Used Cts Temperature Test Chamber Ex Protected for sale (30,265)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
18,513 km
Temperature shock test chamber
VötschVT 7030 S2
Call
Condition: good (used), Year of construction: 1998, Vötsch VT 7030 S2 Temperature Shock Test Chamber -80 °C to +220 °C
The Vötsch VT 7030 S2 Environmental Test Chamber is designed for laboratory applications that require testing of materials and components in a known environment. With its versatile capabilities and easy-to-use controls, this programmable unit can be used to simulate a variety of environmental conditions for scientific studies, product testing and process control.
Data for temperature tests in single chamber operation
Hot chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range +50 °C to +220 °C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation in space ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 11 K/min
Cold chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range -80 °C to +70 °C
Temperature deviation in time in the middle of the usable space ± 1 K
Temperature deviation in space 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 1.5 K/min
Cooling 4K/min
Itedpfx Aswbdv Sskxef
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10 % , 50 Hz
Rated power: 30 kW
Rated power: 50 A
Refrigerant: R-404a /R-23
Chiller: Water-cooled
Weight: approx. 940 kg
Year of construction. 1998
Test room dimensions: Width 770 mm x depth 650 mm x height 610 mm
Housing dimensions: Width 1200 mm x depth 1800 mm x height 2050 mm
TS 05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
18,513 km
Temperature test chamber
VötschVT 7100
Call
Condition: excellent (used), Heraeus Vötsch VT 7100 Temperature test chamber -70°C to +180°C
Heraeus Vötsch
Temperature test chamber
Itedpfxsph Uzxo Akxef
VT 7100
-70°C to +180°C
1035 liters
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further articles - new and used - you will find in our store!
International shipping costs on request!
Listing
Borken
18,513 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1998, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Isdpfxsuuin Rs Akxotf
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Year of Manufacture: 1998
TK 09
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVCS 7100
Call
Condition: good (used), Vötsch VCS 7100 Climatic Test Chamber -70°C to +180°C
Manufacturer: Vötsch
Type: VCS 7100
Temp. Range: -70°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Rated Power: 11 kW
Refrigerant: R404A
Isdpfsuuix Nsx Akxotf
Height: 1980 mm
Width: 1350 mm
Depth: 2060 mm
Chamber:
Height: 900 mm
Width: 970 mm
Depth: 1400 mm
KK-05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
Andreas SchmidVKT 3.000 /-40/+130
Call
Condition: good (used), Year of construction: 2005, Andreas Schmid Climatic Test Chamber -40°C to +130°C
Itsdpfx Aeuuibkjkxjf
Manufacturer: Andreas Schmid
Type: VKT 3.000 /-40/+130
Temp. Range: -40°C to +130°C
Program Controller: Stange SE - 502
Line Voltage: 400 V
Rated Current: 32 A
Refrigerant: R 404 A / R 23
Year of Manufacture: 2005
External Dimensions: W 1600 x D 800 x H 2430 mm
TK-16
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
18,513 km
Temperature shock test chamber -70-220°C
VötschVT 7012 S2
Call
Year of construction: 2000, operating hours: 104,382 h, condition: excellent (used), Vötsch Shock Test Chamber VT 7012 S2
System for extreme temperature cycling
Temperature shock testing is used to test the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclical stresses and the accelerated aging caused by temperature changes reveal weaknesses in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the car
Cart load capacity 50 kg for VT3 7012 S2
All-around grilles in the car secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
Hot chamber can be used as a temperature storage unit, cold chamber as a temperature exchange unit
Minimal energy consumption
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
Cooling unit: Water-cooled
Shock cooling (nitrogen cooling) via customer-supplied nitrogen
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class
Device: IP 42
Operating panel: IP 20
Control cabinet: IP 54
Temperature test parameters for single-chamber operation |
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class ...Temperatur Temperature range
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K
in steady state
Temperature deviation over space: ±2 K
in steady state in the car
Heating rate, hot chamber: 11 K/min
Cooling rate, cold chamber: K/min
Heating rate, cold chamber: 2 K/min
Cooling rate, hot chamber: K/min
Observation window: 355 x 355 mm
Pipe opening: 67 mm
Year of manufacture: 2000
Operating hours: 104,382
Weight: 1000 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Iodpfx Akex Exmtjxetf
Further items – new and used – can be found in our shop! International shipping costs on request!
