Used Vötsch Vc7018 for sale (82)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Darmstadt
18,574 km
Vötsch VC7018
VötschVC7018
Call
Year of construction: 2010, operating hours: 18,766 h, condition: excellent (used), functionality: fully functional, machine/vehicle number: 58566150370010, VÖTSCH VC7018 CLIMATE TEST CHAMBER – INDUSTRIAL QUALITY FOR PRECISE TEMPERATURE AND HUMIDITY TESTING
For sale is a high-quality Vötsch VC7018 Climate Test Chamber in very good condition. The unit is ideally suited for demanding temperature and humidity testing applications in research, development, quality assurance, and industrial environments.
Vötsch is one of the world's leading manufacturers of environmental simulation and testing equipment, renowned for precision, reliability, and long service life. The VC7018 has been designed for reproducible climate and temperature testing and provides excellent temperature and humidity uniformity throughout the test chamber.
The spacious stainless-steel workspace offers ample room for a wide range of test specimens and applications. Its powerful air circulation system ensures homogeneous climate conditions and reliable test results. The intuitive touchscreen controller allows simple and user-friendly operation.
TECHNICAL FEATURES
• Manufacturer: Vötsch Industrietechnik
• Model: VC7018
• Type: Climate Test Chamber
• Temperature Range: -70 °C to +180 °C
• Humidity Range: 10 % to 98 % RH
• Stainless-Steel Interior
• Dynamic Air Circulation System
• Large Viewing Window
Dodpfxozdp Tlo Ac Heci
• Touchscreen Controller
• Heavy-Duty Industrial Design
• Suitable for Continuous Operation
APPLICATIONS
• Electronics Industry
• Automotive Industry
• Aerospace Industry
• Material Testing
• Research & Development
• Quality Assurance
• Aging and Reliability Testing
KEY BENEFITS
✓ Precise temperature and humidity control
✓ Excellent climate uniformity throughout the chamber
✓ High-quality stainless-steel workspace
✓ User-friendly operation
✓ Robust and durable construction
✓ Ideal for laboratory and production environments
✓ Proven Vötsch technology and reliability
CONDITION
The unit is in very good used condition. The interior is clean and the chamber is in overall excellent condition. Inspection and functional testing are welcome by appointment.
Listing
Borken
18,513 km
Climate test chamber with humidity, 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Dedpfx Aszh Huhec Heci
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Wymysłów
17,869 km
Vötsch VT 7004 – climatic chamber / temperature chamber
Vötsch VT 7004 – komora klimatyczna / komora temperaturowaVötsch VT 7004 – komora klimatyczna / komora temperaturowa
Call
Condition: excellent (used), For sale: a Vötsch VT 7004 climate chamber, designed for precise research and testing under controlled temperature conditions. This unit is suitable for use in laboratories, quality control departments, materials research, electronics, and the automotive industry.
The chamber is equipped with an electronic temperature controller, an efficient cooling system, and a forced air circulation system that ensures uniform temperature distribution throughout the working chamber. The interior is made of stainless steel, which facilitates cleaning and ensures high durability.
Dsdpfx Acszi U Tne Hjci
Technical data:
Manufacturer: Vötsch Industrietechnik GmbH
Model: VT 7004
Year of manufacture: 2000
Device number: 58566024350010
Power supply: 230 V AC, 50 Hz
Rated power: 2.0 kW
Rated current: 10 A
Refrigerant:
R404A – 0.7 kg
R23 – 0.22 kg
Maximum working pressure: 25 bar
Interior: stainless steel
Electronic temperature controller
Forced air circulation
Door with silicone seal
Lighting and service access port in the chamber
Compact design
Condition:
Used unit.
Visually in good condition.
The chamber is clean and complete.
Sold in the exact condition as shown in the pictures.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Wymysłów
17,869 km
Vötsch VTL 7010 – climate chamber / temperature test chamber
Vötsch VTL 7010 – komora klimatyczna / komora do badań temperaturowychVötsch VTL 7010 – komora klimatyczna / komora do badań temperaturowych
Call
Condition: excellent (used), For sale is a professional Vötsch VTL 7010 climate chamber, designed for conducting temperature tests and simulating environmental conditions. The device is used in laboratories, quality control departments, research and development centers, and for testing electronic, automotive, and mechanical components.
