Used Steam Sterilizer Autoclave for sale (1,003)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Żychlin
17,779 km
Systec VX-100 autoclave
SystecVX-100
Call
Condition: excellent (used), Year of construction: 2014, Autoclave Systec VX-100. The device has only undergone testing phases.
Fully automatic, microprocessor-controlled system covering 12 programs:
1-3 Solids
4-5 Waste destruction bags
6-7 Liquid waste
8-11 Liquid media
12 Cleaning
• Integrated separate steam generator (no heating elements in the sterilization chamber)
• Innovative safety ring closure system with lip seal
• Steam temperature and pressure up to 140°C / 4 bar absolute pressure, extendable to 150°C / 5 bar absolute pressure
• Thermal lock: door locking system controlled by pressure and media temperature according to pressure vessel regulations
Hnjdpfxex R Emko Ah Njg
• Flexible PT-100 temperature sensor for reference vessel
• Sterilization time controlled by media temperature
• Electronic pressure transducer for monitoring pressure and temperature
• “Autofill” – automatic dosing of demineralized water for steam generation
• Special waste destruction program with pulsed heating for better ventilation of waste bags
• Timer start / programmable delayed start
• Outlet steam condensation, water-cooled, thermostatically controlled
• Common manifold connection for all outputs
• Drain valve
• Base plate for tanks, baskets, etc.
• Validation port
• RS 232 interface for external data transfer
• Prepared for subsequent printer installation
• Prepared for subsequent fast cooling installation
• Prepared for subsequent vacuum system installation
• Prepared for subsequent drying installation
• Safety switch for low water level
• Safety switch for overtemperature
Options installed in the autoclave:
Autoclave: VX-100 (Y-1100), ch+w, w, p, s, K, SAPL
ch – cooling
water cooling – ch+w
vacuum – p
drying – s
compressor – k
SAPL – system.
Listing
Neumarkt in der Oberpfalz
18,442 km
Steam boiler; LOOS-350kg/h-13Bar
LOOS-350kg/h-13BarU-HD
Call
Year of construction: 2001, condition: excellent (used), Used steam boilers
Manufacturer: LOOS
Type:U-HD
Year of manufacture:2001
Steam capacity:350 kg/st
Working overpressure:13 bar
Burners available in different versions.
Hnedpfxjizz U Ds Ah Nog
Мы говорим по русски!
Viewing please only after telephone agreement!
Preferred sale to dealers, traders or export.
All information without guarantee, errors and prior sale reserved.
The seller assumes no liability for typing and data transmission errors.
Gladly we take your used boiler or burner in purchase!
Of course we also take care of all formalities
Loading possible
Listing
San Giovanni Al Natisone
18,442 km
STEAM TANK
Call
Condition: used, functionality: fully functional, SECOND-HAND STEAM TANK LENGHT MM. 2100. DIAM. 700
Hnjdpfx Aox Rrrgeh Nsg
Listing
Kalisz Pomorski
17,943 km
Combi steam convection oven
CONVOTHERMC4et 20.10 EB
Call
Condition: reconditioned (used), convotherm 20.10 C4 Oven after complete overhaul. Fully operational, ready for use. Power: 38.9 kW, 56.2 A, 400 V.
Hnjdpjx Rpqmefx Ah Nog
Listing
Duxford
18,728 km
Laboklav 80 MV Autoclave Refurbished
Laboklav80 MV
Call
Condition: used, This Listing is for a refurbished Laboklav 80 MV Autoclave
Incl. commissioning in UK. (outside the UK is possible also, please request and we will try and accomodate)
Vertical device, 80l, can be changed to horizontal version (stand required)
Sterilisation temp. 98-135°C
Outer dimensions (w x h x d in mm) 740 x 915 x 600
chamber dimensions (Ø x d in mm) 410 x 610
Steam generator 6,6kW
Vacuum incl. pre- and postvacuum, heating during postvacuum
Fast re-cooling with double jacket
3N 400V, 50 HZ, 16A, CEE plug
Refurbished according to manufacturer's specifications:
Reconditioning of pressure vessel incl. pressure test, maintenance incl. spare parts (filter, valves, seal, etc.)
