Shock test chamber –80 °C to +220 °CVötsch
VT 7012 S2
Shock test chamber –80 °C to +220 °C
Vötsch
VT 7012 S2
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Shock test chamber –80 °C to +220 °C
- Manufacturer:
- Vötsch
- Model:
- VT 7012 S2
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A19499871
- Reference number:
- 24677
- Update:
- 04.07.2025
Description
Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
Nkjdpfx Ahswxc I Ujvsu
For further questions, please feel free to contact us by phone.
The listing was translated automatically. Translation errors are possible.
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
Nkjdpfx Ahswxc I Ujvsu
For further questions, please feel free to contact us by phone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Borken
18,513 km
Temperature shock test chamber -70-220°C
VötschVT 7012 S2
VötschVT 7012 S2
Listing
Borken
18,513 km
Climate chamber with humidity 34 liters
WeissWKL 34/60 -60°C bis 150°C
WeissWKL 34/60 -60°C bis 150°C
Listing
Borken
18,513 km
Shock test chamber -80°C to +220°C
VötschVT 7012 S2
VötschVT 7012 S2
Listing
Borken
18,513 km
Shock test chamber +50 - 220°C -80 - +70°C
VötschVT 7012 S2 (6603)
VötschVT 7012 S2 (6603)
Listing
Borken
18,513 km
Shock test chamber
HeraeusHT 7012 S2
HeraeusHT 7012 S2
Listing
Borken
18,513 km
Shock test chamber –75°C to +220°C
VötschVT 7012 S2
VötschVT 7012 S2
Listing
Borken
18,513 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
VötschVT 7012 S2
Listing
Borken
18,513 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-15 -70°C bis +180°C
VötschVCS 7130-15 -70°C bis +180°C
Listing
Borken
18,513 km
Temperature test chamber 270 liters
VötschVTS³ 7027-25 -72°C bis +180°C
VötschVTS³ 7027-25 -72°C bis +180°C
Listing
Borken
18,513 km
Shock test chamber
VötschVT 7012 S3
VötschVT 7012 S3
Your listing has been deleted successfully
An error has occurred