Dsdpfx Ajzi T Nhec Heci
The chamber is in good working order – the touchscreen starts up correctly and displays the main menu and the current operating temperature, as confirmed by the photos.
Technical specifications:
Manufacturer: Vötsch Industrietechnik GmbH
Model: VTL 7010
Year of manufacture: 2010
Temperature range: -70°C to +180°C
Heating/cooling rate: approx. 3.5 K/min
Refrigerant:
R404A – 0.8 kg
R23 – 0.2 kg
Power supply: 230 V AC, 50 Hz
Rated power: 3.5 kW
Rated current: 15.2 A
Operating pressure: 8 bar
Control via a color touchscreen
Working chamber made of stainless steel
Door with a viewing window
Adjustable internal shelves
CE marking
Applications
The device is ideally suited for:
temperature tests,
material testing,
testing electronics and components,
durability tests,
quality control,
research and development work.
Condition:
used,
functional,
control panel operates correctly,
internal chamber is clean and well-maintained,
normal signs of wear and tear,
sold exactly as shown in the pictures.
Included:
Vötsch VTL 7010 climate chamber,
2 perforated shelves,
built-in control panel.
Listing
Borken
18,513 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Type: VCS 7034-5
Climate Test Chamber Water-Cooled
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation spatially: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 3.5 K/min
Dedpfx Acjzizl Dj Hsci
Heating: 6.8 K/min
Heat compensation at +20°C: 3,000 W / at -20°C: 3,000 W
Temperature calibration points: +23°C and +80°C
Performance for climate tests:
Temperature range: +10 to +95°C
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Humidity deviation over time: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climatic calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions:
Width: 580 mm, Depth: 765 mm, Height: 750 mm
External dimensions:
Width: 870 mm, Depth: 1595 mm, Height: 1775 mm
Feedthroughs:
1 x approx. 50 mm Ø, left side
2 x approx. 125 mm Ø, left side
1 x approx. 125 mm Ø, right side
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R404A / R-23
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and errors!)
If you have further questions, we are happy to answer them by phone.
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
With temperature change rate of 5 K/min
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Dedpjziyx Nofx Ac Heci
Refrigerant: R404A / R-23
Weight approx. 570 kg
For your security as a buyer, please note the following:
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.
Listing
Borken
18,513 km
Temperature test chamber 990 liters
VötschVT³ 4100 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4100
Water-Cooled Temperature Test Chamber
S!MCON/32.NET (with Touch Panel)
Control System Features:
- Color touchscreen with intuitive menu navigation (typically 5.7" or larger)
- Programming of temperature/humidity profiles with ramps and dwell times
- Data acquisition & logging (e.g., temperature profile, alarms)
- USB port for data export (CSV, optionally S!MPATI compatible)
- Network interface (Ethernet) for remote monitoring and control
- User management with password protection
- Interfaces: Volt-free contacts, optionally Modbus or Profibus
VT³ 4100 – Technical Specifications (Temperature Test Chamber)
- Test volume: 990 liters
- Temperature range: -40 °C to +180 °C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1.5 K
- Temperature gradient: 1 to 3 K
- Temperature change rate (per IEC 60068-3-5):
• Heating: 4.0 K/min
• Cooling: 3.0 K/min
- Maximum heat compensation capacity: 4500 W
- Calibration values: +23 °C and +80 °C
- Internal dimensions (W×D×H): 1100 × 950 × 950 mm
- External dimensions (W×D×H): 1390 × 1955 × 1995 mm
Feed-Throughs:
The chamber is equipped with feed-throughs on both the right and left sides, allowing insertion of measuring cables and test devices into the test space.
• 1 × L1 nominal width 50 mm
• 1 × R1 nominal width 125 mm
• 3 × R1 nominal width 50 mm
Electrical connection: 3/N/PE AC, 400V ±10%, 50Hz
Power consumption: 11.5 kW
Rated current: 22 A
Noise level: approx. 62 dB(A)
Refrigerant: R452A
Weight: 920 kg
Important information for buyers:
For your security, the following measures are carried out on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Dcodpjziyxpsfx Ac Hoi
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data; information may be subject to alteration!)
For any further questions, feel free to contact us by phone.
