Used Hardness Test for sale (12,549)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
18,513 km
Temperature test chamber 350 liters
CTSTS-70/350 -70°C bis 180°C
Call
Condition: excellent (used), Here we offer you a temperature test cabinet.
Water cooled
Technical performance data:
Temperature working range
Temperature range in °C -70 / +180°C
Rate of change according to DIN 50 011, part 12
Cooling rate: approx. 5 K/min
Heating rate: approx. 5 K/min
Dimensions:
Test volume: 350 liters
Test chamber dimensions height, approx. 750 mm, width, approx. 650 mm, depth, approx. 720 mm
External dimensions height, approx. 1800 mm, width, approx. 850 mm, depth, approx. 1640 mm
Operating data:
Electrical connection 400 V, 3/N, 50 Hz.
nominal power 13,3 kW
Refrigerant: R404A / R23
Weight: approx. 650 Kg
Type: TS-70/350
For you as a buyer for safety the following information!
Dledpsn Sl T Ssfx Ab Tea
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss temperature shock test chamber air cooled
( Compressor was renewed ! )
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot-/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with swivel arm ) without....ca. 1820 mm with....ca. 1915 mm
Depth ( without and with test chamber door ) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Dljdpfxsk E Htyj Ab Tja
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Dust test chamber dust chamber
Testzentrum Baden Primus EngineeringDST350
Call
Condition: excellent (used), Primus Engineering
Type: DST 350
This test device was designed to carry out IP protection class tests “dust” according to
e.g. DIN 40050 Part 9 and DIN EN 60529.
The test device is intended for testing technical components under the influence
of dust and negative pressure within the limits specified in the technical data.
Operation / HMI
Control panel with screen and buttons
Manual controllers
Stored test sequences
Integrated vacuum circuit with flow measurement
Technical data:
Total electrical output: Max. 5 KW
Connection voltage: 400V/50HZ 3-Ν/ΡΕ (16AEEC socket)
Dimensions: Width approx. 920 mm Depth approx. 710 mm Height approx. 1,770 mm
Dimensions of test chamber: Width approx. 700 mm Depth approx. 650 mm Height approx. 770 mm
Volume approx. 350 I
Dsdort U Nuopfx Ab Tsla
Mass: approx. 200 kg
Vacuum: 0 to -100 mbar
Suction air flow: 0 to approx. 5 l/min
Working climate range: Temperature: +12 °C to +30 °C
Humidity: 25% rel. H. to 75% rel. F.,
non-condensing
Protection class tests according to DIN 40050 Part 9 and DIN EN 60529 (VDE 0470 Part 1)
Dust test:
Dust-protected ΙΡ5Χ and IP5KX
Dust-tight ΙΡ6Χ and IP6KX
with and without vacuum
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
18,513 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80 water cooled
Cold-heat operation: -75°C ...+180°C
Climatic operation: +10...+95°C
Humidity range: 10...98 % r. h.
Temperature constancy, temporally ± 0.2K
Humidity constancy: ±1 r.F.
Temperature rate of change:
Cooling: approx. 1.4 K/min
Heating up: approx. 2.5 K/min
External dimensions: Height 1980 mm, width 1265 mm, depth 1365 mm
Feedthroughs:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/ 50 Hz
Power: 10,4 kVA
Weight: approx. 720 kg
Dodpjm Tvzcjfx Ab Tsla
Refrigerant R404a / R 23
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: SB2/500/80
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Temperature test chamber
CTST-40/600
Call
Condition: excellent (used), CTS Temperature Test Chamber
Here we offer you a CTS temperature test chamber.
