Used Vötsch Vtr 7033/S for sale (67,869)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
18,513 km
Temperature cabinet 110 liters
VötschVT 7011 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a Heraeus Vötsch temperature control chamber.
Heraeus Vötsch temperature control chamber, water-cooled
Psdpezdtd Isfx Aahjpu
Test chamber volume: 110 liters
Test chamber dimensions: Width 560 mm, Depth 350 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1030 mm, Height 1640 mm
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temperature gradient: 1 to 3 K
Temperature change rate (cooling): 3.2 K/min
Temperature change rate (heating): 3.5 K/min
Refrigerant: R-404 A / R 23
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power: 1.8 kW
Rated current: 12 A
Type: VT 7011
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
18,513 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Here we offer you a Heraeus Vötsch temperature testing chamber.
Heraeus Vötsch temperature testing chamber, water-cooled
Temperature range: -70°C to +180°C
Temperature deviation (time-related): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 7.5 K/min
Temperature change rate (heating): 7.5 K/min
Thermal compensation +20°C: 3000 W
Thermal compensation -20°C: 3000 W
Podpfxjzdtdhe Aahjpu
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Observation window:
Width 300 mm x Height 540 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400 V ±10 %, 50 Hz
Rated power: 10.5 kW, Rated current: 22 A
Fuse, on customer side: 32 A, slow-blow
Sound pressure level at 1 m distance (free-field measurement): < 69 dB(A)
Side access: 50 cm / 125 cm
Chamber is water-cooled
Refrigerant: R 404A and R 23
Weight: approx. 460 kg
Type: VTS 7018-5
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. Refilling with refrigerants that comply with legal regulations
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch Temperature Shock Testing Chamber
Type: VT 7012 S2
Manufacturer: Vötsch Industrietechnik GmbH
Design: Water-cooled
For sale is a two-chamber temperature shock testing chamber from Vötsch, designed for rapid temperature change tests. Suitable for industrial, automotive, aerospace, as well as research and development applications.
Temperature Ranges:
Hot Chamber: +50 °C to +220 °C
Cold Chamber: -80 °C to +70 °C
Temperature Data:
Temporal temperature deviation: ±1 K
Spatial temperature deviation: ±2 K
Heating rate, hot chamber: approx. 11 K/min
Heating rate, cold chamber: approx. 2 K/min
Cooling rate: approx. 3 K/min
Test Chamber:
Volume: approx. 125 liters
Internal dimensions: approx. 470 x 650 x 410 mm
Cable entry: Ø 67 mm
Electrical Data:
Podpfx Aasy Iyuwshepu
Connection: 3/N/PE AC 400 V ±10% / 50 Hz
Rated power: approx. 10 kW
Rated current: approx. 25 A
Refrigerant:
R404A: 2.9 kg
R23: 1.27 kg
Pressure Data:
ND max.: 22.5 bar
HD max.: 25 bar
Dimensions:
approx. 930 x 2115 x 1970 mm
Weight:
approx. 1000 kg
Equipment:
Two-chamber shock testing system
Digital control
Program operation
Observation window
Cable entry
Condition:
Used
Optical condition as shown in the pictures
Normal storage and usage marks present
Scope of delivery:
Vötsch VT 7012 S2 temperature shock testing chamber
Accessories as shown in the pictures
Important Note:
All information has been provided to the best of our knowledge based on the pictures, nameplates, and manufacturer information.
Shipping is possible.
Subject to changes, errors and prior sale.
We are happy to answer any further questions by phone.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Győr
18,083 km
Temperature test chamber -72°C to +180°C
VötschVTS 7060-5 600 Liter
Call
Year of construction: 2016, operating hours: 14,242 h, condition: excellent (used), Vötsch temperature test chamber, water-cooled
Here we offer you a Vötsch temperature test chamber.
Vötsch 7060-5 water-cooled chanber
Test chamber dimensions: Height: 950 mm, width: 800 mm, depth: 800 mm
External dimensions: Height 1995 mm, width: 1090 mm, depth: 1960 mm
Test chamber capacity: approx. 600 liters
Ppedpfx Aet Txqrsahju
Year of construction: 2016
Operational hours: 14 242
Entry ports:
R1: NW 125 mm
L1: NW 50 mm
Data for temperature tests:
Temperature range: -72°C to +180°C
Temperature deviation in time in the center of the usable space ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature change rate
Heating 6.0 K/min
Cooling 6.0 K/min
Heat compensation at 20°C max. 5000 W
Heat compensation at -20°C max. 5000 W
Electrical connection:
Rated voltage: 3/NPE AC 400V ±10% 50Hz
Rated power: 13,0 kW Rated current: 23.0 A
Refrigerant: R-404A and R-23
Weight (approx.): 650 kg
The following information is for your safety as a buyer!