According to requirements: Update of cable tree, steam generator, control system and software to the current status. Test runs to ensure and check functionality
Hnjdpfxjxx Aqas Ah Nog
Discover more used machines
Listing
Bad Fallingbostel
18,292 km
Autoclave
KorimatKA 160
Call
Condition: like new (used), Year of construction: 2017, KORIMAT KA 160 – Compact, versatile, indispensable.
Completely overhauled with a 6-month parts warranty. Year of manufacture: 2017.
Ideal for beginners and perfectly suited for spaces with limited room: The KORIMAT KA 160 stands out for its maximum efficiency in a minimal footprint. This handy all-rounder offers much more than just sterilization – as a compact kettle, it brews and cooks delicious specialties. Whether it's perfectly cooked cold cuts, scalded sausages, or classic sterilization, the KA 160 ensures every application is simple and reliable. Experience uncompromising quality and flexibility – for outstanding taste and maximum productivity.
Performance / Power requirement: 9 kW / 400 V / 50/60 Hz
Heating type: Electric
Kettle material: Stainless steel V2A
Kettle capacity: 120 liters
Hnedpox N S Ekofx Ah Nsg
Maximum operating overpressure: 2.5 bar
Minimum circuit protection: 3 x 16 A
Dimensions (W x D x H) in mm: approx. 800 x 1115 x 1900
Listing
القاهرة
16,557 km
Steam turbine
SiemensAFA 4 G5a
Call
Condition: like new (used), Year of construction: 2009, functionality: fully functional, machine/vehicle number: AFA 4 G5a, pressure: 6.6 bar, power: 781 kW (1,061.86 HP), The steam turbine has very low operating hours and was commissioned only once. The control system is integrated into a Siemens control cabinet, Simatic Multipanel type.
Scope of supply:
Hnodpou Tq Egofx Ah Nsg
- Operating panel
- Concrete foundation
- Turbine
- Generator
Electrical output: 781 kWe at 6.6 bar(a) pressure.
• Steam turbine (AFA 4 G5a) with integrated gearbox
– Electronic speed control / exhaust pressure regulation
– Inlet steam pressure control (from below)
– Electronic fast-acting shut-off system with a separate valve
– Nozzle group valves for partial load performance optimization
– Lubrication system according to Frankenthal factory standards, water-cooled
– Safety and monitoring systems according to Frankenthal factory standards
– Flexible coupling based on vibration and torsional analysis
– Synchronous generator, 0.4 kV, IP 23 (optional IP 44 R), with rolling bearings and air cooling
– Mechanical test run on test benches at the Frankenthal factory
– Fully automatic operation via the central control system
– Monitoring cabinet IP 42, including synchronization, compliant with VDE/IEC standards, to be mounted next to the generator according to supplier standards, without power section
Color: Blue
Origin: Germany
Listing
Neumarkt in der Oberpfalz
18,442 km
Steam boiler Viessmann Vitomax 585kg/h
Viessmann Vitomax 200 (585kg/h)M237011
Call
Condition: used, Year of construction: 2003, Steam boiler used
Manufacturer: Viessmann
Type: Vitomax 200
Hjdpjfm E Ifsfx Ah Njng
Year of manufacture 2003
Nominal heat output: 375kw
Boiler water capacity:1400l
Operating overpressure: 8 bar
Gas burner Weishaupt G/1E -Version ZMD-LN
Power 80-550KW:
year of construction: 2003
Connection pressure 15-500mbar.
With existing fittings Dungs DN40
Мы говорим по русски!
Visits please only after telephone arrangement!
Preferred sale to dealers, tradesmen or export.
All information without guarantee, errors and prior sale reserved.
The seller is not liable for typing and data transmission errors.
Gladly we take your used boiler or burner in purchase!