Water cooled
Type series: T-40/600
Including metal struts to increase the floor load capacity
Test chamber volume: 600 liters
Test chamber dimensions:
Dljdohxyg Hspfx Ab Tea
Height approx. 850 mm, width approx. 850 mm, depth approx. 830 mm
Outer dimensions:
Height approx. 1900 mm, width approx. 1050 mm, depth, approx. 1850 mm
Temperature working range:
Temperature range -40 to +180°C
Temperature deviation ±0.1 to ±0.3 K temporally
heating speed: 2,5 K/min
cooling rate: 3 K/min
Electrical connection 400 V +6% -10%, 3/N, 50 Hz
rated power: approx. 5,5kW
rated current: approx. 8,5 A
Refrigerant: R404A
Weight: 550 Kg
Type: T-40/600 /011232
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Discover more used machines
Listing
Borken
18,513 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control unit Water-cooled
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
(refrigerant converted to R-452A)
Test chamber capacity: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions: Height 950 mm, width 800 mm, depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 2500 W
Data for operation:
Test room lighting Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A Rated power 7.8 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front. 1m height 58 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Dsdpfx Absrak Rmj Tjla
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Air-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions: Height 950 mm, width 800 mm, depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 2500 W
Data for operation:
Test room lighting Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A Rated power 7.8 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front. 1m height 61 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
Dedpfsrak S Dsx Ab Tjla
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Vibration test system
RMSSW 1507 / TGA 1500
Call
Condition: excellent (used), RMS vibration exciter with power amplifier and cooling fan
Here we offer you a RMS vibration exciter with power amplifier.
Vibration exciter SW 1507
Max force 2158 N
max. speed 1,3 ms
Power amplifier TGA 1500
3 x 380V/ 50Hz/ 35A / 8 kVA
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Dodegkafispfx Ab Tsla
Written order possible by email or fax
Listing
Borken
18,513 km
Shaker vibration test machine
RMSSW 3006 mit TGA 3000-000.00
Call
Condition: excellent (used), RMS Vibration test system
Here we offer you a RMS electrodynamic vibration test system.
RMS Vibration Test System
Test Manager SWR 900
Djdpfxegk I I To Ab Tola
Vibration exciter SW 3006
30V-50A-3434 N
power amplifier TGA 3000-000.00
Condition: used / used
Untested! Tests were not possible
Scope of delivery: (See picture)
(Changes and errors in the technical data, data are reserved!)
Further questions we can answer on the phone for you.
Written order possible by email or fax
Listing
Borken
18,513 km
Climate test cell with humidity
Feutron3707/06 Temp. -40°C bis 150°C
Call
Condition: excellent (used), Here we offer a Feutron climate test cell.
Feutron climate test cell
Temperature
Temperature range: -40...90°C
Climatic range (without heat load) 10...85°C
Temperature difference,temporal during temperature operation ≤ ± 0.5 K/min.
Temperature difference,temporal at climatic operation ± 1,0... ± 1.5 K/min
Rate of change
Heating 2.0 on average K/min
Cooling 2,0 in average K/min
The IEC 1646 standard can be realized with testing, solar modules with max. 160kg weight and non-linear ramps.
(setpoint step change) can be realized
Drying
Air drying Condensation drying
Humidity
Humidification of air Steam humidification
Humidity range 10... 95 % r.h.
Humidity difference,temporal ≤ ± 3,0... ±5.0 %r.H.
Dew point range 8... 80,9 °C
Test room
Test room volume 7.0m³
Dimensions
Test room dimensions width 1500 mm x height 2250 mm x depth 2000 mm
Revolving door DIN right heated,i,l.. width 900 mm x height 2100 mm
Viewing window, heated with darkening flap and lockable Width 500 mm x height 600 mm
Feed-through opening 2x in front side right ∅ 75 mm
Dedpfjklv H Ijx Ab Tjla
Irradiation unit test room
Cut-out 4x in side panel left for SC 2500 850 x 700 mm each
Area to be irradiated when using SC 2500 1200 x 1200 mm
Intensity of radiation at 1.0 m distance from wall 1000 ± 10% W/m²
Lighting 1xhalogen lamp 200W
Refrigeration system Bitzer compressor semi-hermetic 2-stage,air-cooled
Condenser: split condenser (outdoor installation winter control)
Refrigerant R507 /R23
Temperature control system
Cooling brine medium Tyfocor / water
Mixing ratio 50/50
Density of cooling brine 1,072 kg/dm³
Filling quantity approx. 80dm³
Pyranometer Temperature range -40... 150°C
Max. Radiation absorption 4000 W/m²
Spectral range (50% points) 305... 2800nm
Sensitivity (norminal) 7 µV/W/m²
Power supply Test cell
Electrical mains connection 400V, 3/N/PE, AC, 50Hz
Connection type fixed connection
Max. simultaneous power requirement approx. 32.0 kW
Supply line fuse 3 x 63, Char C (A)
Power supply SolarConstant
Electrical mains connection 400V, 3/N/PE, AC, 50Hz
Connection type
Max. simultaneous power requirement approx. 30.0 kW
Supply line fuse 3 x 63, Char C (A)
Outer dimensions of the test cell complete with: Genset room/switch cabinet
and control cabinet for SolarConstant 2500
Outer dimensions of aggregate room width 3440 mm x height 2580 mm x depth 2950 mm
/switch cabinet width 2200 mm x height 1830 mm x depth 1100 mm
Outer dimensions of condenser, split width 900 mm x height 950 mm x depth 2000 mm
Mass of test cell, total approx. 2700 kg
Mass of condenser, empty 153 kg
Weight : 2700 Kg
Type: 3707/06
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Temperature test chamber
FeutronTPK 200 Typ: 3416/17
Call
Condition: excellent (used), Feutron temperature test chamber
Here we offer a temperature test chamber.
