Used Temperature Test Chamber -20°C...+140°C for sale (78,949)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Kleinmaischeid
18,585 km
Refrigerator body van
MERCEDES-BENZSprinter 317CDI Tiefkühlkoffer-20°C Klima Navi
Call
Condition: used, mileage: 142,828 km, power: 125 kW (169.95 HP), first registration: 10/2024, fuel type: diesel, overall weight: 3,500 kg, next inspection (TÜV): 10/2026, color: white, emission class: euro6, loading space length: 3,450 mm, loading space width: 1,870 mm, loading space height: 1,920 mm, Equipment: ABS, air conditioning, had accident, navigation system, soot filter, Euro 6 green environmental badge, Kress refrigerated box – 20°C, cooling unit from Carrier Pulsor 400Mt, standby cooling 380V, 2-zone cooling with 2 evaporators, loading dimensions L = 3.45m W = 1.87m x H = 1.92m, MBUX with 10.25" display, automatic climate control, navigation, rearview camera, permissible total weight 3500 kg, payload 720 kg, multi-function steering wheel, 2 seats, electric windows, central locking, airbag, ABS, ASR, German vehicle, first owner, original mileage with service booklet. Subject to prior sale and errors. Sale only to commercial businesses or for export. Vehicle number: 47.
Blodpfezhzf Iox Adrji
Listing
Kleinmaischeid
18,585 km
Refrigerator body van
MERCEDES-BENZSprinter 315CDI Tiefkühlkoffer-20°C Klima Navi
Call
Condition: used, mileage: 140,925 km, power: 110 kW (149.56 HP), first registration: 11/2022, fuel type: diesel, overall weight: 3,500 kg, next inspection (TÜV): 10/2026, color: white, emission class: euro6, Equipment: ABS, air conditioning, had accident, navigation system, soot filter, Euro 6 compliant, with a green environmental badge, refrigerated box – 20°C, refrigeration unit by Mitsubishi, stand-by cooling 230V, 2-zone cooling with partition, temperature recorder, automatic climate control, navigation, rear-view camera, GVWR 3500 kg, payload 820 kg, multi-function steering wheel, 2 seats, electric windows, central locking, airbag, ABS, ASR, German vehicle, first owner, original mileage with service booklet – subject to prior sale and errors – sale only to commercial businesses or for export – vehicle number: - 32
Bjdpfx Adjzhzfbsrjli
Listing
Kleinmaischeid
18,585 km
Refrigerator body van
MERCEDES-BENZSprinter 314CDI Tiefkühlkasten-20°C Klima Navi
Call
Condition: used, mileage: 321,924 km, power: 110 kW (149.56 HP), first registration: 05/2019, fuel type: diesel, overall weight: 3,500 kg, next inspection (TÜV): 08/2026, color: white, emission class: euro6, Equipment: ABS, air conditioning, soot filter, Used vehicle
* Vehicle No.: - 97
* Euro 6 green emissions sticker
* Deep-freeze box -20°C
* Cooling unit by Carrier
* Standby cooling 230V
* Temperature recorder
* Automatic climate control
* Reversing camera
* GVW 3500 kg
* Multifunction steering wheel
* 2 seats
Bljdpfx Adsynp Swersi
* Electric windows
* Central locking
* Airbag
* ABS
* ASR
* German vehicle
* Original mileage with service history
----
-> Please note that viewing is possible by appointment only. Thank you for your understanding.
-> Sale only to businesses or for export.
The data, photos and specification list above serve solely for general identification of the vehicle and do not constitute a warranted characteristic under sales law! All details/accessory information is supplied WITHOUT GUARANTEE. Subject to alterations, prior sale, and errors!
