Used Climate Test Chamber, Climatic Chamber for sale (15,621)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
18,513 km
Climate test chamber 350 liters with humidity control
CTSC -40/350 -40°C /+180°C
Call
Condition: excellent (used), CTS
Type: C-40/350
Air-cooled Climate Test Chamber
For sale is a professional CTS climate test chamber, model C-40/350. This device is designed for demanding environmental simulations in industrial applications and is ideal for material testing, electronics, automotive, aerospace, and research.
Temperature Testing:
- Temperature range: -40°C to +180°C
- Temperature deviation: ≤ ±0.3 K over time
- Temperature change rate according to IEC 60068-3-5:
- Heating: 3.5 K/min
- Cooling: 4 K/min
- Heat compensation:
- Approx. 3500 W at +20°C
- Approx. 2000 W at -20°C
Climatic Testing:
- Temperature range: +10°C to +90°C
- Humidity range: 10% to 95% relative humidity
- Dew point range: +5°C to +78°C
- Temperature deviation: ≤ 1.0 K over time
- Humidity deviation: ≤ ±3.0% r.h. over time
Technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without heat compensation, and without additional accessories. Options may influence performance data.
Technical Specification:
- Refrigeration unit: Air-cooled, low-noise, fully hermetic, infinitely variable performance adjustment via electronic monitoring and control system, environmentally friendly refrigerant R404A
- Test chamber floor load: 150 kg/m²
- Shelf: Stainless steel, support surface 620 x 600 mm
- Maximum load per shelf: 35 kg
- Total load with maximum number of shelves: 100 kg
Control:
- 32-bit controller
- LCD control panel
- Digital display of setpoint and actual values
- Numeric entry of setpoints
- Plain-text error messages
- RS 232 interface
- Ethernet interface
- Free switching channels for external test sample control
Dimensions:
- Test volume: 350 liters
- Internal dimensions: Height 750 mm × Width 650 mm × Depth 720 mm
- External dimensions: Height 1800 mm × Width 920 mm × Depth 1670 mm
Operating Data:
- Electrical connection: 400V 3/N, 50 Hz
- Rated power: 7.1 kW
Cjdozizmzepfx Ailsrd
- Rated current: 11.5 A
- Protection class: IP 54
- Sound pressure level:
Listing
Borken
18,513 km
Climate test chamber 5,500 liters (5.5 m³)
CTSCW-60/5,5 -60°C bis +100°C
Call
Condition: excellent (used), CTS CW-60/5.5 – Water-cooled Climate Test Chamber
The CW-60/5.5 from CTS GmbH (Climatic Test Systems) is a medium-sized, walk-in and drive-in climatic chamber designed for simultaneous temperature and humidity testing on multiple test specimens.
Device Description
The climate test chamber allows for functionality or material property testing of a test item under the influence of temperature and humidity. Efficient air circulation with a correspondingly high level of recirculating air volume ensures excellent transfer to the test item. The air treatment compartment is located at the rear of the test chamber. The aggregates are positioned behind the unit in a separate frame for easy access. The control system is integrated into a separate control cabinet. The control panel is mounted in the door of the control cabinet. For dehumidification, the test chamber is equipped with a self-regenerating compressed air dryer. The test chamber can also be purged with fresh air via an internal blower.
Technical Specifications:
Temperature Testing:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ±0.5 to 1 K over time
- Temperature change rate, linear with specimen and heat radiation, measured in supply air:
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climatic Testing:
- Temperature range: +10 °C to +90 °C
- Humidity range: 10% to 95% rH
- Dew point range: +5 °C to +89 °C
- Temperature deviation: ±0.5 K over time
- Humidity deviation: ±1 – ±3% rH over time
Technical data refer to an ambient temperature of +25 °C, nominal voltage 400 V, without test item, without external radiation and without additional devices.
Dimensions:
Internal dimensions (test space/usable volume):
- Volume: approx. 5,500 liters (5.5 m³)
- Internal dimensions (approx.): Height: 2,300 mm, Width: 1,600 mm, Depth: 1,550 mm
External dimensions: Height: 2,800 mm, Width: 2,250 mm, Depth: 5,000 mm
Operating Data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Nominal power: 58.3 kW (incl. 5 sockets)
- Nominal current: 86.0 A
- Protection rating: IP 54
Technical Execution:
Refrigeration unit:
Water-cooled, low noise, semi-hermetic, infinitely variable capacity adjustment via electronic monitoring and control system, environmentally friendly refrigerants R 23 / R 404 A
Cedpfx Aezizmujilsrd
Notes:
Inspection by appointment possible (46325 Borken)
Shipping by forwarding agent possible – Costs & organization upon request
Scope of delivery: (see photo)
(Subject to change and possible errors in the technical data; information provided without liability!)
For further questions, we are happy to assist you via telephone.