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Dcodpjziyxiofx Ac Hsi
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Borken
18,513 km
Climatic chamber
VötschVC³ 4100
Call
Condition: excellent (used), Vötsch Climate Test Chamber
We offer a Vötsch climate test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
External dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Feed-throughs: Ø 125 mm, Ø 50 mm
Specifications for temperature tests:
- Temperature range: -42°C to +180°C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature uniformity: ±0.5 to ±1.5 K
- Temperature change rates:
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
- Maximum heat compensation at +20°C: 4500 W
Specifications for climate tests:
- Temperature range: +10°C to +95°C
- Dew point range: -3°C to +94°C
- Humidity range: 10 to 98% r.H.
- Temporal temperature deviation: ±0.1 to ±0.3 K
- Spatial temperature uniformity: ±0.5 to ±1.0 K
- Temporal humidity deviation: ±1 to ±3% r.H.
- Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
Important buyer information:
The following procedures are carried out on all our chambers prior to sale:
1. Functional checks and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (See picture)
(Technical data subject to change and errors excepted!)
Dcodpfx Acoziywls Hei
For further questions, please feel free to contact us by phone.
Listing
Borken
18,513 km
Temperature test chamber
VötschVT³ 4150/S
Call
Condition: excellent (used), Vötsch
Model: VT³ 4150/S
Vötsch Temperature Test Chamber
Water-cooled
Rated voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 11.5 kW; Rated current: 22.0 A
Change rate (cooling): approx. 3.5 K/min
Change rate (heating): approx. 4 K/min
Temperature testing
Temperature range: -40°C to +180°C
Layout drawing
External dimensions (W x D x H): approx. 1390 x 2380 x 1995 mm
Test chamber dimensions (W x D x H): approx. 1100 x 1475 x 950 mm
Weight: approx. 1020 kg / 1540 liters
Refrigerant: R 404A
For your safety as the buyer, please note the following information!
The following items are carried out on all chambers offered by us:
1. Functional inspection and replacement of necessary components
2. If needed, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Dsdpfx Asziyvusc Heci
Condition: used
Scope of delivery: (see photo)
(Technical data and information subject to change and errors excepted!)
We are happy to answer further questions by telephone.
Listing
Borken
18,513 km
Climate test chamber with humidity
VötschVC³ 0100 0°C bis + 90°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 0100
Vötsch Climate Test Chamber, Air-Cooled
Internal Test Chamber Dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall Device Dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Test Chamber Volume: 990 litres
Temperature Testing:
Minimum Temperature: -0°C
Maximum Temperature: +90°C
Temperature Change Rate, Cooling: 0.2 K/min
Temperature Change Rate, Heating: 0.5 K/min
Temporal Temperature Deviation: ±0.1 to ±0.5 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Heat Compensation at +20 °C: 350 W
Climatic Testing:
Minimum Temperature: +10°C
Maximum Temperature: +90°C
Dew Point Temperature Range: +4°C to +89.5°C
Humidity Range: 10 to 98% r.h.
Temporal Humidity Deviation: ±1 to ±3% r.h.
Temporal Temperature Deviation: ±0.1 to ±0.3 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Dcjdjziypuopfx Ac Hsi
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Refrigerant: R-404A
Weight: approx. 1400 kg
Important information for you as a buyer:
The following measures are carried out on our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and error!)
For further questions, we are happy to assist you by phone.
Listing
Borken
18,513 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Port openings: Ø 125 mm, Ø 50 mm
Temperature test specifications:
Temperature range: -42°C to +180°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Max. heat compensation at +20°C: 4500 watts
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1% to ± 3% r.h.
Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
For your security as a buyer, please note the following information!
The following points are checked and carried out on all our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. If needed, fresh filling with legally compliant refrigerant
3. Leak check with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
Dcjdpfx Aoziypnoc Hei
(Subject to prior sale, changes and errors in technical data and specifications reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
18,513 km
Testing of lithium-ion batteries
VötschVC³ 4018/S Li-Ion CO/CO
Call
Condition: excellent (used), Vötsch
Type: VC³ 4018/S
Vötsch VC³ 4018/S Climate Test Chamber – Li-Ion CO/CO₂
−42 to +150 °C 400 V Air-cooled
For sale is a temperature and climate test chamber from the renowned German manufacturer Vötsch Industrietechnik GmbH, model VC³ 4018/S, year of manufacture 2012. The unit is specifically equipped for testing lithium-ion batteries and features CO monitoring as well as CO₂ inertization for enhanced operational safety.