The equipment list does not form part of the contract and must be checked in detail by each interested party on site prior to purchase. Subsequent complaints will not be recognized.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
18,513 km
Climatic chamber temperature and humidity
EspecPHP-J3 bis +100°C
Call
Condition: excellent (used), Espec
Type: PHP - J3
Technical Data:
Air-cooled
Temperature and humidity range: Ambient temperature +10°C to +100°C / 40 to 98% relative humidity
Temperature fluctuation: ±0.3 K
Humidity fluctuation: ±2.5%
Internal volume: 398 liters
Dimensions:
Bedpfxszgtaho Adrsli
Internal dimensions: Width 600 mm x Height 830 mm x Depth 800 mm
External dimensions: Width 1010 mm x Height 1690 mm x Depth 1273 mm
Mains voltage: 400 VAC 3-phase 50 Hz
Maximum current: 400 VAC 8.3 A
Weight: 335 kg
Scope of delivery: Espec climate test chamber
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Sottrum
18,303 km
Reefer trailer
SchmitzSCB*C2 TK -20°C Thermo King LBW 2t. Durchlader
Call
Condition: used, empty load weight: 6,930 kg, maximum load weight: 11,070 kg, overall weight: 18,000 kg, first registration: 08/2018, next inspection (TÜV): 12/2026, loading space length: 7,400 mm, loading space width: 2,450 mm, loading space height: 2,400 mm, loading space volume: 43 m³, total height: 91,650 mm, suspension: air, color: blue, Year of construction: 2018, gearing type: other, driver cabin: other, Equipment: ABS, cooling unit, tail-lift, * German trailer
* Condition: see photos
* 2-axle Schmitz tandem trailer, type SCB*C2
* Body: Reefer box with Thermo King underfloor refrigeration unit, type UT1200
* Freezer with a cooling capacity of 0°C to -20°C
* Standby and en-route cooling via diesel and electric drive
* Cargo space dimensions: Length 7,400 mm x Width 2,450 mm x Height 2,400 mm
* Front portal doors, 270° for drive-through loading
Bledpfx Ajzhxlledrei
* Multiple anchor rails on the right, left, and top
* Rear portal doors, 270°
* Tail lift BÄR, type BC 2000 S4 - C4
* Load capacity 2,000 kg
* Mercedes Actros 2645 with Thermo King refrigeration unit UT1200, available at an extra cost
* 3 Jost landing gears
* Schmitz axles
* Air suspension
* ABS + EBS
* Rearview camera
* GVWR 18,000 kg
* Unladen weight 6,930 kg
* Payload 11,070 kg
* Cargo volume 43 m³
If a new TÜV inspection is desired, we will gladly provide you with a quote from our partner workshops.
Our offer generally does NOT include a new TÜV inspection, a new DGUV assessment, a new risk assessment (SP), or a new occupational safety assessment (UVV).
You can find more trucks on our website at:
We speak the following languages: German, English, Polish, Turkish.
Note:
We strongly recommend and offer the possibility of inspecting and examining the goods to ensure that the buyer does not have any false impressions regarding the condition and suitability. Inspections and examinations are possible at any time by appointment and are expressly desired.
All information is without guarantee. No liability is assumed for errors and incorrect information in the offer. The buyer is obliged to independently verify the condition and equipment of the goods/vehicles.
Subject to change, prior sale, and errors.
Listing
Lorquí
19,581 km
S/S SIDEL SF ASEPTIC 70/20 C ASEPTIC FIL
Sidel
Call
Condition: used, functionality: fully functional, This line consists of:
- Filler
- Capping machine and cap feeder
Bedpfxjx S Eu Dj Adroli
Production capacity will depend on the packaging format and the product to be filled.
ZALKIN CAPPER specifications:
* Model: T6069
* Number of heads: 20
* Output: 25,000 bottles/hour
Zalkin capping machines are designed for crimping aluminum screw caps (for carbonated and non-carbonated beverages). They can also be configured for the application of various types of aluminum or plastic closures (pre-sealed aluminum or plastic caps, screw-on or tamper-evident caps).
The SIDEL cap elevator/orientator combines three functions in one: lifting, orientation, and feeding. The system efficiently orients caps while optimizing footprint. The design allows orientation of caps from 20 mm to 120 mm in diameter, in plastic or metal, based on geometric shape.
Throughput reaches up to 2,000 caps/minute for standard formats and 1,000 caps/minute for sports-type caps. The cap feeder easily interfaces with the SIDEL cap air conveyor, eliminating the need for precise positioning of the unit.
Listing
Borken
18,513 km
Climate test chamber 335 liters 10-98% relative humidity.
VötschVC³ 0034 -10 °C bis +90 °C
Call
Condition: excellent (used), Vötsch VC³ 0034 Climate Test Chamber
Blodpszgb Awefx Adroi
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC³ 0034
Machine Type: Climate Test Chamber / Climate Chamber
Test Chamber Volume: approx. 335 liters
For sale is a used climate test chamber from Vötsch for temperature and climate testing in laboratories, research, development, and quality assurance.
