Sartorius Tare CPA34001S Analytical BalanceSartorius Tare CPA34001S Analytical Balance
CPA34001S
Sartorius Tare CPA34001S Analytical Balance
Sartorius Tare CPA34001S Analytical Balance
CPA34001S
Condition
Used
Location
Duxford 

Show images
Show map
Machine data
- Machine type:
- Sartorius Tare CPA34001S Analytical Balance
- Manufacturer:
- Sartorius Tare CPA34001S Analytical Balance
- Model:
- CPA34001S
- Condition:
- used
Price & Location
- Location:
- Duxford, UK

Call
Details about the offer
- Listing ID:
- A20397945
- Reference number:
- 34674.SR8C
- Update:
- 21.01.2026
Description
This listing is for a Sartorius Tare CPA34001S Analytical Balance
The unit is in full working condition and is ready for immediate release.
This model offers a weighing capacity of up to ~34,000 g (34 kg) with a readability of 0.1 g.
It includes an automatic internal calibration (isoCAL) function, allowing the balance to self-calibrate at set intervals to maintain accuracy. The weigh cell is described as “monolithic weigh cell technology” which gives stability, precision and durability.
Large weigh pan: e.g., specification documents list a pan size of 400 × 300 mm for this model.
The housing is designed to be robust and chemical-resistant for tough lab environments.
Interface: it supports RS-232C / V24‐V28 serial interface for data logging, printing, external systems.
Fast response time: average response stated < 2 s in one specification sheet.
Tare function: full subtractive tare up to 100% of capacity is supported.
Technical Specifications (typical)
Based on the manual and spec sheet for this model:
Njdoxrt N Hjpfx Ad Nskt
Capacity (Max): 34,000 g (34 kg)
Scale interval (d): 0.1 g Linearity: ±0.2 g (typical)
Repeatability (standard deviation): ≤ 0.1 g
Pan size: ~400 × 300 mm
Dimensions (W × D × H): ~313 × 532 × 120 mm
Typical response time: ≤ 2 s
Operating ambient temperature with isoCAL: 0 °C to 40 °C; without: +10 °C to +30 °C (from manual)
Interface: RS-232C serial, 7-bit, various parity, 150-19200 baud.
Applications & Use-Case
Given its capacity (34 kg) and readability (0.1 g), this balance is suited for large-capacity analytical weighing rather than ultra-fine micro-weighing. Typical uses could include:
Weighing bulk samples, large containers or vessels (e.g., large drums, tanks) where still a good accuracy of 0.1 g is required.
Industrial laboratories, QA/QC, production where large items must be weighed with decent precision.
Situations where the weighing pan size needs to accommodate large items (400×300 mm is relatively large).
Environments where interface to computer/printer is needed for logging and traceability.
Where regular internal calibration is a benefit to maintain accuracy over time without frequent manual external weight calibration.
The unit is in full working condition and is ready for immediate release.
This model offers a weighing capacity of up to ~34,000 g (34 kg) with a readability of 0.1 g.
It includes an automatic internal calibration (isoCAL) function, allowing the balance to self-calibrate at set intervals to maintain accuracy. The weigh cell is described as “monolithic weigh cell technology” which gives stability, precision and durability.
Large weigh pan: e.g., specification documents list a pan size of 400 × 300 mm for this model.
The housing is designed to be robust and chemical-resistant for tough lab environments.
Interface: it supports RS-232C / V24‐V28 serial interface for data logging, printing, external systems.
Fast response time: average response stated < 2 s in one specification sheet.
Tare function: full subtractive tare up to 100% of capacity is supported.
Technical Specifications (typical)
Based on the manual and spec sheet for this model:
Njdoxrt N Hjpfx Ad Nskt
Capacity (Max): 34,000 g (34 kg)
Scale interval (d): 0.1 g Linearity: ±0.2 g (typical)
Repeatability (standard deviation): ≤ 0.1 g
Pan size: ~400 × 300 mm
Dimensions (W × D × H): ~313 × 532 × 120 mm
Typical response time: ≤ 2 s
Operating ambient temperature with isoCAL: 0 °C to 40 °C; without: +10 °C to +30 °C (from manual)
Interface: RS-232C serial, 7-bit, various parity, 150-19200 baud.
Applications & Use-Case
Given its capacity (34 kg) and readability (0.1 g), this balance is suited for large-capacity analytical weighing rather than ultra-fine micro-weighing. Typical uses could include:
Weighing bulk samples, large containers or vessels (e.g., large drums, tanks) where still a good accuracy of 0.1 g is required.
Industrial laboratories, QA/QC, production where large items must be weighed with decent precision.
Situations where the weighing pan size needs to accommodate large items (400×300 mm is relatively large).
Environments where interface to computer/printer is needed for logging and traceability.
Where regular internal calibration is a benefit to maintain accuracy over time without frequent manual external weight calibration.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2019
Send inquiry
Telephone & Fax
+44 20 38... show
These listings may also fit your interest.
Listing
Luckenwalde
18,173 km
✅MONO-CYCLONE Dust Extraction systems
PROTONMC 9
PROTONMC 9
Listing
Hradec Králové
18,116 km
Paint/spray booth
Reinoxmini 100x80
Reinoxmini 100x80
Listing
Russy-Bémont
18,913 km
Coperion extrusion line
COPERIONZSK 27 MV Plus
COPERIONZSK 27 MV Plus
Listing
Hradec Králové
18,115 km
Powder Coating Line
CoperionZSK 43 MV
CoperionZSK 43 MV
Listing
Zdziechowice
17,909 km
Dust extraction, dust collector, Ringler extractor
Ringler / Karcher GroupRE201 D5,5 IE3
Ringler / Karcher GroupRE201 D5,5 IE3
Listing
Sliven
17,430 km
Grinding system for powder coatings
NEUMAN & ESSERICM 19
NEUMAN & ESSERICM 19
Listing
Poznań
17,937 km
Wiege-und Verpackungsmaschine
PelettoTT-75
PelettoTT-75
Your listing has been deleted successfully
An error has occurred