Used Channel for sale (962)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
18,513 km
Flame photometer
A.KRÜSSFP8400
Call
Year of construction: 2019, condition: as good as new (ex-display), functionality: fully functional, KRÜSS
Type: FP8400
Remarks: (Year of manufacture 2019)
The device has never been put into operation, is in mint condition
and is in its original packaging.
Description:
The flame photometers from A.KRÜSS are used to determine the concentration of alkali and alkaline earth elements in aqueous solutions.
The devices are a simple and particularly cost-effective alternative to analysis techniques such as ICP or AAS.
Flame photometers are particularly suitable for the quantitative determination of alkali metals such as sodium (Na), potassium (K) and lithium (Li) and alkaline earth metals such as calcium (Ca).
The measurement for these elements is carried out simultaneously in one step.
Through consistent modernization of the flame photometers and a special focus on safety-related concepts, completely new fields of application are opening up for many cost-sensitive customer groups - from automated incoming goods inspection to the qualification of FFP masks according to DIN 149. Low operating costs are one of AES's main strengths, and the technology of the FP8000 series also scores with high determination accuracy. Measuring food samples Quality assessment of high-purity glasses and vials for pharmaceutical packaging Concrete classification Analysis of infusion solutions. Flame photometer laboratory version with manual sample feed, 4 measuring channels, measuring methods freely configurable, additional channel for flame monitoring. Measuring ranges for undiluted samples:
0.01 mg/l to 4500 mg/l sodium
0.01 mg/l to 4500 mg/l potassium
0.01 mg/l to 4500 mg/l lithium
0.50 mg/l to 4500 mg/l calcium
Resolution:
0.001 mg/l for all elements
Crodpsvy Uytsfx Ab Tjk
Accuracy: +/-1% with appropriate quality of the standards
Precision:
Listing
Wadersloh
18,457 km
Drum screen
SieboTecSiebo 5000
Call
Year of construction: 2022, operating hours: 2,300 h, condition: excellent (used), functionality: fully functional, For sale: Siebo 5000, year of manufacture 2022, approx. 2,300 operating hours. CAT C3.6 55 kW EU Stage 5 without AdBlue, 40mm drum, hydraulically foldable hopper grid, 8-channel radio control system, road-approved (de-registered).
Credpfxsxyuuao Ab Tsk
Listing
Obertraubling
18,411 km
Minibus
Mercedes-BenzVito Tourer 119 CDI Edition lang Klima S
Call
Condition: good (used), functionality: fully functional, mileage: 125,753 km, power: 140 kW (190.35 HP), fuel type: diesel, gearing type: automatic, wheelbase: 3,200 mm, overall weight: 3,100 kg, first registration: 10/2021, next inspection (TÜV): 09/2026, emission class: euro6, color: grey, number of seats: 8, number of previous owners: 1, Year of construction: 2021, Equipment: ABS, additional headlights, air conditioning, airbag, all-season tires, car registration, central locking, cruise control, electronic stability program (ESP), fog lights, immobilizer system, navigation system, onboard computer, parking heater, parking sensors, power assisted steering, seat heater, sliding door, soot filter, 7831 Paint finish graphite grey metallic dark MB 7831
BA3 Active Brake Assist
BH1 Hold Function
CF7 Comfort Suspension
CL3 Leather Steering Wheel
CL4 Multifunction Steering Wheel with Trip Computer
CM2 Bumpers and Attachments Painted in Body Colour
CN1 Sill Exterior
CU4 Aerodynamics Package
D12 Roof Rail / Luggage Rack
E07 Hill Start Assist
E1D Digital Radio (DAB)
E57 Trailer Socket Wiring
EA4 Audio 40
EL9 2-way Speakers Front and Rear
ES2 12V Socket in Boot/Cargo Area
ET4 Active Distance Assist DISTRONIC
EY2 Pre-installation for Live Traffic Information
JK3 Instrument Cluster with Pixel Matrix Display
JP1 PRE-SAFE®
JP4 Lane Package
JW5 Lane Keeping Assist
