MACSQuant 16 AnalyzerMiltenyi Biotec
MACSQuant 16 Amalyzer
MACSQuant 16 Analyzer
Miltenyi Biotec
MACSQuant 16 Amalyzer
Year of construction
2024
Condition
Used
Location
Chorvátsky Grob 

Show images
Show map
Machine data
- Machine type:
- MACSQuant 16 Analyzer
- Manufacturer:
- Miltenyi Biotec
- Model:
- MACSQuant 16 Amalyzer
- Machine number:
- 40423
- Year of construction:
- 2024
- Condition:
- like new (used)
- Functionality:
- fully functional
Price & Location
- Location:
- Triblavinská 3191, 900 25 Chorvátsky Grob, Slovensko
Call
Details about the offer
- Listing ID:
- A20114535
- Update:
- 01.10.2025
Description
The MACSQuant Analyzer 16 is a benchtop, automated flow cytometer engineered for multi-parameter cell analysis, offering convenience, sensitivity, and flexibility for both research applications and advanced cell therapy workflows.
As part of the MACSQuant product line, this model improves upon previous generations by delivering 16 optical parameters (i.e., multiple fluorescence detection channels) while maintaining a compact footprint and a high degree of automation.
Typical applications include immunology, immunophenotyping, cell and gene therapy (CGT) analytics, quality control processes, and general cell biology research.
Key Features & Capabilities
Highlighted advantages and system features:
Feature Description / Details
Optics & Detection
- Outfitted with three spatially separated lasers: 405 nm, 488 nm, and 640 nm.
- Provides 16 detection/optical parameters (multiple fluorescence channels, plus scatter signals).
- Signal detection covers FSC (forward scatter), SSC (side scatter), and multiple fluorescence channels (e.g., V1–V5, B1–B6, R1–R3), each equipped with optimized photomultiplier tubes (PMTs).
Fluidics / Sample Handling
- Minimum sample uptake: as little as 1 µL (recommended ~25 µL for precise volumetric counting).
- Adjustable sample flow rates: 25, 50, or 100 µL/min, or automated regulation to achieve target event rates (e.g., 500, 1,000, or 2,000 events/second).
- Maximum event rate: up to approximately 15,000 events/second (ALT mode).
- Compatible with various sample vessels, including 1.5, 2, and 5 mL tubes, tube racks, and 96-well plates. Transition between tubes and plates is user-friendly.
- Utilizes an automated robotic needle arm for sample aspiration, thorough mixing, and automated washing of both the injection port and needle before and after runs.
Automation & Workflow
- Full automation for maintenance routines, PMT gain calibration, fluorescence compensation, sample acquisition, and analysis.
- "Express Modes" (pre-set protocols) and templates support reproducible sample acquisition and data processing workflows.
- Harmonization features for cross-instrument and multi-site data alignment, promoting data standardization for multi-center studies.
- Regulatory and compliance support: offers 21 CFR Part 11-compatible features (audit trail, user management, electronic signatures, and reporting), making it ideal for clinical and translational research labs.
Sensitivity & Performance
- High fluorescence sensitivity: e.g., for standard dyes — FITC < 110 MESF, PE < 75 MESF, APC < 100 MESF
Dsdpjxg Ndisfx Afzoku
- High precision:
The listing was translated automatically. Translation errors are possible.
As part of the MACSQuant product line, this model improves upon previous generations by delivering 16 optical parameters (i.e., multiple fluorescence detection channels) while maintaining a compact footprint and a high degree of automation.
Typical applications include immunology, immunophenotyping, cell and gene therapy (CGT) analytics, quality control processes, and general cell biology research.
Key Features & Capabilities
Highlighted advantages and system features:
Feature Description / Details
Optics & Detection
- Outfitted with three spatially separated lasers: 405 nm, 488 nm, and 640 nm.
- Provides 16 detection/optical parameters (multiple fluorescence channels, plus scatter signals).
- Signal detection covers FSC (forward scatter), SSC (side scatter), and multiple fluorescence channels (e.g., V1–V5, B1–B6, R1–R3), each equipped with optimized photomultiplier tubes (PMTs).
Fluidics / Sample Handling
- Minimum sample uptake: as little as 1 µL (recommended ~25 µL for precise volumetric counting).
- Adjustable sample flow rates: 25, 50, or 100 µL/min, or automated regulation to achieve target event rates (e.g., 500, 1,000, or 2,000 events/second).
- Maximum event rate: up to approximately 15,000 events/second (ALT mode).
- Compatible with various sample vessels, including 1.5, 2, and 5 mL tubes, tube racks, and 96-well plates. Transition between tubes and plates is user-friendly.
- Utilizes an automated robotic needle arm for sample aspiration, thorough mixing, and automated washing of both the injection port and needle before and after runs.
Automation & Workflow
- Full automation for maintenance routines, PMT gain calibration, fluorescence compensation, sample acquisition, and analysis.
- "Express Modes" (pre-set protocols) and templates support reproducible sample acquisition and data processing workflows.
- Harmonization features for cross-instrument and multi-site data alignment, promoting data standardization for multi-center studies.
- Regulatory and compliance support: offers 21 CFR Part 11-compatible features (audit trail, user management, electronic signatures, and reporting), making it ideal for clinical and translational research labs.
Sensitivity & Performance
- High fluorescence sensitivity: e.g., for standard dyes — FITC < 110 MESF, PE < 75 MESF, APC < 100 MESF
Dsdpjxg Ndisfx Afzoku
- High precision:
The listing was translated automatically. Translation errors are possible.