Used Measuring & testing equipment for sale (1,325)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Listing

18,513 km
Temperature chamber with vibration table
EspecQualmark T2.5 + Kompressor 99480630
Call
Condition: like new (used), HALT/ HASS Espec
Here we offer you a temperature chamber.
Temperature -100 to + 200°C
Table in lower position (WxDxH) 889 x 889 x 889 mm
Table in upper position (WxDxH) 889 x 889 x 635 mm
Overall dimensions (WxDxH) 1425 x 1748 x 2134 mm
Work table 762 x 762 mm
Max load 145 kg
Acceleration 5 to 75 gRMS
Voltage
Dslq Sljqwybgjansut
480 or 440 V / 60 A / 3F
400 or 380 V / 80 A / 3F
Type: Qualmark T2.5 + compressor 99480630
Condition: used Only 147 hours
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
More We will be happy to answer any questions you may have over the phone.
Listing

18,513 km
Climatic chamber
CTSCS-70/1850-5
Call
Condition: good (used), CTS climatic test chamber
Here we offer a CTS climatic test chamber.
Climate test chamber type: CS-70/1850-5 water-cooled
1) C means: Climate
2) S means: stress screening
3) -70 means: lower temperature -70°C
4) 1850 means: 1850 liter test chamber volume
5) 5 means: Temperature change rate of 5 K/min according to IEC 60068-3-5
Test chamber lighting:
Halogen lamp 20 W, 12 V
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoint values
Error messages in plain text
RS 232 interface
Dujljqzgwuoq Slanot
Free switching channels for on-site test material control
Technical performance data:
Temperature tests:
Temperature range -70°C to +180°C
Temperature deviation ≤ ± 0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 5 K/min
Cooling 5 K/min
Heat radiation:
approx. 5500 W at +20°C
approx. 5500 W at ± 0°C
approx. 3700 W at -40°C
Climatic tests:
Temperature range +10°C to +95°C
Humidity range 10% to 98% rel. humidity
Dew point range I: +7°C to 94°C
Dew point range II (deep dehumidification): -10°C to +7°C
Temperature deviation ≤ ± 0.3 K in time
Humidity deviation I ≤ ±1.5% r.h. over time
Humidity deviation II ≤ ±3 % r.h. over time
Dimensions:
Test volume 1850 liters
Test chamber dimensions: Height 1085 mm Width 1470 mm Depth 1400 mm
External dimensions: Height 2210 mm Width 1600 mm Depth 2645 mm
Insert grid:
Stainless steel, support surface 1300 x 1170 mm
Max. load per shelf 35 kg
Total load with max. grate load 100 kg
1a Pipe feed-through NW 50
1b Pipe feed-through 2x NW 125
2 Control panel
3 Window 570x710
4 Electrical connection, fixed
5 Pressure equalization
7 Test chamber drain and
air conditioning system R 1/2 "i
8 Demineralized water inlet R 1/2 "i
9 Cooling water return R 3/4 "i
10 Cooling water inlet R 3/4 "i
11 Main switch
12 Electrical compartment
13 Compressed air R 1/4 "AG, option
14 Cable bushing for interface connections
Technical version:
Refrigeration unit:
Water-cooled, low-noise, semi-hermetic,
infinitely variable capacity adjustment through electronic
monitoring and control system, environmentally
friendly refrigerant R404A/ R23
Compressor: 4EC-4.2Y / 4CC-6.2Y
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Rated output: 33 kW Rated current: 41.3 A
Protection class: IP 22
Weight: approx. 1300 kg
Type: CS-70/1850-5
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Heat cabinet with nitrogen supply
VötschTU 60/60 G-ISO Temp. 250°C
Call
Condition: excellent (used), Here we offer a bird heat cabinet with nitrogen supply.
Vötsch heat cabinet with nitrogen supply
Nominal temperature: 250°C
Name stream: 10 A
Connection value: 6.3 KVA
Nominal voltage: 400V3coma N)PE AC 50/60hz
Nominal power: 6 KW
Type: TU 60/60 G-ISO
Condition: used/used
Delivery: (See picture)
(Changes and errors in the technical data, information is reserved!)
We can answer more questions on the phone for you.
Dujlq Slod Ngg Tjanjt

