Used Weiss Temperature Shock Test Chamber for sale (18,356)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
18,513 km
Temperature test chamber
CTST -70/600
Call
Condition: excellent (used), CTS Temperature Test Chamber
We are offering you a CTS temperature test chamber.
Water-cooled
CTS Temperature Test Chamber
Technical specifications:
Temperature operating range:
Temperature range: -70°C to +180°C
Cooling rate: 3.0 K/min
Heating rate: 3.5 K/min
Temperature stability, temporal: ≤± 0.3 K
Dimensions:
Test volume: 600 liters
Test chamber internal dimensions: Height approx. 850 mm, Width approx. 850 mm, Depth approx. 830 mm
External dimensions: Height approx. 1900 mm, Width approx. 1120 mm, Depth approx. 1875 mm
Operating data:
Electrical connection: 400 V +6% -10%, 3/N, 50 Hz
Connected load: 8.2 kW, 14.2 A
Refrigerant: R404A / R23
Weight: 600 kg
Model: T-70/600
Important Information for Buyers!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
Kljdpfxsygupfs Abfju
4. After successful inspection, the chambers undergo a test run monitored with calibrated equipment.
Condition: used
Scope of delivery: (see picture)
(Technical data, specifications, and information are subject to change and errors!)
If you have further questions, we are happy to answer them by phone.
Listing
Borken
18,513 km
Vibration temperature test chamber
RS-SimulatorenVTS 600/45 RS -45°C...+180°C
Call
Condition: excellent (used), We are offering a temperature test chamber here.
Water-cooled
Temperature range: -45°C to +180°C
External dimensions: Width 1300 mm x Height 2100 mm x Depth 2250 mm
Test chamber dimensions: Width 840 mm x Height 840 mm x Depth 840 mm
Unit section: Width 2300 mm x Height 2000 mm x Depth 1300 mm
Average heating rate: approx. 3 K/min
Average cooling rate: approx. 2 K/min
Power consumption: 15 A
Connection voltage: 3x400V/N/PE 50Hz
Klodpeygunhsfx Abfsu
Weight: approx. 1000 kg
Type: VTS 600/45 RS
Refrigerant: R452
Condition: used
Scope of delivery: (see picture)
(Specifications are subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Borken
18,513 km
Temperature test chamber
FeutronTPK 200 Typ: 3416/17
Call
Condition: excellent (used), Feutron Temperature Test Chamber
We are offering a temperature test chamber here.
Feutron Temperature Test Chamber, Air-Cooled
Nominal test chamber volume: 280 liters
Dimensions
External dimensions: 1500 x 2040 x 1075 mm
With fan motor and door removed: 1500 x 1940 x 925 mm
Test chamber interior: 720 x 690 x 560 mm
Door, clear opening: 720 x 690 mm
Heated viewing window: 500 x 600 mm
Temperature range
-70°C to +180°C
Heating rate: 4.0 K /min
Cooling rate: 0.6 K /min
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Maximum power consumption: 6.3 kW
Weight: 600 kg
Type: 3416/17
Refrigerants: R507 / R23
For your safety as a buyer, please note the following information!
The following steps are carried out on all chambers we offer in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
Ksdpfx Ajygulyebfelu
3. After successful inspection, the chambers undergo a test run monitored with calibrated equipment.
Condition: used
Scope of delivery: (See photo)
(Specifications subject to change and errors excepted!)
If you have any further questions, we are happy to answer them by phone.
