Temperature Cooling Unit (TCU)Single
Water Advanced WP7
Temperature Cooling Unit (TCU)
Single
Water Advanced WP7
Condition
New
Location
Hochdorf 

Machine data
- Machine type:
- Temperature Cooling Unit (TCU)
- Manufacturer:
- Single
- Model:
- Water Advanced WP7
- Condition:
- new
Price & Location
- Rental:
- is possible
- Location:
- Ostring 17-19, 73269 Hochdorf, Deutschland

Call
Details about the offer
- Listing ID:
- A6050776
- Reference number:
- Water Advanced WP7
- Update:
- 21.11.2024
Description
*TECHNICAL SPECIFICATION:
Heating capacity: up to 54 kW
Cooling capacity: up to 300 kW
medium: water up to 200°C
Max. external volume: 43 ltr at 200°C
max. Flow rate: max. 230 l/min
max. delivery pressure: up to 8.3 bar
Motor power: up to 3 kW
Dimensions LxWxH: 1,460 x 525 x 1,200 mm
Weight approx. 330kg
Circulation medium connection: flange DN40 (DIN EN 1092-1), form B1
*HIGHLIGHTS EQUIPMENT:
-Control and regulation Smart Controller (7" touch display)
-Heating control via solid-state relay
-Control box IP54, externally ventilated
-Expansion tank, heater and piping stainless steel
-Heating via stainless steel tubular heating elements made of Incolloy
-Dirt trap (circulation)
-Unit ready for connection and mounted on castors, 2 of them steerable and with brake
-Cooling and filling controlled by solenoid valve
-configurable automatic filling via KW inflow or separate connection (factory-supplied via cooling water inflow)
-flow measurement by differential pressure principle
-Level monitoring by magnetic float switch
-automatic temperature-dependent system closure (not with WP7-90)
-flow monitoring by recording the flow rate
-Bypass between flow and return with reduced cross-section
-dirty filter in the cooling water inflow, filling and return of the circulation system
-Continuous bypass of the heat exchanger via 3-way motorised control valve (WP7-180/200)
-System pressure monitoring via pressure transmitter in the AD tank (WP7-150/180/200)
-Pressure booster pump for system filling (WP7-180/200, otherwise optional)
-Safety temperature limiter (STB) in the heater and flow (WP7-200)
-Pressure gauge in the supply line on the back of the unit
-heat-insulated circulation circuit (WP7-150/180/200)
Visit our website for more details or for other performance classes.
Iedpfx Akog Ey T Esgeba
*This unit is compliant with the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Heating capacity: up to 54 kW
Cooling capacity: up to 300 kW
medium: water up to 200°C
Max. external volume: 43 ltr at 200°C
max. Flow rate: max. 230 l/min
max. delivery pressure: up to 8.3 bar
Motor power: up to 3 kW
Dimensions LxWxH: 1,460 x 525 x 1,200 mm
Weight approx. 330kg
Circulation medium connection: flange DN40 (DIN EN 1092-1), form B1
*HIGHLIGHTS EQUIPMENT:
-Control and regulation Smart Controller (7" touch display)
-Heating control via solid-state relay
-Control box IP54, externally ventilated
-Expansion tank, heater and piping stainless steel
-Heating via stainless steel tubular heating elements made of Incolloy
-Dirt trap (circulation)
-Unit ready for connection and mounted on castors, 2 of them steerable and with brake
-Cooling and filling controlled by solenoid valve
-configurable automatic filling via KW inflow or separate connection (factory-supplied via cooling water inflow)
-flow measurement by differential pressure principle
-Level monitoring by magnetic float switch
-automatic temperature-dependent system closure (not with WP7-90)
-flow monitoring by recording the flow rate
-Bypass between flow and return with reduced cross-section
-dirty filter in the cooling water inflow, filling and return of the circulation system
-Continuous bypass of the heat exchanger via 3-way motorised control valve (WP7-180/200)
-System pressure monitoring via pressure transmitter in the AD tank (WP7-150/180/200)
-Pressure booster pump for system filling (WP7-180/200, otherwise optional)
-Safety temperature limiter (STB) in the heater and flow (WP7-200)
-Pressure gauge in the supply line on the back of the unit
-heat-insulated circulation circuit (WP7-150/180/200)
Visit our website for more details or for other performance classes.
Iedpfx Akog Ey T Esgeba
*This unit is compliant with the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2020
8 listings online
Send inquiry
Telephone & Fax
+49 7153 ... show
These listings may also fit your interest.
Listing
Italy
18,654 km
HAITIAN MA 2500 III
HAITIANMA 2500 III
HAITIANMA 2500 III
Listing
Wrocław
18,001 km
Injection molding machine
KraussMaffeiKM 850-12000 MX
KraussMaffeiKM 850-12000 MX
Listing
Germany
18,647 km
Bed Type Milling Machine - Universal
SORALUCETR 35
SORALUCETR 35
Listing
Dordrecht
18,611 km
Steering wheel
AJCEAVH30 Sheet Pile Vibro Hammer Pile Driver
AJCEAVH30 Sheet Pile Vibro Hammer Pile Driver
Listing
Nürtingen
18,613 km
Jig
+GF+FORM X600 + 3R Workpartner WPT1+
+GF+FORM X600 + 3R Workpartner WPT1+
Listing
Heroldstatt
18,600 km
Cylindrical grinding machine
Karstens GeneralüberholtK19 CNC 1000
Karstens GeneralüberholtK19 CNC 1000
Listing
Saarbrücken
18,716 km
Hexagon Optiv M 6.6.4 DUAL Z CMM
HexagonM 6.6.4 Dual Z
HexagonM 6.6.4 Dual Z
Listing
Aach
18,687 km
Machining center
MIKRONVCP 800 W
MIKRONVCP 800 W
Listing
Berlin
18,139 km
Vertical Injection Moulding Machine
ENGELe-insert 740H/60 single-C
ENGELe-insert 740H/60 single-C
Listing
Hochdorf
18,599 km
Temperature Cooling Unit (TCU)
SingleCompact WK3-160-9-50 (IM160F)
SingleCompact WK3-160-9-50 (IM160F)
Your listing has been deleted successfully
An error has occurred