronTPK 200 Typ: 3416/17 -70°C bis +180°C
Call
Condition: excellent (used), Feutron
Type: 3416/17
Temperature test chamber Air-cooled
Test chamber nominal volume: 280 liters
Dimensions:
Test chamber outside: width 1540 mm x height 2090 mm x depth 1240 mm
Fan motor and door dismantled: width 1540 mm x height 1940 mm x depth 925 mm
Test chamber: width 720 mm x height 690 mm x depth 560 mm
Door, clear width: width 720 mm x height 690 mm
Viewing window, heated: width 500 mm x height 600 mm
Installation dimensions of the temperature test chamber with doors open
Width 2340 mm x height 2090 mm x depth 2165 mm
Through-hole 2 pieces side wall, left ∅ 100 mm
Temperature range
-70°C to +180°C
Heating: 3.0 K /min
Cooling: 3.0 K /min
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Bjdpou E N Tisfx Ab Telr
Max. power requirement: 6.3 kW
Weight: 635 kg
Refrigerant: R507 / R23
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
Blodjv N Hc Eepfx Ab Tsr
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Climate test cell with humidity
Feutron3707/06 Temp. -40°C bis 150°C
Call
Condition: excellent (used), Here we offer a Feutron climate test cell.
Feutron climate test cell
Temperature
Temperature range: -40...90°C
Climatic range (without heat load) 10...85°C
Temperature difference,temporal during temperature operation ≤ ± 0.5 K/min.
Temperature difference,temporal at climatic operation ± 1,0... ± 1.5 K/min
Rate of change
Heating 2.0 on average K/min
Cooling 2,0 in average K/min
The IEC 1646 standard can be realized with testing, solar modules with max. 160kg weight and non-linear ramps.
(setpoint step change) can be realized
Drying
Air drying Condensation drying
Humidity
Humidification of air Steam humidification
Humidity range 10... 95 % r.h.
Humidity difference,temporal ≤ ± 3,0... ±5.0 %r.H.
Dew point range 8... 80,9 °C
Test room
Bedpfx Abeklv H Is Tolr
Test room volume 7.0m³
Dimensions
Test room dimensions width 1500 mm x height 2250 mm x depth 2000 mm
Revolving door DIN right heated,i,l.. width 900 mm x height 2100 mm
Viewing window, heated with darkening flap and lockable Width 500 mm x height 600 mm
Feed-through opening 2x in front side right ∅ 75 mm
Irradiation unit test room
Cut-out 4x in side panel left for SC 2500 850 x 700 mm each
Area to be irradiated when using SC 2500 1200 x 1200 mm
Intensity of radiation at 1.0 m distance from wall 1000 ± 10% W/m²
Lighting 1xhalogen lamp 200W
Refrigeration system Bitzer compressor semi-hermetic 2-stage,air-cooled
Condenser: split condenser (outdoor installation winter control)
Refrigerant R507 /R23
Temperature control system
Cooling brine medium Tyfocor / water
Mixing ratio 50/50
Density of cooling brine 1,072 kg/dm³
Filling quantity approx. 80dm³
Pyranometer Temperature range -40... 150°C
Max. Radiation absorption 4000 W/m²
Spectral range (50% points) 305... 2800nm
Sensitivity (norminal) 7 µV/W/m²
Power supply Test cell
Electrical mains connection 400V, 3/N/PE, AC, 50Hz
Connection type fixed connection
Max. simultaneous power requirement approx. 32.0 kW
Supply line fuse 3 x 63, Char C (A)
Power supply SolarConstant
Electrical mains connection 400V, 3/N/PE, AC, 50Hz
Connection type
Max. simultaneous power requirement approx. 30.0 kW
Supply line fuse 3 x 63, Char C (A)
Outer dimensions of the test cell complete with: Genset room/switch cabinet
and control cabinet for SolarConstant 2500
Outer dimensions of aggregate room width 3440 mm x height 2580 mm x depth 2950 mm
/switch cabinet width 2200 mm x height 1830 mm x depth 1100 mm
Outer dimensions of condenser, split width 900 mm x height 950 mm x depth 2000 mm
Mass of test cell, total approx. 2700 kg
Mass of condenser, empty 153 kg
Weight : 2700 Kg
Type: 3707/06
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
18,513 km
Temperature test chamber
FeutronTPK 200 Typ: 3416/17
Call
Condition: excellent (used), Feutron temperature test chamber
Here we offer a temperature test chamber.
