English
German German German English English French French Spanish Spanish Italian Polish Russian Belarusian Dutch Ukrainian Estonian Turkish English English English Czech Danish Finnish Swedish Norwegian Bokmål Maltese Luxembourgish Greek Lithuanian Latvian Kazakh Icelandic Portuguese Portuguese Spanish Spanish Hungarian Slovak Romanian Romanian Slovenian Serbian Serbian Albanian Croatian Bulgarian Macedonian Bosnian Hebrew Arabic Hindi English Indonesian Korean Japanese Thai Malay Vietnamese Chinese Chinese Persian Bengali Pashto Urdu

Steam turbines for sale

Your location was not identified (Edit)
710 KWel back pressure Siemens SST-060 (AFA4 G3a) steam turbine for sale. B0w2m2sq The turbine is manufactured in 2009 with 93 bar inlet pressure and 3bar back pressure. The turbine was driving a feed water pump. more
Turbine completely modernized in 2015 Hgqfiff Technical data : Pair quantity : 15 t/h max Pair parameters at the input: 39 bar, 390C Output steam parameters: 2.0 bar 220 V 50 HZ generator In very good technical condition. Turbine controls replaced in 2015 with new Serviced every year more
N.1 Brown Boveri 8700 Kw turbo alternator, steam input at 32 bar, steam capacity 87 ton/h. N.1 de Pretto-Escher Wyss 6000 Kw turbo alternator, steam supply at 36 bar, steam flow rate 58 ton/h. N.1 Elin M40 turbo alternator 2500 Kw, steam supply at 35 bar, steam flow rate 34,6 ton/h. N.1 Blohm-Foss turbo alternator 2600 Kw, steam delivery at 35 bar, steam delivery at 31,8 ton/h. Nxonh ** SINGLE PRODUCT SALE, PRICE SUBJECT TO NEGOTIATION**. more
Berlin, Germany Germany
dealership location
17594 km
ready for operation (used)
There are 96 electric motors available, 13x HANNING E7 KA4B-856, power: 0.18kW and 83x HANNING 9LLK2-884, power: 3kW. Dofstqvn3 more
Steam turbine - back pressure turbine FT7 G315 with accessories. inlet pressure: 11,5 bar Bhobszrwlr Steaming temperature: 215°. Exhaust steam pressure: 8.9 bar Turbine speed: 3550 rpm Output: 481 kW Generator: 950 kVA Year of construction: 2004 Documentation / documents are available. more
Nominal output: 22 KW to 50 KW Speed: 2980 rpm Live steam pressure: 12.3 bar to 30 bar Live steam temperature: 300 ° C to 300 ° C Evaporation pressure: 2.6 bar to 2.6 bar E83szwv spec. Steam consumption: 43.7 kg / KWh to 33.7 kg / KWh Live steam quantity 0.96 t / h max - 0.41 t / h max Blade length 24mm Duese Form: D - Form A Implementation 7 to 10 Valve 4 (6.3 cm³) to 2 (2.5 cm³) more
Technical data : Pair quantity : 39.5 t/h max Pufqa3 Input steam parameters :42 bar, 400C Output steam parameters: 2.5 bar, 155C Turbine in very good technical condition . Upgraded to the current state of the art. Turbine control - Wooworth Serviced every year more
Berlin, Germany Germany
dealership location
17594 km
2004
ready for operation (used)
There are two motors available, power: 100kW, rotational speed: 3200/min, weight: 284kg. Bg77lvludm more
Technical data : Pair quantity : 52.5 t/h max Input steam parameters :40 bar, 400C Output steam parameters: 2.5 bar Turbine in very good technical condition . Upgraded to the current state of the art. Turbine control - Wooworth Biunw0o0io Serviced every year more
ABB DMA 400 K32W
1
Berlin, Germany Germany
dealership location
17594 km
1992
ready for operation (used)
Power: 700kW, rotational speed: 1500/min, weight: 2.79t. Bhspz7fquy more
Complete power-plant : Dwwogu Fuel feeding system 2 boiler lines : 45 bar, 420°C, 25 t/h (2 x 12.5 t/h) SES Turbine : 5 MW Blohm & Voss - MAN-Turbo Extraction parameters : 2.4 bar (0 - 20 t/h) Steam condenser type: ACC (Air Cooled Condenser) Generator parameters: 6.250 kVA, 6.3 kV, 50 Hz - Schorch/LDW Commissioning year : 1999 A note: Plant is not in operation since june 2015 more