1. The chamber works perfectly.
2. No components have to be replaced.
3. Refrigerant is filled with legally compliant.
Condition: used (excellent)
(Changes and errors in the technical data, specifications are reserved!)
Listing
Borken
18,513 km
Large-capacity oven
VötschOfen NTUD 125/130/125 50 bis 150°C
Call
Condition: used, Vötsch
Type: NTUD 125/130/125
Pass-through oven
Last maintenance: 3.12.25
Temperature control in 3 zones:
Control of the internal temperature via an electronic temperature control system, divided into 3 separate temperature zones and controlled by semiconductor switching devices. This ensures good temperature uniformity whether operating in fresh or recirculated air mode.
Temperature program control:
The CTC control system is operated via a dialog PC with TSI software for the heating control of each temperature zone, as well as the activation of the recirculation fans and damper control.
Ppjdpoy H Akrsfx Aahou
Horizontal airflow with reversal:
By switching the electronically or pneumatically actuated dampers, the airflow direction can be set from left to right or right to left. The airflow direction for each of the 3 zones can be independently adjusted.
Vertical airflow:
By shifting a cover plate in the oven ceiling.
Useful floor area:
The floor area can be driven on using customer-provided loading trolleys.
Recirculation fans:
Each zone is equipped with a radial fan.
Usable space dimensions: 1300 mm height / 1250 mm width / 1250 mm depth
External dimensions: 2490 mm height / 1770 mm width / 1810 mm depth
Volume: 2000 liters
Connection rating: 400V(N)PE AC 50/60 Hz 22 kVA
Rated current: 32 A
Power: 18 kW
Nominal temperature: 50 to 150°C
Weight: 1000 kg
Condition: used
Scope of delivery: (See photo)
(Specifications and data subject to change and errors excepted!)
We are happy to answer any further questions by phone.
Listing
Borken
18,517 km
Vötsch VTU 60/60 drying oven 250°C
VötschVötsch VTU 60/60
Call
Year of construction: 2010, condition: good (used), Here we offer a Vötsch VTU 60/60 drying oven.
Vötsch VTU 60/60 drying oven
Nominal temperature: 250°C
Interior dimensions: width 600 mm height 600 mm depth 600 mm
Outer dimensions: width 1000 mm height 1675 mm depth 1300 mm
Supply voltage: 400 V 3 (N) PE AC, 50/60 Hz
Pedon Hqg Djpfx Aahepu
Type: VTU 60/60
Listing
Borken
18,517 km
Vötsch climatic test chamber Fitotron HGC1014
Vötsch Klimaprüfschrank 5°C bis +45°Fitotron HGC 1014 V Schrank 3 mit Bel.
Call
Condition: excellent (used), functionality: fully functional, Year of construction: 2012, Fitotron® Modular Plant Growth Chambers, Type HGC 1014 V, including HQI-T and Krypton Lighting Module
Temperature range +5°C - +45°C for temperature testing
Test chamber volume approx. 1300 l
Simpac Control System
Network Connection
USB Connection
The Fitotron® HGC series plant growth chambers are based on a modular design. Individual modules can be added or replaced as needed. This allows them to be adapted to different applications. They are suitable for plants with high light requirements, such as wheat, corn, cotton, rice, and C4 plants.
