Used Material testing for sale (495)
Sort results
- Lowest price Highest price
- Latest listings Oldest listings
- Shortest distance Farthest distance
- Latest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Latest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Latest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation A to Z
- Designation
- designation Z to A
- Designation
- Model A to Z
- Model
- Model Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest running time
- Runtime
- Relevance
- Relevance
Measuring & testing equipment Material testing
Listing

18,513 km
Temperature test chamber
Vötsch VTV 7060-10
Call
Condition: used, Heraeus Vötsch
Type: VTV 7060-10
Heraeus Vötsch temperature test chamber water-cooled
( with chamber feed-through for shaker for vibration testing )
The basic equipment, perfect down to the last detail:
Operating terminal Color touch panel
Microprocessor monitoring and control S!MCON/32*-NET
Digital I/O, potential-free
Independent, adjustable temperature limiter tmin/tmax
Adjustable software temperature limiter min./max.
Serial interface RS 232
Potential-free contact for test material switch-off
Water-cooled cooling unit
Calibration of 2 temperature values
Removable base with feed-through
2 pipe feed-throughs Ø 50 mm and Ø 125 mm
Vötsch temperature chamber VTV 7060-10
Test chamber capacity 600 liters
Performance for temperature tests
Temperature range -70/+180 °C
Temperature deviation in time ±0.1 to ±0.8 K
Spatial temperature deviation ±0.5 to ±2.0 K
Temperature gradient 1 to 4 K
Temperature change rate heating 9.5 K/min
Temperature change rate cooling 10.5 K/min
Thermal compensation at +20 °C 8000 W
Heat compensation at -20 °C 8000 W
Test chamber dimensions Width 800 mm Depth 800 mm Height 950 mm
External dimensions Width 1225 mm Depth 2890 mm Height 2150 mm
Height to lower edge of test chamber floor min/max 660/1380 mm
Feed-through for vibrator 710 mm Ø
Feed-through for vibrator 700/700 mm
Electrical connection 3/N/PE AC, 400 V±10 %, 50 Hz
Rated power 17 kW
Rated current 37 A
Sound pressure level - 1 m from the front 75 dB(A)
Refrigerant: R-404A / R-23
Weight approx. 1400 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Cgob Esu Tqnned Awxst
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Ceb Ed Ajqwim Eowxogt
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Unit dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Temperature change rate:
Heating 4.0 K/min
Cooling 3.0 K/min
Max. heat compensation at +20°C 4500 watts
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Temperature homogeneity in space ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Temperature test chamber
Vötsch VT 4011
Call
Condition: excellent (used), Vötsch temperature test chamber
Cgob Ed Awjq Ul T Aoxjt
Here we offer you a Heraeus Vötsch temperature test chamber.
Heraeus Vötsch temperature test chamber air-cooled
Test chamber capacity approx. liter 110
Test chamber dimensions: Width 560 mm Depth 350 mm Height 630 mm
External dimensions: Width 850 mm Depth 1030 mm Height 1640 mm
Temperature range: -40°C to +180°C
Sound pressure level approx.