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month
Listing

18,513 km
Electrodynamic Vibration Shaker
RMSSchwingprüfanlage SW 1508/1
Call
Condition: good (used), Here we offer you a vibration test system.Test Manager SWR 900Control cabinet SWS 200-10Vibration exciter SW 1508/1Hydraulic supply SWT 1110/11Power amplifier TGA sound insulation housing SWG 211/1Fan SWG 103Operating hours: approx. 1,300 hoursCondition: used / usedScope of delivery: Vibration test system as shown(Changes and errors in the technical data, specifications reserved!)We are happy to answer further questions for you on the phone.
Delq Sljd Tp Ausaneut
Listing

18,513 km
Shaker system sliding table and amplifier
LDSV870-440 LBT900C + SPA20/40K
Call
Condition: excellent (used), LDS
Type: V870-440 LBT900C with amplifier SPA20/40K
Shaker for medium forces
Technical data:
Armature dimensions: 440 mm
Sinusoidal force vector 26.688 kN (peak)
Rausch force vector 26.688 kN (effective)
Half sine force vector 80 kN
Mass of the movement element 32.2 kg
Frequency range d.c. - 3000 Hz
Test specimen mass max. 600 kg
Sinus B acceleration max. 735.5 m/s²
Noise acceleration max. 1055 m/s²
Velocity max. 1.4 m/s
Deflection ± 44.56 mm
Amplifier dimensions :
WxHxD mm : 537mm x 1905mm x 895mm
Sliding table:
WxHxD: approx 1400 mm x 1280mm x 2065mm
Work surface: 900 mm * 900 mm
Thickness of the top: 50 mm
Weight of the top: 78 kg
Max load : 1000 kg
Condition : gebraucht / used
weight:
Shaker approx. 2230 kg
Blower 181 kg
Amplifier: 622 kg
Sliding table 3570kg
Scope of delivery: (see pictures)
Djlq Slasuy H I Heneut
Total weight approx. 6700 kg
(We reserve the right to make changes and errors in the technical data!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss temperature shock test chamber air cooled
( Compressor was renewed ! )
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot-/cold chamber 10 s
Temperature constancy ±1 K
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with swivel arm ) without....ca. 1820 mm with....ca. 1915 mm
Depth ( without and with test chamber door ) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
Delq Sok E Htyjlanjut
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