Lighting HQI-BT-400 W/D and 100 W,
Temperature range +5°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% RH approx. 0.8 kW
Characteristics for climatic tests with irradiation
Temperature range +10°C to +45°C with light on +10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Humidification and dehumidification system, stainless steel test chamber
Internal dimensions: Height 1400 mm, Depth 750 mm, Width 1270 mm
External dimensions: Height 1985 mm, Depth 980 mm, Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single door with observation window
Interface for computer connection
Connection 3/N/PE 400V ±10% 50Hz
CE marking, mobile, very good condition
Pipe penetration ∅ 50 mm
Air cooling
Podpovz U Erofx Aahopu
Refrigerant R404A
Weight approx. 480 kg + 130 kg lighting module
Listing
Borken
18,513 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch Type: VTS 7018-5 Heraeus Vötsch Temperature Test Chamber, Water-Cooled Temperature range: -70°C to +180°C Temporal temperature deviation: ± 0.1 to ± 0.5 K Spatial temperature deviation: ± 0.5 to ± 2.0 K Temperature change rate (cooling): 6.5 K/min Temperature change rate (heating): 7.5 K/min Heat compensation: 4,500 W Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm External dimensions: Width 870 mm x Depth 1,280 mm x Height 1,575 mm Viewing window: Width 300 mm x Height 540 mm Test chamber volume: 190 liters Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz Rated power: 10 kW Rated current: 21 A Supply-side fuse: 32 A slow-blow Sound level at 1 m distance (free-field measurement): < 63 dB(A) Lateral port: 50 cm / 125 cm Chamber is water-cooled Refrigerants: R452A and R23 Weight: approx. 460 kg Important safety information for buyers: The following procedures are carried out on all chambers offered by us: 1. Functional check and replacement of necessary components 2. If required, refilling with legally compliant refrigerant 3. Leak test with certificate 4. After successful inspection, all chambers are subjected to a documented trial run. Condition: used Scope of delivery: (see photos) (Technical data and specifications subject to change and errors!) If you have further questions, we are happy to provide information by phone.
Ppodpfoyu Rhgjx Aahju
Listing
Borken
18,517 km
Control system
Vötsch Pflanzenwuchsschrank -10 bis +45Fitotron HGC 1014 V Schrank 1
Call
Condition: excellent (used), Year of construction: 2012, functionality: fully functional, Fitotron® Modular Plant Growth Chambers, Type HGC 1014 V, including HQI-T and Krypton Lighting Module
Temperature range -10°C - +45°C for temperature testing
Test chamber volume approx. 1300 l
Simpac Control System
Network Connection
USB Connection
The Fitotron® HGC series plant growth chambers are based on a modular design. Individual modules can be added or replaced as needed. This allows them to be adapted to different applications. They are suitable for plants with high light requirements, such as wheat, corn, cotton, rice, and C4 plants.
Lighting HQI-BT-400 W/D and 100 W,
Temperature range -10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% RH approx. 0.8 kW
Characteristics for climatic tests with irradiation
Temperature range +10°C to +45°C with light on +10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Humidification and dehumidification system, stainless steel test chamber
Internal dimensions: Height 1400 mm, Depth 750 mm, Width 1270 mm
External dimensions: Height 1985 mm, Depth 980 mm, Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single door with observation window
Interface for computer connection
Connection 3/N/PE 400V ±10% 50Hz
CE marking, mobile, very good condition
Pipe penetration ∅ 50 mm
Pedjv Ivnzspfx Aahopu
Air cooling
Refrigerant R404A
Weight approx. 480 kg + 130 kg lighting module
Listing
Borken
18,517 km
Control system
Vötsch Pflanzenwuchsschrank -10 bis +45Fitotron HGC 1014 V Schrank 4
Call
Condition: excellent (used), Year of construction: 2012, functionality: fully functional, Fitotron® Modular Plant Growth Chambers, Type HGC 1014 V, including HQI-T and Krypton Lighting Module
Temperature range -10°C - +45°C for temperature testing
Test chamber volume approx. 1300 l
Simpac Control System
Network Connection
USB Connection
The Fitotron® HGC series plant growth chambers are based on a modular design. Individual modules can be added or replaced as needed. This allows them to be adapted to different applications. They are suitable for plants with high light requirements, such as wheat, corn, cotton, rice, and C4 plants.