Listing
Borken
18,513 km
Climate test chamber 5,500 liters (5.5 m³)
CTSCW-60/5,5 -60°C bis +100°C
Call
Condition: excellent (used), CTS CW‑60/5.5 – Water-Cooled Climate Test Chamber
The CW‑60/5.5 from CTS GmbH (Climatic Test Systems) is a mid-sized, walk-in or drive-in climate chamber designed for conducting temperature and humidity tests on multiple test specimens simultaneously.
Equipment Description
This climate test chamber allows you to assess the function or material properties of test objects under controlled temperature and humidity conditions. Efficient air circulation with a high re-circulation rate ensures excellent transfer to the test goods. The air handling system is located at the rear of the inner chamber. All of the aggregates are mounted in a separate frame behind the unit, providing easy access. The control system is housed in a separate switch cabinet, while the user interface is integrated into the cabinet door.
To dehumidify the test chamber, it is equipped with a self-regenerating compressed air dryer. Fresh air can be supplied by a blower to purge the chamber as required.
Technical Specifications:
Crsdjzizmnjpfx Ailsd
Temperature Testing:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ±0.5 to 1 K over time
- Temperature change rate (linear with test specimen and radiant heat, measured at supply air):
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climatic Testing:
- Temperature range: +10 °C to +90 °C
- Humidity range: 10% to 95% relative humidity
(dew point range +5°C to +89 °C)
- Temperature deviation: ±0.5 K over time
- Humidity deviation: ±1 to ±3 % r.h. over time
Technical data based on ambient temperature of +25 °C, rated voltage 400 V, without test specimen, without radiant heat, and without additional equipment.
Dimensions:
Internal dimensions (test/useable space):
- Volume: approx. 5,500 liters (5.5 m³)
- Internal dimensions (approx.): Height 2300 mm, Width 1600 mm, Depth 1550 mm
External dimensions:
- Height 2800 mm, Width 2250 mm, Depth 5000 mm
Operating Data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Rated power: 58.3 kW (incl. 5 sockets)
- Rated current: 86.0 A
- Protection category: IP 54
Technical Design:
- Refrigeration unit: water-cooled, low-noise, semi-hermetic, stepless power adjustment via electronic monitoring and control system
- Environmentally friendly refrigerants: R 23 / R 404 A
Notes:
- Inspection possible by appointment (46325 Borken)
- Shipping by freight forwarding possible – costs & organization on request
- Scope of delivery: (see picture)
- (Subject to modifications and errors in technical data, all information provided without guarantee!)
For further questions, we are happy to assist you by phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
18,513 km
Climate test chamber 5,500 liters (5.5 m³)
CTSCW-60/5,5 -60°C bis +100°C
Call
Condition: excellent (used), CTS CW‑60/5.5 – Water-Cooled Climate Test Chamber
The CW‑60/5.5 from CTS GmbH (Climatic Test Systems) is a mid-sized, walk-in or drive-in climate chamber designed for conducting temperature and humidity tests on multiple test specimens simultaneously.
Cjdpfx Aiszizmbelsrd
Equipment Description
This climate test chamber allows you to assess the function or material properties of test objects under controlled temperature and humidity conditions. Efficient air circulation with a high re-circulation rate ensures excellent transfer to the test goods. The air handling system is located at the rear of the inner chamber. All of the aggregates are mounted in a separate frame behind the unit, providing easy access. The control system is housed in a separate switch cabinet, while the user interface is integrated into the cabinet door.
To dehumidify the test chamber, it is equipped with a self-regenerating compressed air dryer. Fresh air can be supplied by a blower to purge the chamber as required.
Technical Specifications:
Temperature Testing:
- Temperature range: -60 °C to +100 °C
- Temperature deviation: ±0.5 to 1 K over time
- Temperature change rate (linear with test specimen and radiant heat, measured at supply air):
- Heating: 2 K/min from -40 °C to +85 °C
- Cooling: 2 K/min from +85 °C to -40 °C
Climatic Testing:
- Temperature range: +10 °C to +90 °C
- Humidity range: 10% to 95% relative humidity
(dew point range +5°C to +89 °C)
- Temperature deviation: ±0.5 K over time
- Humidity deviation: ±1 to ±3 % r.h. over time
Technical data based on ambient temperature of +25 °C, rated voltage 400 V, without test specimen, without radiant heat, and without additional equipment.
Dimensions:
Internal dimensions (test/useable space):
- Volume: approx. 5,500 liters (5.5 m³)
- Internal dimensions (approx.): Height 2300 mm, Width 1600 mm, Depth 1550 mm
External dimensions:
- Height 2800 mm, Width 2250 mm, Depth 5000 mm
Operating Data:
- Electrical connection: 400 V +6/-10%, 3/N, PE, 50 Hz
- Rated power: 58.3 kW (incl. 5 sockets)
- Rated current: 86.0 A
- Protection category: IP 54
Technical Design:
- Refrigeration unit: water-cooled, low-noise, semi-hermetic, stepless power adjustment via electronic monitoring and control system
- Environmentally friendly refrigerants: R 23 / R 404 A
Notes:
- Inspection possible by appointment (46325 Borken)
- Shipping by freight forwarding possible – costs & organization on request
- Scope of delivery: (see picture)
- (Subject to modifications and errors in technical data, all information provided without guarantee!)
