Retort heat treatment furnaceMUT
360/400-1150
Retort heat treatment furnace
MUT
360/400-1150
Year of construction
2019
Condition
Used
Location
Zuchwil 

Show images
Show map
Machine data
- Machine type:
- Retort heat treatment furnace
- Manufacturer:
- MUT
- Model:
- 360/400-1150
- Year of construction:
- 2019
- Condition:
- like new (used)
Price & Location
- Location:
- Allmendweg 8, 4528 Zuchwil, Schweiz
Call
Machine sale

Found a new machine? Now turn the old one into cash.
Achieve the best price through Machineseeker.
More about selling machinery
More about selling machinery
Details about the offer
- Listing ID:
- A7819904
- Update:
- 30.12.2024
Description
MUT RWO 360/400-1150 retort heat treatment furnace
- As good as new: hardly used
- Documentation available (both electronic and physical)
- Pallet with spare parts incl.
TECHNICAL DATA
Plant type: RWO 360/400-1150
Furnace chamber temperature: ≤ 1150 °C for max. 1 hour.
Dksdpfoiryyajx Aduju
Working temperature: ≤ 1100 °C , ≤ 1050 °C in vacuum.
Control constancy: ± 2 K
Temperature homogeneity: ± 6 K in the range from 600 °C to 1150 °C at the end of the settling period
Control voltage: 230 VAC / 24 VDC
Working space furnace: 360 x 400 mm
Loading: ≤ 50 kg
Heating: three-zone
Pressure: ≤ 350 mbar
Final pressure vacuum when cold: < 5 * 10-5 mbar with clean, dry furnace.
Installation area: 900 x 1900 x 3000 mm
Total plant weight approx.: 1500 kg
Sound pressure level: < 70 dB
We do not assume any liability for the correctness, completeness and topicality of the information.
The listing was translated automatically. Translation errors are possible.
- As good as new: hardly used
- Documentation available (both electronic and physical)
- Pallet with spare parts incl.
TECHNICAL DATA
Plant type: RWO 360/400-1150
Furnace chamber temperature: ≤ 1150 °C for max. 1 hour.
Dksdpfoiryyajx Aduju
Working temperature: ≤ 1100 °C , ≤ 1050 °C in vacuum.
Control constancy: ± 2 K
Temperature homogeneity: ± 6 K in the range from 600 °C to 1150 °C at the end of the settling period
Control voltage: 230 VAC / 24 VDC
Working space furnace: 360 x 400 mm
Loading: ≤ 50 kg
Heating: three-zone
Pressure: ≤ 350 mbar
Final pressure vacuum when cold: < 5 * 10-5 mbar with clean, dry furnace.
Installation area: 900 x 1900 x 3000 mm
Total plant weight approx.: 1500 kg
Sound pressure level: < 70 dB
We do not assume any liability for the correctness, completeness and topicality of the information.
The listing was translated automatically. Translation errors are possible.
Documents
Seller
Note: Register for free or log in, to access all information.
Registered since: 2018
Send inquiry
Telephone & Fax
+41 32 58... show
Your listing has been deleted successfully
An error has occurred