Of course we also take care of all formalities
Loading possible
Listing
Piskorzów
17,996 km
Laboratory autoclave
SystecDE - 150
Call
Condition: excellent (used), Year of construction: 2010, operating hours: 553 h, overall weight: 210 kg, total length: 1,055 mm, total width: 850 mm, total height: 730 mm, Laboratory autoclave: Systec,
Model: DE-150
Volume: 158L
Year of manufacture: 2010
Hnsdpfx Aox Dr Ekjh Njg
Only 553 operating cycles
External dimensions L/W/H: 1055/850/730 mm
Weight: approx. 210 kg
Listing
Bremen
18,325 km
8,550 liter steam-heated reactor made of V4A stainless steel with anchor agitator
Heinrich Nowak9928
Call
Condition: used, tank capacity: 8,550 l, GENERAL
Equipment: Crane lugs
Design: Suspended
Remarks: Feet made of Fe; Flanges partially made of Fe
Speed: 8.5 - 51 rpm
Internal diameter: 2,000 mm
Explosion protection: Motor is explosion-proof (compliance with applicable ATEX directives under local conditions must be verified)
Overall height: 5,200 mm
Heating/Cooling: present
Power: 15 kW
Max. allowable operating temperature: 200°C
Max. allowable operating overpressure: 6.0 bar
Max. overpressure: 3.2 bar
Mechanical seal: Mechanical seal with thermosiphon vessel
Agitator: Anchor agitator
Support type: Feet
Location: Bremen
Technical documentation: Drawing, TÜV certificates
Cylinder temperature control: Half-pipe coil
Nameplate:
Vacuum: 1.0 bar
Volume: 8,550 liters
Double jacket volume: 160.0 liters
Cylinder wall thickness: 8 mm
Product-contact material: V4A 1.4571 (AISI316)
Condition: Used
Cylindrical height: 2,200 mm
Last application: Pharmaceutical chemistry
VESSEL
Max. allowable operating temperature: 200°C
HEATING/COOLING JACKET
Bottom temperature control: Half-pipe coil
EQUIPMENT
Manway / Dome: In top head (DN 500)
Outlet: Flange DN150
MATERIAL SPECIFICATION
Temperature control system material: AISI 304 (V2A) 1.4306
AGITATOR 1
Agitator manufacturer: Ekato
Voltage: 380 Volt
Hodpfexqah Tox Ah Njng
Interference suppressor:
TECHNICAL DATA / DIMENSIONS
Bottom plate wall thickness: 8 mm
Agitator arrangement: Centered in the top head
Agitator equipment: Drive was controlled by an external speed controller by the previous owner (no longer present)
Top head wall thickness: 10 mm
Listing
Duxford
18,728 km
Laboklav 25B Autoclave Refurbished
Laboklav25B
Call
Condition: used, This listing is for a refurbished Laboklav 25B Autoclave
Incl. commissioning in UK. (outside the UK is possible also, please request and we will try and accomodate)
Horizontal device, 25l, glass lid
Sterilisation temp. 98-135°C
Outer dimensions (w x h x d in mm) 440 x 540 x 660
Hnjdpfxoxx Anxe Ah Nog
Chamber dimensions (Ø x d in mm) 265 x 465
Steam generator 2kW
1N 230V, 50Hz, 16A
Refurbished according to manufacturer's specifications:
Reconditioning of pressure vessel incl. pressure test, maintenance incl. spare parts (filter, valves, seal, etc.)
According to requirements: Update of cable tree, steam generator, control system and software to the current status. Test runs to ensure and check functionality
Listing
Neumarkt in der Oberpfalz
18,442 km
Steam Boiler,Steam Generator
LOOS-UH-D-1250kg/hUH-D
Call
Year of construction: 1998, condition: excellent (used), Steam Boiler Used
Manufacturer: LOOS
Type: UH-D
Hjdpeiz Adwofx Ah Nong
Year of construction: 1998
Steam capacity: 1250 kg/h
Weishaupt burner is available in several variants
Мы говорим по русски!
Viewing please only after telephone agreement!
Preferred sale to dealers, traders or export.
All information without guarantee, errors and prior sale reserved.
The seller assumes no liability for typing and data transmission errors.
Gladly we take your used boiler or burner in purchase!
Of course we also take care of all formalities
Loading possible
Listing
Duxford
18,728 km
2014 Mueller PyroPure P4003 Pure Steam Condensing System
MuellerPyroPure P4003
Call
Year of construction: 2014, condition: used, This listing is for a Mueller PyroPure P4003 Pure Steam Condensing System.
