Climatic test chamber with humidity, 600 litersCTS
C-40/600 -40 bis +180°C
Climatic test chamber with humidity, 600 liters
CTS
C-40/600 -40 bis +180°C
Condition
Used
Location
Borken 

Machine data
- Machine type:
- Climatic test chamber with humidity, 600 liters
- Manufacturer:
- CTS
- Model:
- C-40/600 -40 bis +180°C
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A22257317
- Reference number:
- 24786
- Update:
- 03.07.2026
Description
CTS Climate Test Chamber Type: C -40/600, Air-Cooled
(converted to R-452a refrigerant)
Test chamber volume: 600 liters
Temperature tests:
- Temperature range: -40°C to +180°C
- Temperature deviation: ±0.1 K / ±0.3 K over time (at stabilized condition)
- Average temperature rate of change (without test load and radiant heat):
- Heating: 2.5 K/min
- Cooling: 3.0 K/min
- Maximum radiant heat input: 2500 W at +20°C
Climatic tests:
- Climate range / Technical data:
Iiodpfx Aeziizgebnjf
- Temperature range: +10°C to +95°C
- Humidity range: 10% r.h. to 98% r.h.
- Dew point range I: +7°C to +94°C
- Dew point range II: –10°C to +7°C
- Consistency values (over time):
- Humidity consistency I: ±0.5% r.h. to ±1.5% r.h.
- Humidity consistency II: ±1% r.h. to ±3% r.h.
- Temperature consistency: ±0.1 K to ±0.3 K
Chamber internal dimensions (approx.): Height: 850 mm, Width: 850 mm, Depth: 830 mm
External dimensions (approx.): Height: 1900 mm, Width: 1115 mm, Depth: 1850 mm
Refrigerant: R-452A
Power connection: 400V 3/N 50Hz
Connected load: 8.2 kW, Rated current: 11.9 A
Weight: 550 kg
Important information for your purchase!
The following checks and procedures are performed on all our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in the technical data and specifications!)
If you have further questions, we will be happy to answer them by phone.
The listing was translated automatically. Translation errors are possible.
(converted to R-452a refrigerant)
Test chamber volume: 600 liters
Temperature tests:
- Temperature range: -40°C to +180°C
- Temperature deviation: ±0.1 K / ±0.3 K over time (at stabilized condition)
- Average temperature rate of change (without test load and radiant heat):
- Heating: 2.5 K/min
- Cooling: 3.0 K/min
- Maximum radiant heat input: 2500 W at +20°C
Climatic tests:
- Climate range / Technical data:
Iiodpfx Aeziizgebnjf
- Temperature range: +10°C to +95°C
- Humidity range: 10% r.h. to 98% r.h.
- Dew point range I: +7°C to +94°C
- Dew point range II: –10°C to +7°C
- Consistency values (over time):
- Humidity consistency I: ±0.5% r.h. to ±1.5% r.h.
- Humidity consistency II: ±1% r.h. to ±3% r.h.
- Temperature consistency: ±0.1 K to ±0.3 K
Chamber internal dimensions (approx.): Height: 850 mm, Width: 850 mm, Depth: 830 mm
External dimensions (approx.): Height: 1900 mm, Width: 1115 mm, Depth: 1850 mm
Refrigerant: R-452A
Power connection: 400V 3/N 50Hz
Connected load: 8.2 kW, Rated current: 11.9 A
Weight: 550 kg
Important information for your purchase!
The following checks and procedures are performed on all our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in the technical data and specifications!)
If you have further questions, we will be happy to answer them by phone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Borken
18,513 km
Climatic test chamber -42 to +190°C
MemmertCTC 256 256 Liter
MemmertCTC 256 256 Liter
Listing
Borken
18,513 km
Climatic chamber temperature and humidity
EspecPL-3KPH -40°C bis 180°C
EspecPL-3KPH -40°C bis 180°C
Listing
Borken
18,513 km
Climate chamber with humidity, 190 liters
VötschVC³ 4018 -42/+180°C
VötschVC³ 4018 -42/+180°C
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVC 4034 -40°C..+180°C
VötschVC 4034 -40°C..+180°C
Listing
Dietfurt an der Altmühl
18,448 km
Temperature chamber
VötschVT 7004
VötschVT 7004
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVCS 4100
VötschVCS 4100
Listing
Borken
18,513 km
Climatic test chamber shaker chamber 2160 liters
WeissWK3-2200/40/5/V -40°C bis +180°C
WeissWK3-2200/40/5/V -40°C bis +180°C
Listing
Borken
18,513 km
Climate chamber
CTSCW-40/16
CTSCW-40/16
Listing
Borken
18,513 km
Electrodynamic vibration test system
ETS SolutionsShaker MPA409/M437A
ETS SolutionsShaker MPA409/M437A
Listing
Borken
18,513 km
Corrosion testing device salt spray chamber
Gebr. LiebischS 1000 A-TR / 42016211
Gebr. LiebischS 1000 A-TR / 42016211
Your listing has been deleted successfully
An error has occurred