JW8 Attention Assist
JX2 Service Interval 40,000 km
KB5 Main Fuel Tank 70 Litres
KP7 SCR Emission Control Generation 4
L Left-Hand Drive
LA2 Headlight Assist
LC4 Comfort Roof Control Unit
LC8 Surround Lighting at Tailgate
LD9 Rear Compartment Interior Lighting
LE1 Adaptive Brake Light
LG2 LED Intelligent Light System
LG4 LED Tail, Brake and Indicator Lights
LG8 High Beam Assist Plus
LX5 Europe Version
M3E Electric Suction Fan, Power Level 5
M60 Alternator 14 V/250 A
MG9 Alternator Management
MJ8 ECO Start/Stop Function
MO6 Emission Standard Euro 6D M/N1 Gr. II
MU6 Engine OM654 DE 20 LA 140 kW (190 HP)
MX0 BlueEFFICIENCY Package
EZ5 Park Package
EZ8 PARKTRONIC
F48 Heated Washer System
F64 Electrically Folding Exterior Mirrors
F68 Heated and Electrically Adjustable Exterior Mirrors
F72 Automatically Dimming Exterior and Interior Mirrors
FK2 Chrome Radiator Grille
FP2 Mirror Package Vito
FP4 Interior Chrome Package
FR8 Reversing Camera
G43 9G-Tronic Automatic Transmission
H00 Warm/Cool Air Channel to Passenger Compartment
H12 Additional Hot Water Heater
H15 Heated Passenger Seat
H16 Heated Driver Seat
H20 All-round Heat-Insulating Glass
HH9 Semi-Automatic TEMPMATIC Climate Control
HY1 Remote Control for Additional Hot Water Heater
HZ0 Electric Auxiliary Heater
HZ7 Semi-Automatic TEMPMATIC Climate Control, Rear Compartment
IL5 Left-Hand Drive
IL6 Metallic Paint
IN2 Wheelbase 3200 mm, Long Overhang
JA7 Blind Spot Assist
JF1 Rain Sensor
JP4 Lane Package
JW5 Lane Keeping Assist
JW8 Attention Assist
JX2 Service Interval 40,000 km
KB5 Main Fuel Tank 70 Litres
LA2 Headlight Assist
LE1 Adaptive Brake Light
LG2 LED Intelligent Light System
LG4 LED Tail, Brake and Indicator Lights
LG8 High Beam Assist Plus
MG9 Alternator Management
MJ8 ECO Start/Stop Function
MO6 Emission Standard Euro 6D M/N1 Gr. II
MU6 Engine OM654 DE 20 LA 140 kW (190 HP)
MX0 BlueEFFICIENCY Package
RY2 Wireless Tyre Pressure Monitoring Front & Rear Axles
SA6 Passenger Airbag
SB1 Comfort Driver Seat
Credsxwy Dnopfx Ab Tek
SB2 Comfort Passenger Seat
SE5 Lumbar Support for Driver's Seat
T19 Left Sliding Door
US4 3-seater Comfort Bench 1st Row, Outer Seat Foldable
US5 3-seater Comfort Bench 2nd Row with Foldable Outer Seat
V23 High-Class Interior Trim
VL2 Velour Floor Mats
VU9 Black Artificial Leather
W16 Fixed Front Left Window in Side Panel/Sliding Door
W17 Fixed Front Right Window in Side Panel/Sliding Door
W32 Electrically Operated Sliding Passenger Compartment Windows
W65 Tailgate
W70 Privacy Glass Rear, Black Glass
W78 Rear Window in Tailgate/Rear Door with Wiping and Washing System
Z2S Sport Line
Z42 Registered as Passenger Car
Z91 Special Model Tourer Edition
ZM4 Passenger Van
ZQ8 Tourer PRO

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Geisenheim
18,603 km
Gea Baseline Plattenwärmetauscher
GEAM10-MBASE
Call
Condition: used, The Alfa Laval M10-MBASE is a compact and highly efficient plate heat exchanger, designed for demanding applications in the beverage and food industry, chemical processing, and general heating and cooling duties.
Technical Specifications
Type: M10-MBASE
Heat transfer area: 2.6 m²
Plate material: Stainless steel Alloy 316, thickness 0.50 mm
Gasket material: NBRFF Clip-On (Nitrile rubber)
Plate pack thickness: 63 mm
Total weight: 232 kg
Total volume: 13 liters
Dimensions: Height 672 mm, width 618 mm, depth 530 mm
Connection standard: DIN NW100
Bolts: M20
Expandable: up to 17 additional plates
Operating Data
Design pressure: 10 bar
Test pressure: 14.3 bar
Design temperature: up to 120 °C
Minimum temperature: 0 °C
Typical flow examples (according to datasheet):
Wine: 2,000 L/h (heating 12 → 17 °C, Δp = 47 kPa)
Hot water: 2,000 L/h (cooling 30 → 24 °C, Δp = 22 kPa)
Fruit juice: 240 L/h (heating 21 → 75 °C with 90 °C hot water, Δp ≈ 40–50 kPa)
Design Features
Plates with parallel flow channels ensure high efficiency and low pressure drop.