Important Note:
Due to these safety features, the test chamber is software-limited to a temperature range of −42 °C to +150 °C.
The chamber is ideally suited for:
Dcedpfx Acozimfvj Hji
- Li-Ion battery testing
- Electronics and assembly testing
- Temperature and climate stress tests
- Development and quality assurance tasks
Technical Data:
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
External dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Feed-throughs included as standard:
R1: Ø 125 mm
L1: Ø 50 mm
Data for temperature tests:
Temperature range: -42°C to +150°C
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating 4 K/min
Cooling 4 K/min
Max. heat compensation: 2300 W
Data for climate tests:
Temperature range: +10 to +95 °C
Dew point range: -3 to +94 °C
Humidity range: 10 to 98 % RH
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1 to ± 3 % RH
Heat compensation: 400 W
Operating data:
Test chamber lighting: Halogen bulb 2 x 24V, 50W
3/N/PE AC 400V ±10% 50 Hz
Rated power: 4.1 kW
Rated current: 14 A
Refrigerant: R-404A
Weight: 470 kg
Important Safety Information for Buyers!
The following servicing steps are performed on our offered chambers in advance:
1. Function check and replacement of necessary components
2. If required, new refill with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: Used
Scope of delivery: (See image)
(Specifications and technical data are subject to change and errors are excepted!)
If you have further questions, we are happy to assist you by phone.
Listing
Borken
18,513 km
-50°C to +220°C, -80 to +70°C, 60 liters
VötschVT³ 7006 S2 Temperaturschockschrank
Call
Condition: excellent (used), Vötsch
Type: VT³ 7006 S2-M
Water-cooled
Technical Specifications:
Maximum specimen weight: 20 kg
Test chamber volume: 60 liters
Test chamber internal dimensions: Width 380 mm, Depth 430 mm, Height 370 mm
External dimensions: Width 875 mm, Depth 1970 mm, Height 1895 mm
Vertical arrangement of hot and cold chambers (chamber change via lift carriage)
Temperature range of hot chamber: +50 °C to +220 °C (calibration value +125 °C)
Temperature range of cold chamber: -80 °C to +70 °C (calibration value -40 °C)
Uniform temperature distribution in the test chamber (±0.5 K to ±2.0 K)
Temporal temperature deviation: ±0.3 K to ±1.0 K
80 mm duct for measurement/supply connections to the specimen
SIMCONTROL software for operation and status display
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power: 8.5 kW
Rated current: 25 A
Refrigerants: R-404A, R-23
Weight: approx. 800 kg
Important information for your safety as a buyer!
The following points are carried out on the chambers we offer prior to sale:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if required
3. Leak test with certificate
4. Following successful inspection, the chambers undergo a documented test run.
Condition: used
Dedpjzima Hefx Ac Hsci
Scope of delivery: (see photo)
(Specifications and information subject to change or error!)
Should you have any further questions, we are happy to answer them by phone.
Listing
Borken
18,513 km
Drying cabinet / heating cabinet
Thermo Scientific VötschUT 6420 300 °C
Call
Condition: excellent (used), Thermo Scientific Vötsch
Type: UT 6420
For sale is a professional laboratory and industrial drying oven / heating cabinet, Thermo Scientific / Vötsch Industrietechnik – Type UT 6420.
This unit is suitable for drying, heating, tempering, and heat treating materials and components at precisely controlled temperatures up to 300 °C.
Typical areas of application include laboratory, industry, workshop, research, electronics, and materials testing.
The stainless steel chamber ensures uniform heat distribution and is designed for continuous operation.
Chamber: Stainless steel with insertion racks
External dimensions (approx.): 170 × 70 × 80 cm (H × W × D)
Technical specifications:
Manufacturer: Thermo Scientific / Vötsch Industrietechnik
Dcjdpfx Acezimate Hoi
Type: UT 6420
Max. temperature: 300 °C
Temperature control: Electronic (Heraeus Kelvitron)
Rated voltage: 3/N/PE 400 V, 50/60 Hz
Rated current: 6.6 A
Power consumption: approx. 4.2 kW
Protection class: IP20
Weight: approx. 200–230 kg
Condition: used
Scope of delivery: (see photo)
(Specifications are subject to change and errors; details are non-binding!)
