Vötsch Climate Test Chamber VC 7018 Temperature Range -70°C to +180°C with Humidity Control, 190 LitVötsch
Vötsch Klimaprüfschrank
Vötsch Climate Test Chamber VC 7018 Temperature Range -70°C to +180°C with Humidity Control, 190 Lit
Vötsch
Vötsch Klimaprüfschrank
Condition
Used
Location
Borken 

Basic data
- Machine type:
- Vötsch Climate Test Chamber VC 7018 Temperature Range -70°C to +180°C with Humidity Control, 190 Lit
- Manufacturer:
- Vötsch
- Model:
- Vötsch Klimaprüfschrank
- Condition:
- used
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A22242822
- Reference number:
- 24613
- Update:
- 15.10.2026
Description
Vötsch
Type: VC 7018
Vötsch Climate Testing Chamber VC 7018, Water-Cooled
Control Panel: “Touch Panel”
All control and operating commands can be initiated by simply touching the function symbols on the “Touch Panel” control panel.
Gusdpfxozh Huhe Af Tsh
Adjustable Feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine, the testing chamber is equipped with adjustable feet.
Feedthroughs
The testing chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the testing chamber.
Feedthroughs installed as standard:
R1: 125 mm
L1: 50 mm
Testing chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Performance data for temperature tests:
Temperature range: -70°C to +180°C
Temporal: ±0.1 to ±0.5 K
Spatial: ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min.
Cooling: 2.3 K/min.
Performance data for climate tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% RH
Temporal temperature deviation in the center of the usable space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Temporal humidity deviation in the center of the usable space: ±1 to ±3 % RH
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10 50Hz
Rated power: 5.9 kW
Rated current: 12.0 A
Connection cable: 3.5 m
Fuse: 16 A, slow-blow, provided on site
Refrigerant: R-404A and R-23
Testing chamber volume: approx. 190 liters
Weight: approx. 460 kg net
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Type: VC 7018
Vötsch Climate Testing Chamber VC 7018, Water-Cooled
Control Panel: “Touch Panel”
All control and operating commands can be initiated by simply touching the function symbols on the “Touch Panel” control panel.
Gusdpfxozh Huhe Af Tsh
Adjustable Feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine, the testing chamber is equipped with adjustable feet.
Feedthroughs
The testing chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and testing equipment to be routed into the testing chamber.
Feedthroughs installed as standard:
R1: 125 mm
L1: 50 mm
Testing chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Performance data for temperature tests:
Temperature range: -70°C to +180°C
Temporal: ±0.1 to ±0.5 K
Spatial: ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min.
Cooling: 2.3 K/min.
Performance data for climate tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% RH
Temporal temperature deviation in the center of the usable space: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Temporal humidity deviation in the center of the usable space: ±1 to ±3 % RH
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10 50Hz
Rated power: 5.9 kW
Rated current: 12.0 A
Connection cable: 3.5 m
Fuse: 16 A, slow-blow, provided on site
Refrigerant: R-404A and R-23
Testing chamber volume: approx. 190 liters
Weight: approx. 460 kg net
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Success:
Your message has been sent.
Listing
Borken
18,513 km
Vötsch climate test chamber VCS 7034-5, -70°C to +180°C, 335 liters, with humidity control
VötschVötsch Klimaprüfschrank
VötschVötsch Klimaprüfschrank
Success:
Your message has been sent.
Listing
Borken
18,513 km
Vötsch VT 7012 S2 Temperature Shock Test Chamber -70 to 220°C Thermal Shock Test Chamber
VötschVT 7012 S2
VötschVT 7012 S2
Success:
Your message has been sent.
Listing
Borken
18,513 km
Vötsch climate test chamber VCS 7034-5, -70°C to +180°C, 335 liters, with humidity control
Heraeus VötschVötsch Klimaprüfschrank
Heraeus VötschVötsch Klimaprüfschrank
Success:
Your message has been sent.
Listing
Borken
18,513 km
Vötsch climate test chamber VCS 7034-5, -70°C to +180°C, 335 liters, with humidity control
Heraeus VötschVötsch Klimaprüfschrank
Heraeus VötschVötsch Klimaprüfschrank
Success:
Your message has been sent.
Listing
Borken
18,513 km
Vötsch climate test chamber VCS 7033 -70°C to +180°C with humidity control
Heraeus VötschVötsch Klimaprüfschrank
Heraeus VötschVötsch Klimaprüfschrank
Your listing has been deleted successfully
An error has occurred