Listing
Borken
18,513 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1997, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Year of Manufacture: 1997
TK 08
Itsdjuuiv Iopfx Akxsf
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVCS 4100
Call
Condition: good (used), Vötsch VCS 4100 Climatic Test Chamber -40°C to +180°C
Manufacturer: Vötsch
Type: VCS 4100
Temp. Range: -40°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Rated Power: 11 kW
Refrigerant: R404A
Itodpfjuuiygsx Akxjf
KK-07
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
Heraeus VötschHC 4055
Call
Condition: good (used), Heraeus Vötsch HC 4055 Temperature Test Chamber
Manufacturer: Heraeus Vötsch
Type: HC 44055
Temperature Chamber
Temperature Range: +180°C
Rated Voltage: 380V, +-10%, 3/N, 50Hz
Rated Current: 13.5 A
Rated Power: 9 kW
Housing Dimensions: W 1065 x D 1560 x H 1890 (mm)
Observation Window: Width x Height 350 x 640 mm
Test Chamber: (L x D x H) approx. 800 x 795 x 855 mm
Test Chamber Volume: 550 l
Cabinet is air-cooled
Caution
Cabinet can only be operated as an oven.
Refrigeration circuit empty and shut down.
Air conditioning system shut down.
Itjdpfxjuuilvo Akxjf
Disconnected contactors:
03K2 Compressor
03K5 Condenser fan
15K6 Panel heater
Solid state relay 21V4 Humidifier.
Weight approx. 550 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
More items - new and used - can be found in our shop!
International shipping costs on request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVTSR 7034/S
Call
Year of construction: 2002, condition: good (used), Vötsch VTSR 7034/S Climatic Test Chamber -70 to +180°C
Manufacturer: Vötsch
Type: VTSR 7034/S
Test Chamber Capacity: 335 liters
Climatic Test Chamber
Temp. Range: -70 to +180°C
Line Voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated Current: 22 A
Itjdpfxouuif Ne Akxjf
Rated Power: 12.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Year of Manufacture: 2002
TK-11
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
18,513 km
Temperature shock chamber climate test
NemaNTS 3000 / 2S
Call
Year of construction: 2000, condition: good (used), Nema Temperature Shock Test Chamber -40°C to +120°C
Manufacturer: Nema
Type: NTS 3000 / 2S
Temp. Range: -40°C to +120°C
Line Voltage: 400 V
Itodpfx Ajuuiayekxsf
Rated Current: 88 A
Rated Power: 55 kW
Refrigerant: R 404 A
Year of Manufacture: 2000
Weight: 5000 kg
External Dimensions: W 4000 x D 2760 x H 3450 mm
Chamber: W 3000 x D 1250 x H 1610 mm
TS-06
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Temperature test chamber 600 liters
CTST-40/600 -40...180°C
Call
Condition: excellent (used), CTS
Type: T-40/600 /011232
CTS Temperature Test Chamber, Water-Cooled
Includes metal struts to increase the floor load-bearing capacity
Test chamber volume: 600 liters
Test chamber dimensions:
Height approx. 850 mm, width approx. 850 mm, depth approx. 830 mm
External dimensions:
Height approx. 1900 mm, width approx. 1050 mm, depth approx. 1850 mm
Temperature operating range:
Temperature range -40 to +180°C
Temperature deviation ±0.1 to ±0.3 K over time
Heating rate: 2.5 K/min
Cooling rate: 3 K/min
Electrical connection: 400 V +6% -10%, 3/N, 50 Hz
Rated power: approx. 5.5 kW
Rated current: approx. 8.5 A
Iedpfx Akswfdnioxetf
Refrigerant: R-404A
Weight: 550 kg
For your safety, please note the following information!