For further questions, we are happy to assist you by phone.
Listing
Borken
18,513 km
Assemblies / Test cabinet
VötschVT 3050 -30°C / +100°C 500 Liter
Call
Condition: excellent (used), Vötsch
Type: VT 3050
Modules / Test Chamber Temperature Chamber
Air-cooled
Djdoziizaopfx Ac Hoci
Test chamber capacity 500 litres
Temperature range -30°C / +100°C
Temporal temperature fluctuation K ±0.5
Spatial temperature fluctuation K ±1.5
Temperature gradient K 3
Change rate
Heating K/min 2.0
Cooling K/min 1.4
Heat compensation max. W 650
Calibration values +23°C +80°C
Test chamber dimensions Width 710 mm Depth 590 mm Height 1250 mm
External dimensions Width 940 mm Depth 1030 mm Height 1955 mm
Sound pressure level db(A)
Listing
Borken
18,513 km
Temperature test chamber -70°C to +180°C
VötschVTS 7018-5 190 Liter
Call
Condition: excellent (used), Vötsch
Model: VTS 7018-5
Water-cooled Temperature Test Chamber
System retrofitted with R-452A
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Dcjdpfx Acsziixxo Hji
Temperature change rate cooling: 7.5 K/min
Temperature change rate heating: 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated power: 10.0 kW, Rated current: 21 A
Main fuse (on-site): 32 A slow-blow
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side port: 50 mm / 125 mm
Chamber is water-cooled
Refrigerants: R-452A and R 23
Weight approx. 460 kg
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, new charging with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Technical data may be subject to change or error!)
If you have any further questions, we will be happy to answer them by phone.
Listing
Borken
18,513 km
Temperature test chamber -70°C to +180°C
VötschVT 7021
Call
Condition: excellent (used), Heraeus Vötsch
Dodpfx Acsziiw Io Hjci
Type: VT 7021
Air-cooled temperature test chamber
1 port, nominal width 80 mm,
Test chamber volume: 210 liters
Temperature range: -70°C to +180°C
Temporal temperature deviation: ± 0.2 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (heating): 2.5 K/min
Temperature change rate (cooling): 2.5 K/min
Max. heat compensation: 800 W
Test chamber dimensions: Width 560 mm, Depth 570 mm, Height 630 mm
External dimensions: Width 850 mm, Depth 1250 mm, Height 1640 mm
Electrical connection: 1/NPE AC 230 V ± 10% 50 Hz
Rated power approx. 1.8 kW, rated current 12 A
Refrigerant: R404A and R23
Weight: 355 kg
For your safety as a buyer, please note the following information!
The following procedures are performed on the chambers we offer, in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Subject to technical modifications and errors in the details!)
For further questions, please feel free to contact us by phone.
Listing
Borken
18,513 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Dcodsziiwzspfx Ac Hsi
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.
Listing
Borken
18,513 km
Climatic test chamber temp. -70°C to +180°C
Vötsch 190 LiterVCS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VCS 7018-5
Climate testing chamber with humidity, water-cooled
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1775 mm
Specifications for temperature tests:
Temperature range: -70°C to +180°C
Temporal accuracy: ± 0.1 to ± 0.5 K
Spatial accuracy: ± 0.5 to ± 2.0 K
Temperature gradient: 1 to 4 K
Temperature change rate according to IEC 60068-3-5
Heating: 7.5 K/min
Cooling: 7.5 K/min
Specifications for climate tests:
Temperature range: +10 to +95°C
Humidity range: 10 to 98 % RH
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature deviation: ± 0.5 to ± 1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation: ± 1 to ± 3 % RH
Dew point range: -3 to +94 °C
Dcsdpfx Ajziiwhoc Hsi
Electrical connection:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated power: 10 kW
Rated current: 21 A
Fuse rating: 32 A slow-blow, on-site
Refrigerant: R-404A / R-23
Test chamber volume: approx. 190 liters
Weight: approx. 460 kg
For your safety as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
18,513 km
With moisture 270 liters
VötschKlimaprüfschrank VCS³ 7027-10
Call
Condition: excellent (used), Vötsch
Type: VCS³ 7027-10
Vötsch Climate Test Chamber, Water-Cooled
With a temperature change rate of 10 K/min
Data for temperature testing:
Temperature range: -72°C to +180°C
Temporal temperature deviation in the center of the usable space: ± 0.3 K to ± 0.5 K
Spatial temperature deviation: ± 0.5 K to ± 2.0 K
Temperature change rate:
Heating: 10 K/min