The unit is in full working condition and is ready for immediate release.
This Unit was installed new in 2015 by Freestead Process Technology.
This Unit is fitted with a Allen Bradley Compact Logix PLC and Panel View plus 1000 HMI's-
Product Overview:
The Mueller P4003 is a high-capacity pure steam condensing system, part of the trusted PyroPure series. Designed for pharmaceutical manufacturing, this system produces pyrogen-free and endotoxin-free water-for-injection (WFI) by condensing pure steam. Built to meet or exceed U.S. Pharmacopoeia (USP) standards for WFI, as well as CE marked and FDA compliant with 3.1B material certification. It is a versatile solution for facilities requiring both pure steam and WFI quality distillate. Its robust design and advanced features ensure reliable operation, compliance, and minimal maintenance.
Key Specifications:
Model Number: P4003
Capacity: 100 gallons per hour or 379 litres per hour of WFI-quality distillate.
Pure Steam Inlet: 807 pounds per hour or 366 kilograms per hour.
Coolant Requirement: 978 gallons per hour or 3702 litres per hour.
Pure Steam Output Compliance: Pyrogen-free and endotoxin-free, meeting USP WFI standards.
Core Features
High-Quality Output:
Produces pyrogen-free steam and WFI-quality distillate, ideal for pharmaceutical-grade applications.
Utilizes a tangential nozzle design for optimal impurity separation in the pure steam generator.
Efficient Design:
Fully drainable components eliminate contamination risks and ensure clean operation.
Electro-polished 316/316L stainless steel with a maximum surface roughness of 20 Ra for all product contact areas.
USP Class VI-certified elastomers for enhanced safety and regulatory compliance.
Ease of Maintenance:
Removable tube bundle in the condenser allows for easy cleaning and inspection of critical surfaces.
Requires only 24 inches of clearance on all sides for service and maintenance.
Minimal instrumentation with just one control loop simplifies operation and reduces potential downtime.
Installation Flexibility:
Can be integrated with a PyroPure pure steam generator for dual production of pure steam and WFI.
Optional stand-alone design for remote installation at the point of use, adding versatility to your setup.
Hedpfx Ahexv Agce Neng
Applications:
Pharmaceutical Manufacturing: Sterile environments, autoclave processes, and critical cleaning procedures.
Biotechnology: Providing WFI for sensitive biological processes.
Healthcare: Humidification and sterilization in clean rooms or hospital sterilization units.
Listing
Neumarkt in der Oberpfalz
18,442 km
Steam Boiler,Steam Generator
LOOS-UF-600kg/h-16BarLoos-UF-600kg/h-16Bar
Call
Year of construction: 2002, condition: excellent (used), Steam Boiler Used
Manufacturer: LOOS
Type: UF
Year of construction: 2002
Steam capacity: 600 kg/st
Operating overpressure: 6 bar
Burner Weishaupt WG40N/1-A
Design: ZM-LN
Power: 55-550KW
Year: 2002
Connection pressure: 15-500mbar.
Мы говорим по русски!
Viewing please only after telephone agreement!
Preferred sale to dealers, traders or export.
All information without guarantee, errors and prior sale reserved.
The seller assumes no liability for typing and data transmission errors.
Hnsdpsizxbusfx Ah Nsg
Gladly we take your used boiler or burner in purchase!
Of course we also take care of all formalities
Loading possible
Listing
Duxford
18,728 km
Laboklav 135M Autoclave Refurbished
Laboklav135M
Call
Condition: used, This listing is for a refurbished Laboklav 135M Autoclave 2018
Incl. commissioning in UK. (outside the UK is possible also, please request and we will try and accomodate)
Vertical device, 135l, can be changed to horizontal version (stand required)
Sterilisation temp. 98-135°C
Outer dimensions (w x h x d in mm) 840 x 965 x 700
Chamber dimensions (Ø x d in mm) 500 x 660
Hodpfx Asxx Aqmoh Nong
Steam generator 10kW
Fast re-cooling with double jacket
3N 400V, 50 HZ, 16A, CEE plug
Refurbished according to manufacturer's specifications:
Reconditioning of pressure vessel incl. pressure test, maintenance incl. spare parts (filter, valves, seal, etc.)