Technical Data
Test Chamber Dimensions: approx. 580 x 765 x 750 mm (W x D x H)
Housing Dimensions: approx. 875 x 1860 x 1805 mm (W x D x H)
Temperature Range: -10 °C to +90 °C
Humidity Range: 10 to 98 % RH
Dew Point Range: +4 °C to +89.5 °C
Temperature Homogeneity: ±0.5 to ±1 K
Temperature Deviation: ±0.1 to ±0.5 K
Heating Rate: approx. 1 K/min
Cooling Rate: approx. 0.3 K/min
Max. Heat Compensation: approx. 200 W
Refrigerant: R404A
Filling Quantity: 0.6 kg
ND max.: 25 bar g
HD max.: 25 bar g
Power Connection: 230 V / 50 Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Protection Class: IP54
Weight: approx. 490 kg
Equipment
SIMPAC control system
Temperature and humidity control
Stainless steel test chamber
Ethernet, USB, RS232, RS485/422
Test item protection function
Cable glands
Application Areas
Climate testing
Temperature testing
Material testing
Electronics testing
Quality assurance
Research and development
Scope of Supply
Vötsch VC³ 0034 Climate Test Chamber
Accessories as shown in the pictures
Condition
Used
Optical condition as shown in the pictures
For the safety of our customers, the offered climate chambers are tested before delivery,
if necessary, filled with legally compliant refrigerant, subjected to a leak test,
and delivered with a documented test run.
Subject to change and errors in technical data as well as prior sale.
Listing
Borken
18,513 km
Thermal shock test chamber
RS-SimulatorenST2K320/45 K
Call
Condition: excellent (used), RS Simulators
Type: ST2K320/45 K
Shock test system, water-cooled
Temperatures in the upper test chamber
Temperature range: +40 °C to +180 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Temperatures in the lower test chamber
Temperature range: -40 °C to +100 °C
Time deviation: ± 0.8 K according to DIN 50011 with an empty test chamber
Humidity levels in the upper test chamber
Climate temperature range: +40 °C to +90 °C
Humidity range: 20% to 98% (± 2 to 5%) relative humidity
Humidity: 25% to 75% relative humidity
Operating climate range:
Temperature: +12 °C to +30 °C
Humidity: 25% to 75% relative humidity
Dimensions: Width 900 mm, Height 2000 mm, Depth 2300 mm
Test chamber dimensions: Width 470 mm, Depth 700 mm, Height 440 mm
Electrical power supply:
Total power: 13 kVA
Current consumption: 25 A
Voltage: 3x400V/N/PE / 50Hz
Refrigerant: R404A/2.5 kg
Chamber: approx. 950 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Bsdpfx Aezgbutsdroli
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
18,513 km
Dust test chamber dust chamber
Testzentrum Baden Primus EngineeringDST350
Call
Condition: excellent (used), Primus Engineering
Type: DST 350
This testing equipment was designed for performing IP protection class tests for "dust" according to, for example, DIN 40050 Part 9 and DIN EN 60529.
The testing equipment is intended for testing technical components under the influence of dust and negative pressure within the limits specified in the technical data.
Operation / HMI
Control panel with screen and buttons
Manual controls
Predefined test sequences
Integrated vacuum circuit with flow measurement
Technical data:
Total electrical power: Max. 5 kW
Connection voltage: 400V/50Hz 3-N/PE (16A CEE socket)
Dimensions: Width approx. 920 mm, Depth approx. 710 mm, Height approx. 1,770 mm
Dimensions of test chamber: Width approx. 700 mm, Depth approx. 650 mm, Height approx. 770 mm
Volume approx. 350 l
Weight: approx. 200 kg
Vacuum: 0 to -100 mbar
Suction air flow: 0 to approx. 5 l/min
Operating climate range: Temperature: +12 °C to +30 °C
Humidity: 25 % rel. to 75 % rel., non-condensing
Bodpszgbtisfx Adreli
Protection class tests according to DIN 40050 Part 9 and DIN EN 60529 (VDE 0470 Part 1)
Dust test:
Dust-protected IP5X and IP5KX
Dust-tight IP6X and IP6KX
with and without vacuum
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
18,513 km
Temperature test chest 680 liters
Heraeus VötschVLM 3068/S -30 °C bis +125 °C
Call
Year of construction: 2010, condition: excellent (used), Here, we offer a Heraeus Vötsch temperature testing chamber.
Vötsch temperature testing chamber, test cabinet VLM 3068/S, air-cooled
(top-loading test chambers for construction materials)
Control panel
The control panel is mounted on a console on the temperature testing chamber. All control and operating commands can be initiated by simply touching the function symbols. The operating manual for the control panel is included.
Main switch
The main switch is located at the front of the temperature testing chamber.
Air handling unit
The air handling unit is located in the test chamber and contains the components necessary for temperature control.