Listing
Borken
18,513 km
Temperature test chamber 600 liters
CTST-70/600 -70°C bis 180°C
Call
Condition: excellent (used), CTS Climate Test Chamber T-70/600 Water-Cooled
Temperature Range: -70°C to +180°C
Rated Voltage: 400V 3/N PE 50 Hz
Rated Power: 6.7 kW
Rated Current: 10.2 A
Compressor: TFH2480Z/TFH2511Z, Refrigerant R23/R404A
Control System:
- Microprocessor-controlled regulation and monitoring system
- Simple, user-friendly terminal integrated into the door
- Digital display for set and actual temperature values
- Easy adjustment via +/- keys
- Digital input for temperature in °C
- PLC-compatible
- Up to 100 test programs possible
- RS 232 interface
- 2 free switching channels for user-side test specimen connections
Shelving:
Stainless steel, shelf area 820 x 710 mm
Load capacity per shelf max. 35 kg
Klodpfx Aboygultjfou
Total load capacity with full shelf configuration 100 kg
Cooling Unit:
Water-cooled, low-noise, fully hermetic, stepless power adjustment via electronic monitoring and control system,
environmentally friendly refrigerants R404A/R23
Temperature Testing:
Temperature range -70°C to +180°C
Temperature deviation ±0.1 to 10.3 K over time
Temperature change rate according to DIN 50 011, Part 12 measured at the center of the test chamber:
Heating: 2.5 K/min
Cooling: 2 K/min
Thermal radiation max. 1500 W at +20°C
Technical data refer to an ambient temperature of +25°C, rated voltage 400 V, without test specimen, without thermal radiation, and without additional equipment.
Dimensions:
Test volume 600 liters
Test chamber dimensions 850 x 830 x 850 mm (W x D x H)
External dimensions 1050 x 1850 x 1900 mm (W x D x H)
Operating Data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 6.7 kW
Rated current 10.2 A
Protection class IP 22
Condensate drain non-pressurized, R 1/2" internal thread
Sound pressure level < 62 dB(A)
Weight approx. 400 kg
For your safety as a buyer, please note the following information!
The following steps are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information reserved!)
Further questions can be answered by phone.
Listing
Borken
18,513 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), We are offering a Weiss temperature test chamber for sale.
Kljdpfx Ajyguh Ijbfju
Weiss Temperature Test Chamber with S!MCON / 32-controller, water-cooled
Control Unit: "Touchpanel"
All control and operation commands can be initiated by simply touching the function symbols on the "Touchpanel" control unit.
Adjustable Feet
The test chamber is equipped with adjustable feet to compensate for floor unevenness and to provide adequate ventilation for the machine section.
Cable Ports
Cable ports are installed on both the right and left sides of the test chamber. These allow measurement cables and test devices to be routed into the test space. Ports included as standard:
- R1: NW 125 mm
- L1: NW 50 mm
(The refrigerant has been converted to R-452A)
Test Chamber Volume: approx. 600 liters
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Temperature Test Data:
Temperature range: -42 to +180 °C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
Maximum thermal compensation: 2500 W
Operating Data:
- Test chamber lighting: Halogen bulb 2 x 24V, 50W
- Rated voltage: 3/N/PE AC 400V ±10% 50Hz
- Rated current: 15 A; Rated power: 7.8 kW
- Fuse (on-site): 16 A slow-blow
- Sound pressure level: approx. 58 dB(A) (measured 1 m in front, 1 m height)
- Refrigerant: R-452A
- Weight: 620 kg
Type: WT3-600/40
Important information for your safety as a buyer!
The following steps are carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. Refill with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
18,513 km
Temperature test chamber
VötschVTR 7033/S
Call
Condition: good (used), Year of construction: 1996, Vötsch VTR 7033/S Temperature test chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item no.: 60885637
Temperature chamber
Temp. range: -70°C to +180°C
Mains voltage:400V
Rated current:24A
Rated output: 9.5 kW
Refrigerant VK: R 404 A
Kljdpjwbpzmofx Abfeu
Refrigerant TK: R 23
Year of manufacture: 1996
TK 07
Financing through our bank is also possible.
komplett-konzept.leasingo.de
You will find further articles - new and used - in our store!
International shipping costs on request!