For further questions, we are happy to assist you by phone.
Listing
Borken
18,513 km
Climate test chamber +20 to +130°C, 240 l
Weiss TechnikEmissionEvent VOC/240
Call
Condition: excellent (used), Weiss
Type: EmissionEvent VOC/240
Weiss Technik EmissionEvent VOC/240
Industrial Emission Test Chamber / VOC Test Chamber / Climatic Test Cabinet
Water-cooled
A professional emission test chamber is offered for sale
Weiss Technik EmissionEvent VOC/240 (Year of manufacture: 2018)
from an industrial laboratory and testing operation.
The device is designed for conducting standardized emission tests under precisely controlled temperature,
climatic, and process conditions, and is built for continuous use in laboratories, industrial settings, and quality assurance.
What does VOC mean / What does the device do?
VOC = Volatile Organic Compounds
The device measures and tests the outgassing (emissions) of materials under defined conditions.
It analyses which substances are released into the air by a given material. Typical applications include:
- Emission testing of plastics, components, materials
- Automotive interior material testing (odor / pollutants)
- Building products & furniture emission measurement
- Packaging, textiles, adhesives, paints
- Quality control and standard testing (e.g. ISO / VDA / DIN)
The test system generates precisely defined temperature, humidity, and air conditions.
Emissions are extracted from the test space using a carrier gas (e.g. nitrogen or air)
and can subsequently be analyzed using appropriate measuring equipment.
Device features / Equipment:
- Stainless steel emission test chamber (hermetically sealed)
- Temperature and climate control
- Carrier gas system for emission measurement
- Automatic process control with touch panel
- Programmable operation / continuous operation possible
- Sampling ports for VOC analysis
Cedpfx Aieziyz Rjljrd
- Industrial-grade construction (suitable for laboratory and continuous operation)
Technical data for temperature testing:
- Temperature range: +20 to +130 °C
- Temporal temperature deviation at chamber center: ±0.1 to ±0.3 K
- Spatial temperature uniformity: ±0.1 to ±0.5 K
- Temperature change rate (according to IEC 60068-3-5):
Heating: 0.4 K/min
Cooling: 0.3 K/min
- Temperature change rate (average, with enhanced heating and cooling capacity):
Heating up to +65 °C: 1.5 K/min
Cooling from +65 °C to +20 °C: 1.3 K/min
Technical data for climate testing:
- Temperature range: +20 to +130 °C
- Dew point range: +5 to +60 °C
- Relative humidity range: 5 to 95% RH
- Temporal temperature deviation: 0.1 to 0.3 K
- Temporal humidity deviation: -3 to 3% RH
Dimensions EmissionEvent VOC/240
External dimensions (unit):
Width: approx. 1350 mm, Depth: approx. 2500 mm, Height: approx. 1985 (2190) mm
Internal dimensions (test space):
Emission test chamber: 200 l
Gross test chamber volume: 240 l
Net test chamber volume: 208 l
Max. test sample load: 80 kg
Internal dimensions VOC/240:
Width: approx. 600 mm, Depth: approx. 560 mm, Height: approx. 600 mm
Electrical:
Voltage: 3/N/PE AC 400 V ±10% / 50 Hz
Nominal power: 12.1 kW
Nominal current: 30 A
Protection class: IP54
Refrigerant:
R134a – 2.5 kg
Weight: approx. 1080 kg
Important information for you as the buyer:
The following procedures are carried out on the chambers we offer prior to sale:
1. Functional inspection and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Following successful inspection, a documented trial run is carried out
Condition: used
Scope of supply: (see picture)
(Technical data and specifications subject to change and errors!)
For further questions, feel free
Listing
Borken
18,513 km
Climate test chamber with humidity, 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Weiss
Model: WK3-340/40
Weiss Climate Test Chamber, Air-Cooled
Temperature Testing
Volume: 335 liters
Test Chamber Dimensions:
Internal Dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External Dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Minimum Temperature: –42°C
Maximum Temperature: +180°C
Crsdpfx Aeziyygjiljd
Temperature Change Rate, Cooling: 4 K/min
Temperature Change Rate, Heating: 3.2 K/min
Temperature Deviation Over Time: ± 0.1 to ± 0.5 K
Temperature Uniformity Spatially: ± 0.5 to ±1.5 K
Climate Testing:
Temperature Range: +10°C to +95°C
Dew Point Range: -3°C to +94°C
Humidity Range: 10 to 98% RH
Temperature Deviation Over Time: ± 0.1 to ± 0.3 K
Temperature Uniformity Spatially: ± 0.5 to ± 1 K
Humidity Deviation Over Time: ± 1 to ± 3 % RH
Halogen Lamp: 2 x 24V, 50W
Voltage: 3/N/PE AC 400V ±10% 50Hz
Rated Power: 4.1 kW, Rated Current: 14 A
Refrigerant: R-404A
Weight: approx. 515 kg
For your security as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications reserved!)