In the air handling unit, the air is conditioned (cooled/heated) and circulated through the test chamber by the test chamber fan. The air is drawn in at the center of the side wall and re-enters the test chamber via the air guide plates on the long sides.
Feedthroughs
The temperature testing chamber can optionally be equipped with feedthroughs. These allow cables and testing equipment to be placed in the test chamber.
Feedthrough at the front: 2 x 82 mm diameter, at the rear: 1 x 85 mm diameter
Internal dimensions: width 2000 mm, depth 570 mm, height 600 mm
External dimensions: width 3000 mm, depth 870 mm, height 1060 mm
Bledjzgbmijpfx Adrei
Technical data:
Data for mechanical load:
max. load with test specimen
Test chamber floor
(evenly distributed over the area) 600 kg
Point load 50 kg
Data for temperature tests:
Temperature range -30 °C to +125 °C
Temperature deviation over time in the center of the usable space ±1 K
Temperature change rate
Heating approx. 1 K/min
Cooling approx. 2 K/min
Data for operation:
Rated voltage 3/N / PE AC 400 V ±10% 50 Hz
Rated power 3 kW, rated current 9 A
Fuse on customer side: 16A, slow-blow
Temperature testing chamber VLM 3068/S
Test chamber volume approx. 680 l
Weight approx. 700 kg
Refrigerant: R-404A
Noise measurement: sound pressure level approx. 68 dB(A)
Type: VLM 3068/S
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have by telephone.
Listing
Borken
18,513 km
Climate test chamber with humidity, 335 liters
WeissWK3-340/40 -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate testing chamber.
Weiss climate testing chamber, water-cooled
(Refrigerant converted to R-452A)
Temperature testing
Bjdpfx Aozgavvjdreli
Volume 335 liters
Test chamber dimensions:
Test chamber dimensions: Height 750 mm, Width 580 mm, Depth 765 mm
External dimensions: Height 1775 mm, Width 870 mm, Depth 1600 mm
Minimum temperature -42°C
Maximum temperature +180°C
Temperature change rate, cooling 4 K/min
Temperature change rate, heating 3.2 K/min
Temperature deviation, time-based ± 0.1 to ± 0.5 K
Temperature homogeneity, spatially ± 0.5 to ± 1.5 K
Climate testing:
Temperature range +10°C to +95°C
Dew point range -3°C to +94°C
Humidity range 10 to 98% RH
Temperature deviation, time-based ± 0.1 to ± 0.3 K
Temperature homogeneity, spatially ± 0.5 to ± 1 K
Humidity deviation, time-based ± 1 to ± 3 % RH
Voltage: 3/N/PE AC 400V±10% 50Hz
Rated power 4.1 kW Rated current: 14 A
Refrigerant: R-452A
Type: WK3-340/40
Weight Approx. 515 kg
For your security as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Temperature chamber TPK 200, 280 liters
FeutronTyp: 3416/17 -70°C bis +180°C
Call
Condition: excellent (used), Here we offer a temperature test chamber.
Feutron Temperature Test Chamber, Air-Cooled
Test chamber nominal volume: 280 liters
Dimensions:
Bedpfozgah Sox Adreli
External dimensions of the test chamber: Width 1540 mm x Height 2090 mm x Depth 1240 mm
Fan motor and door removed: Width 1540 mm x Height 1940 mm x Depth 925 mm
Test chamber: Width 720 mm x Height 690 mm x Depth 560 mm
Door, clear opening: Width 720 mm x Height 690 mm
Viewing window, heated: Width 500 mm x Height 600 mm
Installation dimensions of the temperature test chamber with doors open
Width 2340 mm x Height 2090 mm x Depth 2165 mm
Feed-through opening, 2 pieces on the side wall, left: Ø 100 mm
Temperature range
-70°C to +180°C
Heating: 3.0 K / min
Cooling: 3.0 K / min
Mains connection: 400 V 3/N/PE, AC, 50 Hz
Maximum power consumption: 6.3 kW
Weight: 635 kg
Type: 3416/17
Refrigerant: R507 / R23
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Szigetszentmiklós
17,990 km
CNC lathe
HAASSL 20 cnc lathe with C-axis
Call
Condition: excellent (used), Year of construction: 2008, HAAS SL20 CNC lathe with C-axis
Year: 2008
Technical details:
HAAS control
Maximum turning length (Z-axis): 610 mm
Maximum turning diameter over bed: 262 mm
C-axis with driven tools
Spindle power: 14,7 kW Vector Drive
Spindle bore diameter: 51 mm
Max spindle speed: 4000 rpm
Number of turrets: 1
Number of tools in turret: 10
Spindle nose A2-6
Tailstock
Weight approx. 4800 kgs
Dimensions (L x W x H): 2600 x 1700 x 1800 mm
Accessories/options:
- C-axis and driven tools
- Static tool holders
- Driven tool holders
- Servo bar barfeeder
- Swarf auger
- Coolant system
- Tailstock
- Tool measuring arm
- Hydraulic 3-jaw chuck
- Collet type chuck
Bsdpfx Aezf Rrrjdreli
- Foot pedals
Dust extractor is not included.
