Sartorius TareSartorius Tare CPA34001S Analytical Balance
CPA34001S
Sartorius Tare
Sartorius Tare CPA34001S Analytical Balance
CPA34001S
Condition
Used
Location
Duxford 

Show images
Show map
Machine data
- Machine type:
- Sartorius Tare
- Manufacturer:
- Sartorius Tare CPA34001S Analytical Balance
- Model:
- CPA34001S
- Condition:
- used
Price & Location
- Location:
- Duxford, UK

Call
Details about the offer
- Listing ID:
- A20397945
- Reference number:
- 34674.SR8C
- Update:
- 28.10.2025
Description
This listing is for a Sartorius Tare CPA34001S Analytical Balance
The unit is in full working condition and is ready for immediate release.
Nwsdpexrt N Hsfx Abren
This model offers a weighing capacity of up to ~34,000 g (34 kg) with a readability of 0.1 g.
It includes an automatic internal calibration (isoCAL) function, allowing the balance to self-calibrate at set intervals to maintain accuracy. The weigh cell is described as “monolithic weigh cell technology” which gives stability, precision and durability.
Large weigh pan: e.g., specification documents list a pan size of 400 × 300 mm for this model.
The housing is designed to be robust and chemical-resistant for tough lab environments.
Interface: it supports RS-232C / V24‐V28 serial interface for data logging, printing, external systems.
Fast response time: average response stated < 2 s in one specification sheet.
Tare function: full subtractive tare up to 100% of capacity is supported.
Technical Specifications (typical)
Based on the manual and spec sheet for this model:
Capacity (Max): 34,000 g (34 kg)
Scale interval (d): 0.1 g Linearity: ±0.2 g (typical)
Repeatability (standard deviation): ≤ 0.1 g
Pan size: ~400 × 300 mm
Dimensions (W × D × H): ~313 × 532 × 120 mm
Typical response time: ≤ 2 s
Operating ambient temperature with isoCAL: 0 °C to 40 °C; without: +10 °C to +30 °C (from manual)
Interface: RS-232C serial, 7-bit, various parity, 150-19200 baud.
Applications & Use-Case
Given its capacity (34 kg) and readability (0.1 g), this balance is suited for large-capacity analytical weighing rather than ultra-fine micro-weighing. Typical uses could include:
Weighing bulk samples, large containers or vessels (e.g., large drums, tanks) where still a good accuracy of 0.1 g is required.
Industrial laboratories, QA/QC, production where large items must be weighed with decent precision.
Situations where the weighing pan size needs to accommodate large items (400×300 mm is relatively large).
Environments where interface to computer/printer is needed for logging and traceability.
Where regular internal calibration is a benefit to maintain accuracy over time without frequent manual external weight calibration.
The unit is in full working condition and is ready for immediate release.
Nwsdpexrt N Hsfx Abren
This model offers a weighing capacity of up to ~34,000 g (34 kg) with a readability of 0.1 g.
It includes an automatic internal calibration (isoCAL) function, allowing the balance to self-calibrate at set intervals to maintain accuracy. The weigh cell is described as “monolithic weigh cell technology” which gives stability, precision and durability.
Large weigh pan: e.g., specification documents list a pan size of 400 × 300 mm for this model.
The housing is designed to be robust and chemical-resistant for tough lab environments.
Interface: it supports RS-232C / V24‐V28 serial interface for data logging, printing, external systems.
Fast response time: average response stated < 2 s in one specification sheet.
Tare function: full subtractive tare up to 100% of capacity is supported.
Technical Specifications (typical)
Based on the manual and spec sheet for this model:
Capacity (Max): 34,000 g (34 kg)
Scale interval (d): 0.1 g Linearity: ±0.2 g (typical)
Repeatability (standard deviation): ≤ 0.1 g
Pan size: ~400 × 300 mm
Dimensions (W × D × H): ~313 × 532 × 120 mm
Typical response time: ≤ 2 s
Operating ambient temperature with isoCAL: 0 °C to 40 °C; without: +10 °C to +30 °C (from manual)
Interface: RS-232C serial, 7-bit, various parity, 150-19200 baud.
Applications & Use-Case
Given its capacity (34 kg) and readability (0.1 g), this balance is suited for large-capacity analytical weighing rather than ultra-fine micro-weighing. Typical uses could include:
Weighing bulk samples, large containers or vessels (e.g., large drums, tanks) where still a good accuracy of 0.1 g is required.
Industrial laboratories, QA/QC, production where large items must be weighed with decent precision.
Situations where the weighing pan size needs to accommodate large items (400×300 mm is relatively large).
Environments where interface to computer/printer is needed for logging and traceability.
Where regular internal calibration is a benefit to maintain accuracy over time without frequent manual external weight calibration.
Seller