Lighting HQI-BT-400 W/D and 100 W,
Temperature range -10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% RH approx. 0.8 kW
Characteristics for climatic tests with irradiation
Temperature range +10°C to +45°C with light on +10°C to +45°C
Temperature deviation over time ± 0.5 K
Pedpfjv Ivn Usx Aahjpu
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Humidification and dehumidification system, stainless steel test chamber
Internal dimensions: Height 1400 mm, Depth 750 mm, Width 1270 mm
External dimensions: Height 1985 mm, Depth 980 mm, Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single door with observation window
Interface for computer connection
Connection 3/N/PE 400V ±10% 50Hz
CE marking, mobile, very good condition
Pipe penetration ∅ 50 mm
Air cooling
Refrigerant R404A
Weight approx. 480 kg + 130 kg lighting module
Listing
Borken
18,517 km
Plant growth cabinet Fitotron HGC 1014
Vötsch Pflanzenwuchsschrank -10 bis +45Fitotron HGC 1014 V Schrank 2
Call
Condition: excellent (used), functionality: fully functional, Year of construction: 2012, Fitotron® Modular Plant Growth Chambers, Type HGC 1014 V, including HQI-T and Krypton Lighting Module
Temperature range -10°C - +45°C for temperature testing
Test chamber volume approx. 1300 l
Simpac Control System
Network Connection
USB Connection
The Fitotron® HGC series plant growth chambers are based on a modular design. Individual modules can be added or replaced as needed. This allows them to be adapted to different applications. They are suitable for plants with high light requirements, such as wheat, corn, cotton, rice, and C4 plants.
Lighting HQI-BT-400 W/D and 100 W,
Temperature range -10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% RH approx. 0.8 kW
Characteristics for climatic tests with irradiation
Psdjv Ivn Ispfx Aahopu
Temperature range +10°C to +45°C with light on +10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Humidification and dehumidification system, stainless steel test chamber
Internal dimensions: Height 1400 mm, Depth 750 mm, Width 1270 mm
External dimensions: Height 1985 mm, Depth 980 mm, Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single door with observation window
Interface for computer connection
Connection 3/N/PE 400V ±10% 50Hz
CE marking, mobile, very good condition
Pipe penetration ∅ 50 mm
Air cooling
Refrigerant R404A
Weight approx. 480 kg + 130 kg lighting module
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
Psdpfx Aoygvn Neahepu
With temperature change rate of 5 K/min
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Refrigerant: R404A / R-23
Weight approx. 570 kg
For your security as a buyer, please note the following:
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.
Listing
Borken
18,513 km
Temperature test chamber 990 liters
VötschVT³ 4100 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4100
Water-Cooled Temperature Test Chamber
S!MCON/32.NET (with Touch Panel)
Control System Features:
- Color touchscreen with intuitive menu navigation (typically 5.7" or larger)
- Programming of temperature/humidity profiles with ramps and dwell times
- Data acquisition & logging (e.g., temperature profile, alarms)
- USB port for data export (CSV, optionally S!MPATI compatible)
- Network interface (Ethernet) for remote monitoring and control
- User management with password protection
- Interfaces: Volt-free contacts, optionally Modbus or Profibus
VT³ 4100 – Technical Specifications (Temperature Test Chamber)
- Test volume: 990 liters
- Temperature range: -40 °C to +180 °C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1.5 K
Ppjdpfxoygvm Ee Aahju
- Temperature gradient: 1 to 3 K
- Temperature change rate (per IEC 60068-3-5):
• Heating: 4.0 K/min
• Cooling: 3.0 K/min
- Maximum heat compensation capacity: 4500 W
- Calibration values: +23 °C and +80 °C
- Internal dimensions (W×D×H): 1100 × 950 × 950 mm
- External dimensions (W×D×H): 1390 × 1955 × 1995 mm
Feed-Throughs:
The chamber is equipped with feed-throughs on both the right and left sides, allowing insertion of measuring cables and test devices into the test space.
• 1 × L1 nominal width 50 mm
• 1 × R1 nominal width 125 mm
• 3 × R1 nominal width 50 mm
Electrical connection: 3/N/PE AC, 400V ±10%, 50Hz
Power consumption: 11.5 kW
Rated current: 22 A
Noise level: approx. 62 dB(A)
Refrigerant: R452A
Weight: 920 kg
Important information for buyers:
For your security, the following measures are carried out on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data; information may be subject to alteration!)
For any further questions, feel free to contact us by phone.
Listing
Borken
18,513 km
Climate test chamber with humidity
VötschVC³ 0100 0°C bis + 90°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 0100
Vötsch Climate Test Chamber, Air-Cooled
Internal Test Chamber Dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall Device Dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Test Chamber Volume: 990 litres
Temperature Testing:
Minimum Temperature: -0°C
Maximum Temperature: +90°C
Temperature Change Rate, Cooling: 0.2 K/min
Temperature Change Rate, Heating: 0.5 K/min
Temporal Temperature Deviation: ±0.1 to ±0.5 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Heat Compensation at +20 °C: 350 W
Climatic Testing:
Minimum Temperature: +10°C
Maximum Temperature: +90°C
Dew Point Temperature Range: +4°C to +89.5°C
Humidity Range: 10 to 98% r.h.