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month
Listing

18,513 km
Shaker vibration test system
SentekL1024m mit PA115
Call
Condition: excellent (used), Sentek
Type: L1024m with PA115
Technical data:
Csb Ed Asr A Ezzswxegt
Sine Max (kgf / N): 1,000 / 9810
Random force rms (kgf / N): 1,000 / 9810
Shock force (6 ms) kgf: 2,000 / 19620
Usable frequency range Hz: 5-3500
Continuous movement test pk-pk mm: 51
Shock displacement pk-pk mm: 51
Max speed m/s: 2
Max acceleration sine peak m/s²: 980
Shaker:
Shaker head diameter mm: 240
Anchor insert pattern PCD mm plus 1 in the center: 8-100 / 8-200
Thread M10
Resonant frequency ±5% Hz: 3050
Max load capacity kg: 200
Natural frequency of the shear axis Hz: < 5
Stray flux density Gauss: < 10
Weight kg: 1150
Dimensions (W x D x H) mm: 884x890x841
Amplifier
Dimensions (W x D x H) mm: 580x850x1800
Amplifier Weight Uncrated kg: 290
Cooler
Type: VAPE500/P2
Dimensions (W x D x H) mm: 620x710x1120
Weight kg: 120
Total weight approx : 1540
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
-65° to 0°C and +50 to 200°C
Espec TSA-303EL-W Temperaturschockkammer
Call
Condition: excellent (used), Espec
Csb Edjvgw Uao Awxogt
Type: Espec Model: TSA-303EL-W
Water-cooled
Cold chamber: -65° to 0°C
Heating chamber: +50 to 200°C
System: Two-zone test by damper switching
Temperature fluctuation ±0.5°C
Hot chamber:
Temperature Heating time: Ambient temp. to +200°C within 15 min.
Cooling chamber:
Temperature pull-down time: ambient temp. to -70°C within 40 min.
Temperature recovery: within 10 min.
Internal dimensions (W x H x D mm): 970 x 460 x 670
External dimensions (W x H x D mm): 1870 x 1900 x 1770(1805)
Power supply: 400 V AC 50Hz: 70 A
Refrigerant: R449A 5 kg R23 2.0 kg
Weight: approx. 1450 kg
Year of construction 2018
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Dryer for coating materials
Vötsch LTU 60/60
Call
Condition: excellent (used), Vötsch
Type: LTU 60/60
Cjb Edoun Rr Re Awxjgt
Heraeus Vötsch dryer for coating materials
Maximum concentration of flammable substances of 40 % of the lower explosion limit (LEL)
Highest temperature of the heating surface above 750 °C
Device description:
Technical data:
Interior (usable space) 0.216 m3
Internal dimensions: Width 600 mm Height 600 mm Depth 600 mm
External dimensions: Total width 796 mm Height 1725 mm Depth 850 mm
Loading / load capacity
Total roller conveyor 55 kg
Loading height above installation floor 820 mm
Weight (net) kg 275
Minimum exhaust air volume flow 96 m3/h
Purge time 5-fold air change 90 sec.
Increased recirculation air volume flow 33 m3/h
Total vapor space 0.414 m3
Sound pressure level (according to DIN 45635) < 70 dB(A)
Switch-off temperature
Temperature limiter (TB) fixed setting 300 °C
Temperature selector limiter (TWB) adjustable above nominal temperature 20
Temperature safety class (according to EN 60519-2)
Temperature limiter (TB) 1
Temperature selector limiter (TWB) 2
Nominal temperature 200 °C
Electrical data
Rated voltage / frequency 400V, 3/(N)PE, AC 50/60 Hz
Rated current 12.0 A
Nominal power 6.0 kW
Connected load 7.0 kW
Weight: 275kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Climate cell
TiraTCZ 4020 S-2k
Call
Condition: good (used), TIRA
Type: Walk-in climate simulation cell TCZ 4020 S-2k
Technical data:
Temperature range -40...+140 °C
Csbjuviume Ed Awxsgt
Temperature tolerance: +/- 1.0°C
Temperature change rate: 2 K/min
Humidity range
10...approx. 95 % r.h.
Humidity tolerance
+/- 5.0 % r.h.
Dimensions:
Test chamber volume: 19m³
External dimensions (WxDxH) approx. 2660mm X 4960mm X 3300mm
Test chamber (WxDxH) approx. 2270mm Χ 3190mm Χ 2756mm
Door opening (WxH) approx. 2270mm X 2756mm
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Temperature cabinet -70 to +180°C
EspecEGN28-6CWL
Call
Condition: excellent (used), Espec
Type: EGN28-6CWL
Espec temperature water cooled
Temperature test chamber N series
Power supply:
AC 400 V 3-phase 50/60Hz 38A
Cgebeuzva Uj Ed Awxst
Temperature range -70 to +180°C
Temperature change rate
Heating 10 °K/min
Cooling 5.5 °K/min
Internal dimensions W x H x D in mm 1000 x 1000 x 800
External dimensions W x H x D in mm 1205 x 1920 x 2159
Useful volume 800 liters
Refrigerant R-404A
Refrigerant R- 508A
Weight: approx. 695 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Temperature test chamber
Vötsch VTS 7034-5
Call
Condition: used, Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Csbeu Hf H Is Ed Awxjgt
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Climate test chamber 1000 liters
CTSC-55/1000 Li -50°C bis 100°C
Call
Condition: excellent (used), CTS
Climate test chamber C-55/1000 Li water-cooled
Temperature range: -50°C to +100°C
Humidity range: 5 to 95% RH
Dew point range: 5°C to +78°C
Rated voltage: 400V 3/N 50Hz
Rated power: 9.5 kW
Cjbova Hi He Ed Awxsgt
Nominal current: 18 A
Compressor: TFH2511Z / TFH2511Z Refrigerant R404A/R23
The type designation of the CTS cabinet series is composed as follows:
z. e.g. type C -55/1000/Li
1) C means: climate