Listing
Wiefelstede
18,341 km
Thermostat
Trafag471,2331 20 bis 150 °C
Call
Condition: excellent (used), Temperature controller, temperature sensor, temperature setting, temperature converter, temperature limiter, electronic temperature controller, temperature switch, thermostat, sensor
-Manufacturer: Trafag, thermostat temperature switch, unused, original packaging
-Type: 471 2331 342 27 8319 0065
-Temperature range: 20 to 150 °C
Bjdpfx Adolc Uiieroli
-Cable length: 3000 mm
-Quantity: 1 thermostats available
-Price: per piece
-Package dimensions: 245/130/H80 mm
-Weight: 1.1 kg/pc.
Listing
Meiningen
18,424 km
Chamber furnace 800°C, electric, gas-tight muffle
Linn High ThermKS-3-480-Vac Spezial 720 Liter
Call
Condition: reconditioned (used), Year of construction: 2009, machine/vehicle number: SN FX036084, functionality: fully functional, 12 months warranty, in-stock item, immediately available, in excellent condition.
Resistance-heated system with a gas-tight furnace chamber suitable for hardening, soldering, sintering, annealing, ashing, and preheating.
- Tmax 800°C
- Rod-type programmable controller SE-402
- 3-zone heating
- Gas supply system
- Max. gas operating pressure 7 mbar
- Gas circulation
- Gas supply system, vacuum-tight
- Gas purging system
- Vacuum system
- Caution: no safety package installed!
- Internal furnace chamber dimensions (W x D x H) 580 x 830 x 1500 mm (special length)
- Furnace chamber volume approx. 722 liters
- Max. load weight approx. 1000 kg
- Two-stage rapid cooling with frequency converter
- Afterburner with flame monitoring
- Automatic shutdown / emergency purging in case of flame failure, not in case of power failure!
- Viewing window DN150
- Max. gas operating pressure 7 mbar
- Power supply 400V, 3 phases, N, PE
- Heating power 70 kVA
- Rated current 3x97A
- Weight 1900 kg
- External furnace dimensions (W x H x D) 1700 x 1950 x 2750 mm
- Control cabinet dimensions (W x D x H) 510 x 1360 x 500 mm
- Operating manual, electrical diagrams, CE declaration
The furnace is offered as a refurbished unit. Electrically tested including measurement reports.
Inspection in our warehouse by appointment!
The furnace is not suitable for gas nitriding with NH2/ammonia!
Blsdjyxlwrepfx Adrei
Furnace, furnaces, industrial furnace, melting furnace, annealing furnace, heat treatment furnace, sintering furnace, protective gas furnace, tempering furnace, hardening furnace, chamber furnace, brazing furnace, debinding furnace, de-waxing furnace, stress-relieving furnace, vacuum furnace, protective gas furnace.
Listing
Borken
18,513 km
Temperature chamber
WEISSWT11-1000/40
Call
Condition: excellent (used), Weiss Temperature Chamber
Here we offer a Weiss temperature chamber.
Weiss temperature chamber, air-cooled, with Weiss condenser cooler
Test chamber volume approx. 990 liters
Data for temperature tests:
Temperature range -40°C to +180°C
Temporal temperature deviation in the center of the usable space ± 0.1 to ± 0.5 K
Blsdpfx Aezfzamjdroi
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature gradient (according to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating 4 K/min
Cooling 3 K/min
Heat compensation max. 4500 W
Feedthrough, installed as standard
R1: NW 125 mm
L1: NW 50 m
Dimensions:
Test chamber dimensions: Width 1100 mm x Depth 950 mm x Height 950 mm
Housing dimensions: Width 1390 mm x Depth 1525 mm x Height 1995 mm
Maximum load (evenly distributed over the area) of the test chamber floor 150 kg
Per insert shelf 50 kg
Total load of the shelf supports 100 kg
Data for operation:
Test chamber lighting: Halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 11.5 kW
Rated current 22 A
Heat dissipation water-cooled test cabinets max. heat dissipation to the environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: (converted to R-452a)
Weight: approx. 840 kg
Type: WT11-1000/40
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data and information are subject to change!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature chamber
WEISSWT11-1000/70/5
Call
Condition: excellent (used), Weiss Temperature Chamber
We offer a Weiss temperature chamber here.