Clip-on gaskets for easy maintenance and cleaning.
Robust frame and pressure plate construction with M20 tightening bolts (length 360 mm).
Flexible capacity expansion, up to 17 additional plates can be installed.
Crjdpfxjxytv No Ab Tjk
User-friendly assembly with clear A/B plate markings.
Typical Applications
Beverage pasteurization (e.g., wine, juice, beer)
Hot water and cooling water circuits
CIP cleaning systems
General process heat transfer in industrial applications
Listing
Wrocław
18,001 km
Injection molding machine
EngelVictory 310-60 Electric
Condition: good (used), Injection molding machine Engel Victory 310-60 Electric CC200
Crjderg Hh Nopfx Ab Tjk
Year of manufacture: 2006
Clamping unit type: Fully hydraulic
Clamping type: Columnless
Clamping force: 600 kN
Plate dimensions (table dimensions): 720 mm
Distance between columns: 450 mm
Mold height: 600 mm
Opening stroke: 900 mm
Ejector stroke: 115 mm
Ejector force: 125 mm
Moving plate centering (D): 125 mm
Fixed plate centering (D): 4,70 m
Threaded holes on plates: 5700 kg
Maximum mold weight: 1,40 m
Dimensions (W x H): 2,70 m
Machine weight: 5700 KG
Heating channels: 9
Nozzle clamping force: 160 mm
Nozzle stroke: 360 1/min
Pump drive power: 13 kW
Heating capacity: 9 kW
Standard voltage: 400 V 50 Hz
Oil capacity: 185 l
Auger diameter: 35 mm
Injection volume: 154 cm³
Injection pressure: 2400 bar
Screw pitch: 24 mm
Screw speed: 155 cm³/sec.
Plasticization capacity: 40.6
Air injection speed: 290
Additional equipment:
Monitor text in German
CEE 16A plug socket
CEE 16A plug socket
Hydraulic core 2x
Air fan 1x
Water-cooled machine battery
Machine without material tank
Leveling elements
Standard interface/Euromap 12
Schuko 10A plug socket
Schuko 10A plug socket
Listing
Karlstein am Main
18,540 km
Car transporter trailer
FitzelDUO 35-21/83 Tridem Seilwinde
Call
Condition: used, functionality: fully functional, empty load weight: 1,130 kg, maximum load weight: 2,370 kg, overall weight: 3,500 kg, axle configuration: 3 axles, first registration: 03/2025, next inspection (TÜV): 09/2027, loading space length: 8,300 mm, loading space width: 2,100 mm, tire size: 195/55 R 10 C, tire condition: 100 %, color: silver, Object number #30618
Full aluminum
Alloy wheels
Tires 195/55 R 10 C approx. 100%
Knott axles
Body length (inside): 8,300 x 2,100 mm
Electric cable winch
Synthetic fiber winch rope
2-channel remote control
Electric spare wheel holder
Rear support legs
Lashing points every 80 mm
4x aluminum wheel chock brackets
Loading height 580 mm
Ramp angle 9°
2 loading ramps
2x toolboxes
Codpfx Aexyp Smeb Tork
Leasing or financing available upon request!!
Listing
Borken
18,513 km
Climate test chamber 1000 liters
CTSC-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Climate test chamber C-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Humidity range: 5 to 95% RH
Dew point range: 5°C to +78°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type C -55/1000/Li
1) C means: climate
2) -55 means: lower temperature -55 °C
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Csdpfxsva Hi Hj Ab Terk
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
Climate tests:
Temperature range +5 °C to +95 °C
Humidity range 5% to 95% rel. humidity
Dew point range +5°C to 78°C
Temperature deviation ≤ ±1.0 K in time
Humidity deviation ≤ ±3.0% relative humidity over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may influence the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Shaker vibration vibration Exciter
RMSSW 3009 mit Seitenkanalgebbläse
Call
Condition: excellent (used), Here we offer you a RMS vibration vibration exciter SW 3009 with side channel blower SKP49033-01/06Type: SW 3009Condition: used / usedScope of supply: (See picture)(Changes and errors in the technical data, specifications are reserved!)We are happy to answer further questions for you on the phone.