2) -55 means: lower temperature -55 °C
3) 1000 means: 1000 liter test chamber volume
4) Li means: special equipment for
tests with lithium-ion accumulators
Control:
32 bit controller
LCD control panel
Digital display of set and actual values
Numerical input of setpoints
Error messages in plain text
Ethernet interface
RS 232 interface
Free switching channels for on-site
test material control
Test room lighting:
energy-efficient, high-intensity LED light strip mounted on the door
Insert grid:
Stainless steel, support surface 970 x 980 mm
Load per shelf max. 35 kg
Total load with max. grating load 100 kg
1a Feed-through NW50
1b Feed-through 2x NW125
1c Entry port 2x Rp 314°
for Minimax
Technical performance data:
Temperature tests:
Temperature range -50°C to +100°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 2.5 K/min
Cooling 2.5 K/min
Heat compensation
approx. 4000 W at +20°C
approx. 2200 W at -40°C
Climate tests:
Temperature range +5 °C to +95 °C
Humidity range 5% to 95% rel. humidity
Dew point range +5°C to 78°C
Temperature deviation ≤ ±1.0 K in time
Humidity deviation ≤ ±3.0% relative humidity over time
The technical data refers to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without heat compensation and without additional equipment.
Options may influence the performance data.
Dimensions:
Test volume 1000 liters
Test chamber dimensions Height, approx. 1000 mm, width, approx. 860 mm, depth, approx. 1100 mm
External dimensions Height, approx. 1950 mm, width, approx. 1270 mm, depth, approx. 1900 mm
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Nominal current 18 A
Rated power 9.5 kW
Protection class IP 54
Sound pressure level < 58 dB(A)
(according to DIN EN ISO 3744
measured at a distance of 1 m from the front)
Mass approx. 1000 kg
Heat output to the installation room 10.4 kW
Cooling unit:
water-cooled, low-noise, fully hermetic
Infinitely variable output adjustment via electronic monitoring and control system,
environmentally friendly refrigerant R404A/R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Shock test chamber +50°C to +220°C
VötschVT 7012 S2 -80°C bis +70°C
Call
Condition: excellent (used), Vötsch
Type: VT 7012 S2
Water-cooled
Two-chamber design
Hot chamber:
The temperature control of the hot chamber ranges from +50°C to +220°C
Temperature deviation over time in the center of the working chamber ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 11 K/min
Cgeb Ed Ajtrmp Dswxet
Cold chamber:
the cold chamber from -80°C to +70°C
Temperature deviation temporally in the center of the chamber ± 1 K
Spatial temperature deviation ± 2 K
Temperature change rate
Heating 2 K/min
Cooling 3 K/min
Test chamber volume 125 liters
Temperature range hot chamber +50°C to +220°C
Temperature range cold chamber -80°C to +70°C
Test chamber dimensions width 470mm depth 650mm height 410mm
External dimensions Width 930mm Depth 2115mm Height 1970+mm
Feedthrough ∅ 67mm
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power 10 kW
Rated current 25 A
Refrigerant R404A / R23
Weight: 1000 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Climate test chamber with humidity 1100 liters
EspecARL-1100 -40°C bis 180°C
Call
Condition: excellent (used), Espec
Type: ARL-1100
Air-cooled climatic test chamber
Temperature range: -40 °C to +180 °C
Heating rate of change: up to 4.7 K/ min.
Cooling rate of change: up to 4.4 K/ min.
Humidity range: 10 to 98% r. h.
Internal dimensions: Width 1100 mm Height 1000 mm Depth 1000 mm
External dimensions: Width 1300 mm Height 1955 mm Depth 2005 mm
approx. 1100 liters
Rated current: AC 400 V 3φ,
50Hz 23 A
Weight approx. 600 kg
Refrigerant: R404A
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
Cjb Ejt Sug Hsd Awxogt
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Temperature test chamber
Vötsch VTS³ 7018-5
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7018-5
Water-cooled
Ceb Esn E Sk Ejd Awxsgt
Test chamber dimensions: Width 580 mm x depth 450 mm x height 750 mm
Housing dimensions: Width 900 mm x depth 1550 mm x height 1850 mm
Temperature test:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: cooling 7.5 K/min
Test chamber volume: 190 liters
Nominal voltage: 400V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Climatic chamber
VötschVCS 7033
Call
Condition: excellent (used), Heraeus Vötsch climatic chamber
Here we offer you a Heraeus Vötsch climatic chamber.
Csb Eepz H Hxod Awxjgt
Vötsch climatic chamber VCS 7033 water cooled
Temperature range: -70°C to +180°C
Temperature change rate:
Heating 7.5 K/min.
Cooling 6,5 K/min.
Humidity range: 10% to 98% r.H.
Temperature deviation temporal ± 0.5 K
Temperature deviation time-related ± 1.5 K
Test chamber dimensions: Width 675 mm x Depth 650 mm x Height 760 mm
Housing dimensions: Width 930 mm x depth 1565 mm x height 1840 mm
Lateral feedthrough 90mm ∅
approx. 330 L Weight: 600 kg
voltage: 3/N/PE AC 400V ±6/-10% 50Hz
rated power 9,5 kW
Rated current 17 A
Refrigerant R404A / R23
Type: VCS 7033
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