According to requirements: Update of cable tree, steam generator, control system and software to the current status. Test runs to ensure and check functionality
Listing
Neumarkt in der Oberpfalz
18,442 km
Pure steam condensate vessel
GestraSUL
Call
Year of construction: 1996, condition: excellent (used), Used condensate vessel
Manufacturer: Gestra
Year of manufacture: 1996
Мы говорим по русски!
Hodpsiz A Tzjfx Ah Njng
Viewing please only after telephone agreement!
Preferred sale to dealers, traders or export.
All information without guarantee, errors and prior sale reserved.
The seller assumes no liability for typing and data transmission errors.
Of course we also take care of all formalities
Loading possible
Listing
Duxford
18,728 km
WFI System with 2 Mueller Clean Steam Generators.
Call
Year of construction: 2002, condition: used, This listing is for a WFI System with 2 Mueller Clean Steam Generators.
The system was installed in 2002, is in working condition, and is ready for immediate use.
-----
System Overview
A complete Water For Injection (WFI) production, clean-steam generation, and storage system for pharmaceutical or biotech facilities. Produces ultra-high purity water and clean steam using dual Mueller steam generators, pressure columns, UV filtration, and automated control via a Pharma Tec panel.
Hnjdpfx Asxv Aaioh Njg
-----
Main Components
Mueller Clean Steam Generators ×2 – dual units producing clean / pure steam for WFI and sterilization duties.
Four Pressure Columns – separation, purification, and holding of steam / condensate under controlled pressure.
Fristam Pumps – sanitary main supply pumps providing feedwater or circulation through the system.
Hanovia UV Filters – ultraviolet sterilizing filters to remove microbiological contamination from feedwater or WFI stream.
Pharma Tec Control Panel – automation and control system with PLC, level, temperature, pressure, and conductivity monitoring; full alarm & data-logging.
-----
Key Features
Dual redundancy via two clean steam generators allows maintenance or alternating load without shutdown.
Four pressure columns improve separation, holding and stability of steam / condensate under varying pressure loads.
UV filtration ensures microbiological safety in line with regulatory requirements.
Sanitary pumps (Fristam) for clean design, ease of clean-in-place, and high hygiene.
Automated control panel (Pharma Tec) providing precise monitoring, control, and regulatory compliance.
-----
Specifications
Manufacturer: Mueller, Fristam, Hanovia / Pharma Tec
Year Installed: 2002
System Type: Clean Steam + WFI generation & storage
Steam Generators: 2 × Mueller Clean Steam Generators
Prize Pumps: Fristam sanitary feed / supply pumps
Filtration: Hanovia UV sterilisation units on feed / WFI lines
Control: Pharma Tec PLC / automation panel with full instrumentation (pressure, temperature, level, conductivity)
Operating Conditions: Designed for pharmaceutical WFI-grade water and clean steam (sterile / pyrogen-free)
Listing
Neumarkt in der Oberpfalz
18,442 km
Steam boiler Loos 500kg/h 1Bar
Dampfkessel Loos 500kg/h 1Bar
Call
Year of construction: 1996, condition: excellent (used), Steam Boiler Used
Manufacturer: LOOS
Year of manufacture: 1996
Steam capacity: 500 kg/h
Weishaupt gas burner G3/1-E
Type: ZD-NA
Hnodoiz S Suepfx Ah Nsg
Power: 80-550Kw
Year: 1996
Weishaupt burner is available in several variants
Мы говорим по русски!
Viewing please only after telephone agreement!
Preferred sale to dealers, traders or export.
All information without guarantee, errors and prior sale reserved.
The seller assumes no liability for typing and data transmission errors.
Gladly we take your used boiler or burner in purchase!
Of course we also take care of all formalities
Loading possible
Listing
Duxford
18,728 km
MMM Group Vakulab HL Medical Autoclave
MMM GroupVakulab HL
Call
Condition: used, This listing is for the MMM Group Vakulab HL Medical Autoclave.