Further questions can be answered by phone.
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
With temperature change rate of 5 K/min
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Crodpfxsziyx No Ailsd
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Refrigerant: R404A / R-23
Weight approx. 570 kg
For your security as a buyer, please note the following:
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Credjziyxispfx Ailjd
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Borken
18,513 km
Climatic test chamber -5°C...+90°C
WeissWK111-600 600 Liter
Call
Condition: used, Weiss
Type: WK111-600
Cjdpfxsziyxcs Ailjrd
Weiss Climate Test Chamber, Air-cooled
Performance Data for Temperature Tests:
Temperature range: -5°C to +90°C
Temporal temperature fluctuation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1 K
(corresponds to temperature gradient): 1 to 2 K
Temperature change rate:
Heating: 0.5 K/min
Cooling: 0.2 K/min
Performance Data for Climatic Tests:
Temperature range: +10 to +90°C
Humidity range: 10 to 98% r.h.
Temporal temperature fluctuation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
(corresponds to temperature gradient): 1 to 2 K
Temporal humidity fluctuation: ±1 to ±3%
Test Chamber Dimensions: Width 800 mm x Depth 800 mm x Height 950 mm
Housing Dimensions: Width 1000 mm x Depth 1660 mm x Height 1975 mm
Access Ports:
1 access port Ø 50 mm on the left side installed
1 access port Ø 125 mm on the right side installed
Power Supply: 1/N/PE AC 230V ±10% 50Hz
Rated power: 2.3 kW
Rated current: 10.0 A
Refrigerant: R 404 A
Capacity: 600 liters
Weight: 540 kg
For your security as a buyer, please note the following information!
The following steps are performed on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors excepted!)
If you have further questions, feel free to contact us by phone.
Listing
Borken
18,513 km
Climate test chamber with humidity
CTSCS-70/350 350 Liter -70°C /+180°C
Call
Condition: excellent (used), Here we offer you a climate chamber.
Water-cooled
Test chamber volume: 350 liters
Internal chamber dimensions: Height 750 mm, Width 650 mm, Depth 720 mm
External dimensions: Height 1800 mm, Width 850 mm, Depth 1640 mm
Temperature working range:
Temperature range: -70°C to +180°C
Cooling rate: 3.0 K/min
Crjdpjziyw Esfx Ailod
Heating rate: 5.0 K/min
Climate working range:
Temperature range: +10°C to +90°C
Humidity range: +10% to 98% RH
Dew point range: +5°C to 89.5°C
Temperature deviation: ±0.1 - ±0.3 K over time
Humidity deviation: ±1 - ±2% RH over time up to 90% RH
max. ±1 - 3% RH over time above 90% RH
Electrical connection: 400V +6-10%, 3/N, 50Hz
Connected load: 13 kW
Rated current: 25.5 A
Refrigerant: R404A / R23
Weight: 650 kg
Type: CS-70/350
For your safety as a buyer, please note the following information:
The following steps are performed in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a trial run which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (see photo)
(Specifications, technical data and details may be subject to change. Errors excepted.)
For any further questions, we are happy to assist you by phone.
Listing
Borken
18,513 km
Climate test chamber 600 liters with humidity
WeissWK3-600/0-M -5°C bis +90°C
Call
Condition: excellent (used), Weiss
Model: WK3 600/0-M
Weiss Climate Test Chamber, Water-Cooled
Series: WK3-../0
with SIMPAC* Controller
Test chamber volume: approx. 600 liters
Test chamber dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
External dimensions: Height 1995 mm, Width 1090 mm, Depth 1660 mm
Operating data:
Test chamber lighting: LED 24 V, 6.8 W / Halogen bulb 2 x 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 2.3 kW
Rated current: 10 A
Site-provided fuse: 16 A slow-blow
Control cabinet and operator panel protection class: IP 54
Maximum heat emission to environment: 1200 W
Sound pressure level:
Measured at a distance of 1m from the front, at a height of 1.6m: 46 dB(A)
Data for temperature tests:
Temperature range: -5°C to +90°C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temperature gradient (according to IEC 60068-3-5)
Temperature change rate:
Heating 0.6 K/min
Cooling 0.3 K/min
Heat compensation at +20°C to +50°C: 200 W
Data for climatic tests:
Temperature range: +10°C to +90°C
Dew point range: 4 to +89.5°C
Humidity range: 10 to 98 % r.h.
Crsdpfx Aioziywrjlod
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temporal humidity deviation: +1 to +3 % r.h.
Refrigerant: R-404A
Weight: 610 kg
For your safety as a buyer, please note the following information!