Cjdpfjd Talgjx Ab Terk
Listing
Borken
18,513 km
Intelligent data loggers
G.i.N.GL5350 GL5350-8H-1R3L
Call
Condition: excellent (used), G.i.N.
Type: GL5350 GL5350-8H-1R3L
G.i.N. Intelligent data logger GL5350
Performance meets intelligence
Future generations of vehicles will be increasingly equipped with intelligent
driver assistance systems, complex multimedia components and
and systems for autonomous driving. These complex,
networked technologies provide ever larger amounts of data, which makes
and more complex during the development phase.
In order to shorten the test drives, reduce their number
and still meet the test requirements of all departments,
the advantages of an intelligent and powerful data logger
data logger such as the GL5300 series come into play.
The GL5300 series covers the time-synchronous recording of LIN/
CAN & CAN FD bus systems via FlexRay networks through to Ether-
networks (TCP/UDP/DLT/ADB and Ethernet raw logging).
This series also offers the connection of up to 8 cameras
and up to 5 GLX504 for a further 20 CAN FD channels with SIC transceiver
and up to 3 GL5450 for synchronous recording of up to 60
100-base T1 (30 taps) and up to 18 1000-base T1 routes (9 taps).
Residual bus simulation
Classifier
Gateway
CCP/XCP on CAN, XCP on CAN FD, XCP on FLexray, XCP on Ethernet
Transmission of any freely configurable messages
Selective recording (extensive triger and filter conditions)
Data transmission via LAN/WLAN, USB and mobile radio
Operation via menu control
Technical data:
GL5300 Configuration
GL5350-8H-1R3L
CAN interfaces
CAN 2.0 16
CAN FD 4
LIN interfaces 5
RS-232 interfaces 7
Analog inputs 10 Bit 4
Operating voltage +7 V ... +50 V
Power consumption at 12 V: typ. 10.3 W
Current consumption at 12 V:
in sleep mode < 2 mA
in half-sleep mode typ. 180 mA
Codpfx Ast R R Uwob Terk
in operation typ. 860 mA
Operating temperature range -40 °C... +70 °C
Housing:
Material side profiles: Al Mg3
Cover: EN AW-6060 (AlMgSiO,5) T66
Trim strip: ABS
Dimensions (LxWxH) 212x 290 x 80
Weight ~ 3500g
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Climatic test chamber 350 liters Ex/l
CTSC-40/350 Ex/l -40°C /+180°C
Call
Condition: excellent (used), CTS
Type: C-40/350 Ex/l
Climate Test Chamber, Water-Cooled
ATEX Zone 1
The Ex/l designation indicates that this climate test chamber is suitable for use in hazardous areas classified as Zone 1. This means it is designed for environments where explosive atmospheres may occur. Such equipment is specially constructed and tested to ensure safety in these conditions.
Temperature Testing:
Temperature range: -40°C to +180°C
Temperature deviation: ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5:
Heating: 3.5 K/min
Cooling: 4 K/min
Heat compensation:
approx. 3500 W at +20°C
approx. 2000 W at -20°C
Climate Testing:
Temperature range: +10°C to +90°C
Humidity range: 10% to 95% relative humidity
Dew point range: +5°C to 78°C
Temperature deviation: ≤ 1.0 K over time
Humidity deviation: ≤ ±3.0% r.h. over time
The technical data refer to an ambient temperature of +25°C, nominal voltage of 400V, without test specimen, without heat compensation, and without additional equipment. Options may affect performance data.