The unit is in full working condition and is ready for immediate use.
Overview
The Vakulab HL autoclave from MM Group Medical is a high-performance, GMP-compliant sterilizer designed for the safe, reliable, and validated sterilization of laboratory instruments, equipment, and materials. Specifically engineered for use in pharmaceutical manufacturing, biotechnology facilities, and research laboratories, the Vakulab HL combines advanced vacuum-assisted steam sterilization with robust stainless steel construction to ensure consistent results in even the most demanding applications.
Key Features
Advanced Steam Sterilization
Pre- and Post-Vacuum Cycles: Ensures efficient steam penetration and rapid drying
Optimized Steam Distribution: Uniform sterilization across all load types
Programmable Cycles: Fully adjustable parameters for different sterilization needs
GMP & Cleanroom Ready
Double-Door Pass-Through Design (optional): For installation between clean and non-clean areas
Stainless Steel Chamber & Piping: High-grade AISI 316L for corrosion resistance and hygienic operation
Integrated Monitoring: Real-time cycle control with full batch documentation capability
Operational Safety & Control
User-Friendly HMI: Touchscreen interface for programming and monitoring
Automatic Door Operation: With safety interlocks to prevent accidental opening under pressure
Built-In Diagnostics: Self-check functions for preventive maintenance
Technical Specifications
The Vakulab HL is a vacuum-assisted steam sterilizer available in multiple chamber volumes, typically ranging from 300 to 1,000 liters. The sterilization process operates at temperatures between 121 °C and 134 °C, controlled via a PLC-based system with an intuitive touchscreen human-machine interface (HMI). The chamber is constructed from AISI 316L stainless steel, ensuring corrosion resistance and compliance with GMP hygienic standards.
A water-ring or liquid-ring vacuum pump enables pre-vacuum and post-vacuum phases for thorough air removal and effective drying. Door configurations can be single or double-door in either sliding or hinged formats, with safety interlocks to prevent opening under pressure. The autoclave requires standard utility connections for steam, water, compressed air, and electricity. It is designed to meet EN 285, PED, ISO 9001, and GMP compliance requirements, and can be validated to ISO 17665 sterilization standards.
Applications
Pharmaceutical Manufacturing: Sterilization of equipment, components, and containers
Biotechnology: Sterilization of fermentation vessels, culture media, and instruments
Research Laboratories: Sterilization of glassware, tools, and lab consumables
Hospitals & Clinical Settings: Safe sterilization of surgical instruments and textiles
System Components
Hedpfx Aoxv Dvfoh Njng
High-grade stainless steel chamber with polished finish
Vacuum pump system for pre- and post-cycle air removal
Steam generation and distribution system
Control panel with PLC and HMI touchscreen
Integrated temperature and pressure sensors for validation
Quality & Compliance
Manufactured in accordance with GMP guidelines
Complies with EN 285 and ISO 17665 sterilization standards
Full FAT/SAT/IQ/OQ/PQ support for validation in regulated environments
Designed for integration into cleanroom and production facilities
Benefits
Consistent, Validated Sterilization for a wide range of load types
Flexible Confi...
Listing
Neumarkt
18,442 km
Steam boiler Omnical 6000kg/h -13Bar
Omnical 6000kg/h -13BarOmnical 6000kg/h -13Bar
Call
Condition: excellent (used), Omnical 6000kg/h -13Bar. Year 2005
Hsdpfxjhtf A Uo Ah Neng
Listing
Duxford
18,728 km
KSA SQ1E Steam Quality Test Kit
KSASQ1E
Call
Condition: used, This listing is for the KSA SQ1E Steam Quality Test Kit.
The system is in excellent working condition and ready for immediate use.
-----
System Overview
The KSA SQ1E is a portable, air-cooled steam quality testing unit designed for performing Non-Condensable Gas (NCG), Dryness, and Superheat tests in compliance with EN 285 and HTM standards. It provides a complete, self-contained solution for validating clean and pure steam systems used in pharmaceutical, biotechnology, and healthcare facilities.
