Temperature chamber 986 litersThermotron
SE-1000-6-6 -70°C bis + 180°C
Temperature chamber 986 liters
Thermotron
SE-1000-6-6 -70°C bis + 180°C
Condition
Used
Location
Borken 

Machine data
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A22148057
- Reference number:
- 23309
- Update:
- 18.06.2026
Description
Here we offer you a Thermotron temperature chamber.
Water-cooled
Thermotron Temperature Chamber SE-1000-6-6
Internal dimensions (W x D x H): 1000 x 1000 x 980 mm
Working chamber volume: approx. 980 liters
Temperature range: -70ºC to 180ºC
Overall heating rate: approx. 4.1 K
Overall cooling rate: approx. 1.2 K
Heating capacity (°C/min) -65º to 71ºC: 6.8°C
Heating capacity (°C/min) -65º to 180ºC: 5.6°C
Heating capacity (°C/min) -40ºC to 85ºC: 6.5°C
Cooling capacity (°C/min) 85ºC to -40ºC: 4.7°C
Cooling capacity (°C/min) 71ºC to -65ºC: 3.7°C
Cooling capacity (°C/min) 180ºC to -65ºC: 4.3°C
External dimensions (W x D x H): 1250 x 1900 x 2200 mm
Electrical requirements: 400V / 5P / N / PE, 35 A
Refrigerants: R508B and R404A
Approximate weight: 900 kg
Type: Thermotron SE-1000-6-6
Important information for you as a buyer:
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Subject to change and errors in the technical data and information!)
If you have any further questions, we will be happy to assist you by phone.
Itedszd R T Hjpfx Abfjh
The listing was translated automatically. Translation errors are possible.
Water-cooled
Thermotron Temperature Chamber SE-1000-6-6
Internal dimensions (W x D x H): 1000 x 1000 x 980 mm
Working chamber volume: approx. 980 liters
Temperature range: -70ºC to 180ºC
Overall heating rate: approx. 4.1 K
Overall cooling rate: approx. 1.2 K
Heating capacity (°C/min) -65º to 71ºC: 6.8°C
Heating capacity (°C/min) -65º to 180ºC: 5.6°C
Heating capacity (°C/min) -40ºC to 85ºC: 6.5°C
Cooling capacity (°C/min) 85ºC to -40ºC: 4.7°C
Cooling capacity (°C/min) 71ºC to -65ºC: 3.7°C
Cooling capacity (°C/min) 180ºC to -65ºC: 4.3°C
External dimensions (W x D x H): 1250 x 1900 x 2200 mm
Electrical requirements: 400V / 5P / N / PE, 35 A
Refrigerants: R508B and R404A
Approximate weight: 900 kg
Type: Thermotron SE-1000-6-6
Important information for you as a buyer:
The following points are carried out in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a test run monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Subject to change and errors in the technical data and information!)
If you have any further questions, we will be happy to assist you by phone.
Itedszd R T Hjpfx Abfjh
The listing was translated automatically. Translation errors are possible.
Send inquiry
Telephone & Fax
+49 2861 ... show
Your listing has been deleted successfully