Feutron temperature test chamber air-cooled
Nominal test chamber volume: 280 liters
dimensions
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door dismantled: 1500 x 1940 x 925 mm
Test chamber: 720 x 690 x 560 mm
Door, clear width: 720 x 690 mm
Viewing window, heated: 500 x 600 mm
Temperature range
-70°C to +180°C
Heating: 4.0 K /min
Cooling: 0.6 K /min
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Max. power requirement: 6.3 kW
Weight: 600 kg
Type: 3416/17
Refrigerant: R507 / R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
Dledpfx Ajk Scxmsb Toa
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Test chamber for parametric test
S & A-55°C bis +200°C 4365A
Call
Condition: good (used), Here we offer you a S & A test chamber for parametric testing.
Temperature range
-55 ° C to 200 ° C (LCO2)
-65 ° C to 200 ° C (LN2)
Temperature change rate
15° C / min (Standard Option)
60° C / min (Fast Option)
Stability
± 0.2 ° C (including effects of mains voltage, ambient temperature between
between 15° and 45° C and aging)
Uniformity
± 1.0 ° C Max from -65 ° C to -55 ° C
± 0.5 ° C Max from -55 ° C to + 125 ° C
± 1,0 ° C Max from + 125 ° C to + 200 º C
Coolant: LCO2
Dledpfscnic Djx Ab Tea
Chamber can be controlled remotely via IEEE bus or
RS232C interface
Weight approx. 61 kg
Type: 4365A
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, details are reserved!)
Further questions we can answer gladly on the phone for you.
Listing
Borken
18,513 km
Climate test chamber 280 liters
FeutronKPK 200 Typ: 3416/16 +5 °C bis +100 °C
Call
Condition: excellent (used), Here we offer a climatic test chamber.
Air cooled
Nominal test chamber volume: 280 liters
Dimensions
Test chamber outside: 1500 x 2040 x 1075 mm
Fan motor and door disassembled: 1500 x 1940 x 925 mm
test chamber: 720 x 690 x 560 mm
door, clear width: 720 x 690 mm
viewing window, heated: 500 x 600 mm
Temperature range
+5 to +100 C
heating: 4,0 K /min
Cooling: 0.6 K /min
Climate range +10 to +95 C
Dledpjiz Tqcjfx Ab Tja
Humidity range: 10 to 95 % r.H.
Humidity difference, temporal: ≤ ± 3.0
Water connection humidifier: city water or distilled water 20l reservoir tank.
