Thermal shock test chamberRS-Simulatoren
ST2K320/45 K
Thermal shock test chamber
RS-Simulatoren
ST2K320/45 K
Condition
Used
Location
Borken 

Machine data
- Machine type:
- Thermal shock test chamber
- Manufacturer:
- RS-Simulatoren
- Model:
- ST2K320/45 K
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A22185487
- Reference number:
- 24112
- Update:
- 23.06.2026
Description
RS Simulators
Type: ST2K320/45 K
Shock test system, water-cooled
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Humidity levels in the upper test chamber
Climate temperature range: +40 °C to +90 °C
Humidity range: 20% to 98% (± 2 to 5%) relative humidity
Humidity: 25% to 75% relative humidity
Operating climate range:
Temperature: +12 °C to +30 °C
Lodpfezgbutex Aiiehh
Humidity: 25% to 75% relative humidity
Dimensions: Width 900 mm, Height 2000 mm, Depth 2300 mm
Test chamber dimensions: Width 470 mm, Depth 700 mm, Height 440 mm
Electrical power supply:
Total power: 13 kVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
The listing was translated automatically. Translation errors are possible.
Type: ST2K320/45 K
Shock test system, water-cooled
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Humidity levels in the upper test chamber
Climate temperature range: +40 °C to +90 °C
Humidity range: 20% to 98% (± 2 to 5%) relative humidity
Humidity: 25% to 75% relative humidity
Operating climate range:
Temperature: +12 °C to +30 °C
Lodpfezgbutex Aiiehh
Humidity: 25% to 75% relative humidity
Dimensions: Width 900 mm, Height 2000 mm, Depth 2300 mm
Test chamber dimensions: Width 470 mm, Depth 700 mm, Height 440 mm
Electrical power supply:
Total power: 13 kVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Borken
18,513 km
Temperature shock test chamber
RS-SimulatorenST2K320/45
RS-SimulatorenST2K320/45
Listing
Wesel
18,545 km
Vibratory finishing machine
ERBAYE 60 Separierstrecke
ERBAYE 60 Separierstrecke
Listing
Mandres-la-Côte
18,888 km
Circular dryer
ROSLER PARKER ROTOFINISHS 20
ROSLER PARKER ROTOFINISHS 20
Your listing has been deleted successfully
An error has occurred