Climate test chamber Temp. -70°C to +180°CVötsch 190 Liter
VCS 7018-5
Climate test chamber Temp. -70°C to +180°C
Vötsch 190 Liter
VCS 7018-5
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Climate test chamber Temp. -70°C to +180°C
- Manufacturer:
- Vötsch 190 Liter
- Model:
- VCS 7018-5
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A18736216
- Reference number:
- 24557
- Update:
- 26.06.2025
Description
Heraeus Vötsch
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Caedjv N Hc Ejpfx Ab Tja
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Type: VCS 7018-5
Climatic Test Chamber with Humidity Control, Water-Cooled
Caedjv N Hc Ejpfx Ab Tja
Test Chamber Dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing Dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Characteristics for Temperature Tests:
Temperature Range: -70°C to +180°C
Temperature Range: ± 0.1 to ± 0.5 K
Spatial Range: ± 0.5 to ± 2.0 K
Temperature Gradient: 1 to 4 K
Temperature Rate of Change according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Characteristic values for climatic tests:
Temperature range +10 to +95°C
Humidity range: 10 to 98% RH
Temperature deviation over time: ± 0.1 to ± 0.3 K
Temperature deviation over space: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Humidity fluctuation over time: ± 1 to ± 3% RH F.
Dew point range -3 to +94 °C
Electrical connection:
Nominal voltage: 3/N/PE AC 400V±10% 50Hz
Nominal power: 10 kW
Nominal current: 21 A
Fuse protection: 32 A slow-blow, provided by the customer
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Borken
18,513 km
Salt spray chamber
WeissSC/KWT 450
WeissSC/KWT 450
Listing
Borken
18,513 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
WeissSB2/500/80 -75°C bis +180°C
Listing
Borken
18,513 km
Climate chamber
CTSC-40/200
CTSC-40/200
Listing
Borken
18,513 km
Corrosion test cabinet for salt spray
VLMCC 1000-FL HL V.745.672.120
VLMCC 1000-FL HL V.745.672.120
Listing
Tatabánya
18,028 km
CORROSION CHAMBER LIEBISCH
LIEBISCH Salzsprühnebel-Korrosionstest(2458)
LIEBISCH Salzsprühnebel-Korrosionstest(2458)
Listing
Borken
18,513 km
Temperature test chamber 350 liters
CTSC-40/350 -40/+180°C
CTSC-40/350 -40/+180°C
Listing
Črnomelj
18,317 km
Climate temperature system
CTS CLIMAT TEMPERATUR SISTEMCTS T-40/650/S Climate temperature siste
CTS CLIMAT TEMPERATUR SISTEMCTS T-40/650/S Climate temperature siste
Listing
Borken
18,513 km
Climate test chamber with humidity
Weiss -72°C bis +180°CWK3-340/70
Weiss -72°C bis +180°CWK3-340/70
Listing
Borken
18,513 km
Salt spray Salt spray chamber
LIEBISCH43046101
LIEBISCH43046101
Listing
Borken
18,513 km
Shock test chamber +50 - 220°C -80 - +70°C
VötschVT 7012 S2 (6603)
VötschVT 7012 S2 (6603)
Your listing has been deleted successfully
An error has occurred