Feutron temperature test chamber air-cooled
Nominal test chamber volume: 280 liters
dimensions
Bjdpfok Scxmex Ab Tjlr
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door dismantled: 1500 x 1940 x 925 mm
Test chamber: 720 x 690 x 560 mm
Door, clear width: 720 x 690 mm
Viewing window, heated: 500 x 600 mm
Temperature range
-70°C to +180°C
Heating: 4.0 K /min
Cooling: 0.6 K /min
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Max. power requirement: 6.3 kW
Weight: 600 kg
Type: 3416/17
Refrigerant: R507 / R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Test chamber for parametric test
S & A-55°C bis +200°C 4365A
Call
Condition: good (used), Here we offer you a S & A test chamber for parametric testing.
Temperature range
-55 ° C to 200 ° C (LCO2)
-65 ° C to 200 ° C (LN2)
Temperature change rate
15° C / min (Standard Option)
60° C / min (Fast Option)
Stability
± 0.2 ° C (including effects of mains voltage, ambient temperature between
between 15° and 45° C and aging)
Uniformity
Bjdpfx Ascnic Deb Tslr
± 1.0 ° C Max from -65 ° C to -55 ° C
± 0.5 ° C Max from -55 ° C to + 125 ° C
± 1,0 ° C Max from + 125 ° C to + 200 º C
Coolant: LCO2
Chamber can be controlled remotely via IEEE bus or
RS232C interface
Weight approx. 61 kg
Type: 4365A
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, details are reserved!)
Further questions we can answer gladly on the phone for you.
Discover more used machines
Listing
Borken
18,513 km
Temperature test chamber
CTST-40/600
Call
Condition: excellent (used), CTS Temperature Test Chamber
Here we offer you a CTS temperature test chamber.
Water cooled
Type series: T-40/600
Blodpohxyg Hofx Ab Tjr
Including metal struts to increase the floor load capacity
Test chamber volume: 600 liters
Test chamber dimensions:
Height approx. 850 mm, width approx. 850 mm, depth approx. 830 mm
Outer dimensions:
Height approx. 1900 mm, width approx. 1050 mm, depth, approx. 1850 mm
Temperature working range:
Temperature range -40 to +180°C
Temperature deviation ±0.1 to ±0.3 K temporally
heating speed: 2,5 K/min
cooling rate: 3 K/min
Electrical connection 400 V +6% -10%, 3/N, 50 Hz
rated power: approx. 5,5kW
rated current: approx. 8,5 A
Refrigerant: R404A
Weight: 550 Kg
Type: T-40/600 /011232
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Climate test chamber 280 liters
FeutronKPK 200 Typ: 3416/16 +5 °C bis +100 °C
Call
Condition: excellent (used), Here we offer a climatic test chamber.
Air cooled
Nominal test chamber volume: 280 liters
Dimensions
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door disassembled: 1500 x 1940 x 925 mm
test chamber: 720 x 690 x 560 mm
door, clear width: 720 x 690 mm
viewing window, heated: 500 x 600 mm
Temperature range
+5 to +100 C
heating: 4,0 K /min
Cooling: 0.6 K /min
Climate range +10 to +95 C
Humidity range: 10 to 95 % r.H.
Humidity difference, temporal: ≤ ± 3.0
Water connection humidifier: city water or distilled water 20l reservoir tank.
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Power requirement max : 6,3 kW
Weight : 500 Kg
Type : 3416/16
Refrigerant : R134a
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Blodpfx Abjiz Tqcj Tjr
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Stress test chamber
Espec (ThermoTec)TPC-212D
Call
Condition: excellent (used), Espec
Type: TPC-212D
Technical Specifications
Test Procedure: HAST – Highly Accelerated Stress Test
Model: Espec TPC-212D
Internal Volume: 2x (approx. 22 liters)
Internal Dimensions (ø x L mm): 2x 295 x 330 mm
Temperature Range: +105 °C to +142.9 °C
Humidity Range: 75% to 100% RH
Pressure Range: 0.02 to 0.196 MPa gauge (0 to 28 psig)
Power Supply: 220 V (±5%), 1-Phase, 50/60 Hz, 20 A
Special Features: Two chambers in one device
Notes:
Two chambers: Allow for simultaneous tests with different parameters or larger test volumes.