Technical Design:
Cooling unit:
water-cooled, low-noise, fully hermetic, infinitely variable power adjustment via electronic monitoring and control system, environmentally friendly refrigerant R404A
Test chamber: Floor load capacity 150 kg/m²
Rack: Stainless steel,
support surface 620 x 600 mm
Load per rack max. 35 kg
Total load with maximum rack configuration 100 kg
Credpfx Aewvr H Uob Tsk
Control system:
32-bit controller
LCD operating panel
Digital display of setpoint and actual values
Numeric input of setpoints
Plain text fault messages
RS 232 interface
Ethernet interface
Free switching channels for user-side test item control
Dimensions:
Test volume: 350 liters
Internal dimensions: Height 750 mm × Width 650 mm × Depth 720 mm
External dimensions: Height 1800 mm × Width 850 mm × Depth 1640 mm
Operating Data:
Electrical connection: 400V +6/-10%, 3/N, 50 Hz
Nominal power: 7.15 kW
Nominal current: 14.3 A
Protection class: IP 54
Sound pressure level
Listing
Borken
18,513 km
Measuring system
HeinzingerERS 600-500/160 2 Kanäle
Call
Condition: good (used), Heinzinger
Type: ERS 600-500/160
Description: Battery module tester
Highly dynamic test bench energy system
Bidirectional DC power supply with active energy recovery, liquid-cooled
Voltage [max]: 20 - 600 V adjustable
Current per channel [max]: ± 500 A adjustable
System power [max]: ± 250,000 W
Mains connection (3/N/PE): 3x400V ±10% 47 ... 63Hz
Software: Battery simulation software for load change-optimized control
Dimensions (W/H/D): 2400/2330/800 mm
Condition: used
Scope of delivery: (See picture)
Credpeq Nzwhjfx Ab Tjk
(Changes and errors in the technical data, information are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Temperature test chamber 1000 liters
CTST-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Temperature test chamber T-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type T -55/1000/Li
1) T means: temperature
2) -55 means: lower temperature -55 °C
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
Cjdpfxevba Ras Ab Tsrk
approx. 2200 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may affect the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Power supply
TDK-LambdaGEN10-240
Call
Condition: good (used), TDK-Lambda
Type: GEN10-240
TDK-Lambda GEN10-240 | Power supply unit, DC, 1 channel, 2 U, 10V/240A, 2,400W, RS232, RS485
in a 19 inch housing
Technical data:
Manufacturer TDK-LAMBDA
Power supply unit type Programmable laboratory power supply unit
Used display type LED x2
Number of channels 1
Output voltage 0...10V DC
Output current 0...240A
Max. Power 2,4kW
Rack mounting 19"
Output voltage solution 1.2mV
Output current solution 28.8mA
Ripple and noise of the voltage (regulated) ≤8Vrms, ≤60Vpp
Input connection type terminal block
Manufacturer series GEN
Operating temperature 0...50°C
Dimensions (width x height x depth) 423x43.6x432.8mm
Display parameters 4 digits
Software LabVIEW
Condition: gebraucht / used
Scope of delivery: (see picture)
Credpfxsuv E Auj Ab Tjk
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Sensor for multilayer thickness measurement
Niroxmulti-Thick-MS1-CH
Call
Condition: used, Nirox
Sensor Nirox multi-Thick-MS1-CH1
Codew Elmyspfx Ab Terk
Nirox multi-Thick-MS1-CH1 – Sensor for Multi-Layer Thickness Measurement
For sale is a high-quality optical sensor of the type Nirox multi-Thick-MS1-CH1, designed for precise, non-contact measurement of multi-layer materials such as plastic films, composites, or coated substrates. This sensor system is ideally suited for quality control in the plastics or packaging industries.
Technical highlights:
Model: multi-Thick-MS1-CH1
Manufacturer: Nirox s.r.l. (Italy)
Function: Optical precision sensor for micrometer-accurate layer thickness measurement
Measuring method: A-Scan / optical interference analysis
Channel: 1 (CH1)
Fields of application: Inline measurement in production lines or for laboratory use
Typical materials: Multi-layer films, coated glass, technical laminates
Condition: used
Scope of delivery: (see image)
Sensor multi-Thick-MS1-CH1
Connection cable
(Subject to changes and errors in technical data. All information is provided without guarantee!)
If you have any further questions, we are happy to assist you by phone.
Listing
Borken
18,513 km
Test table
Chroma Batteriepack-TesterATE 17020
Call
Condition: used, Chroma
Type: ATE 17020
The Chroma 17020 is a highly professional, modular test system for lithium-ion & other battery pack qualification.