Weiss temperature chamber, air-cooled with Weiss condenser cooler
Test chamber volume approx. 990 liters
Data for temperature tests:
Temperature range -70°C to +180°C
Temporal temperature deviation in the center of the useful space ± 0.1 to ± 0.5 K
Spatial temperature deviation ± 0.5 to ± 2.0 K
Temperature gradient (according to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating 5 K/min
Cooling 5 K/min
Heat compensation max. 2750 W
Feedthrough integrated in the standard configuration
R1: NW 125 mm
L1: NW 50 m
Dimensions:
Test chamber dimensions: Width 1100 mm x Depth 950 mm x Height 950 mm
Housing dimensions: Width 1390 mm x Depth 1525 mm x Height 1995 mm
Bedpjzfy Rwjfx Adroli
Maximum load (evenly distributed over the area) of the test chamber floor 150 kg
per insert shelf 50 kg
Total load of the shelf supports 100 kg
Data for operation:
Test chamber lighting Halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 27.0 kW
Rated current 42.02 A
Heat dissipation of water-cooled test cabinets max. heat dissipation to the environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: (converted to R-452a)
Weight: approx. 960 kg
Type: WT11-1000/70/5
For your security as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have on the telephone.
Listing
Borken
18,513 km
Stress test chamber
EspecEHS-221MD
Call
Condition: excellent (used), Espec
Here we offer an Espec (ThermoTec) stress test chamber.
External dimensions: W x H x D: 860 x 1795 x 1000 mm
Test chamber dimensions: W x H x D: 355 x 355 x 426 mm
2 x 46 liters
Voltage: 230 V 1/N 50 Hz
Rated current: 37 A
Fuses: 250 V, 2 x 3 A
Type: EHS-221MD
Temperature range: +105°C to +142.9°C
Humidity range: 75 to 100% RH
Temperature stability: -+ 0.5 °C
Pressure range: 0 to 2.0 kg/cm²
Heating/pressure build-up time: from 0 to 2.0 kg/cm² in approximately 60 minutes
390 kg
Blsdpfozfy N Tox Adrji
Condition: Used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by phone.
Listing
Borken
18,513 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch Shock Test Chamber
Here we offer you a Vötsch shock test chamber.
Water-cooled
Temperature range: -80°C to +220°C
Warm chamber: +50 to +220
Intermediate chamber: -10 to +90
Cold chamber: -80 to +70
Supply voltage: 400V ±10% 3/N 50Hz
Rated current: 30.5 A
Rated power: 13.5 kW
Refrigerant VK: R 404A 3.00 kg p*: 25 bar
Bledpfx Ajzd Uzusdrsi
Refrigerant TK: R23 15 bar p*: 25 bar
Condition: used
Type: VT 7012 S3
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
18,513 km
Stress test chamber
EspecEHS-221M
Call
Condition: excellent (used), Espec
We are offering an Espec (ThermoTec) stress test chamber.
Overpressure and humidity tests at over 100 degrees Celsius in various modes.
Program capacity for 10 samples with 30 steps per sample.
A variety of safety mechanisms: overheating/overpressure protection, detection of water supply failure, complete door locking, and temperature sensor.
Saturated temperature range: 105 to 142.9°C.
Unsaturated temperature range: 105 to 132.9°C.
Humidity range: 50 to 100% RH.
Bsdpfx Aozd Uy Djdroli
Nominal pressure: 0.196 MPa at 132.9°C and 100% RH.
External dimensions: Width 740 x Height 1553 x Depth 1000 mm.
Test chamber dimensions: Width 355 x Height 355 x Depth 426 mm.
Other features:
With rails and grid.
Test item connections inside the chamber.
Type: EHS-221M
Scope of delivery: See images.
300 kg
Condition: Used
Scope of delivery: (See image)
(Changes and errors in the technical data and specifications are reserved!)
We would be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Climate test chamber with humidity
WeissSB2/500/80 -75°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss climate test chamber.