HAST test: Accelerated endurance test under high temperature and humidity
Bjdpewl D Aajfx Ab Telr
with overpressure for the qualification of electronic components.
Applications: Ideal for semiconductors, ICs, circuit boards, MEMS, etc.
Weight: 230 kg
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions over the phone.
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Bledpfjxmhycsx Ab Tor
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVC 4034 -40°C..+180°C
Call
Condition: good (used), Vötsch
Vötsch Climate Test Chamber, Air Cooled
Converted to refrigerant R-452a
Specifications for Temperature Tests:
Temperature range: -40°C to +180°C
Temporal tolerance: ±0.1 to ±0.5 K
Blodjxbrkhspfx Ab Tor
Spatial tolerance: ±0.5 to ±1.5 K
Temperature change rate according to IEC 60068-3-5:
Heating: 3.2 K/min.
Cooling: 3.5 K/min.
Specifications for Climate Tests:
Temperature range: -40°C to +180°C
Temporal tolerance: ±0.1 to ±0.3 K
Spatial tolerance: ±0.5 to ±1.0 K
Humidity range: 10% to 98% r.h.
Test chamber dimensions: Width 580 mm x Depth 765 mm x Height 750 mm
Housing dimensions: Width 780 mm x Depth 1758 mm x Height 1800 mm
Electrical connection:
Rated voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 4.9 kW
Rated current: 9 A
Refrigerant: R-452a
Test chamber volume: approx. 335 liters
Weight: approx. 515 kg net
Important information for you as a buyer!
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.
Listing
Borken
18,513 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Heraeus shock test chamber
Here we offer a shock test chamber.
Temperature shock test chamber water cooled
Two-chamber design
Warm chamber:
The temperature range of the warm chamber is from +50°C to +220°C.
Temperature deviation temporally in useful chamber center ± 1 K
Temperature deviation spatially ± 2 K
Temperature change rate
heating 11 K/min
cold chamber:
the cold chamber from -65°C to +70°C
Temperature deviation temporally in useful space center ± 1 K
temperature deviation spatially ± 2 K
Temperature change rate
heating 2 K/min
cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
Outer dimensions width 930mm depth 2115mm height 1970+mm
Rated power 10 kW
Rated current 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant R404A / R23
Bjdpfx Aoikvlxjb Tslr
Weight: 1000 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: HT 7012 S2
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Climate test chamber with humidity 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
Blodpswh Ttmofx Ab Ter
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Climate test chamber with humidity 34 liters
VötschVCL 7003 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VCL 7003
Air-cooled climatic test chamber
Test chamber capacity approx. 34 liters
Capacity for temperature tests:
Temperature range -70 to +180°C
Temperature deviation over time ±0.3 to ±1.0 K
Temperature homogeneity over space ±0.5 to ±2.0 K
Heating rate of change 4.0 K/min
Cooling rate of change 3.0 K/min
Heat compensation max. 550 W
Temperature calibration value +23°C and +80°C
Bedpfx Asv Tnd Sob Tolr
Capacity for climatic tests:
Temperature range +10 to +95°C
Humidity range 10 to 98%
Humidity deviation over time ±1 to ±3%
Temperature deviation over time ±0.3 to ±0.5 K
Spatial temperature homogeneity ±0.5 to ±1.5 K
Climate calibration values +23 °C / 50% RH and +95 °C / 50% RH
Test room dimensions: Width 350 mm, Depth 300 mm, Height 310 mm
External dimensions: Width 640 mm, Depth 750 mm, Height 1730 mm
Electrical connection:
1/N/PE AC 230 V ±10%, 50 Hz
Rated current 11.0 A
Rated power, max. 2.5 kW
Sound pressure level 59 dB(A)
Refrigerant: R-404 A / R23
Weight approx. 130 kg
For your safety, please note the following information as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Temperature test chamber
Heraeus VötschVTS 7033
Call
Condition: excellent (used), Heraeus Vötsch temperature test chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VTS 7033 water cooled
Temperature range: -70°C to +180°C
Temperature deviation temporal ± 0,5 K
Temperature deviation temporal ± 1,5 K
Heating speed: 7,5 K/min
Cooling rate: 6.5 K/min
Test chamber dimensions: Width 825 mm x depth 800 mm x height 870 mm
housing dimensions: 1080 mm x 1710 mm x 1950 mm
lateral passage 12cm and 13cm
voltage: 400V+6/-10%,3/N, 50Hz
nominal power 9,5 kW nominal current 22 A
refrigerant R404A / R23
approx. 570 liters weight: 580 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored by calibrated equipment.