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Power requirement max : 6,3 kW
Weight : 500 Kg
Type : 3416/16
Refrigerant : R134a
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Dlodpfsxmhycex Ab Toa
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Borken
18,513 km
Climate test chamber with humidity, 335 liters
VötschVC 7034 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Dljdpfxsxugiro Ab Toa
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Temperature test chamber 280 liters
FeutronTPK 200 Typ: 3416/17 -70°C bis +180°C
Call
Condition: excellent (used), Feutron
Dledpfx Abju E N Tis Tea
Type: 3416/17
Temperature test chamber Air-cooled
Test chamber nominal volume: 280 liters
Dimensions:
Test chamber outside: width 1540 mm x height 2090 mm x depth 1240 mm
Fan motor and door dismantled: width 1540 mm x height 1940 mm x depth 925 mm
Test chamber: width 720 mm x height 690 mm x depth 560 mm
Door, clear width: width 720 mm x height 690 mm
Viewing window, heated: width 500 mm x height 600 mm
Installation dimensions of the temperature test chamber with doors open
Width 2340 mm x height 2090 mm x depth 2165 mm
Through-hole 2 pieces side wall, left ∅ 100 mm
Temperature range
-70°C to +180°C
Heating: 3.0 K /min
Cooling: 3.0 K /min
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Max. power requirement: 6.3 kW
Weight: 635 kg
Refrigerant: R507 / R23
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Dljdpfxsv N Hc Ee Ab Tsa
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Stress test chamber
Espec (ThermoTec)TPC-212D
Call
Condition: excellent (used), Espec
Type: TPC-212D
Technical Specifications
Test Procedure: HAST – Highly Accelerated Stress Test
Model: Espec TPC-212D
Internal Volume: 2x (approx. 22 liters)
Internal Dimensions (ø x L mm): 2x 295 x 330 mm
Temperature Range: +105 °C to +142.9 °C
Humidity Range: 75% to 100% RH
Pressure Range: 0.02 to 0.196 MPa gauge (0 to 28 psig)
Dsdpewl D Aasfx Ab Tsla
Power Supply: 220 V (±5%), 1-Phase, 50/60 Hz, 20 A
Special Features: Two chambers in one device
Notes:
Two chambers: Allow for simultaneous tests with different parameters or larger test volumes.
HAST test: Accelerated endurance test under high temperature and humidity
with overpressure for the qualification of electronic components.
Applications: Ideal for semiconductors, ICs, circuit boards, MEMS, etc.
Weight: 230 kg
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions over the phone.
Listing
Borken
18,513 km
48V belt starter generator test bench
KübrichKomponentenprüfstand
Call
Condition: excellent (used), Kübrich
Dlsdpfxeumv Emo Ab Tja
Kübrich test systems 48V belt starter generator - component test bench
Details of the test stand: (see Fig. 13)
Frame with
(1) Mounting device for a belt starter generator
(2) Load machine
(3) Belt
(4) MP1: Switch cabinet
(5) MP3: Control cabinet for the control system, transfer plate with main switch, I/O
(6) MP2: Switch cabinet with Simotion
(7) MP4: Switch cabinet with DC-DC converter
(8) H3: Measurement technology box
(9) H4: Transfer box
Intended use:
The test stand is used to carry out tests on belt starter generators during development.
Technical data:
Electrical connection data
Power supply: 400 V / 32 A
Battery simulation: 0 - 60 V
Current: 0 - 250 A (continuous)
Current intensity: 330 A (short term, less than 1 s)
Control voltage 24 V
Mechanical performance data according to the data sheet of the load machine
A transmission ratio of 1:2 to the test specimen shaft must be observed.
Speeds:
Load machine:
Set-up mode: 0 - 50 1/min
Automatic mode: 0 - 10 000 1/min
Test specimen motor:
Set-up mode: 0 - 100 1/min
Automatic mode: 0 - 20 000 1/min
Dimensions and weight
Width: 850 mm Height: 1386 mm Length: 1687 mm
Weight: approx. 1.2 t
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
Dledpfx Aoun Izcjb Tja
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVC 4034 -40°C..+180°C
Call
Condition: good (used), Vötsch
Vötsch Climate Test Chamber, Air Cooled
Converted to refrigerant R-452a
Specifications for Temperature Tests:
Temperature range: -40°C to +180°C
Temporal tolerance: ±0.1 to ±0.5 K
Spatial tolerance: ±0.5 to ±1.5 K
Temperature change rate according to IEC 60068-3-5:
Heating: 3.2 K/min.
Cooling: 3.5 K/min.
Specifications for Climate Tests:
Temperature range: -40°C to +180°C
Temporal tolerance: ±0.1 to ±0.3 K
Spatial tolerance: ±0.5 to ±1.0 K
Humidity range: 10% to 98% r.h.
Dledpexbrkhsfx Ab Tea
Test chamber dimensions: Width 580 mm x Depth 765 mm x Height 750 mm
Housing dimensions: Width 780 mm x Depth 1758 mm x Height 1800 mm
Electrical connection:
Rated voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 4.9 kW
Rated current: 9 A
Refrigerant: R-452a
Test chamber volume: approx. 335 liters
Weight: approx. 515 kg net
Important information for you as a buyer!
