Temperature shock test systemRS-Simulatoren
ST2K320/45 K
Temperature shock test system
RS-Simulatoren
ST2K320/45 K
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Temperature shock test system
- Manufacturer:
- RS-Simulatoren
- Model:
- ST2K320/45 K
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, DE
Call
Details about the offer
- Listing ID:
- A16192489
- Reference number:
- 24112
- Update:
- 15.11.2024
Description
RS. simulators
Type: ST2K320/45 K
Water-cooled shock test system
Temperatures in the upper test chamber
Temperature range: + 40 °C to + 180 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Temperatures in the lower test chamber
Temperature range: - 40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Humidity in the upper test room
Climatic temperature range: + 40 °C to +90 °C
Humidity range: 20 % to 98 % (± 2 to 5 %) relative humidity
Humidity: 25% to 75% relative humidity
Working climate range:
Temperature: + 12 °C to + 30 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 900 mm Height 2000 mm Depth 2300 mm
Test room dimensions: Width 470 mm Depth 700 mm Height 440 mm
Godetrf Ulepfx Afijbu
Electrical power supply:
Total power: 13 KVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
The listing was translated automatically. Translation errors are possible.
Type: ST2K320/45 K
Water-cooled shock test system
Temperatures in the upper test chamber
Temperature range: + 40 °C to + 180 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Temperatures in the lower test chamber
Temperature range: - 40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with empty test chamber
Humidity in the upper test room
Climatic temperature range: + 40 °C to +90 °C
Humidity range: 20 % to 98 % (± 2 to 5 %) relative humidity
Humidity: 25% to 75% relative humidity
Working climate range:
Temperature: + 12 °C to + 30 °C
Humidity: 25 % to 75 % relative humidity
Dimensions: Width 900 mm Height 2000 mm Depth 2300 mm
Test room dimensions: Width 470 mm Depth 700 mm Height 440 mm
Godetrf Ulepfx Afijbu
Electrical power supply:
Total power: 13 KVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.