18,513 km
Temperature chamber 2000 liters
CTST-40/2000 -40°C bis +180°C
Call
Condition: excellent (used), CTS
Type: T-40/2000
Air-cooled temperature test chamber
Technical design:
Refrigeration unit:
air-cooled, low-noise, fully hermetic, infinitely variable power adjustment
through electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
fully opening door, door hinge left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 + 500 mm
Max. load per shelf 35 kg
Total load with max. grid load 100 kg
Test area lighting: 3x halogen lamp 20 W, 12 V
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoint values
Error messages in plain text
RS 232 interface
Free switching channels for on-site test material control
Temperature range: -40°C to +180°C
Nominal voltage: 400V 3/N 50Hz
Rated power: 10.4 kW
Nominal current: 17.2 A
Compressor: TFH2516Z
Pipe feed-through NW 50
Control panel
Window 570x710 mm
Electrical connection, cable length 5m
Technical performance data:
Temperature tests:
Temperature range -40°C to +180°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 1.5 K/min
Heat radiation:
approx. 2500 W at +20°C
approx. 2100 W at ± 0°C
approx. 1500 W at -20°C
Duelq Sleup T Uqoanjt
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Dimensions:
Test volume: 2000 liters
Test chamber dimensions: Height 900, width 975, depth 2200 mm
External dimensions: Height 1950, width 1290, depth 3145 mm
Operating data:
Electrical connection: 400 V +6/-10 %, 3/N, 50 Hz
Rated power: 17.2 kW
Protection class: IP 22
Condensate drain unpressurized R 1/2" internal thread
Sound pressure level (according to DIN EN ISO 3744
measured at a distance of 1 m from the front) < 55 dB(A)
Weight: approx. 1200 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Temperature shock test chamber
CTSTSS-70/130 +50°C...+250°C -80°C...+100°C
Call
Condition: excellent (used), CTS
Type: TSS-70/130
CTS water-cooled temperature shock test chamber
Type series TSS -70/130
Test chamber volume 130 liters
Test chamber dimensions:
Height, approx. 410 mm Width, approx. 480 mm Depth, approx. 660 mm
External dimensions:
Height, approx. 1820 mm Width, approx. 940 mm Depth, approx. 2335 mm
Temperature operating range:
Temperature range in °C :
Hot chamber +50/+250°C
Cold chamber -80/+100°C
Retempering of ICs < 15 min in kg 10.0
Car changeover time in sec. < 10
Max. test weight in kg 50
Temperature constancy over time in K ± 1
Delq Sljtql H Aeansut
Electrical connection 400 V +6% -10%, 3/N, 50 Hz
Connected load in kW approx. 16.6
Condenser chiller water-cooled
Test chamber weight in kg approx. 950
Sound pressure level in dB(A) < 60
Feed-through Ø in mm 125
Refrigerant: R404A/R23
Weight: 950 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Salt spray chamber
WeissSC/KWT 450
Call
Condition: good (used), White
Type: SC/KWT 450
Salt spray chamber
Technical data:
Test chamber capacity 450 liters
Max. load 100 kg
Brine storage tank 180 liters
External dimensions: Height 920 mm Width 1930 mm Depth 800 mm
Test compartment dimensions: Height 740 mm Width 850 mm Depth 570 mm
Areas of application:
Corrosion tests:
Salt spray test: room temp. up to + 50°C
Condensation water test: Room temp. up to + 45°C
Humidifier +75°C
Temperature constancy
The temperature deviation over time is ± K.
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power 2.0 kW Rated current 8.5 A
Combination:
Salt spray test SS: DIN 50021
Condensation water test KFW: DIN 50017
Normal climate (ventilation): DIN 50014
Weight: 180 kg
Condition: second-hand / used
Scope of delivery: (see picture)
Duoljudvg Rsq Slanet
(We reserve the right to make changes and errors in the technical data and specifications)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Climatic test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Delq Sljuudx Deansut
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Climate cell
TiraTCZ 4012
Call
Condition: good (used), TIRA
Type: Walk-in climate simulation cell TCZ 4012 S(m)
Technical data:
Temperature range -40...+120 °C
Temperature tolerance: +/- 1.0°C
Temperature change rate: 1 K/min
Humidity range
10...approx. 95 % r.h.
Humidity tolerance
+/- 5.0 % r.h.
Dimensions:
Test chamber volume: 13m³
External dimensions (WxDxH) approx. 2260mm X 3850mm X 2780mm
Test chamber (WxDxH) approx. 2254mm Χ 2645mm Χ 2251mm
Door opening (WxH) approx. 2251mm X 2254mm
Duelq Slouvipweanot
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Climate cell
WEISS WK 50 /40-120
Call
Condition: good (used), White
Type: Walk-in climate simulation cell WK 50 / 40-120
Dslq Slasuvi R Aoneut
Technical data climatic chamber:
Temperature range -40...+120 °C
Temperature tolerance: +/- 0.5°C
Temperature change rate: 1 K/min
Humidity range
15...approx. 95 % r.h.
Humidity tolerance
+/- 5.0 % r.h.
Dimensions:
Test room volume: 50m³
External dimensions (WxDxH) approx. 4800mm X 6100mm X 2640mm
Test chamber (WxDxH) approx. 4500mm Χ 5000mm Χ 2200mm
Door opening (WxH) approx. 3000mm X 2200mm
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Temperature test chamber 270 liters
VötschVTS³ 7027-25 -72°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7027-25
Heraeus Vötsch temperature test chamber, water-cooled
Performance data:
With temperature change rate of 25 K/min
Test chamber dimensions Height 750 mm Width 580 mm Depth 615 mm
External dimensions Height 1775 mm Width 780 mm Depth 1895 mm
Temperature range -72°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5
Temperature homogeneity in space ± 0.5 to ± 2.0
Temperature change rate cooling 25 K/min
Temperature change rate heating 25 K/min
Heat compensation at -20 °C 8000 W
Heat compensation at +20 °C 8000 W
Test volume: 270 liters
2x lateral feed-through ∅ 125 cm
1x side feed-through ∅ 50 cm
Cabinet is water-cooled
Test room lighting:
LED strip 24 V, 6.8 W / 2x halogen bulb 24 V, 50 W
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 24 KW
Rated current: 42 A
Refrigerant: R-404A and R-23
Weight: approx. 980 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Dujlq Sletz Rl Dsanjt
Listing