Listing
Borken
18,513 km
Temperature shock chamber
NemaNCG 4390 S
Call
Condition: good (used), Year of construction: 1999, Nema NCG 4390 S Temperature shock chamber -40°C to +180°C
Manufacturer: Nema
Type: NCG 4390 S
Temp. range: -40°C to +180°C
Dew point range: +5 °C to +89 °C
Mains voltage: 400 V
Rated current: 32 A
Nominal output: 15 kW
Refrigerant: R 404 A
Year of construction: 1999
Weight: 2720 kg
External dimensions: W 3950 x D 1700 x H 2280 mm
Chamber: W 3000 x D 1300 x H 1170 mm
WLG STEAM-O-MAT
Electric automatic steam humidifier and producer of mineral-free and odorless steam
Manufacturer: WLG
STEAM-O-MAT
Type: EDB 8
Heating voltage: 400 V
Output: 6 kW
Steam quantity: 8 kg/h
Water-cooled condenser
Manufacturer: Bitzer
Water-cooled
Mains voltage: 400 V
Rated current: 13 A
Nominal capacity: 4 kW
Refrigerant: R 404 A
Weight: 145 kg
Kedpfx Abouzgt Esfolu
KK-08
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further articles - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
18,513 km
Temperature test chamber
VötschVT 7100
Call
Condition: excellent (used), Heraeus Vötsch VT 7100 Temperature test chamber -70°C to +180°C
Heraeus Vötsch
Temperature test chamber
VT 7100
-70°C to +180°C
1035 liters
Kljdoph Uzxopfx Abfsu
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further articles - new and used - you will find in our store!
International shipping costs on request!
Listing
Borken
18,513 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1998, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Ksdpfeuuin Rex Abfolu
Year of Manufacture: 1998
TK 09
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVCS 7100
Call
Condition: good (used), Vötsch VCS 7100 Climatic Test Chamber -70°C to +180°C
Manufacturer: Vötsch
Type: VCS 7100
Temp. Range: -70°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Rated Power: 11 kW
Refrigerant: R404A
Height: 1980 mm
Width: 1350 mm
Depth: 2060 mm
Chamber:
Kledpjuuix Nsfx Abfeu
Height: 900 mm
Width: 970 mm
Depth: 1400 mm
KK-05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
Andreas SchmidVKT 3.000 /-40/+130
Call
Condition: good (used), Year of construction: 2005, Andreas Schmid Climatic Test Chamber -40°C to +130°C
Manufacturer: Andreas Schmid
Type: VKT 3.000 /-40/+130
Temp. Range: -40°C to +130°C
Program Controller: Stange SE - 502
Line Voltage: 400 V
Rated Current: 32 A
Refrigerant: R 404 A / R 23
Year of Manufacture: 2005
Ksdpfx Abjuuibkofjlu
External Dimensions: W 1600 x D 800 x H 2430 mm
TK-16
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
18,513 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1997, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Kedpfx Absuuiv Iefolu
Refrigerant (TK): R 23
Year of Manufacture: 1997
TK 08
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVCS 4100
Call
Condition: good (used), Vötsch VCS 4100 Climatic Test Chamber -40°C to +180°C
Manufacturer: Vötsch
Type: VCS 4100
Temp. Range: -40°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Kodpfx Aeuuiygsbfelu
Rated Power: 11 kW
Refrigerant: R404A
KK-07
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
Heraeus VötschHC 4055
Call
Condition: good (used), Heraeus Vötsch HC 4055 Temperature Test Chamber
Manufacturer: Heraeus Vötsch
Type: HC 44055
Temperature Chamber
Temperature Range: +180°C
Rated Voltage: 380V, +-10%, 3/N, 50Hz
Rated Current: 13.5 A
Rated Power: 9 kW
Housing Dimensions: W 1065 x D 1560 x H 1890 (mm)
Observation Window: Width x Height 350 x 640 mm
Test Chamber: (L x D x H) approx. 800 x 795 x 855 mm
Test Chamber Volume: 550 l
Cabinet is air-cooled
Caution
Cabinet can only be operated as an oven.
Refrigeration circuit empty and shut down.
Air conditioning system shut down.