Bsdelt U Avjpfx Ab Tslr
Type: VTS 7033
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Unit dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Temperature change rate:
Heating 4.0 K/min
Cooling 3.0 K/min
Max. heat compensation at +20°C 4500 watts
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Temperature homogeneity in space ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Bodpfoqwim Esx Ab Telr
Listing
Borken
18,513 km
Endurance test bench
EDAG Huf
Call
Condition: excellent (used), EDAG
EDAG Huf endurance test bench
Purpose:
This test bench is intended exclusively for testing parts that are capable of rotational and/or translational movement
as part of an endurance test and within the limits of the following technical data.
Technical data:
Dimensions: width 1565 mm x depth 615 mm x height 1655 mm
Weight approx. 450 kg
Operating voltage 400V /50Hz
Control voltage 5, 24
Bsdevx S Apspfx Ab Tslr
Provisional fuse 16 A
Test device:
Maximum stroke 194 mm
Maximum axial force 500 N
Maximum moment 5 Nm
Break-out force (manually operated slide) 15 N
Displacement force (manually operated slide) 10 N
Other equipment Ρ4, 24" TFT monitor (1900 X 1080)
Operating system Windows XP
Measurement and control software LabVIEW 2011
PC plug-in cards 1 card, NI PCI-6251,1 card, N1 PCI-7044
Drawer 500 mm (fully extended with automatic closing) Additional load 500 N
Drawer cabinet, lockable 3 drawers
The teach-in endurance test bench is a device for carrying out endurance tests
On test objects that can rotate and/or move translationally, e.g. cylinders
Locks, door handles, key functions.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Emission test chamber
WEISSWT 5,1'/ + 18-45
Call
Condition: excellent (used), Weiss
Here we offer a Weiss emission test chamber.
Mini - SHED for Diurnal Loss Measurements
Test chamber dimensions: Width 1600 mm x Depth 2140 mm x Height 2150 (Usable 1600) mm.
Housing dimensions: Width 1760 mm x depth 3100 mm x heights 2790 mm
Max. floor load 250 kg
Operating range +18 °C ...+45 °C, (at higher temperatures SHED operation is only possible without Tedlar bag)
Temperature range +18 °C ...+45 °C
Temperature constancy ≤ ±1 K (temporal)
Temperature change rate, (heating and cooling) approx. 0.5 K/min., without test material
Duct connection (air inlet and outlet) ∅ 80 mm, in chamber rear wall
Shut-off valve, gas-tight (air inlet and outlet) ∅ 80 mm, gas-tight, pneumatic operation Delivery limit: connection flange of shut-off valve
Cooling water consumption approx. 0.8 m3/h
Voltage: 230/400 V; 3 PH + N + PE; 50 Hz
Rated power: 4,1 kW Rated current: 14,0A
Weight: approx. 2500 kg
type: WT 5,1'/ + 18-45
Condition: used / used
Sale ex location
Bodomfny Ispfx Ab Tolr
Scope of supply: (Only the Weiss emission test chamber WT 5,1'/ + 18-45 Mini-SHED)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS³ 7018-5
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7018-5
Water-cooled
Test chamber dimensions: Width 580 mm x depth 450 mm x height 750 mm
Housing dimensions: Width 900 mm x depth 1550 mm x height 1850 mm
Temperature test:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Bjdpfxsn E Sk Eo Ab Tslr
