Climate test chamber with humidityWeiss -72°C bis +180°C
WK3-340/70
Climate test chamber with humidity
Weiss -72°C bis +180°C
WK3-340/70
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Climate test chamber with humidity
- Manufacturer:
- Weiss -72°C bis +180°C
- Model:
- WK3-340/70
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A18791221
- Reference number:
- 24566
- Update:
- 02.07.2025
Description
Weiss
Type: WK3-340/70
Weiss Air-Cooled Climatic Test Chamber
Touch Panel Control Unit
All control and operating commands can be triggered by simply touching the function symbols on the touch panel control unit.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Plug-ins
The test chamber is equipped with plug-ins on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Pjdpjv Sr Hzjfx Adnogw
Penetration included in standard equipment
R1: NW 125 mm
L1: NW 85 mm
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Minimum temperature -72°C
Maximum temperature +180°C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 1.5 K
Temperature change rate, cooling 3 K/min
Temperature change rate, heating 3 K/min
Data for climatic tests:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Operating data:
Test room lighting: 2 x 24V, 50W halogen bulb
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Fuse: 16 A slow-blow (on-site)
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Type: WK3-340/70
Weiss Air-Cooled Climatic Test Chamber
Touch Panel Control Unit
All control and operating commands can be triggered by simply touching the function symbols on the touch panel control unit.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Plug-ins
The test chamber is equipped with plug-ins on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Pjdpjv Sr Hzjfx Adnogw
Penetration included in standard equipment
R1: NW 125 mm
L1: NW 85 mm
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Data for temperature tests:
Minimum temperature -72°C
Maximum temperature +180°C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 1.5 K
Temperature change rate, cooling 3 K/min
Temperature change rate, heating 3 K/min
Data for climatic tests:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range: 10 to 98% RH
Temperature deviation, over time: ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial: ± 0.5 to ± 1 K
Humidity deviation, over time: ± 1 to ± 3% RH
Operating data:
Test room lighting: 2 x 24V, 50W halogen bulb
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 16 A
Nominal power: 4.9 kW
Fuse: 16 A slow-blow (on-site)
Refrigerant: R-452A/R23
Weight: Approx. 585 kg
For your safety, the following information is provided as a buyer!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Rimini
18,546 km
Tensile / Compression testing machine
ZwickRoell GmbHZ005TN
ZwickRoell GmbHZ005TN
Listing
Cestona
19,683 km
Bar loader
LNSECO LOAD
LNSECO LOAD
Listing
Iserlohn
18,518 km
CNC 4th axis
NIKKENCNC -200
NIKKENCNC -200
Listing
Contamine-sur-Arve
18,946 km
Cnc multispindle lathe
INDEXMS 32 C
INDEXMS 32 C
Listing
Saarbrücken
18,716 km
Multisensor CMM with guarantee
MahrMS2VT Refurbished mit Garantie
MahrMS2VT Refurbished mit Garantie
Listing
Strassberg
18,652 km
High speed press
BRUDERERBSTA 50 USL
BRUDERERBSTA 50 USL
Listing
Switzerland
18,782 km
AGIECHARMILLES FORM P350 – 2023 – EDM Die sinking machine
AGIECHARMILLES +GF+FORM P350
AGIECHARMILLES +GF+FORM P350
Listing
Contamine-sur-Arve
18,946 km
Horizontal machining center
QUASERHX404BP/15C
QUASERHX404BP/15C
Listing
Borken
18,513 km
Climate chamber with humidity 34 liters
WeissWKL 34/60 -60°C bis 150°C
WeissWKL 34/60 -60°C bis 150°C
Listing
Borken
18,513 km
Climate chamber
VötschVC³ 4060
VötschVC³ 4060
Your listing has been deleted successfully
An error has occurred




























































