Designation: SB2/500/80, water-cooled
Cold-heat operation: -75°C ... +180°C
Climate operation: +10...+95°C
Humidity range: 10...98 % RH
Temperature stability, over time: ± 0.2K
Humidity stability: ±1 % RH
Temperature change rate:
Cooling: approx. 1.4 K/min
Heating: approx. 2.5 K/min
External dimensions: Height 1980 mm, Width 1265 mm, Depth 1365 mm
Connections:
left side: ∅ 100 mm
right side: ∅ 50 mm
The connection voltage is:
400V/3Ph+N+PE/50 Hz
Power: 10.4 kVA
Weight: approx. 720 kg
Refrigerant: R404a / R23
For your security as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
Bedpfszd Ultox Adrsli
2. Refilling with legally compliant refrigerant
3. Leakage test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Type: SB2/500/80
Condition: used
Scope of delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We will gladly answer any further questions you may have over the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
18,513 km
Emissions test chamber
WEISSWT 5,1'/ + 18-45
Call
Condition: excellent (used), Weiss
Here, we offer a Weiss emission test chamber.
Mini - SHED for diurnal loss measurements
Test chamber dimensions: Width 1600 mm x Depth 2140 mm x Height 2150 (usable 1600) mm
Housing dimensions: Width 1760 mm x Depth 3100 mm x Height 2790 mm
Maximum floor load: 250 kg
Operating temperature range: +18 °C ... +45 °C (at higher temperatures, SHED operation is only possible without a Tedlar bag)
Temperature range: +18 °C ... +45 °C
Temperature stability: ≤ ±1 K (over time)
Bodpfx Aozd Slkjdrjli
Temperature change rate (heating and cooling): approx. 0.5 K/min, without test specimen
Duct connection (air inlet and outlet): ∅ 80 mm, in the rear wall of the chamber
Shut-off valve, gas-tight (air inlet and outlet): ∅ 80 mm, gas-tight, pneumatic operation; scope of supply: connecting flange of the shut-off valve
Cooling water consumption: approx. 0.8 m3/h
Voltage: 230/400 V; 3-phase + N + PE; 50 Hz
Rated power: 4.1 kW Rated current: 14.0 A
Weight: approx. 2500 kg
Type: WT 5.1'/ + 18-45
Condition: used
Sale from our location
Scope of supply: (Only the Weiss emission test chamber WT 5.1'/ + 18-45 Mini-SHED)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
18,513 km
Climatic test chamber
Feutron3702/06
Call
Condition: excellent (used), Feutron
Type: 3702/06
Water-cooled climate test chamber
Technical data:
Nominal volume of test chamber: 2.0 m³
Dimensions: Test chamber exterior, with humidifier console
Width: 2970 mm, Height: 2370 mm, Depth: 1530 mm
Rear wall
Minimum insertion dimensions: Width: 2970 mm, Height: 2390 mm, Depth: 1550 mm
Test chamber: Width: 2000 mm, Height: 1000 mm, Depth: 1000 mm
Door: double-leaf, clear opening width 2000 mm, height 1000 mm
Viewing window, heated, 2 pieces, width 500 mm, height 600 mm
Feed-through opening, 1 piece, left side wall, diameter 75 mm
Temperature range: -40...100°C
Climate range: 10...95°C
Temperature difference, time-dependent ≤ ± 0.5...± 1.0 ΔN/K
Rate of change measured in the supply air, without load
Cooling up to 2.0 on average K/min
Heating up to 2.0 on average K/min
Humidity range: 10...95 % RH
Humidity difference, time-dependent ≤ ± 3.0 % RH
Dew point range, intermittently up to -5...95°C
Refrigeration system: water-cooled, semi-hermetic Bitzer system
Refrigerant: R507 (Μ-Κ1)
Climate and dryer refrigeration system: air-cooled / hermetic system
Refrigerant: R134a (Μ.ΚΚ)
Power supply:
Electrical connection: 400V 3/N/PE.AC, 50Hz
Power plug: CEE 5-pin, 32 A, with 5.0 m cable
Max. simultaneous power requirement: 10.0 kW
Supply line fuse: 3x 25, Char, C A
Protection class: IP20
Weight: 1300 kg
Condition: used
Bjdpfxszd Sdmj Adreli
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Climate test chamber with humidity control
Feutron3707/06 Temp. -40°C bis 150°C
Call
Condition: excellent (used), Here we offer a Feutron climate test chamber.
Feutron Climate Test Chamber
Temperature
Blsdozd Sdgopfx Adrji
Temperature range: -40...90°C
Climatic range (without heat load): 10...85°C
Temporal temperature deviation during temperature operation: ≤ ± 0.5 K/min
Temporal temperature deviation during climatic operation: ± 1.0... ± 1.5 K/min
Change rates
Heating: avg. 2.0 K/min
Cooling: avg. 2.0 K/min
Standard IEC 1646 is achievable with testing, solar modules up to max. 160kg weight and nonlinear ramps (setpoint jump)
Drying
Air drying: condensation drying
Humidity
Air humidification: steam humidification
Humidity range: 10...95 % r.h.