Temperature change rate: cooling 7.5 K/min
Test chamber volume: 190 liters
Nominal voltage: 400V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber -70°C to +180°C
VötschVTS 7027-15
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7027-15
Vötsch Temperature Test Chamber, Water-Cooled
Temperature Range: -70°C to +180°C
Temperature Rate of Change:
Temperature Deviation Temporarily ± 0.3 to ± 0.8 K
Blodpfx Ajwl Argob Tjr
Temperature Deviation Spatially ± 0.5 to ± 2.0 K
Cooling Rate of Change: 18.0 °C
Heating Rate of Change: 17.0 °C
Test Chamber Dimensions: Width 580 x Depth 620 x Height 950 mm
External Dimensions: Width 870 x Depth 1895 x Height 1775 mm
Side Ports: 1 x 60 mm Ø and 2 x 120 mm Ø
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power 16 kW
Rated current 31 A
Refrigerant R452A / R23
Approx. 270 liters
Weight: 835 kg
For your safety, the following information is provided as a buyer!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Fuel vapor loading test bench
SIGAGS-517-400
Call
Condition: good (used), Siga
Type: GS-517-400
Blodpfxju Aa A As Ab Ter
External dimensions LxDxH 4960 x 2500 x 2400 mm.
Complete system is calibrated according to DAKKS and
and therefore approved for approval-relevant tests
Butane loading speed
- infinitely variable from 5 g/h to 77 g/h
Loading speed fuel
- infinitely variable from 5 g/h to 100 g/h
Fuel temperature control
- infinitely variable from 20°C to 50°C
Fuel quantity selectable
- from 0 l to 8 l
Selectable breakthrough criterion
- from 1g to 10g
Purge air flow temperature
- Infinitely variable from 25°C to 30°C
Precision scales for test piece and reference AKF
- Measuring range up to 6 kg, 0.1 8 resolution
Purging vacuum
- Infinitely variable from 0 hPa to 30 hPa
Rinsing air flow
- infinitely variable from 1 l /min to 60 l/min
Humidity purge air flow
- infinitely variable from 10% rH to 85% rH
Number of cycles from 1 to 999 (load/purge)
Condition: gebraucht / used
Sale ex location!
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Bjdpfx Abeun Ruls Tjlr
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
18,513 km
Climate test chamber 900 liters
CTSCS-70/900 -70...+180°C
Call
Condition: used, Type: CS-70/900
CTS Climate Test Chamber with Humidity, water-cooled
Bjdpoxb Dm Isfx Ab Telr
(converted to R-452a refrigerant)
Temperature range: -70°C to +180°C
Humidity range: 10–98% RH
Test chamber internal dimensions: Height approx. 870 mm / Width approx. 1000 mm / Depth approx. 1000 mm
External dimensions: Height approx. 1950 mm / Width approx. 1200 mm / Depth approx. 2220 mm
Control cabinet dimensions: Height approx. 2100 mm / Width approx. 800 mm / Depth approx. 400 mm
Test chamber volume: 900 liters
Refrigerant: R-452a / R23
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Connected load: 21.2 kW, Rated current: 35.7 A
Chamber weight: 900 kg
Control cabinet weight: 150 kg
Important safety information for buyers:
The following steps are carried out on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilled with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors reserved!)
For any further questions, please contact us by phone.