The following points are carried out in advance on our offered chambers:
1. Functionality check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Technical data and information subject to change and errors!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
18,513 km
Climate test chamber with humidity
VötschVC³ 0100 0°C bis + 90°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 0100
Vötsch Climate Test Chamber, Air-Cooled
Internal Test Chamber Dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall Device Dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Test Chamber Volume: 990 litres
Temperature Testing:
Minimum Temperature: -0°C
Maximum Temperature: +90°C
Temperature Change Rate, Cooling: 0.2 K/min
Temperature Change Rate, Heating: 0.5 K/min
Temporal Temperature Deviation: ±0.1 to ±0.5 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Heat Compensation at +20 °C: 350 W
Credpfx Asziypueiljd
Climatic Testing:
Minimum Temperature: +10°C
Maximum Temperature: +90°C
Dew Point Temperature Range: +4°C to +89.5°C
Humidity Range: 10 to 98% r.h.
Temporal Humidity Deviation: ±1 to ±3% r.h.
Temporal Temperature Deviation: ±0.1 to ±0.3 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Refrigerant: R-404A
Weight: approx. 1400 kg
Important information for you as a buyer:
The following measures are carried out on our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and error!)
For further questions, we are happy to assist you by phone.
Listing
Borken
18,513 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Codpfjziypnox Ailord
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Port openings: Ø 125 mm, Ø 50 mm
Temperature test specifications:
Temperature range: -42°C to +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Max. heat compensation at +20°C: 4500 watts
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1% to ± 3% r.h.
Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
For your security as a buyer, please note the following information!
The following points are checked and carried out on all our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. If needed, fresh filling with legally compliant refrigerant
3. Leak check with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Subject to prior sale, changes and errors in technical data and specifications reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
18,513 km
Battery test system with climate chamber
Keysight / Scienlab / AngelantoniBatterie-Testsystem SL1001A
Call
Condition: used, Keysight / Scienlab Battery Test System SL1001A + Angelantoni Climate Chamber DM500 C 10 ESS SPEEDY BT SP
Complete Battery Testing System – For Laboratory Use
Incl. PC, software & technical documentation
For sale is a professional battery test system, consisting of:
- Keysight / Scienlab SL1001A Battery Test System
Cedpfx Aijzil Txelerd
- Angelantoni DM500 C 10 ESS SPEEDY BT SP Climate Chamber
- Monitoring/Sampling Unit
- Control PC with original software
- Technical documentation
The system is fully functional, well-maintained, and ideally suited for battery module testing, research, development, and quality assurance.
Technical Data – Scienlab SL1001A:
- Manufacturer: Keysight / Scienlab
- Model: SL1001A
- Year of manufacture: 2020
- Voltage / Current / Power: 80 V / 600 A / 24 kW
- Dimensions (L×W×H): approx. 1.6 × 0.9 × 3.3 m
- Weight: approx. 700 kg
- Function: Charging, discharging, and cycling of battery modules
- Condition: Very well maintained, laboratory use only
Technical Data – Angelantoni DM500 C 10 ESS SPEEDY BT SP:
- Manufacturer: Angelantoni Industrie S.r.l., Italy
- Model: DM500 C 10 ESS SPEEDY BT SP
- Year of manufacture: 2019
- Weight: approx. 1,225 kg
- Temperature range: -70 °C ... +180 °C
- Humidity range: 10 ... 98 % rH
- Refrigerants: R449A + R23
- Pressure ranges (PS Hi/Lo): 28 bar / 8 bar
- Wi-Fi integrated
- CE certification present
- Internal dimensions (L×W×H): approx. 1.6 × 2.3 × 3.3 m
- Function: Temperature and humidity testing, ESS (Environmental Stress Screening)
- Power supply: 3PH + N + PE, 400 V ±10 %, 50 Hz, full load 54 A
- Max. power consumption: 32.5 kW
Monitoring / Sampling Unit:
- Dimensions: 0.6 × 0.5 × 0.2 m
- Measured variables: Cell voltages, current, temperature
- Interfaces: CAN, Ethernet
- Compatible with Scienlab / Keysight PathWave software
PC + Software + Documentation:
- Industrial PC with control and measurement software
- Enables automated test runs, logging, and data analysis
Overall Dimensions / Weight (approx.):
Component Dimensions (L×W×H) Weight
Scienlab SL1001A 1.6 × 0.9 × 3.3 m 700 kg
Angelantoni Chamber 1.6 × 2.3 × 3.3 m 1,225 kg
Monitoring / PC 0.6 × 0.5 × 0.2 m 50 kg
Total system L 3.2 m × W 2.5 m × H 3.3 m approx. 1,975 kg
Applications:
- Development, testing, and lifespan analysis of battery modules (e.g., Li-ion, LFP, NMC)
- Fast charging and cycle tests
- Environmental simulation for temperature and humidity
- Research, industrial, and university laboratories
Important Note:
"The table shown in the photos is not included in the sale."