18,513 km
Climatic chamber
VötschVC³ 4100
Call
Condition: excellent (used), Vötsch climatic test chamber
Here we offer a Vötsch climatic test chamber.
Designation VC³ 4100 Air-cooled
With temperature change rate of 3 K/min
Test chamber dimensions: Height 950 mm x width 1100 mm x depth 950 mm
Unit dimensions: Height 2000 mm x width 1300 mm x depth 1916 mm
Volume: 990 liters
Feed-through: Ø 125 mm Ø 50 mm
Data for temperature tests:
Temperature range -42°C to +180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature homogeneity in space ± 0.5 to ± 1.5 K
Temperature change rate:
Heating 4.0 K/min
Cooling 3.0 K/min
Max. heat compensation at +20°C 4500 watts
Data for climate tests
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% r. h.
Temperature deviation temporal ± 0.1 to ± 0.3 K
Temperature homogeneity in space ± 0.5 to ± 1.0 K
Humidity deviation temporal ± 1 to ± 3% r. h.
Heat compensation max. 500 W
Voltage: 3/N/PE AC 400V ± 10% 50Hz
Rated power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404 A
Weight approx. 840 kg
Type: VC³ 4100
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Cgjb Ed Awjqmn A Nsxst
Listing

18,513 km
Multifunctional cabinet with humidity
BIAC890TH +15°C bis +30°C
Call
Condition: excellent (used), Here we offer a BIA multifunctional cabinet.
BIA Multifunctional Cabinet
Temperature range +15°C to +30°C and humidity
Refrigerant: R-404A
230V 50Hz 10A
Type: C890TH
For you as a buyer the following information for your safety!
The following points are carried out at our offered chambers in advance:
Ceb Eefktnyod Awxogt
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We can answer further questions for you on the phone.
Listing