Particularly strong in:
Cedpfx Aswwrxaeb Tsrk
- Lifetime testing, BMS verification, and validation of complex charging cycles
- High energy recovery – up to 85% efficiency
- Flexible expansion through numerous channels or higher current ranges
- Enterprise deployment with extensive safety features & data persistence
Technical data – Chroma ATE 17020 PTS
Feature Specification
Model: Chroma ATE 17020 PTS
System type: Regenerative battery pack test system (charge/discharge test)
Channel output: 600 W to 60 kW (modular and scalable)
Total output: Up to 600 kW (depending on configuration)
Voltage range: 20 V / 60 V / 100 V / 200 V / 500 V
Current per channel: Depending on module: from a few amps up to >300 A per channel
Parallel operation: Yes, for higher current up to 2,600 A
Current and voltage accuracy: ±(0.05% of reading + 0.05% of range)
Power accuracy: ±0.1%
Transition time (charge/discharge): < 50 ms
Sampling rate (measured data): up to 50 kHz (with BatteryPro)
Data logging: Cyclic, 10 μs – 1 s / memory for 60 min power failure
Test modes: CC, CV, CP, CC-CV, DCIR, pulse, drive cycle, dynamic profiles
Number of channels: Up to 60 channels (expandable)
Communication: CAN, S-Bus, Ethernet, USB
Software: Chroma BatteryPro (test programming, real-time monitoring)
Protection functions: OVP, UVP, OCP, UCP, OTP, reverse polarity, wire loss, delta V/I, etc.
Energy recovery: Yes – up to 85% energy efficiency, grid-friendly (THD < 5%)
Cooling: Fan cooling, low waste heat due to energy recuperation
Temperature monitoring: Optionally integrable, range 0–90°C ±2°C
Dimensions & weight: Depending on configuration (e.g. 19″ rack, approx. 300 kg)
Mains connection: 3-phase, 400 V AC (depending on model)
Applications: E-mobility, battery development, quality assurance, cell research
Weight: approx. 455 kg
Condition: used
Scope of delivery: (See picture)
(Specifications and technical data are subject to change and errors excepted!)
If you have further questions, we are happy to assist you by phone.
Listing
Borken
18,513 km
Temperature test chamber 600 liters
CTST-70/600/S 70°C bis 180°C
Call
Condition: good (used), CTS
Type: T-70/600/S
Temperature test chamber water-cooled
Refrigerant: Converted to R-452A
Control:
- 32 bit controller
- LCD control panel
- Digital display of setpoints and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at + 0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions Height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions Height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Nominal current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R-452A / R23
Weight: 700 kg
Cjdpfx Absvitmds Tsrk
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber 600 liters
CTST-70/600/S -70°C bis 180°C
Call
Condition: excellent (used), CTS
Type: T-70/600/S
Water-cooled temperature test chamber
Control system:
- 32 bit controller
- LCD control panel
Cedpfx Absu U Ixms Tsrk
- Digital display of set and actual values
- Numerical input of setpoints
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Technical performance data
Temperature tests:
Temperature range -70 °C to +180 °C
Temperature deviation ±0.1 to ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat radiation
approx. 2500 W at +20°C
approx. 2500 W at + 0°C
approx. 1800 W at -40°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions Height, approx. 850 mm, width, approx. 850 mm, depth, approx. 830 mm
External dimensions Height, approx. 1900 mm, width, approx. 1120 mm, depth, approx. 1875 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 8.8 kW
Nominal current 14.8 A
Protection class IP 22
Weight approx. 700 kg
Refrigerant: R404A / R23
Weight: 600 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Fully automatic SPS parts washer
BIO-CIRCLERWR 80L Auto KST
Call
Condition: excellent (used), BIO-CIRCLE
Type: RWR 80L Auto KST
Description:
RWR 80 L KST fully automatic SPS parts washer
The RWR units from Bio-Circle are the optimum solution for cleaning internal circulation systems without dismantling.
The unit is space-saving, quiet and very easy to operate.
Thanks to the completely closed system, there is no unpleasant odor from the cleaner or the dirty water.
External dimensions → approx. 1200 x 800 x 1050 mm
Power supply → 400 V 50 Hz plug 16A CEE 5p 6h
Csdpfx Abjtqfbbo Terk
Drain → 1 1/4" outlet
Technical specification:
Type of soiling: limescale, rust (mineral), oil, grease
Quantity of parts: Individual parts, small series, small quantities
Component geometry: Whole components (without disassembly)
Seal of quality: Stainless steel, service package available
Maximum filling capacity: 80 L
Tank material: V2A stainless steel
Electrical connection: 400V / 50 Hz
Heating: 4.5 kW
Flow rate: 25 l/min
Temperature (default setting): 60 °C
Total weight of the cleaning system without tank filling: 180 KG
Area of application:
The RWR 80 L KST fully automatic PLC has been developed for the plastic injection molding sector
and can be used wherever cooling channels (circulation systems, pipes) need to be cleaned.