The following steps are performed on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Isdpfxju H U Twe Akxjtf
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Type: VCS 7034-5
Climate Test Chamber Water-Cooled
Test chamber volume: 335 liters
Performance for temperature tests:
Temperature range: -70 to +180°C
Temperature deviation over time: ±0.1 to ±0.5 K
Temperature deviation spatially: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 3.5 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3,000 W / at -20°C: 3,000 W
Temperature calibration points: +23°C and +80°C
Performance for climate tests:
Temperature range: +10 to +95°C
Temperature deviation over time: ±0.1 to ±0.3 K
Temperature deviation spatially: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Humidity deviation over time: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climatic calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions:
Width: 580 mm, Depth: 765 mm, Height: 750 mm
External dimensions:
Width: 870 mm, Depth: 1595 mm, Height: 1775 mm
Feedthroughs:
1 x approx. 50 mm Ø, left side
2 x approx. 125 mm Ø, left side
1 x approx. 125 mm Ø, right side
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Iodpfx Akexufypexotf
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerant: R404A / R-23
For your security as a buyer, please note the following information:
The following points are performed on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and errors!)
If you have further questions, we are happy to answer them by phone.
Listing
Borken
18,513 km
Temperature test chamber
RS-SimulatorenTS 600/45 EX
Call
Condition: excellent (used), RS Simulators
Here we offer a test cabinet.
Water cooled
Temperature range: -40°C to +180°C
Test chamber dimensions: 850mm x 850mm x 800mm (WxHxD)
Outer dimensions: 1100mm x 1850mm x 1500mm (WxHxD)
current consumption: 13,5 A
Refrigerant: R404A
Connection voltage: 3x400V/N/PE 9A
Weight: approx. 750kg
Type: TS 600/45
Explosion proof operation not tested
but Max 160°C in this
Iedpfxjg Urq Ie Akxstf
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in technical data, specifications are reserved!)
Further questions we can answer gladly on the phone for you.
Listing
Borken
18,513 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), White temperature shock test chamber
Here we offer a temperature shock test chamber.
Weiss temperature shock test chamber air cooled
( Compressor was renewed ! )
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot-/cold chamber 10 s
Temperature constancy ±1 K
Isdpfx Akek E Htyoxjtf
Dimensions and further data:
External dimensions: Height 1990 mm
Width ( without and with swivel arm ) without....ca. 1820 mm with....ca. 1915 mm
Depth ( without and with test chamber door ) without....approx. 900 mm with....approx. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Itsdpfeun Izcox Akxjf
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature chamber.
Weiss temperature test chamber With S!MCON / 32 control Air-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered on the "touch panel" control unit by simply touching the function icons.
all control and operating commands by simply touching the function icons.
Levelling feet
To compensate for uneven floors and to ensure adequate ventilation of the machine part,
the test chamber is equipped with adjustable feet.
Feed-throughs
The test chamber is equipped with feed-throughs on the right and left side.
Measuring cables and test equipment can be routed through these into the test chamber.
Feed-through built into basic equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber capacity: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions: Height 950 mm, width 800 mm, depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 2500 W
Data for operation:
Test room lighting Halogen bulb 2 x 24V, 50W
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A Rated power 7.8 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front. 1m height 61 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Itedpfjrak S Dox Akxjf
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Itsdpfx Aoun Ruljkxef
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber
RS-SimulatorenTS 150/75
Call
Condition: excellent (used), RS simulators
Here we offer a temperature test cabinet.