Scope of Delivery:
- Scienlab SL1001A power unit
- Angelantoni DM500 C 10 ESS SPEEDY BT SP climate chamber
- Monitoring/Sampling unit
- Control PC with software
- Technical documentation and manuals
- Connection cables and accessories (as available)
Condition: used
Scope of delivery: (see image)
(Specifications and data are subject to change and error!)
For any further questions, we are happy to assist you by phone.
Listing
Borken
18,513 km
Climate test chamber 900 liters
CTSCS-70/900 -70...+180°C
Call
Condition: used, Type: CS-70/900
CTS Climate Test Chamber with Humidity, water-cooled
(converted to R-452a refrigerant)
Temperature range: -70°C to +180°C
Crsdpfxjziizte Ailjd
Humidity range: 10–98% RH
Test chamber internal dimensions: Height approx. 870 mm / Width approx. 1000 mm / Depth approx. 1000 mm
External dimensions: Height approx. 1950 mm / Width approx. 1200 mm / Depth approx. 2220 mm
Control cabinet dimensions: Height approx. 2100 mm / Width approx. 800 mm / Depth approx. 400 mm
Test chamber volume: 900 liters
Refrigerant: R-452a / R23
Electrical connection: 400 V +6/-10%, 3/N, 50 Hz
Connected load: 21.2 kW, Rated current: 35.7 A
Chamber weight: 900 kg
Control cabinet weight: 150 kg
Important safety information for buyers:
The following steps are carried out on all chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilled with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see photo)
(Specifications and technical data subject to change and errors reserved!)
For any further questions, please contact us by phone.
Listing
Borken
18,513 km
Climate test chamber with solar simulation
Atlas / WeissSolarClimatic SC-340
Call
Condition: excellent (used), Atlas
Type: SC 350 MHG
Atlas Solar Climatic Test Chamber, Air-Cooled
For sale is an ATLAS SC-340 MHG SolarClimatic Test Chamber
Crodpfxeziizms Ailed
(climatic chamber with solar simulation via MHG lamp).
The device is suitable for carrying out standardized weathering and aging tests under the combined influence of radiation, temperature, and climate.
Features & Highlights:
- Precise temperature and humidity control
- Integrated humidification system with water reservoir
- Cooling via water or air system (optional)
- Feed-throughs available for measuring leads
- Control via control panel or interfaces (RS232, etc.)
- Sturdy test chamber floor, loadable up to 60 kg (optionally reinforced to 150 kg)
General Data:
Model: SC 340 MHG
Test chamber volume: approx. 335 liters
Cabinet weight: approx. 500 kg
Irradiation unit weight: approx. 65 kg
Technical Data:
Test volume: 340 l (internal dimensions 580 × 765 × 750 mm)
External dimensions (W×D×H): 865 × 1,595 × 2,180 mm
Light source: 1 × 1,200 W MHG lamp
Irradiance: 800–1,200 W/m²
Illuminated area: approx. 3,300 cm²
Weathering spectrum: 300–3,000 nm, compliant tests according to DIN 75220, IEC 60068-2-5, MIL-STD-810F
Temperature range with irradiation: –20 °C to +100 °C (±1 K)
Temperature range without irradiation: –30 °C to +100 °C (±0.1–0.5 K)
Heating/Cooling rates: 3.0 K/min (heating), 2.5 K/min (cooling, without irradiation)
Noise level: approx. 58 dB(A) at a distance of 1 m
Power supply: 400 V, 3/N/PE, 50 Hz
Power consumption: max. 6.2 kW, 16 A
Refrigerant: R-404A
Weight: approx. 565 kg
Information for your safety as a buyer!
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers are subjected to a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Specifications and technical details subject to change and errors reserved!)
Feel free to contact us by phone for any further questions.
Listing
Borken
18,513 km
Climatic test chamber with humidity, 600 liters
CTSC-40/600 -40 bis +180°C
Call
Condition: excellent (used), CTS Climate Test Chamber Type: C -40/600, Air-Cooled
(converted to R-452a refrigerant)
Test chamber volume: 600 liters
Temperature tests:
- Temperature range: -40°C to +180°C
- Temperature deviation: ±0.1 K / ±0.3 K over time (at stabilized condition)
- Average temperature rate of change (without test load and radiant heat):
- Heating: 2.5 K/min
- Cooling: 3.0 K/min
- Maximum radiant heat input: 2500 W at +20°C
Climatic tests:
- Climate range / Technical data:
- Temperature range: +10°C to +95°C
- Humidity range: 10% r.h. to 98% r.h.
- Dew point range I: +7°C to +94°C
- Dew point range II: –10°C to +7°C
- Consistency values (over time):
- Humidity consistency I: ±0.5% r.h. to ±1.5% r.h.
- Humidity consistency II: ±1% r.h. to ±3% r.h.
