Climate test chamber +20 to +130°C, 240 lWeiss Technik
EmissionEvent VOC/240
Climate test chamber +20 to +130°C, 240 l
Weiss Technik
EmissionEvent VOC/240
Condition
Used
Location
Borken 

Machine data
- Machine type:
- Climate test chamber +20 to +130°C, 240 l
- Manufacturer:
- Weiss Technik
- Model:
- EmissionEvent VOC/240
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A22270652
- Reference number:
- 25033
- Update:
- 06.07.2026
Description
Weiss
Type: EmissionEvent VOC/240
Weiss Technik EmissionEvent VOC/240
Industrial Emission Test Chamber / VOC Test Chamber / Climatic Test Cabinet
Water-cooled
A professional emission test chamber is offered for sale
Weiss Technik EmissionEvent VOC/240 (Year of manufacture: 2018)
from an industrial laboratory and testing operation.
The device is designed for conducting standardized emission tests under precisely controlled temperature,
climatic, and process conditions, and is built for continuous use in laboratories, industrial settings, and quality assurance.
What does VOC mean / What does the device do?
VOC = Volatile Organic Compounds
The device measures and tests the outgassing (emissions) of materials under defined conditions.
It analyses which substances are released into the air by a given material. Typical applications include:
- Emission testing of plastics, components, materials
- Automotive interior material testing (odor / pollutants)
- Building products & furniture emission measurement
- Packaging, textiles, adhesives, paints
- Quality control and standard testing (e.g. ISO / VDA / DIN)
The test system generates precisely defined temperature, humidity, and air conditions.
Emissions are extracted from the test space using a carrier gas (e.g. nitrogen or air)
and can subsequently be analyzed using appropriate measuring equipment.
Device features / Equipment:
- Stainless steel emission test chamber (hermetically sealed)
- Temperature and climate control
- Carrier gas system for emission measurement
- Automatic process control with touch panel
- Programmable operation / continuous operation possible
- Sampling ports for VOC analysis
- Industrial-grade construction (suitable for laboratory and continuous operation)
Technical data for temperature testing:
- Temperature range: +20 to +130 °C
- Temporal temperature deviation at chamber center: ±0.1 to ±0.3 K
- Spatial temperature uniformity: ±0.1 to ±0.5 K
- Temperature change rate (according to IEC 60068-3-5):
Heating: 0.4 K/min
Cooling: 0.3 K/min
- Temperature change rate (average, with enhanced heating and cooling capacity):
Heating up to +65 °C: 1.5 K/min
Cooling from +65 °C to +20 °C: 1.3 K/min
Technical data for climate testing:
- Temperature range: +20 to +130 °C
- Dew point range: +5 to +60 °C
- Relative humidity range: 5 to 95% RH
- Temporal temperature deviation: 0.1 to 0.3 K
- Temporal humidity deviation: -3 to 3% RH
Dimensions EmissionEvent VOC/240
External dimensions (unit):
Width: approx. 1350 mm, Depth: approx. 2500 mm, Height: approx. 1985 (2190) mm
Internal dimensions (test space):
Emission test chamber: 200 l
Gross test chamber volume: 240 l
Nlsdpfx Asziyz Rohkof
Net test chamber volume: 208 l
Max. test sample load: 80 kg
Internal dimensions VOC/240:
Width: approx. 600 mm, Depth: approx. 560 mm, Height: approx. 600 mm
Electrical:
Voltage: 3/N/PE AC 400 V ±10% / 50 Hz
Nominal power: 12.1 kW
Nominal current: 30 A
Protection class: IP54
Refrigerant:
R134a – 2.5 kg
Weight: approx. 1080 kg
Important information for you as the buyer:
The following procedures are carried out on the chambers we offer prior to sale:
1. Functional inspection and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Following successful inspection, a documented trial run is carried out
Condition: used
Scope of supply: (see picture)
(Technical data and specifications subject to change and errors!)
For further questions, feel free
The listing was translated automatically. Translation errors are possible.
Type: EmissionEvent VOC/240
Weiss Technik EmissionEvent VOC/240
Industrial Emission Test Chamber / VOC Test Chamber / Climatic Test Cabinet
Water-cooled
A professional emission test chamber is offered for sale
Weiss Technik EmissionEvent VOC/240 (Year of manufacture: 2018)
from an industrial laboratory and testing operation.