Cooling: 14.5 K/min
Data for climate testing:
Temperature range: +10°C to +95°C
(extended climate range: 2°C/95% relative humidity, regulated for max. 2 hours)
Temporal temperature deviation in the center of the usable space: ± 0.2 K to ± 0.3 K
Spatial temperature deviation: ± 0.5 K to ± 1.0 K
Temporal humidity deviation in the center of the usable space: ± 1% to ± 3% relative humidity
Humidity range: 10% to 98% relative humidity
(extended climate range: 2°C/95% relative humidity, regulated for max. 2 hours)
External dimensions: Width 780 x Depth 1895 x Height 1775 (mm)
Test chamber dimensions: Width 580 x Depth 615 x Height 750 (mm)
Test chamber volume: approx. 270 liters
Side opening: 50 mm
Side opening: 125 mm
Data for operation:
LED strip 24 V, 6.8 W / 2 x halogen bulb 24 V, 50 W
Nominal voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Nominal power: 14 kW Nominal current: 26 A
Fuse, on customer’s side: 63 A, slow-blow
Refrigerant: R404A/R-23
Weight: approx. 835 kg
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
Djdpfjzh Huujx Ac Hsci
We will gladly answer any further questions you may have over the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
18,513 km
Temperature test chamber spray device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in the stabilized state
according to IEC 60068-3-5, depending on the test chamber temperature
± 1 K over time
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the support grid
Water level = 0 mm
The water level is at the top edge of the support grid
Data for spray device, standard
Number of spray nozzles 6
Spray volume per nozzle 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles 6
Spray volume per nozzle 4.5 l/min
Additional flooding nozzles 2
Spray volume additional nozzle 6 l/min
Compressed air consumption approx. 3 m³/h
Data for water tank with preheating
Volume approx. 2000 l
Temperature range for preheating +5°C to +40°C
Temperature change duration
Cooling from +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Data for installation and operation:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Feedthroughs
1 feedthrough ∅ 50 mm, installed on the left
Test chamber volume: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Rated voltage 3/N/PE AC 400V ± 10% 50Hz
Rated power approx. 26 kW
Rated current approx. 44.0 A (neutral conductor loaded)
Fuse 63 A gG, on-site
Dcsdpfx Acezh D S Rs Hei
Weight approx. 890 kg net
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature range: -70°C to +180°C
Temperature deviation (temporal): ±0.1 to ±0.5 K
Temperature deviation (spatial): ±0.5 to ±2.0 K
Temperature change rate (cooling): 5.0 K/min
Temperature change rate (heating): 6.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test chamber volume: 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW, Rated current: 21 A
Sound pressure level at 1m distance (free-field measurement): < 69 dB (A)
Side feed-through: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R-404A and R-23
Weight: approx. 570 kg
Djdpfx Aszg Tyzsc Hsci
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
18,513 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climate test chamber
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Time-related temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4
Rate of change:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration values: +23°C and +80°C
Performance for climate tests:
Temperature range: +10 to +95°C
Time-related temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-related humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration values: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580mm, Depth 765mm, Height 750mm
External dimensions: Width 870mm, Depth 1595mm, Height 1775mm
Dcsdpfezg Tx Rox Ac Hoi
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R-404A / R-23
For your security as a buyer, please note the following:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions by telephone.
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Dcsdpszg Twgofx Ac Hsi
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make it easier for you to find: "vötsch vc7018"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month










































































































































































































