Disconnected contactors:
03K2 Compressor
Klodpjuuilvefx Abfeu
03K5 Condenser fan
15K6 Panel heater
Solid state relay 21V4 Humidifier.
Weight approx. 550 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
More items - new and used - can be found in our shop!
International shipping costs on request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVTSR 7034/S
Call
Year of construction: 2002, condition: good (used), Vötsch VTSR 7034/S Climatic Test Chamber -70 to +180°C
Manufacturer: Vötsch
Type: VTSR 7034/S
Test Chamber Capacity: 335 liters
Climatic Test Chamber
Temp. Range: -70 to +180°C
Line Voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated Current: 22 A
Rated Power: 12.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Year of Manufacture: 2002
TK-11
Kedpsuuif Njfx Abfelu
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVC 0150
Call
Condition: excellent (used), Vötsch VC 0150 Climatic Test Chamber 0°C - +90°C
Manufacturer: Vötsch
Type: VC 0150
Climatic Test Chamber
Voltage: 230 V
Rated Power: 1.5 kW
Voltage: 1540 liters
Temperature Range: 0°C to +90°C
Humidity: 10% to 98%
Refrigerant: R 134a
Kledpjuuikfsfx Abfou
Dimensions: W 950 x D 1100 x H 1475 mm
Microprocessor Controller
List Price: €19,500
KK-09
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Ksdpeu H U Twsfx Abfelu
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Shock test chamber –80 °C to +220 °C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Shock Test Chamber, Air-cooled
Two-chamber design
Hot Chamber:
The temperature range of the hot chamber extends from +50°C to +220°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Kjdpfswxc I Usx Abfslu
Temperature change rate
Heating: 11 K/min
Cold Chamber:
The cold chamber temperature range is from -80°C to +70°C
Temporal temperature deviation at the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Hot chamber temperature range: +50°C to +220°C
Cold chamber temperature range: -80°C to +70°C
Test chamber dimensions: Width 470 mm, Depth 650 mm, Height 410 mm
External dimensions: Width 930 mm, Depth 2115 mm, Height 1970+ mm
Port diameter: ∅ 67 mm
Voltage: 3/N/PE AC 400V +10% 50 Hz
Nominal power: 10 kW
Nominal current: 25 A
Refrigerants: R452-A / R23
Weight: 1,000 kg
Important information for your safety as a buyer!
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and correction!)
For further questions, please feel free to contact us by phone.
Listing
Borken
18,513 km
Temperature test chamber 600 liters
CTST-40/600 -40...180°C
Call
Condition: excellent (used), CTS
Type: T-40/600 /011232
CTS Temperature Test Chamber, Water-Cooled
Includes metal struts to increase the floor load-bearing capacity
Test chamber volume: 600 liters
Test chamber dimensions:
Height approx. 850 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions:
Height approx. 1900 mm, width approx. 1050 mm, depth approx. 1850 mm
Temperature operating range:
Temperature range -40 to +180°C
Temperature deviation ±0.1 to ±0.3 K over time
Heating rate: 2.5 K/min
Cooling rate: 3 K/min
Electrical connection: 400 V +6% -10%, 3/N, 50 Hz
Rated power: approx. 5.5 kW
Rated current: approx. 8.5 A
Refrigerant: R-404A
Kedpswfdnisfx Abfelu
Weight: 550 kg
For your safety, please note the following information!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Air-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Kjdpfx Asrak S Dobfslu
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions: Height 950 mm, width 800 mm, depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 2500 W
Data for operation:
Test room lighting Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A Rated power 7.8 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front. 1m height 61 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
Kjdjun Izcepfx Abfolu
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
18,513 km
Shock test chamber –75°C to +220°C
VötschVT 7012 S2
Call
Condition: excellent (used), Vötsch
Model: VT 7012 S2
Water-cooled
Two-chamber configuration
Hot chamber:
Temperature range of hot chamber: +50°C to +220°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Kodpfx Aox Hhfhebfelu
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Temperature range of cold chamber: -74.5°C to +70°C
Temporal temperature deviation at the center of useful space: ±1 K
Spatial temperature deviation: ±2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range hot chamber: +50°C to +220°C
Temperature range cold chamber: -80°C to +70°C
Test chamber dimensions: width 470 mm, depth 650 mm, height 410 mm
External dimensions: width 930 mm, depth 2115 mm, height 1970+ mm
Port diameter: 67 mm
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Rated power: 10 kW
Rated current: 25 A
Refrigerants: R-452A / R-23
Weight: 1000 kg
Important safety information for buyers:
The following actions are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Recharging with legally compliant refrigerant