Listing
Borken
18,513 km
Climatic test chamber shaker chamber 2160 liters
WeissWK3-2200/40/5/V -40°C bis +180°C
Call
Condition: excellent (used), Weiss
Type: WK3-2200/40/5/V
Weiss Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -40°C to +180°C
Temperature change rates:
Heating: 6.0 K/min
Cooling: 11.5 K/min
Temperature deviation:
Temporal ± 0.8 K
Spatial ± 2.0 K
Heat compensation max. 8000 W
Bledpfx Abow I Rxrs Tor
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Dew point temperature range: +4°C to +94°C with closed floor element
Humidity range: 10 to 95% rH
Temperature deviation (temporal): ± 0.3 K
Humidity deviation (temporal): ± 3% rH
Temperature uniformity:
Spatial ± 1.0 K
Heat compensation max.: 500 W
Test chamber volume: 2,160 liters
Test chamber dimensions: Height 1,115 mm, Width 1,400 mm, Depth 1,400 mm
External dimensions (lowered): Height 2,318 mm, Width 1,860 mm, Depth 3,658 mm
External dimensions above shaker: Height 2,710 mm
External dimensions max. stroke height: 3,038 mm
Exchangeable floor dimensions: Width 1,600 mm, Depth 1,504 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V +10% 50Hz
Rated power: 38.0 kW
Rated current: 63.0 A
Customer-side fuse: 80 A slow-blow
Refrigerant: R 404A
Weight: approx. 2,100 kg
Important information for your safety as a buyer:
The following points will be carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with refrigerant compliant with legal regulations
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
18,513 km
Assemblies / Test cabinet
VötschVT 3050 -30°C / +100°C 500 Liter
Call
Condition: excellent (used), Vötsch
Type: VT 3050
Modules / Test Chamber Temperature Chamber
Air-cooled
Test chamber capacity 500 litres
Temperature range -30°C / +100°C
Temporal temperature fluctuation K ±0.5
Spatial temperature fluctuation K ±1.5
Temperature gradient K 3
Change rate
Heating K/min 2.0
Cooling K/min 1.4
Heat compensation max. W 650
Calibration values +23°C +80°C
Test chamber dimensions Width 710 mm Depth 590 mm Height 1250 mm
External dimensions Width 940 mm Depth 1030 mm Height 1955 mm
Bodpfx Abjw S E N Ts Tjlr
Sound pressure level db(A)
Listing
Borken
18,513 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-10 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-10
Vötsch Climate Test Chamber, Water-cooled
Bljdpfxowynmxs Ab Tor
Specifications for Temperature Testing:
- Temperature range: -70°C to +180°C
- Temporal temperature deviation at the center of the usable test volume: ±0.3 to ±0.8 K
- Spatial temperature deviation: ±0.5 to ±2 K
- Temperature gradient: 1 to 4 K
- Temperature change rate:
- Heating: 11 K/min
- Cooling: 10.5 K/min
Specifications for Climatic Testing:
- Temperature range: +10°C to +95°C
- Humidity range: 10 to 98% RH
- Temporal temperature deviation at the center of the usable test volume: ±0.2 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1 K
- Temperature gradient: 1 to 2 K
- Temporal humidity fluctuation at the center of the usable test volume: ±1 to ±3 % RH
Technical Data:
- External dimensions (with hinges and door lock):
- Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
- External dimensions (without hinges and door lock):
- Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
- Internal chamber dimensions:
- Height: 950 mm, Width: 1100 mm, Depth: 950 mm
- Test chamber volume: approx. 1300 liters
Feedthroughs:
- The chamber is equipped with feedthroughs on both the right and left sides, allowing measurement cables and test devices to be routed into the test space.
- 1 x R1 NW 125 mm
- 1 x L1 NW 50 mm
Test Chamber Lighting:
- Halogen bulb 24 V, 50 W
Electrical specifications:
- 3/N/PE AC 400V ±10% 50Hz
- Rated power: 34.0 kW
- Rated current: 50.0 A
- Fuse (to be provided on site): 100 A slow-blow
- Max. heat emission to environment: 2.2 kW
Permissible Test Specimen Weight:
- Total load on grate supports: 100 kg
- Chamber floor: 150 kg; Inserted rack: 50 kg
Refrigerants:
- R 404A / R 23
Weight: 1600 kg
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in technical data and information!)
For further questions, please feel free to contact us by phone.
We make it easier for you to find: "rockwell hardness test"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Rockwell Hardness Test (12,639)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month















































































































































































