18,513 km
Climate chamber with humidity 34 liters
WeissWKL 34/60 -60°C bis 150°C
Call
Condition: excellent (used), White
Type: WKL 34/60
Weiss air-cooled climate chamber
Refrigerant converted to R-452A
-60°C to 150°C
Room volume: 34 liters
Entry port installed in basic equipment:
Djlq Sletr Dinsansut
R1 NW 50 mm
L1NW 120 mm
Internal dimensions: Height 310 mm Width 324 mm Depth 300 mmm
External dimensions: Height 1740 mm Width 630 mm Depth 970 mmm
Characteristic values for temperature tests:
Temperature range -60 to +150 °C
Temperature differences in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 1 K ± 1 to ± 2 K
Temperature deviation in space (corresponds to temperature gradient) 2 to 4
Temperature change rate (according to IEC 60068-3-5)
Heating 2.5 K/min
Cooling 3 K/min
Heat compensation max. 550 W
Characteristic values for climate tests:
Temperature range +10 to +95 °C
Humidity range 10 to 98 %r.H.
Temperature and humidity differences (in steady state, according to IEC 60068-3-5)
Temperature fluctuation over time in the center of the usable space ± 0.3 to ± 0.5 K
Temperature deviation in space ± 0.5 to ± 1.5
(corresponds to temperature gradient) 1 to 3
Humidity fluctuation over time in the center of the usable space ± 3 to ± 5 %RH
Data for operation:
Test room lighting Halogen bulb 12V, 20W
Nominal voltage 1/N / PE AC 230 V ± 10 % 50 Hz
Rated power 2.5 kW
Rated current 11 A
On-site fuse 16A slow-blow
Heat dissipation air-cooled test chambers
Max. Heat dissipation to surroundings 1700 W
Refrigerant: R-452A / R23
Weight: 140 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
Duelq Slaou H U Twsnet
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing

18,513 km
Climate test chamber Sunlight simulation
VötschVCL 4200/S -40 bis +150 °C 3300 Liter
Call
Condition: excellent (used), Vötsch
Type: VCL 4200/S
Water-cooled climatic test chamber
Irradiation device with metal halide radiator
Door with window
Internal dimensions : Width 2000 mm Height 1000 mm Depth 1150 mm
External dimensions : Width 3300 mm Height 2000 mm Depth 1250 mm
2X pipe penetration 125 mm
Performance range for temperature tests without irradiation
Temperature range - 40°C to +150°C
Temperature deviation ± 0.5 K in time, in the supply air to the test room
Temperature change rate according to DIN 50 011 Part 12
Heating: approx. 1.0 K/min.
Cooling: approx. 1.0 K/min to -30°C
Performance range for climatic tests without irradiation
Temperature range +10°C to +95°C
Temperature constancy ± 1.0 K over time, in the supply air to the test room
Humidity range 10 to 95 % r.h.
Humidity constancy ± 1 to ± 3 % r.h. over time, in the supply air to the test room
Duolqsvccwle Slanst
Dew point range +5°C to +88°C
Irradiation (solar simulation attachment)
Irradiation type:
4 pcs. 2 kW metal halide radiators each
Irradiance 1000 W/m² ± 5 %
in the range 280 to 3000 nm
Irradiation uniformity ± 50 W in the guaranteed area
Reference plane taking into account the installed
lateral reflector plates
Test area (W x D) 1700 x 800 mm
with distance reference plane - UK irradiation unit
of approx. 750 mm or 400 mm above the floor
Performance range for temperature tests with irradiation
Temperature range -10°C to +100°C
Temperature deviation in time ± 1.0 K, in the supply air to the test room
Rate of temperature change
according to DIN 50 011, part 12
Heating: approx. 1.5 K/min.
Cooling: approx. 0.5 K/min.
Performance range for climatic tests with irradiation
Temperature range + 10°C to + 80°C
Temperature deviation ± 1.0 K over time, in the supply air to the test room
Humidity range 10 % to 85 % r.h.
Humidity deviation ± 1 % to ± 3 % r.h. temporally, in the supply air to the test room
Dew point range + 5°C to + 76°C
Average temperature and humidity changes
If temperature and humidity change simultaneously, the humidity is undefined
Temperature change
+ 90°C to 0°C in 1 h
0 °C to - 40°C in 1 h
0 °C to + 90°C in 1 h
Humidity change
0 °C to + 90°C / 80 % r.h. in 1 h
+ 90°C / 80 % r.h. to 0°C in 1 h,
whereby the final dehumidification value is not defined.
Average temperature and humidity changes
If temperature and humidity change simultaneously, the humidity is undefined
Temperature change
+ 47°C to -30°C in 1 h
- 30°C to + 23°C in 1 h
+ 23°C to + 47°C in 1 h
Connections:
Nominal voltage 400 V +6/-10 %, 3/N, 50 Hz
Rated power 23 kW
Nominal current 49 A
Cekon 63 A plug
Connection cable approx. 3.5 m
Fuse protection 63 A, slow-blow on site
Installation room
Heated, with level floor
Heat output to the installation room approx. 7 kW
with radiation module switched on
Weight approx. 2000 kg
Condition: used
Scope of delivery: (see picture)
(Subject to changes and errors in the technical data and specifications!)
We will be happy to answer any further questions you may have over the phone.
Listing