- Temperature consistency: ±0.1 K to ±0.3 K
Chamber internal dimensions (approx.): Height: 850 mm, Width: 850 mm, Depth: 830 mm
External dimensions (approx.): Height: 1900 mm, Width: 1115 mm, Depth: 1850 mm
Refrigerant: R-452A
Power connection: 400V 3/N 50Hz
Connected load: 8.2 kW, Rated current: 11.9 A
Weight: 550 kg
Important information for your purchase!
The following checks and procedures are performed on all our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
Crodpfx Aisziizgjlod
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in the technical data and specifications!)
If you have further questions, we will be happy to answer them by phone.
Listing
Borken
18,513 km
Climatic test chamber 800 L, -55°C to +180°C
WeissClimeEvent C/800/55a/25/S 25K/min
Call
Year of construction: 2020, condition: excellent (used), Weiss
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Temperature range: -55 to +180°C
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Codjziiypepfx Ailord
Rated current: 87 A
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
For further questions, we are happy to answer your call.
Listing
Borken
18,513 km
Climatic test chamber shaker chamber 2160 liters
WeissWK3-2200/40/5/V -40°C bis +180°C
Call
Condition: excellent (used), Weiss
Type: WK3-2200/40/5/V
Weiss Climate Test Chamber, Water-Cooled
Specifications for Temperature Testing:
Temperature range: -40°C to +180°C
Temperature change rates:
Heating: 6.0 K/min
Cooling: 11.5 K/min
Temperature deviation:
Temporal ± 0.8 K
Spatial ± 2.0 K
Heat compensation max. 8000 W
Credpfx Aieziixrjlsd
Specifications for Climatic Testing:
Temperature range: +10°C to +95°C
Dew point temperature range: +4°C to +94°C with closed floor element
Humidity range: 10 to 95% rH
Temperature deviation (temporal): ± 0.3 K
Humidity deviation (temporal): ± 3% rH
Temperature uniformity:
Spatial ± 1.0 K
Heat compensation max.: 500 W
Test chamber volume: 2,160 liters
Test chamber dimensions: Height 1,115 mm, Width 1,400 mm, Depth 1,400 mm
External dimensions (lowered): Height 2,318 mm, Width 1,860 mm, Depth 3,658 mm
External dimensions above shaker: Height 2,710 mm
External dimensions max. stroke height: 3,038 mm
Exchangeable floor dimensions: Width 1,600 mm, Depth 1,504 mm
Operating Data:
Rated voltage: 3/N/PE AC 400V +10% 50Hz
Rated power: 38.0 kW
Rated current: 63.0 A
Customer-side fuse: 80 A slow-blow
Refrigerant: R 404A
Weight: approx. 2,100 kg
Important information for your safety as a buyer:
The following points will be carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. If required, refilling with refrigerant compliant with legal regulations
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Technical data subject to change and errors excepted!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
18,513 km
Climate test chamber with humidity
Weiss -72°C bis +180°CWK3-340/70
Call
Condition: excellent (used), Weiss
Type: WK3-340/70
Weiss Climate Test Chamber, Air-Cooled
Control Panel: "Touch Panel"
All control and operating commands can be initiated on the "Touch Panel" control panel by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and to ensure adequate ventilation of the machine, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the test chamber.
Feedthroughs installed as standard:
Csdpfxeziiwus Ailjrd
R1: 125 mm diameter
L1: 85 mm diameter
Volume: 335 liters
Test chamber dimensions:
Height: 750 mm, Width: 580 mm, Depth: 765 mm
External dimensions: Height: 1775 mm, Width: 870 mm, Depth: 1600 mm
Data for temperature tests:
Minimum temperature: -72°C
Maximum temperature: +180°C
Temperature deviation, over time: ± 0.1 to ± 0.5 K
Temperature homogeneity, spatially: ± 0.5 to ± 1.5 K
Temperature change rate, cooling: 3 K/min
Temperature change rate, heating: 3 K/min
Data for climate tests:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatially: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Data for operation:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 16 A, Rated power: 4.9 kW
Fuse: 16 A slow-blow (to be provided by the customer)
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by telephone.
Listing
Borken
18,513 km
Climatic test chamber temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Crodpfx Ajziiwhsiled
Type: VCS 7018-5
Climate testing chamber with humidity, water-cooled
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Specifications for temperature tests:
Temperature range: -70°C to +180°C
Temporal accuracy: ± 0.1 to ± 0.5 K
Spatial accuracy: ± 0.5 to ± 2.0 K
Temperature gradient: 1 to 4 K
Temperature change rate according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Specifications for climate tests:
Temperature range: +10 to +95°C
Humidity range: 10 to 98 % RH
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation: ± 1 to ± 3 % RH
Dew point range: -3 to +94 °C
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 10 kW
Rated current: 21 A
Fuse rating: 32 A slow-blow, on-site
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
18,513 km
Climate test chamber -45°C to +90°C approx. 6 m³
Weiss TechnikWK 6'/45-90 Begehbare
Call
Year of construction: 2014, condition: excellent (used), Weiss Technik WK 6'/45-90 Walk-in Climate Test Chamber
Manufacturer: Weiss Umwelttechnik GmbH
Type: WK 6'/45-90
Year of Manufacture: 2014
Machine Type: Walk-in Temperature and Climate Test Chamber
Refrigeration System: Water-cooled
Test Chamber Volume: approx. 6 m³
Weight: approx. 3,560 kg
For sale is a used walk-in climate test chamber from Weiss Umwelttechnik GmbH.