18,513 km
Climate chamber
CTSC-40/200
Call
Condition: excellent (used), CTS test cabinet climatic chamber
Here we offer a CTS climatic chamber.
Air cooled
Test chamber volume: 200 liters
Test chamber dimensions: Height 750, width 650, depth 400 mm
External dimensions: Height 1800, width 920, depth 1345 mm
Temperature working range
temperature range: -40°C / +180°C
cooling speed: 4 K / min
heating speed: 4 K / min
Max. heat radiation at +20°C: 3500 W
Temperature constancy, temporal: ≤± 0.3 K.
Climate working range
Temperature range: +10°C to +95°C.
Humidity range: +10%to +98% r.H.
Connection: 400 V +6% -10%, 3/N, 50 Hz
Rated current 9.4 A
Rated power 4,8 kw
Weight: approx. 450 kg
Cebohwhzwo Ed Awxsgt
Refrigerant R404A
Type: CTS C-40/200
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

18,513 km
Temperature chamber
VötschVT/S 7050
Call
Condition: excellent (used), Vötsch temperature chamber
Cob Ed Awoic Rf Njxjgt
Here we offer a Vötsch temperature chamber.
Converted to R452a
Vötsch temperature chamber water cooled
Outside: W x D x H (mm) 1100 x 2200 x 2320
Interior: W x D x H (mm) 800 x 800 x 790
Volume test chamber 500 L
Characteristic values for temperature tests:
Temp. range -70°C to +180°C
Speed heating : 3 K/min
Cooling speed: 2 K/min
Electrical power:
Rated power 15 kW Rated current 26 A
400 V +6/-10% 3/N 50Hz
Weights: 675 kg
Type: VT/S 7050
Refrigerant: R452a + R23
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

18,513 km
Climatic chamber
RS Simulatoren
Call
Condition: excellent (used), RS Simulators
Here we offer a climatic test chamber.
Water cooled
300 liters
Temperature range from -75 °C to +180 °C
Time deviation +- 0.2 K to +- 0.8 K
Average heating rate: approx. 2.1 K/min
Average cooling rate: approx. 1.2 K/min
Humidity range from 10 % to 98 % rel. humidity
Working climate range
Temperature: 10 °C to 95 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 1000 mm 1800 Height mm 1400 Depth mm
Voltage: 3x400V/N/PE Current: 40A
Refrigerant: R404a / R23
Type: KS 300 / 75
Weight: 630 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See pictures)
Csb Ed Aeiivgvowxjgt
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

18,513 km
Temperature test chamber
WEISSWT-600/70
Call
Condition: excellent (used), Weiss temperature test chamber
Here we offer a temperature test chamber.
Weiss temperature test chamber water cooled
Technical data:
Test cabinet designation: WT-600/70
Outer dimensions with hinges and door lock
height 1995 mm, width 1090 mm, depth 1660 mm
Outer dimensions without hinges and door lock
height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions:
Ceb Esiqk Abed Awxegt
Height 950 mm, width 800 mm, depth 800 mm
Test chamber capacity: approx. 600 liters
cold / heat operation -70°C to 180°C
Temperature change per time
cooling approx. 2.5 K/min
Heating up approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Fuse on site: 32 A slow blow
Permissible test material weight
Total load of grate supports 80kg
test chamber floor 80kg, insert grate 40kg
Refrigerant: R 404A/R23
Weight: 675kg
Type: WT-600/70
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing

18,513 km
Temperature test chamber
CTS TSR-30/1000
Call
Condition: good (used), CTS
Type: TSR-30/1000
Cgob Eorivfcsd Awxst
Water-cooled
The type designation of the CTS enclosure series is made up as follows:
z. e.g. type TSR -30/1000
1) T means: Temperature
2) S means: stress screening
3) R means: external conditioning
4) -30 means: lower temperature -30 °C
5) 1000 means: 1000 liter test chamber volume
Technical performance data:
A) TSR-30/1000 basic device without hose connections,
i.e. when used as a stand-alone temperature test chamber
Temperature tests:
Temperature range -40°C to +180°C
Final temperature -45°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 6.0 K/min
Cooling 5.0 K/min
Heat radiation
approx. 5000 W at +20°C
approx. 4200 W at ± 0°C
approx. 3000 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Air volume flow
approx.2000m³/h
B) TSR-30/1000 basic unit with hose connections,
for connection to an external test room provided by the customer
Temperature tests:
Temperature range -30°C to +170°C
Temperature deviation ≤ ±0.1 to 0.5 K in time
Average rate of temperature change,
measured with short-circuited circuit
Heating 4.0 K/min
Cooling 4.0 K/min
in the range from +150°C to -10°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment,
measured with short-circuited circuit
Attention: The external test chamber provided by the customer must be absolutely tight and appropriately insulated,
any feed-throughs must be optimally sealed on site.
Dimensions:
Test volume 1000 liters
Air circulation connection Ø 200 mm
Test chamber dimensions Height 900 mm Width 1000 mm Depth 1100 mm
External dimensions Height 1950 mm Width 1270 mm Depth 2245 mm
Technical design:
Refrigeration unit:
water-cooled, low-noise, fully hermetic
Infinitely variable capacity adjustment through
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
Fully opening door, door hinge on the left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 mm
Max. load per shelf 35 kg
Total load with max. shelf load 100 kg
Test area lighting: Halogen lamp 20 W, 12 V
Control:
- 32 bit controller
- LCD control panel
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 13.3 kW
Protection class IP 22
Sound pressure level < 60 dB(A)
Weight approx. 850 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing

18,513 km
Temperature shock test system
RS SimulatorenST2K320/45
Call
Condition: excellent (used), RS Simulators
Type: ST2K320/45
Water-cooled shock test system
Working climate area
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Temperature: +12 °C to +30 °C
Humidity: 25% to 75% relative humidity
Dimensions Width 1100 mm Height 2300 mm Depth 2300 mm
Test chamber dimensions: Width 470 mm Depth 700 mm Height 440 mm
Electrical power supply:
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 850 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Cgebetqcu Ej Ed Awxet
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Incubator incubator
HeraeusB 6420
Call
Condition: good (used), machine/vehicle number: HE-14804, Here we offer an incubator.
Volume 409 liters
Manufacturer: Heraeus
Size: 74.5 x 79 x 181 cm WxDxH
Internal dimensions: 55 x 55 x 136 cm WxDxH
Nominal temperature: 70°C
Connection: 230V 50 Hz 3.7 A
Weight: approx. 157 kg
Cgob Ejc N N Rcjd Awxst
Type: B 6420
Condition: second-hand / used
Scope of delivery: (see pictures)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing

18,513 km
Vibration generator | Power amplifier
RMSSW 1511/2
Call
Condition: good (used), RMS
RMS vibration exciter with power amplifier and cooling fan
Vibration exciter SW 1511/2
Power amplifier TGD 3000-000 00
IN: 3X400V-50Hz 14.5 KVA
Cgsb Edodhxlgo Awxst
Cooling fan SWG 108
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing

18,513 km
Temperature test chamber -20°C...+140°C
TIRATTRE 2001 S
Call
Condition: excellent (used), Here we offer a TIRA temperature test chamber.
TIRA temperature test chamber air-cooled
Cjbjnyh T Se Ed Awxogt
The chamber has the option for an external test box with external sensor connection
can therefore also be used as an external temperature control unit.
Temperature range -20°C...+140°C
Temperature stability over time ± 0.1°C...± 0.3°C
External dimensions Width 860 mm x depth 1500 mm x height 2100 mm
Test chamber dimensions width 601 mm x depth 545 mm x height 692 mm
Electrical connection 400V +6% / -10% 50Hz 3P+N+PE
Rated current: 10.0 (max.17) A
Rated power: 5.2 (max.9.0) kW
Net weight: 735 kg
Refrigerant: R404A / R23
Type: TTRE 2001S
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make the search easier for you
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
Used Material testing (495)
Search Machineseeker now with more than 200,000 used machines:This may be of interest to you

Find out now
+44 20 806 810 84
+44 20 806 810 84
Create listing
*per listing / month