Application:
Fill the RWR 80 L KST fully automatic SPS with Power Cleaner KST 2.0.
As soon as the minimum fill level is reached and the system is switched on, the system starts to heat up.
During the heating-up period, the system can already be connected to the tool via the two hoses.
The 5-stage cleaning program and the flow direction change run automatically,
after the instructions shown on the display have been confirmed.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Climate test chamber with humidity 1000 liters
CTSC-40/1000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: C-40/1000
CTS climatic test chamber
Condenser chiller air-cooled
Control:
32 bit controller
LCD control panel
Digital display of setpoints and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature test:
Temperature range: -40°C to +180°C
Temperature change rate
Heating speed 2.0 K/min
Cooling rate 2.5 K/min
Temperature deviation ± 0.1 to ± 0.3 K in time
Heat radiation:
approx. 2500 W at +20°C
approx. 2500 W at ± 0°C
approx. 1500 W at -20°C
Climate Working range:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Dew point range I +7 to +94°C
Dew point range II -10 to +7°C
Temperature deviation ± 0.1 to ± 0.3 K in time
Humidity constancy I, temporal ± 0.5 to ± 1.5 % r.h.
Humidity constancy II, temporal ± 1 to ± 3 % r.h.
Panorama window 570 x 710 mm
Test chamber dimensions Width 1000 mm Depth 1100 mm Height 900 mm
External dimensions Width 1270 mm Depth 2220 mm Height 1950 mm
Test chamber volume 1000 liters
Pipe feed-throughs, ø 50
Electrical connection: 400 V +6/-10% 3/N, PE 50 Hz
Connected load: 8.4 kW Rated current: 12.4 A
Refrigerant: R-404A
Weight: 800 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
Credpforu Dzusx Ab Tjk
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Battery tester
ChromaATE 17011
Call
Condition: used, Chroma
Type: ATE 17011
Dimensions: W x D x H 600 x 800 x 1760 mm
Regenerative Cell Tester (5V/100A x 12 channels)
Power supply: 400V/50 Hz 24 KVA
Data Logger (64 channels)
8-Port Sensor Card
Module 17212R-5-100
Max 5V / 100A
Max channels: 12 (fixed)
Parallel operation: 200A, 300A, 400A, 600A, 1200A
V
Adjustable from 0 mV to 5000 mV * 1, resolution 1 mV
A
Crjdpfxowwrn Uj Ab Tjk
Adjustable from 0.01 A to 100.00 A, resolution 0.01 A
Connection:
400V/50Hz, 5 wires
24 kVA
Weight: 250 kg
Condition: used
Scope of supply: (see picture)
(Specifications subject to change and errors excepted!)
We are happy to answer any further questions by phone.
Listing
Borken
18,513 km
Temperature test cell Walk-in test system
CTSTW-60/9 -60°C bis +100°C 9m³
Call
Condition: excellent (used), CTS
Type: TW -60/9
Temperature test cell water-cooled
CTS temperature test cell type TW -60/9
T means: Temperature
W means: Walk in
-60 means: lower temperature -60°C
9 means: 9 m³ test chamber volume
Technical design:
Refrigeration unit:
water-cooled, low-noise, semi-hermetic,
infinitely variable capacity adjustment by electronic
monitoring and control system,
environmentally friendly refrigerant R23 / R404 A
Control system:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material
control
Technical performance data:
Temperature tests:
Temperature range -60 °C to +100 °C
Temperature deviation
± 0.1 to 0.5 K in time
Average rate of temperature change with test material and
with heat radiation measured in the supply air.
Heating: 1.6 K/min from -40 °C to +85 °C
Cooling: 1.6 K/min from +85°C to -40°C
Test material 420 kg of solar cell modules with100% flow
Heat radiation 3000 Watt permanent
The technical data refer to an ambient temperature of +25 °C, nominal voltage 400
V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 9 m³
External dimensions: Width approx. 4140 mm, depth 2680 mm, height 3000 mm
Test chamber dimensions: Width approx. 1600 mm depth 2400 mm, height 2200 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, PE, 50 Hz
Rated power 48.9 kW Rated current: 74.9 A
Cjdpfx Aovb E Uqeb Tsrk
Protection class IP 54
Cooling water connections Cooling water supply/return R1 ¼"", internal thread
Unpressurized condensate drain R1" internal thread
Weight: approx. 5609 kg
Condition: used / second-hand
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
18,513 km
Temperature test cell Walk-in test system
CTSTW-60/9 -60°C bis +100°C 9m³
Call
Condition: excellent (used), CTS
Type: TW -60/9
Temperature test cell water-cooled
CTS temperature test cell type TW -60/9
T means: Temperature
W means: Walk in
-60 means: lower temperature -60°C
9 means: 9 m³ test chamber volume
Technical design:
Refrigeration unit:
water-cooled, low-noise, semi-hermetic,
infinitely variable capacity adjustment by electronic
monitoring and control system,
environmentally friendly refrigerant R23 / R404 A
Control system:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material
control
Technical performance data:
Temperature tests:
Temperature range -60 °C to +100 °C
Temperature deviation
± 0.1 to 0.5 K in time
Average rate of temperature change with test material and
with heat radiation measured in the supply air.