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, recharge with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Specifications subject to change and errors excepted!)
If you have further questions, we will be happy to answer them by phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
18,513 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Dlodpfx Asun Ruleb Tea
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Climate test chamber with humidity 34 liters
VötschVCL 7003 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VCL 7003
Air-cooled climatic test chamber
Test chamber capacity approx. 34 liters
Capacity for temperature tests:
Temperature range -70 to +180°C
Temperature deviation over time ±0.3 to ±1.0 K
Temperature homogeneity over space ±0.5 to ±2.0 K
Heating rate of change 4.0 K/min
Cooling rate of change 3.0 K/min
Heat compensation max. 550 W
Temperature calibration value +23°C and +80°C
Capacity for climatic tests:
Temperature range +10 to +95°C
Humidity range 10 to 98%
Humidity deviation over time ±1 to ±3%
Temperature deviation over time ±0.3 to ±0.5 K
Spatial temperature homogeneity ±0.5 to ±1.5 K
Climate calibration values +23 °C / 50% RH and +95 °C / 50% RH
Test room dimensions: Width 350 mm, Depth 300 mm, Height 310 mm
External dimensions: Width 640 mm, Depth 750 mm, Height 1730 mm
Electrical connection:
1/N/PE AC 230 V ±10%, 50 Hz
Rated current 11.0 A
Rated power, max. 2.5 kW
Sound pressure level 59 dB(A)
Refrigerant: R-404 A / R23
Weight approx. 130 kg
For your safety, please note the following information as a buyer!
The following steps are performed on our chambers in advance:
Dedpfx Abov Tnd Ss Tola
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Shaker vibration test system
SentekL1024m mit PA115
Call
Condition: excellent (used), Sentek
Type: L1024m with PA115
Technical data:
Sine Max (kgf / N): 1,000 / 9810
Random force rms (kgf / N): 1,000 / 9810
Shock force (6 ms) kgf: 2,000 / 19620
Usable frequency range Hz: 5-3500
Continuous movement test pk-pk mm: 51
Shock displacement pk-pk mm: 51
Max speed m/s: 2
Max acceleration sine peak m/s²: 980
Shaker:
Shaker head diameter mm: 240
Anchor insert pattern PCD mm plus 1 in the center: 8-100 / 8-200
Thread M10
Resonant frequency ±5% Hz: 3050
Djdpfx Aber A Ezzj Tsla
Max load capacity kg: 200
Natural frequency of the shear axis Hz: < 5
Stray flux density Gauss: < 10
Weight kg: 1150
Dimensions (W x D x H) mm: 884x890x841
Amplifier
Dimensions (W x D x H) mm: 580x850x1800
Amplifier Weight Uncrated kg: 290
Cooler
Type: VAPE500/P2
Dimensions (W x D x H) mm: 620x710x1120
Weight kg: 120
Total weight approx : 1540
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Climate test chamber 1000 liters
CTSC-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Climate test chamber C-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Humidity range: 5 to 95% RH
Dew point range: 5°C to +78°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type C -55/1000/Li
1) C means: climate
2) -55 means: lower temperature -55 °C
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
Climate tests:
Temperature range +5 °C to +95 °C
Humidity range 5% to 95% rel. humidity
Dew point range +5°C to 78°C
Temperature deviation ≤ ±1.0 K in time
Humidity deviation ≤ ±3.0% relative humidity over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may influence the performance data.
Dimensions:
Test volume 1000 liters
Dsdpfx Aova Hi Heb Tsla
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make it easier for you to find: "hardness test"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Hardness Test (12,549)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month


















































































































































































