3. Leak test with certificate
4. After a successful check, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in technical data and specifications!)
We are happy to answer further questions by phone.
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Klodpfx Abjun Rulsfju
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber
CTSTSR-30/1000
Call
Condition: good (used), CTS
Type: TSR-30/1000
Kledpfxsrivfco Abfju
Water-cooled
The type designation of the CTS enclosure series is made up as follows:
z. e.g. type TSR -30/1000
1) T means: Temperature
2) S means: stress screening
3) R means: external conditioning
4) -30 means: lower temperature -30 °C
5) 1000 means: 1000 liter test chamber volume
Technical performance data:
A) TSR-30/1000 basic device without hose connections,
i.e. when used as a stand-alone temperature test chamber
Temperature tests:
Temperature range -40°C to +180°C
Final temperature -45°C
Temperature deviation ≤ ±0.3 K in time
Temperature change rate according to IEC 60068-3-5
Heating 6.0 K/min
Cooling 5.0 K/min
Heat radiation
approx. 5000 W at +20°C
approx. 4200 W at ± 0°C
approx. 3000 W at -20°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment.
Air volume flow
approx.2000m³/h
B) TSR-30/1000 basic unit with hose connections,
for connection to an external test room provided by the customer
Temperature tests:
Temperature range -30°C to +170°C
Temperature deviation ≤ ±0.1 to 0.5 K in time
Average rate of temperature change,
measured with short-circuited circuit
Heating 4.0 K/min
Cooling 4.0 K/min
in the range from +150°C to -10°C
The technical data refer to an ambient temperature of +25 °C,
rated voltage 400V, without test material, without irradiation and without additional equipment,
measured with short-circuited circuit
Attention: The external test chamber provided by the customer must be absolutely tight and appropriately insulated,
any feed-throughs must be optimally sealed on site.
Dimensions:
Test volume 1000 liters
Air circulation connection Ø 200 mm
Test chamber dimensions Height 900 mm Width 1000 mm Depth 1100 mm
External dimensions Height 1950 mm Width 1270 mm Depth 2245 mm
Technical design:
Refrigeration unit:
water-cooled, low-noise, fully hermetic
Infinitely variable capacity adjustment through
electronic monitoring and control system,
environmentally friendly refrigerant R404A
Door:
Fully opening door, door hinge on the left,
one-handed operation, lockable.
Shelf:
Stainless steel, support surface 970 x 980 mm
Max. load per shelf 35 kg
Total load with max. shelf load 100 kg
Test area lighting: Halogen lamp 20 W, 12 V
Control:
- 32 bit controller
- LCD control panel
Operating data:
Electrical connection 400 V +6/-10 %, 3/N, 50 Hz
Rated power 13.3 kW
Protection class IP 22
Sound pressure level < 60 dB(A)
Weight approx. 850 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature shock test system
RS-SimulatorenST2K320/45
Call
Condition: excellent (used), RS Simulators
Type: ST2K320/45
Water-cooled shock test system
Working climate area
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Temperature: +12 °C to +30 °C
Humidity: 25% to 75% relative humidity
Dimensions Width 1100 mm Height 2300 mm Depth 2300 mm
Test chamber dimensions: Width 470 mm Depth 700 mm Height 440 mm
Electrical power supply:
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 850 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
Klodpfstqcu Eex Abfju
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make it easier for you to find: "weiss temperature shock test chamber"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you