18,513 km
Climate test chamber with humidity 64 liters
VötschVCL 4006 -40 bis + 180°C
Call
Condition: excellent (used), Vötsch
Type: VCL 4006
Vötsch temperature and climate test chamber, air-cooled
32 bit S!MPAC* control with touch panel
Potential-free contact for test material switch-off
Independent, adjustable temperature limiter tmin/tmax
Psychrometric humidity measurement system
TCP/IP interface
Large observation window
Test room lighting
1 pipe feed-through 50 mm
2 insertion grilles
Air-cooled cooling circuit
Humidification bath
Calibration of 2 temperature values and 2 humidity values
Test chamber capacity 64 liters
Performance for temperature tests -40 to + 180°C
Temperature deviation temporal ±0.3 to ±1.0 K
Temperature homogeneity in space ±0.5 to ±2.0 K
Rate of change
Heating 3.5 K/min
Cooling 5.0 K/min
Heat compensation max.800 W
Temperature calibration value +23 °C and +80 °C
Performance for climate tests VCL
Temperature range +10 to +95 °C
Humidity range 10 to 95%r.H.
Humidity deviation over time ±1 to ±3 %RH
Temperature deviation temporal ±0.3 to ±0.5 K
Temperature homogeneity in space ±0.5 to ±1.5 K
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 470 mm Depth 345 mm Height 400 mm
External dimensions: Width 760 mm Depth 980 mm Height 1070 mm
Sound pressure level: 56 dB(A)
Nominal power, max. 1.8 kW
Rated current: 8.0 A
Electrical connection: 1/N/PE AC 230 V ±10 %, 50 Hz
Refrigerant: R 404A
Weight: 235 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Duelqou Spxle Slanot
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Force gauge
Instron5982 mit AVE 2 Messtechnologie
Call
Condition: like new (used), Year of construction: 2019, Instron
Type: Instron Model 5982 floor model (extra height)
The system has only been used a little.
The furnace shown is unused and was built in 2021.
Universal mechanical testing machine INSTRON 5982 from 06/2019
with lots of accessories.
Applications:
Determination of mechanical properties of materials such as: tensile, compressive, bending, shear strength, etc.
Elastic modulus, shear modulus, elongation and hysteresis, fracture toughness
Technical data:
Measuring range: 100 kN
Accuracy and resolution of the load cell: < 0.5 N, linearity – < 0.03%, hysteresis: ± 0.002% nominal load
Crosshead displacement sensitivity: 0.001 mm (internal)
Delqevhbllj Slansut
Position control resolution: 9 nm
Overload capacity: approx. 120% nominal load
Display: via PC with Bluehill software + independent controller
Measurement frequency: up to 0.1 Hz to 1 kHz
Displacement speed: Under load: 0.001–1000 mm/min, without load: 0.001 –1100 mm/min
Max. crosshead travel: 1000 mm
Climate chamber for Tensile Testing:
Chamber for Soil Model System 3119-617
Temperature Rating -80°C to 350°C
Cooling option required to achieve sub-ambient temperatures.
Internal Dimensions 400mm x 400mm x 660mm
External Dimensions 550mm x 910mm
Measurement Technology AVE 2 2663-901
AVE 2
The second generation advanced video extensometer
(AVE 2, catalog number 2663-901) uses patented measurement technology in the fastest,
most accurate, non-contact strain measurement device on the market.
The fully integrated device is easily adapted to the normal environmental conditions in your laboratory as well as to any test device on the market.
Description:
Configuration E2-F1-G1
Capacity 100 kN
Measuring cell series 2580-100
Equipped with 2x product clamps up to 100 kN
Width between the columns 575 mm
Height of the columns 1930 mm
Overall dimensions; width 1130 mm height 2770 mm
Movable traverse
Adjustable limit switches
Wired digital control console
Touchscreen PC
Instron Bluehill software
240 volts 47-63 Hz 3500 VA 20 amp
Own weight 898 kg
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing

18,513 km
Electrodynamic vibration equipment
RMSTestmanager SWR 900 u. SWE 384 , SWE 366
Call
Condition: excellent (used), Here we offer electrodynamic vibration unit a RMS.
RMS electrodynamic vibration equipment
Test Manager SWR 900
Subrack SWE 348
Charge amplifier SWE 366
Charge amplifier SWE 366
PSU SWE 350
Type: Test Manager SWR 900
Condition: pre-owned / used
Scope of delivery: (See image)
Duoledyh E Hjq Slanst
(Errors and omissions in the technical data, information are reserved!)
We can answer questions on the phone for you.
Written order possible by email or fax
Listing

18,513 km
Tensile testing machine Table-top testing machine
Zwick / RoellBDO-FB0.5TH
Call
Condition: excellent (used), Here we offer you a Zwick / Roell tensile testing machine table-top testing machine.Zwick / Roell material testing machine BDO-FB0.5TH load in tensile / compression direction 500 N height 1565 mm , width 292 mm , depth 469 mmwidth of the test surface: infiniteTest range depth: 100 mmMax working stroke w.o. Accessories 1266 mmPC or printer interface RS 232Required PC connection (for PC operation) COM 1Performance data: 115/230 V (PH, N, PE)Rated power : 0.4 kVAN power frequency: 50/60 HzWeight: 47 kgType: BDO-FB0.5THCondition: used / usedScope supplied: (See picture)(Changes and errors in the technical data, details reserved!)We will be happy to answer any further questions you may have on the phone.
Duslq Slaed Sr S Isnst
Listing