Temporal Humidity Deviation: ±1 to ±3% r.h.
Temporal Temperature Deviation: ±0.1 to ±0.3 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Refrigerant: R-404A
Weight: approx. 1400 kg
Important information for you as a buyer:
The following measures are carried out on our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and error!)
Pedpeygut Rofx Aahjpu
For further questions, we are happy to assist you by phone.
Listing
Borken
18,513 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Ppsdpfxoygutwe Aahju
Port openings: Ø 125 mm, Ø 50 mm
Temperature test specifications:
Temperature range: -42°C to +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Max. heat compensation at +20°C: 4500 watts
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1% to ± 3% r.h.
Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
For your security as a buyer, please note the following information!
The following points are checked and carried out on all our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. If needed, fresh filling with legally compliant refrigerant
3. Leak check with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Subject to prior sale, changes and errors in technical data and specifications reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Ppjdpfjygur Tox Aaheu
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Borken
18,513 km
Temperature shock test chamber
VötschVT 7030 S2
Call
Condition: good (used), Year of construction: 1998, Vötsch VT 7030 S2 Temperature Shock Test Chamber -80 °C to +220 °C
The Vötsch VT 7030 S2 Environmental Test Chamber is designed for laboratory applications that require testing of materials and components in a known environment. With its versatile capabilities and easy-to-use controls, this programmable unit can be used to simulate a variety of environmental conditions for scientific studies, product testing and process control.
Data for temperature tests in single chamber operation
Hot chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range +50 °C to +220 °C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation in space ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 11 K/min
Cold chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range -80 °C to +70 °C
Temperature deviation in time in the middle of the usable space ± 1 K
Temperature deviation in space 2 K
Ppedewbdv Sopfx Aahju
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 1.5 K/min
Cooling 4K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10 % , 50 Hz
Rated power: 30 kW
Rated power: 50 A
Refrigerant: R-404a /R-23
Chiller: Water-cooled
Weight: approx. 940 kg
Year of construction. 1998
Test room dimensions: Width 770 mm x depth 650 mm x height 610 mm
Housing dimensions: Width 1200 mm x depth 1800 mm x height 2050 mm
TS 05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVCS 7100
Call
Condition: good (used), Vötsch VCS 7100 Climatic Test Chamber -70°C to +180°C
Manufacturer: Vötsch
Ppodpfx Aajuuix Nshju
Type: VCS 7100
Temp. Range: -70°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Rated Power: 11 kW
Refrigerant: R404A
Height: 1980 mm
Width: 1350 mm
Depth: 2060 mm
Chamber:
Height: 900 mm
Width: 970 mm
Depth: 1400 mm
KK-05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Temperature shock test chamber -70-220°C
VötschVT 7012 S2
Call
Year of construction: 2000, operating hours: 104,382 h, condition: excellent (used), Vötsch Shock Test Chamber VT 7012 S2
System for extreme temperature cycling
Temperature shock testing is used to test the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclical stresses and the accelerated aging caused by temperature changes reveal weaknesses in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the car
Cart load capacity 50 kg for VT3 7012 S2
All-around grilles in the car secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
Hot chamber can be used as a temperature storage unit, cold chamber as a temperature exchange unit
Minimal energy consumption
Pjdpfjx Exmtsx Aahspu
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
Cooling unit: Water-cooled
Shock cooling (nitrogen cooling) via customer-supplied nitrogen
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class
Device: IP 42
Operating panel: IP 20
Control cabinet: IP 54
Temperature test parameters for single-chamber operation |
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class ...Temperatur Temperature range
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K
in steady state
Temperature deviation over space: ±2 K
in steady state in the car
Heating rate, hot chamber: 11 K/min
Cooling rate, cold chamber: K/min
Heating rate, cold chamber: 2 K/min
Cooling rate, hot chamber: K/min
Observation window: 355 x 355 mm
Pipe opening: 67 mm
Year of manufacture: 2000
Operating hours: 104,382
Weight: 1000 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items – new and used – can be found in our shop! International shipping costs on request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVCS 4100
Call
Condition: good (used), Vötsch VCS 4100 Climatic Test Chamber -40°C to +180°C
Manufacturer: Vötsch
Type: VCS 4100
Temp. Range: -40°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Rated Power: 11 kW
Refrigerant: R404A
KK-07
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
Pjdpfx Ajuuiygsahepu
International shipping costs upon request!
