Analysis system glucose, hemoglobinTrace Analytics
GL compact
Analysis system glucose, hemoglobin
Trace Analytics
GL compact
ONO plus VAT
€2,185
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Analysis system glucose, hemoglobin
- Manufacturer:
- Trace Analytics
- Model:
- GL compact
- Condition:
- good (used)
Price & Location
ONO plus VAT
€2,185
- Location:
- Dunkerstrasse 29, 46325 Borken/Burlo, DE
Call
Details about the offer
- Listing ID:
- A16242352
- Reference number:
- 38246
- Update:
- 06.08.2025
Description
Trace LaboTrace GL compact analyzer system haemoglobin, glucose and lactate *new price 4343 ,-€
The GL Compact is a versatile multi-use system that sets new standards in near-patient diagnostics thanks to its small footprint. With minimal effort, it delivers precise results in just 45 seconds. The system is quickly ready for use and meets the high demands placed on laboratory systems thanks to its proven measurement technology.
The parameters glucose, lactate and haemoglobin can all be determined from a single sample, maximizing efficiency and saving time.
Itedpfsttzzuex Afion
The system automatically recognizes whether whole blood is used or not. For whole blood samples, it determines the hematocrit value in addition to the glucose value, providing plasma-related glucose values in accordance with the guidelines. There is no need for daily device maintenance as the system flushes and calibrates itself. This makes it just as user-friendly as a point-of-care test device.
Glucose, lactate and haemoglobin parameters
Sample material Capillary whole blood, plasma, serum
Sample volume 10 µL in 500 µL hemolysate
Measuring principle Biosensor for glucose/lactate
Photometer for hemoglobin
Shelf life of glucose/lactate sensor: 3 months
Glucose: 6 months
Measuring time 45 seconds
Measuring range glucose: 0.6 - 50 mmol/l (11 - 910 mg/dl)
Lactate: 0.5 - 30 mmol/l (4.5 - 270 mg/dl)
Haemoglobin: 1.9 - 19 mmol/l (3.0 g/dl - 30 g/dl)
Precision glucose: < 1.5 % at 12.0 mmol/l (216 mg/dl)
Lactate: < 2.0 % at 10.0 mmol/l (90 mg/dl)
Haemoglobin: < 1.5% at 7.6 mmol/l (12 g/dl)
Weight 2.5 kg
Dimensions (W x H x D [mm]) 200 x 150 x 170
Item condition: used
You can find more new and used items in our store!
International shipping costs on request!
The GL Compact is a versatile multi-use system that sets new standards in near-patient diagnostics thanks to its small footprint. With minimal effort, it delivers precise results in just 45 seconds. The system is quickly ready for use and meets the high demands placed on laboratory systems thanks to its proven measurement technology.
The parameters glucose, lactate and haemoglobin can all be determined from a single sample, maximizing efficiency and saving time.
Itedpfsttzzuex Afion
The system automatically recognizes whether whole blood is used or not. For whole blood samples, it determines the hematocrit value in addition to the glucose value, providing plasma-related glucose values in accordance with the guidelines. There is no need for daily device maintenance as the system flushes and calibrates itself. This makes it just as user-friendly as a point-of-care test device.
Glucose, lactate and haemoglobin parameters
Sample material Capillary whole blood, plasma, serum
Sample volume 10 µL in 500 µL hemolysate
Measuring principle Biosensor for glucose/lactate
Photometer for hemoglobin
Shelf life of glucose/lactate sensor: 3 months
Glucose: 6 months
Measuring time 45 seconds
Measuring range glucose: 0.6 - 50 mmol/l (11 - 910 mg/dl)
Lactate: 0.5 - 30 mmol/l (4.5 - 270 mg/dl)
Haemoglobin: 1.9 - 19 mmol/l (3.0 g/dl - 30 g/dl)
Precision glucose: < 1.5 % at 12.0 mmol/l (216 mg/dl)
Lactate: < 2.0 % at 10.0 mmol/l (90 mg/dl)
Haemoglobin: < 1.5% at 7.6 mmol/l (12 g/dl)
Weight 2.5 kg
Dimensions (W x H x D [mm]) 200 x 150 x 170
Item condition: used
You can find more new and used items in our store!
International shipping costs on request!
Seller
Note: Register for free or log in, to access all information.
Send inquiry
Telephone & Fax
+49 2862 ... show
Your listing has been deleted successfully
An error has occurred