The device is designed for conducting standardized emission tests under precisely controlled temperature,
climatic, and process conditions, and is built for continuous use in laboratories, industrial settings, and quality assurance.
What does VOC mean / What does the device do?
VOC = Volatile Organic Compounds
The device measures and tests the outgassing (emissions) of materials under defined conditions.
It analyses which substances are released into the air by a given material. Typical applications include:
- Emission testing of plastics, components, materials
- Automotive interior material testing (odor / pollutants)
- Building products & furniture emission measurement
- Packaging, textiles, adhesives, paints
- Quality control and standard testing (e.g. ISO / VDA / DIN)
The test system generates precisely defined temperature, humidity, and air conditions.
Emissions are extracted from the test space using a carrier gas (e.g. nitrogen or air)
and can subsequently be analyzed using appropriate measuring equipment.
Device features / Equipment:
- Stainless steel emission test chamber (hermetically sealed)
- Temperature and climate control
- Carrier gas system for emission measurement
- Automatic process control with touch panel
- Programmable operation / continuous operation possible
- Sampling ports for VOC analysis
- Industrial-grade construction (suitable for laboratory and continuous operation)
Technical data for temperature testing:
- Temperature range: +20 to +130 °C
- Temporal temperature deviation at chamber center: ±0.1 to ±0.3 K
- Spatial temperature uniformity: ±0.1 to ±0.5 K
- Temperature change rate (according to IEC 60068-3-5):
Heating: 0.4 K/min
Cooling: 0.3 K/min
- Temperature change rate (average, with enhanced heating and cooling capacity):
Heating up to +65 °C: 1.5 K/min
Cooling from +65 °C to +20 °C: 1.3 K/min
Technical data for climate testing:
- Temperature range: +20 to +130 °C
- Dew point range: +5 to +60 °C
- Relative humidity range: 5 to 95% RH
- Temporal temperature deviation: 0.1 to 0.3 K
- Temporal humidity deviation: -3 to 3% RH
Dimensions EmissionEvent VOC/240
External dimensions (unit):
Width: approx. 1350 mm, Depth: approx. 2500 mm, Height: approx. 1985 (2190) mm
Internal dimensions (test space):
Emission test chamber: 200 l
Gross test chamber volume: 240 l
Nlsdpfx Asziyz Rohkof
Net test chamber volume: 208 l
Max. test sample load: 80 kg
Internal dimensions VOC/240:
Width: approx. 600 mm, Depth: approx. 560 mm, Height: approx. 600 mm
Electrical:
Voltage: 3/N/PE AC 400 V ±10% / 50 Hz
Nominal power: 12.1 kW
Nominal current: 30 A
Protection class: IP54
Refrigerant:
R134a – 2.5 kg
Weight: approx. 1080 kg
Important information for you as the buyer:
The following procedures are carried out on the chambers we offer prior to sale:
1. Functional inspection and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. Following successful inspection, a documented trial run is carried out
Condition: used
Scope of supply: (see picture)
(Technical data and specifications subject to change and errors!)
For further questions, feel free
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Győr
18,081 km
HPLC system w/ software - please read!
Agilent1100
Agilent1100
Listing
Duxford
18,728 km
Agilent Cary 100 UV-Vis spectrophotometer
AgilentCary 100
AgilentCary 100
Listing
Borken
18,513 km
Rotational and oscillatory rheometer
Anton Paar Physica MCR 301Physica MCR 301 mit Rheoplus Software
Anton Paar Physica MCR 301Physica MCR 301 mit Rheoplus Software
Listing
Duxford
18,728 km
Grant GD120 Stirred Water Bath
Grant GD120 Stirred Water BathGrant GD120 Stirred Water Bath
Grant GD120 Stirred Water BathGrant GD120 Stirred Water Bath
Listing
Germany
18,384 km
Residual Moisture Analyzer
BrabenderAquatrac Station 822000
BrabenderAquatrac Station 822000
Listing
Borken
18,513 km
Laboratory freezer, refurbished
InfricoLTF 90S
InfricoLTF 90S
Listing
Duxford
18,728 km
Velp Scientific HSC Heating Magnetic Stirrer
Velp ScientificHSC
Velp ScientificHSC
Listing
Duxford
18,728 km
Foster EcoPro G2 EP700H Pro Cabinet Freezer
FosterEcoPro G2
FosterEcoPro G2
Your listing has been deleted successfully
An error has occurred