Listing
Borken
18,513 km
-50°C to +220°C, -80 to +70°C, 60 liters
VötschVT³ 7006 S2 Temperaturschockschrank
Call
Condition: excellent (used), Vötsch
Type: VT³ 7006 S2-M
Water-cooled
Ppsdpfjx Hglyex Aahsu
Technical Specifications:
Maximum specimen weight: 20 kg
Test chamber volume: 60 liters
Test chamber internal dimensions: Width 380 mm, Depth 430 mm, Height 370 mm
External dimensions: Width 875 mm, Depth 1970 mm, Height 1895 mm
Vertical arrangement of hot and cold chambers (chamber change via lift carriage)
Temperature range of hot chamber: +50 °C to +220 °C (calibration value +125 °C)
Temperature range of cold chamber: -80 °C to +70 °C (calibration value -40 °C)
Uniform temperature distribution in the test chamber (±0.5 K to ±2.0 K)
Temporal temperature deviation: ±0.3 K to ±1.0 K
80 mm duct for measurement/supply connections to the specimen
SIMCONTROL software for operation and status display
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power: 8.5 kW
Rated current: 25 A
Refrigerants: R-404A, R-23
Weight: approx. 800 kg
Important information for your safety as a buyer!
The following points are carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if required
3. Leak test with certificate
4. Following successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Specifications and information subject to change or error!)
Should you have any further questions, we are happy to answer them by phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
18,513 km
Climatic chamber
VötschVCS 7034-5
Call
Condition: used, Vötsch
Model: VCS 7034-5
Climatic Test Chamber, Water-Cooled
Test chamber volume: 335 liters
Specifications for temperature testing:
Temperature range: -70 to +180°C
Temporal temperature deviation: K ±0.1 to ±0.5
Spatial temperature deviation: K ±0.5 to ±2.0
Temperature gradient: 1 to 4 K
Rate of change:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration values: +23°C and +80°C
Specifications for climate testing:
Temperature range: +10 to +95°C
Temporal temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Temporal humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400W
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580mm, Depth 765mm, Height 750mm
External dimensions: Width 870mm, Depth 1595mm, Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R404A / R-23
For your safety as a buyer, please take note of the following information!
The following procedures are carried out in advance on all chambers we offer:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Upon successful inspection, the chambers undergo a documented test run
Ppodpfx Aaoxqzbbshju
Condition: used
Scope of delivery: (see picture)
(Technical specifications subject to change and error)
If you have further questions, we would be happy to answer them by phone.
Listing
Borken
18,513 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
Pjdpfxowxc I Uo Aahepu
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.
Listing
Borken
18,513 km
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
Ppodsv N Hc Eopfx Aaheu
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
With humidity 270 liters
VötschKlimaprüfschrank VCS³ 7027-10
Call
Condition: excellent (used), Vötsch
Type: VCS³ 7027-10
Vötsch Climatic Test Chamber, Water-Cooled
With a temperature change rate of 10 K/min
Temperature test data:
Temperature range -72°C to +180°C
Temperature deviation over time in the center of the work space ± 0.3 K to ± 0.5 K
Temperature deviation over space ± 0.5 K to ± 2.0 K
Temperature change rate
Heating: 10 K/min
Cooling: 14.5 K/min
Climatic test data:
Temperature range +10°C to +95°C
(Extended climatic range: 2°C/95% RH, controlled for a maximum of 2 hours)
Temperature deviation over time in the center of the work space ± 0.2 K to ± 0.3 K
Temperature deviation over space ± 0.5 K to ± 1.0 K
Humidity deviation in the center of the usable space: ± 1% to ± 3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH, regulated for a maximum of 2 hours)
External dimensions: Width 780 x Depth 1895 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 615 x Height 750 (mm)
Test chamber volume: approx. 270 liters
Side opening 50 mm
Side opening 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V±10%, 50 Hz
Pjdpfxov R Ty Ts Aahjpu
Rated power: 14 kW
Rated current: 26 A
Fuse, on-site: 63 A slow-blow
Refrigerant R404A/R-23
Weight approx. 835 kg
For your safety, please note the following information as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
We make it easier for you to find: "vötsch vtr 7033/s"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month