Unlike traditional systems, the SQ1E uses a built-in electric fan condenser, removing the need for cooling water and allowing tests to be carried out anywhere with minimal setup. The compact and durable design makes it ideal for on-site steam testing, validation, and qualification work.
-----
Main Components
KSA SQ1E Steam Quality Test Unit – fully air-cooled condenser assembly with built-in burette and measuring cylinder for NCG and dryness testing.
Hodoxqqyyspfx Ah Njng
Dryness and Superheat Test Assembly – includes test expansion tube, pitot tubes, flask, and temperature probe connections.
Integrated Burette and Measuring Cylinder – illuminated and fitted with push-button zeroing and pause functions for precise readings.
Power Supply – 12 V DC operation for the condenser fan and internal electronics.
Steam Connection Set – includes tri-clamp and hose fittings for connection to clean steam systems.
Portable Case – compact and rugged housing with handle and workspace shelf for field testing.
Operating Manual and Documentation – includes standard test procedures, setup guidance, and result templates.
-----
Key Features
Air-cooled condenser design eliminates the need for external cooling water.
Performs all required steam quality tests: Non-Condensable Gases, Dryness, and Superheat.
Built-in burette and measuring cylinder for accurate, repeatable measurement.
Push-button zeroing, pause function, and backlit illumination for ease of use.
Portable, plug-and-play design ideal for site validation and testing.
Complies fully with EN 285, HTM, and pharmaceutical clean steam standards.
-----
Specifications
Manufacturer: KSA (Keystone Scientific / KSA Pharma)
Model: SQ1E
Type: Steam Quality Test Kit
Power Supply: 12 V DC
Cooling Method: Air-cooled, fan-assisted condenser
Functions: NCG, Dryness, Superheat testing
Operation: Manual/portable
Compliance: EN 285, HTM, AAMI, PDA guidelines
Construction: Stainless steel and aluminium components in rugged portable case
Trust Seal
Dealers certified through Machineseeker

Listing
Walton-on-the-Naze
18,725 km
MMM Stericell Hot Air Sterilizer
MMM
Call
Condition: used, This listing is for a MMM Stericell Hot Air Sterilizer.
Good working and cosmetic condition.
The STERICELL® hot air sterilizer is intended for use in healthcare for the hot air / dry heat sterilization process of non-packaged and packaged medical devices, including invasive devices designed by their manufacturers for hot air / dry heat sterilization.
Hnjdpfxoxzg N Es Ah Njg
Listing
Duxford
18,728 km
2014 Mueller PyroPure P7310 Pure Steam Generator
MuellerPyroPure P7310
Call
Year of construction: 2014, condition: used, This listing is for 1 of 2 Mueller PyroPure P7310 Pure Steam Generator.
The unit is in full working condition and is ready for immediate release.
This Unit was installed new in 2015 by Freestead Process Technology.
The “Turned on Time”of the unit is 65,000 hours, but as this unit is 1 of 2 generators in an alternating system it does not indicate the "Steam Production Time". The sites steam requirements were low therefore the unit is in immaculate condition.
They have full maintenance records backed up on their electronic technical system supplied as an extra by Freestead.
This Unit is fitted with a Allen Bradley Compact Logix PLC and Panel View plus 1000 HMI's
The Unit is supplied with-
⦁ Feed water pump system
⦁ Pure steam condensate sampling system
⦁ Pure steam analyser
⦁ Stainless steel sheathing and frame
⦁ Feed water analyser
⦁ Degasser
The Mueller PyroPure P7310 Pure Steam Generator is a high-performance system designed to produce pyrogen-free pure steam suitable for the most demanding applications, such as pharmaceutical production, biotechnology processes, and healthcare sterilization. Built to meet or exceed U.S. Pharmacopoeia (USP) standards, the P7310 combines precision engineering, advanced technology, and robust materials to ensure consistent performance and reliability. They are CE marked and compliant with 3.1B material certification.
The terms pure steam and clean steam are often used interchangeably in the pharmaceutical industry. However, not all equipment marketed as clean steam generators are up to the task of producing WFI quality pharmaceutical pure steam. Mueller pure steam generators use a tangential nozzle to provide separation of impurities from incoming feed water, producing pyrogen-free steam that, when condensed, meets USP requirements for water for injection.
