Description
Vötsch
Type: VC³ 7018
Vötsch Air-Cooled Climatic Test Chamber
Temperature Test:
Temperature Range: -70°C to +180°C
Temperature Rate: Heating 4 K/min
Temperature Rate: Cooling 3 K/min
Climatic Test:
+10°C to +95°C
Humidity Range: 10% to 98% RH F.
Temperature deviation over time: ± 0.1 to ± 0.3 K
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Ijdpox Hg Uusfx Aktjtg
Nominal voltage: 400 V
Nominal current: 14 A
Nominal power: 5.5 kW
Heat compensation 1500 W (at 20+)
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Type: VC³ 7018
Vötsch Air-Cooled Climatic Test Chamber
Temperature Test:
Temperature Range: -70°C to +180°C
Temperature Rate: Heating 4 K/min
Temperature Rate: Cooling 3 K/min
Climatic Test:
+10°C to +95°C
Humidity Range: 10% to 98% RH F.
Temperature deviation over time: ± 0.1 to ± 0.3 K
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1550 mm x Height 1800 mm
Test chamber volume: 190 liters
Ijdpox Hg Uusfx Aktjtg
Nominal voltage: 400 V
Nominal current: 14 A
Nominal power: 5.5 kW
Heat compensation 1500 W (at 20+)
Weight: approx. 460 kg
For your safety, please note the following information!
The following steps are carried out in advance on our chambers:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical specifications, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Balaguer
19,532 km
Welding machine
KEMPPIPRO 3000
KEMPPIPRO 3000
Listing
Auenwald
18,582 km
ZEISS Prismo 16 - 16.30.10
ZEISSPRISMO 16
ZEISSPRISMO 16
Listing
Germany
18,260 km
Welding Unit
KEMPPIPro MIG 500
KEMPPIPro MIG 500
Listing
Saarbrücken
18,716 km
Multisensor measuring machine Mahr MS222
MahrMS 222 Komplettpaket mit Lieferung*
MahrMS 222 Komplettpaket mit Lieferung*
Listing
Crailsheim
18,536 km
Tugger
RofanTPR-10
RofanTPR-10
Listing
Borken
18,513 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Listing
Weilheim an der Teck
18,598 km
ACCURA II MASS 16/42/15
ZeissACCURA II MASS 16/42/15
ZeissACCURA II MASS 16/42/15
Listing
Auenwald
18,582 km
Coordinate measuring machine
ZEISSPrismo 10 - 12.24.10 mit REVO2
ZEISSPrismo 10 - 12.24.10 mit REVO2
Listing
Borken
18,513 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
WeissSB2/500/80 -75°C bis +180°C
Listing
Mönchengladbach
18,595 km
Coordinate measuring machine
MitutoyoEuro C Apex 9166
MitutoyoEuro C Apex 9166
Your listing has been deleted successfully
An error has occurred