18,513 km
Material oven 300 ° C 230V
BinderFP 115 mit forcierter Umluft 115 Liter
Call
Condition: excellent (used), Here we offer a Binder material test chamber with forced air circulation.
Binder material test chamber FP 115
Model: FP 115
Cabinet type: Material test cabinet
Internal volume: 115 l
Max. load: 11 - 50 kg
Maximum temperature (heat): + 300 °C
Internal width (incubators,...): 600 mm
Internal depth (incubators,...): 410 mm
Internal height (incubators,...): 480 mm
Width outside (incubators,...): 835 mm
External depth (incubators,...): 645 mm
External height (incubators,...): 705 mm
Item weight: 62.00 kg
Duolq Slod E I Areanot
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing

18,513 km
Temperature chamber TPK 200 280 liters
FeutronTyp: 3416/17 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a temperature test chamber.
Feutron temperature test chamber air-cooled
Nominal test chamber volume: 280 liters
Dimensions
Test chamber outside: width 1540 mm x height 2090 mm x depth 1240 mm
Fan motor and door removed: Width 1540 mm x height 1940 mm x depth 925 mm
Test chamber: Width 720 mm x height 690 mm x depth 560 mm
Door, clear width: width 720 mm x height 690 mm
Viewing window, heated: width 500 mm x height 600 mm
Installation dimensions of the temperature test chamber with open doors
Width 2340 mm x height 2090 mm x depth 2165 mm
Feed-through opening 2 side panels, left ∅ 100 mm
Temperature range
-70°C to +180°C
Heating: 3.0 K /min
Cooling: 3.0 K /min
Duslq Slajqxavajnet
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Max. power requirement: 6.3 kW
Weight: 635 kg
Type: 3416/17
Refrigerant: R507 / R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Temperature chamber
WEISSWT11-1000/70/5
Call
Condition: excellent (used), Weiss temperature chamber
Here we offer a Weiss temperature chamber.
Weiss temperature chamber air cooled with Weiss condenser cooler
Test chamber capacity approx. 990 liters
Data for temperature tests:
Temperature range -70°C to +180°C
Temperature deviation in time in the center of the chamber ± 0.1 to ± 0.5 K
Temperature deviation spatially ± 0.5 to ± 2.0 K
Temperature gradient (acc. to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating 5 K/min
Cooling 5 K/min
Heat compensation max. 2750 W
Feedthrough built into basic equipment
R1: NW 125 mm
L1: NW 50 m
Dimensions:
Test chamber dimensions: Width 1100 mm x depth 950 mm x height 950 mm
Housing dimensions: width 1390 mm x depth 1525 mm x height 1995 mm
maximum load (evenly distributed over the surface) of the test chamber floor 150 kg
per insert grate 50 kg
total load of the grate supports 100 kg
Data for operation:
Test room lighting halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 27,0 kW
Dslep Dun Aoq Slanjut
Rated current 42,02 A
Heat output water-cooled test chambers max. heat output to environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: ( converted to R-452a )
weight: approx. 960 kg
Type: WT11-1000/70/5
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. function check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

18,513 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control unit Water-cooled
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the
all control and operating commands by simply touching the function icons.
Levelling feet
Delq Sjrak Rmelaneut
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
(refrigerant converted to R-452A)
Test chamber capacity: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions: Height 950 mm, width 800 mm, depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 2500 W
Data for operation:
Test room lighting Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A Rated power 7.8 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front. 1m height 58 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Air-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Djlqsrak S Do Slaneut
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions: Height 950 mm, width 800 mm, depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 2500 W
Data for operation:
Test room lighting Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A Rated power 7.8 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front. 1m height 61 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make the search easier for you
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Measuring & testing equipment (1,325)
Search Machineseeker now with more than 200,000 used machines:This may be of interest to you

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month