Temporal humidity deviation: ≤ ± 3.0... ±5.0 % r.h.
Dew point range: 8...80.9°C
Test Chamber
Test chamber volume: 7.0 m³
Dimensions
Internal dimensions: Width 1500 mm x Height 2250 mm x Depth 2000 mm
Swing door DIN right, heated, Width 900 mm x Height 2100 mm
Observation window, heated, with blackout shutter and lockable: Width 500 mm x Height 600 mm
Feedthrough: 2x, right front side, Ø 75 mm
Irradiation unit, test chamber
Opening: 4x in left side wall for SC 2500, each 850 x 700 mm
Irradiated area when using SC 2500: 1200 x 1200 mm
Radiation intensity at 1.0 m wall distance: 1000 ± 10% W/m²
Lighting: 1x halogen lamp, 200W
Refrigeration system: Bitzer compressor, semi-hermetic, 2-stage, air cooled
Condenser: split condenser (outdoor installation, winter control)
Refrigerant: R507 / R23
Temperature control system
Coolant medium Tyfocor / water
Mixing ratio 50/50%
Coolant density: 1.072 kg/dm³
Filling quantity: approx. 80 dm³
Pyranometer
Temperature range: -40...150°C
Max. radiation absorption: 4000 W/m²
Spectral range (50% points): 305...2800 nm
Sensitivity (nominal): 7 µV/W/m²
Power supply, test chamber
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type: hardwired
Max. simultaneous power demand: approx. 32.0 kW
Supply fuse: 3 x 63, Char C (A)
Power supply, SolarConstant
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type:
Max. simultaneous power demand: approx. 30.0 kW
Supply fuse: 3 x 63, Char C (A)
Overall external dimensions of the test cell including: equipment room/control cabinet and control cabinet for SolarConstant 2500
External dimensions equipment room: Width 3440 mm x Height 2580 mm x Depth 2950 mm
/control cabinet: Width 2200 mm x Height 1830 mm x Depth 1100 mm
External dimensions condenser, split: Width 900 mm x Height 950 mm x Depth 2000 mm
Weight test chamber (total): approx. 2700 kg
Condenser empty weight: 153 kg
Weight: 2700 kg
Type: 3707/06
Condition: used
Scope of delivery: (see picture)
(Technical data and information are subject to change and errors!)
For further questions, we are happy to assist you by phone.
Listing
Borken
18,513 km
Shock test chamber
HeraeusHT 7012 S2
Call
Condition: excellent (used), Here, we offer a shock test chamber.
Water-cooled temperature shock test chamber
Blodpfszd R Uwox Adrji
Two-chamber design
Warm chamber:
Temperature control in the warm chamber ranges from +50°C to +220°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate:
Heating: 11 K/min
Cold chamber:
Temperature control in the cold chamber ranges from -65°C to +70°C
Temporal temperature deviation in the center of the usable space: ± 1 K
Spatial temperature deviation: ± 2 K
Temperature change rate:
Heating: 2 K/min
Cooling: 3 K/min
Test chamber volume: 125 liters
Temperature range, warm chamber: +50°C to +220°C
Temperature range, cold chamber: -65°C to +70°C
Test chamber dimensions: Width 470mm, Depth 650mm, Height 410mm
External dimensions: Width 930mm, Depth 2115mm, Height 1970+mm
Rated power: 10 kW
Rated current: 25 A
Voltage: 3/N/PE AC 400V +6/-10% 50Hz
Refrigerant: R404A / R23
Operating hours: 27,903 hours
Weight: 1000 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated instruments.
Type: HT 7012 S2
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data are subject to change!)
We are happy to answer any further questions you may have by phone.
We make it easier for you to find: "temperature test chamber -20°c...+140°c"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month











































































































































































































