Key Benefits
Superior Steam Quality:
Produces pyrogen-free steam that meets USP requirements, ensuring safety and regulatory compliance.
Optimized for critical applications like autoclaves, clean room humidification, and steam-in-place (SIP) sterilization.
Achieves a 5 Log reduction in contaminants, which corresponds to a 99.999% reduction in microbial populations. This level of reduction ensures the highest degree of sterilization, making it ideal for pharmaceutical and biotechnology applications where absolute purity is critical.
Efficient Design:
External evaporator allows easy access for inspection and maintenance, reducing downtime.
Separation column has no internal components requiring maintenance, eliminating potential for bacterial growth.
Efficient heat transfer with a double-tube sheet evaporator minimizes stress cracking and maximizes performance.
Hnedexv Af Sopfx Ah Nog
Ease of Maintenance:
All critical components can be serviced with only 24" of clearance around the system.
Fully drainable design prevents standing water, reducing contamination risks.
Polished 316/316L stainless steel construction ensures durability and easy cleaning.
Enhanced Operational Features:
Minimal instrumentation is required, reducing complexity and operational costs.
Simplified control with an Allen-Bradley PLC system, compatible with Ethernet for integration with facility systems.
Certified elastomers (USP Class VI) provide enhanced compatibility with feed water and product.
Specifications
Performance:
Pure Steam Capacity: from 0 to 700 kg/hr at optimal feed water conditions.
Operating Pressure Range: Pure steam output pressure up to 50 psig.
Mater...
Listing
Duxford
18,728 km
Laboklav 25MV Autoclave Refurbished
Laboklav25MV
Call
Condition: used, This listing is for a refurbished Laboklav 25MV Autoclave
Hnsdpfxoxx Anre Ah Nsg
Incl. commissioning in UK. (outside the UK is possible also, please request and we will try and accomodate)
Horizontal device, 25l, glass lid
Sterilisation temp. 98-135°C
Outer dimensions (w x h x d in mm) 440 x 540 x 660
Chamber dimensions (Ø x d in mm) 265 x 465
Steam generator 2kW
Fast re-cooling by air
Vacuum incl. pre- and postvacuum, heating during post vacuum
1N 230V, 50Hz, 16A
Refurbished according to manufacturer's specifications:
Reconditioning of pressure vessel incl. pressure test, maintenance incl. spare parts (filter, valves, seal, etc.)
According to requirements: Update of cable tree, steam generator, control system and software to the current status. Test runs to ensure and check functionality
Listing
Duxford
18,728 km
Laboklav 55M Autoclave Refurbished
Laboklav55M
Call
Condition: used, This listing is for a refurbished Laboklav 55M Autoclave
Incl. commissioning in UK. (outside the UK is possible also, please request and we will try and accomodate)
Hedpfxsxx An Ss Ah Neng
Vertical device, 55l, can be changed to horizontal version (stand required)
Sterilisation temp. 98-135°C
Outer dimensions (w x h x d in mm) 740 x 765 x 600
chamber dimensions (Ø x d in mm) 410 x 460
Steam generator 3,3kW
Fast re-cooling with double jacket
1N 230V, 50Hz, 16A
Refurbished according to manufacturer's specifications:
Reconditioning of pressure vessel incl. pressure test, maintenance incl. spare parts (filter, valves, seal, etc.)
According to requirements: Update of cable tree, steam generator, control system and software to the current status. Test runs to ensure and check functionality
We make it easier for you to find: "steam sterilizer autoclave"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Steam Sterilizer Autoclave (1,003)
Search Machineseeker now with more than 200,000 used machines:Browse through the most popular machine descriptions:
This may be of interest to you




































































































































