Heating: 1.6 K/min from -40 °C to +85 °C
Cooling: 1.6 K/min from +85°C to -40°C
Test material 420 kg of solar cell modules with100% flow
Heat radiation 3000 Watt permanent
The technical data refer to an ambient temperature of +25 °C, nominal voltage 400
V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 9 m³
External dimensions: Width approx. 4140 mm, depth 2680 mm, height 3000 mm
Test chamber dimensions: Width approx. 1600 mm depth 2400 mm, height 2200 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, PE, 50 Hz
Rated power 48.9 kW Rated current: 74.9 A
Protection class IP 54
Cooling water connections Cooling water supply/return R1 ¼"", internal thread
Unpressurized condensate drain R1" internal thread
Weight: approx. 5609 kg
Cedpfevb Hanex Ab Tjrk
Condition: used / second-hand
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber
CTSTS -70/600-13
Call
Condition: used, CTS
Type: TS -70/600-13
Temperature test chamber, water-cooled
Type series: TS -70/600-13
Control system:
- 32 bit controller
- LCD control panel
Csdjvcyawepfx Ab Tjrk
- Digital display of setpoints and actual values
- Numerical input of setpoint values
- Error messages in plain text
- RS 232 interface
- Free switching channels for on-site test material control
Test chamber volume: 600 liters
Test chamber dimensions: Height approx. 730 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions: Height approx. 2250 mm, width approx. 1300 mm, depth approx. 2475 mm
Temperature range: -70 to +180°C
Heating speed: 13 K/min at -40°C to +120°C
Cooling speed: 13 K/min at 120°C to -40°C
Temperature deviation: ± 0.1K temporal, ± 0.5 K spatial
Electrical connection 400/3P/N/PE
Nominal power: approx. 27.8 kW
Nominal current: approx. 44.1 A
Compressor: 4TC-8.2Y/4PC-10.2Y
Refrigerant: R-404 A / R-23
Weight: 1350 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber 600 liters
CTST-70/600 -70°C bis 180°C
Call
Condition: excellent (used), CTS
Climatic test chamber T-70/600 water-cooled
Temperature range: -70°C to +180°C
Rated voltage: 400V 3/N PE 50 Hz
Rated power: 6.7 kW
Rated current: 10.2 A
Compressor: TFH2480Z/TFH2511Z Refrigerant R23/R404A
Control system:
-Microprocessor-controlled control and monitoring system
Simple, user-friendly terminal built into the door.
-Digital temperature setpoint and actual value display
Simple variation via +/- button
-Digital input for temperature in °C
-PLC compatible
-Up to 100 test programs possible
-RS 232 interface
-2 free switching channels for on-site
test material control
Insert grid:
Stainless steel, contact surface 820 x 710 mm
Load per grid max. 35 kg
Total load with max. grid configuration 100 kg
Cooling unit:
Water-cooled, low-noise, fully hermetic Infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
Temperature tests:
Temperature range -70 °C to+ 180 °C
Temperature deviation ±0.1 to 10.3 K in time
Rate of temperature change
according to DIN 50 011, part 12 measured in the center of the test room
Heating 2.5 K/min
Cooling 2 K/min
Credpfx Aovaxq Nsb Tjk
Heat radiation max. 1500 W at +20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400 V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x Dx H)
External dimensions 1050 x 1850 x 1900 mm (W x DxH)
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current: 10.2 A
Protection class IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber ex protected
CTST-30/950 Ex/I
Call
Year of construction: 2011, condition: excellent (used), CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
Cjdpfx Aboihb Amj Tork
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:
Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:
We make it easier for you to find: "channel"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Channel (962)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month