Temperature test chamber water cooled
Temperature range: -70°C to +180°C
Time deviation: ±1 K according to DIN 50011 with empty test chamber
Average heating time: approx. 3 K/min 8acc. to DIN 50011 part 12)
Average cooling time: approx. 3 K/min 8acc. to DIN 50011 Part 12)
Test chamber dimensions: Width 530 mm x height 530 mm x depth 530 mm
Outer dimensions: Width approx. 900 mm x Height approx. 1800 mm x Depth approx. 1400 mm
Total power: approx. 6 kVA
power consumption: 12 A
Isdjlp Hytjpfx Akxetf
Main fuse: 3 x16 A, slow blow
Connection voltage: 3x400V/N/PE 50Hz
Weight: approx. 600 kg
Type: TS 150/75
Refrigerant: R404A / R23
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Temperature test chamber
Heraeus VötschVTS 7033
Call
Condition: excellent (used), Heraeus Vötsch temperature test chamber
Here we offer you a Heraeus Vötsch temperature test chamber.
Vötsch temperature test chamber VTS 7033 water cooled
Temperature range: -70°C to +180°C
Temperature deviation temporal ± 0,5 K
Temperature deviation temporal ± 1,5 K
Heating speed: 7,5 K/min
Cooling rate: 6.5 K/min
Test chamber dimensions: Width 825 mm x depth 800 mm x height 870 mm
housing dimensions: 1080 mm x 1710 mm x 1950 mm
lateral passage 12cm and 13cm
voltage: 400V+6/-10%,3/N, 50Hz
nominal power 9,5 kW nominal current 22 A
refrigerant R404A / R23
approx. 570 liters weight: 580 kg
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
Ijdslt U Avspfx Akxstf
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored by calibrated equipment.
Type: VTS 7033
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
18,513 km
Temperature test chamber
VötschVTS³ 7018-5
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7018-5
Water-cooled
Test chamber dimensions: Width 580 mm x depth 450 mm x height 750 mm
Housing dimensions: Width 900 mm x depth 1550 mm x height 1850 mm
Temperature test:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: cooling 7.5 K/min
Test chamber volume: 190 liters
Nominal voltage: 400V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
Isdpfxen E Sk Ee Akxotf
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber
WEISSWT1-600/70
Call
Condition: excellent (used), Weiss temperature test chamber
Here we offer a Weiss temperature test chamber.
Weiss temperature test chamber water cooled
Technical data:
Test chamber designation: WT1-600/70
Outer dimensions without hinges and door lock
height 1980 mm, width 1085 mm, depth 1655 mm
Internal dimensions
height 950mm, width 800mm, depth 800mm
Test chamber capacity: approx. 600 liters
cold / heat operation -70 to 180°C
Isdpfxoirmg As Akxjtf
Temperature change per time
cooling approx. 2,5 K/min
Heating up approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Permissible test material weight
Total load of grate supports 80kg
Refrigerant: R 404A +R23
Weight: 600kg
Type: WT1-600/70
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Temperature test chamber spraying device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in steady state
according to IEC 60068-3-5 dependent on the test chamber temperature
over time ± 1 K
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the insert grid
Water level = 0 mm
The water level is at the top edge of the insert grid
Data for standard spray device
Number of spray nozzles: 6
Spray volume per nozzle: 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles: 6
Spray volume per nozzle: 4.5 l/min
Additional flooding nozzles: 2
Spray volume of additional nozzle: 6 l/min
Compressed air consumption: approx. 3 m³/h
Data for water tank with pre-temperature control
Volume: approx. 2000 l
Temperature range for pre-temperature control +5°C to +40°C
Temperature change duration
Cooling of +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Installation and Operation Data:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Plug-ins
Itsdpfx Aswc Nvgekxsf
1 50 mm diameter plug installed on the left
Test chamber capacity: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Nominal voltage 3/N/PE AC 400V ± 10% 50Hz
Nominal power approx. 26 kW
Nominal current approx. 44.0 A (neutral conductor loaded)
Fuse protection 63 A gG, on-site
Weight approx. 890 kg net
For your safety, please note the following information!
The following steps are carried out on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Itsdpjun Rv Nofx Akxef
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
We make it easier for you to find: "cts temperature test chamber ex protected"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month