Berlin, Germany Germany
dealership location
17594 km
1998
ready for operation (used)
Power: 700kW, weight: 3.52t. Nv9iz more
One second hand KKK backpressure steam turbine CFR5 G4 manufactured 1988 in good working condition for sale. FCA free loaded on truck / container. The turbine is located in our warehouse in D-Bergisch Gladbach. Alternators with other voltages are also available. Scope of supply: control panel, two pallets with small parts type: KKK CRF5 G4 el. power: 1240 KW generator end: AVK 400 volt,1170 KVA, 50 hz, 1500 r/min steam consumption: 16 to / h at 1240 KW el. output steam inlet pressure: 19 bar... more
Berlin, Germany Germany
dealership location
17594 km
ready for operation (used)
There are two induction motors available, 1x 2AD180D, 1x 2AD160B, weight: 205kg, condition: 1x new, 1x used. Bfpj2hzl8w more
1300 KW KK&K Type: CFR3 G5A / AFA 4G5A Tandem condensing steam turbine 40 Bar (HP) 10 Bar (LP) Inlet pressure with 50.000 operating hours from 1997 for sale. Scope of delivery: Generator and turbine, Documents, sound insulation hood. Brand: KK&K Type: CFR3 G5A / AFA 4G5A Power: 1300KW Operating hours: 50.000 Live steam pressure: 40 bar (HP) 10 bar (LP) Year of construction: 1997 Generaror: AEM Type: SE 500 M4 Power: 1830 KVA Voltage: 400 Volt rpm: 1500 rpm Frequency: 50 Hz Bizclsn8ph A suitable ... more
SCHORCH KN7315S-AB01B-462
1
Berlin, Germany Germany
dealership location
17594 km
2006
ready for operation (used)
There are two identical three-phase motors available, rotational speed: 2975-3575/min, voltage: 400-460V, current: 161-280A. Yr2q3g more
Berlin, Germany Germany
dealership location
17594 km
1984
used
Kühnle, Kopp, Kausch back pressure steam turbine, with Avk generator DKB 80/500-4TS, revoultion 1500 1/min, input steam pressure 42 bar, temperature 400, exhaust pressure 3.5 bar, throughput 2800-4800 kg/h B2crtyunu more
A used Siemens Twin AFA 46 GT6 Condensing steam turbine from 2009 for sale. Brand: Siemens Type: Twin AFA 46 GT6 Power: 3,273 KW Live steam pressure: 26 bar Bixquehdyl Live steam temperature: 400 ° C Year of construction: 2009 General: AVK Voltage: 6,300 V Power: 4125 KVA RPM: 1500 RPM Frequency: 50 Hz Steam turbine with generator costs € 163,000. A water-cooled condenser costs € 75,000 extra. FCA free loaded Bergisch-Gladbach shop. more
One second hand KK&K Siemens Twin AFA 46 GTA condensing steam turbine manufactured in 1999 with only 35.000 working hours in canopy for sale. Include is generator switchgear 10 KV with the control panel and a Serck-Como vacuum- condenser from 2006 (20 to/h). Additional we can offer many many spare parts like spare rotors and controllers. Scope of supply: control panel / generator switchgear 10 KV vacuum condenser / condenser pumps / canopy turbine: KKK Siemens type: Twin 46 el. power: 3.600 K... more
8250 KWel Allen H3-PO-800 condensing steam turbine package 10.180 KVA. FCA in our warehouse D-Bergisch Gladbach. Allen H3-PO-800 condensing steam turbine from 1999 with two condensers and the control pannels for sale. . Scope of supply: two condensers,control pannels, pallets with valves and pumps, two pallets of documents. turbine: Allen type: H3-PO-800 el. power: 8250 KW running hours: time since new 70137 steam consumption: 32 to/h at full load steam inlet pressure... more


SELL IMMEDIATELY

with the worldwide market leader from 0,99 EUR per listing.
Find out more


Phone: +44 (0) 20 806 810 84
or sell immediately

Machineseeker.nz is official sponsor of:
Flag gb
+44 (0) 20 331 800 72
Flag de
+49 (0) 201 857 86 10
Flag nl
+49 (0) 201 857 86 180
Flag pl
+48 (0) 223 076 958
Flag it
+49 (0) 201 857 86 152
Flag es
+34 (0) 911 433 456
Flag fr
+49 (0) 201 857 86 153
Flag us
+44 (0) 20 331 800 72