The system is suitable for temperature and climate testing, environmental simulation, material testing, quality assurance,
as well as development and long-term testing of large test specimens.
Technical Data
Temperature Range: -45 °C to +90 °C
Temperature Change (Heating): approx. 1.8 K/min
Temperature Change (Cooling): approx. 1.8 K/min
Temperature Deviation: ±0.3 to ±1.0 K
Climate Range: +20 °C to +90 °C
Humidity Range: 15 to 95 % RH
Dew Point Range: +4 °C to +81 °C
Humidity Deviation: ±5 % RH
Thermal Load (Heating): 3,200 W
Thermal Load (Cooling): 3,200 W
Dimensions
Test Chamber Dimensions: approx. 1,500 × 2,600 × 1,500 mm (W × D × H)
Housing Dimensions: approx. 2,010 × 5,100 × 2,200 mm (W × D × H)
Refrigeration System
Type: Water-cooled
Refrigerant 1: R452A, 17.0 kg
Refrigerant 2: R23, 8.4 kg
Cooling Water Connection: R 1½"
Cooling Water Pressure: 2 to 6 bar
Cooling Water Inlet: +12 °C
Cooling Water Outlet: +18 °C
Max. Cooling Water Consumption: 15 m³/h
Electrical Data
Mains Connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated Power: 70.2 kW
Rated Current: 117 A
Protection Class: IP54
Noise Level: approx. 70 dB(A)
Max. Heat Dissipation: approx. 4.5 kW
Load Capacity
Floor Load Capacity: 30,000 N/m² (approx. 3,000 kg/m²)
Permissible Wheel Load: 1,000 N per wheel (4 cm² contact area)
Crodpfx Ajzibd Toilod
Equipment
SIMPAC control system
Touch panel operation
Walk-in stainless steel test chamber
Temperature and humidity control
Water-cooled cooling system
4 × 50 W test chamber lighting
Emergency opening from the inside
Test chamber door with safety lock
Cable glands
Documentation / Operating manual
Electrical diagrams available
Application Areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Automotive
Battery testing
Electronics testing
Quality assurance
Research and development
Condition
Used
Optical condition as shown in the pictures.
Scope of Delivery
Weiss Technik WK 6'/45-90 Climate Test Chamber
Documentation / Operating manual
Electrical diagrams
Accessories as shown in the pictures
Scope of delivery as pictured.
Subject to changes, errors and prior sale.
Listing
Borken
18,513 km
Climate test chamber with humidity, 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
Crodpfezh Huhex Ailod
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Climate test chamber temp. -70 to 180°C
Weiss explosionsgeschütztWK-600/70 (I)-(II) 2 G EEx
Call
Condition: excellent (used), Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss Climate Chamber, Water-Cooled
(Test chamber, explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST CHAMBER
Technical Data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Test chamber volume: approx. 600 liters
Cold/Heat operation: -70 to 180°C
Climate operation: 10 – 95°C
Humidity: 10...98 % RH
Temperature change per unit of time:
Cooling: approx. 2.5 K/min
Heating: approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Rated current: 25 A
Fuse (on customer's side): 32 A, slow-blow
Codpjzh D Ryefx Ailord
Permissible weight of test specimens:
Total load of the shelf supports: 80 kg
Test chamber floor: 80 kg, insert shelf: 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(Evaporator of the air conditioning system has been replaced)
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
18,513 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climate test chamber
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Time-related temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4
Rate of change:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration values: +23°C and +80°C
Performance for climate tests:
Temperature range: +10 to +95°C
Time-related temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-related humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580mm, Depth 765mm, Height 750mm
External dimensions: Width 870mm, Depth 1595mm, Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R-404A / R-23
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
Csdpfx Aezg Tx Rjilsrd
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions by telephone.
We make it easier for you to find: "climate test chamber, climatic chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month





































































































































































































































































