Used Vötsch Vötsch Vc7034 for sale (85)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Wald
18,661 km
Climate test chamber, climatic chamber
VötschVCL 4003
Call
Condition: ready for operation (used), Vötsch VCL 4003 Climate Chamber
Test chamber volume: 34 liters
Weight: 110 kg
Rated power: 1.8 kW
Temperature range: -40 to +180 °C
For further technical data, please refer to the images.
We were unable to carry out a full test of the device, as the touch screen switches off after a certain period.
The device likely requires new software.
For this reason, the device is being sold as defective.
You are welcome to arrange an inspection appointment.
We can also organize affordable shipping for you!
You will receive a proper invoice.
Ijdexw Srqopfx Aqujic
Net invoices can be issued for foreign customers, provided you supply a valid VAT ID.
Subject to prior sale.
Visit our shop to see our other listings as well.
The company names and trademarks mentioned are the property of their respective owners and are used solely for identification and description purposes.
Deviations from technical data as well as errors in the item description may occur and are reserved.
Listing
Borken
18,517 km
Vötsch climatic test chamber Fitotron HGC1014
Vötsch Klimaprüfschrank 5°C bis +45°Fitotron HGC 1014 V Schrank 3 mit Bel.
Call
Condition: excellent (used), functionality: fully functional, Year of construction: 2012, Fitotron® Modular Plant Growth Chambers, Type HGC 1014 V, including HQI-T and Krypton Lighting Module
Temperature range +5°C - +45°C for temperature testing
Test chamber volume approx. 1300 l
Simpac Control System
Network Connection
USB Connection
The Fitotron® HGC series plant growth chambers are based on a modular design. Individual modules can be added or replaced as needed. This allows them to be adapted to different applications. They are suitable for plants with high light requirements, such as wheat, corn, cotton, rice, and C4 plants.
Lighting HQI-BT-400 W/D and 100 W,
Temperature range +5°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% RH approx. 0.8 kW
Characteristics for climatic tests with irradiation
Temperature range +10°C to +45°C with light on +10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Humidification and dehumidification system, stainless steel test chamber
Internal dimensions: Height 1400 mm, Depth 750 mm, Width 1270 mm
External dimensions: Height 1985 mm, Depth 980 mm, Width 2320 mm
Ijdpfevz U Erex Aqusic
External dimensions with lighting module: Height 2450 mm
Single door with observation window
Interface for computer connection
Connection 3/N/PE 400V ±10% 50Hz
CE marking, mobile, very good condition
Pipe penetration ∅ 50 mm
Air cooling
Refrigerant R404A
Weight approx. 480 kg + 130 kg lighting module
Listing
Borken
18,513 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch Type: VTS 7018-5 Heraeus Vötsch Temperature Test Chamber, Water-Cooled Temperature range: -70°C to +180°C Temporal temperature deviation: ± 0.1 to ± 0.5 K Spatial temperature deviation: ± 0.5 to ± 2.0 K Temperature change rate (cooling): 6.5 K/min Temperature change rate (heating): 7.5 K/min Heat compensation: 4,500 W Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm External dimensions: Width 870 mm x Depth 1,280 mm x Height 1,575 mm Viewing window: Width 300 mm x Height 540 mm Test chamber volume: 190 liters Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz Rated power: 10 kW Rated current: 21 A Supply-side fuse: 32 A slow-blow Sound level at 1 m distance (free-field measurement): < 63 dB(A) Lateral port: 50 cm / 125 cm Chamber is water-cooled Refrigerants: R452A and R23 Weight: approx. 460 kg Important safety information for buyers: The following procedures are carried out on all chambers offered by us: 1. Functional check and replacement of necessary components 2. If required, refilling with legally compliant refrigerant 3. Leak test with certificate 4. After successful inspection, all chambers are subjected to a documented trial run. Condition: used Scope of delivery: (see photos) (Technical data and specifications subject to change and errors!) If you have further questions, we are happy to provide information by phone.
Ijdpsyu Rhgefx Aqusic

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
18,517 km
Control system
Vötsch Pflanzenwuchsschrank -10 bis +45Fitotron HGC 1014 V Schrank 1
Call
Condition: excellent (used), Year of construction: 2012, functionality: fully functional, Fitotron® Modular Plant Growth Chambers, Type HGC 1014 V, including HQI-T and Krypton Lighting Module
Temperature range -10°C - +45°C for temperature testing
Test chamber volume approx. 1300 l
Simpac Control System
Network Connection
USB Connection
The Fitotron® HGC series plant growth chambers are based on a modular design. Individual modules can be added or replaced as needed. This allows them to be adapted to different applications. They are suitable for plants with high light requirements, such as wheat, corn, cotton, rice, and C4 plants.
Lighting HQI-BT-400 W/D and 100 W,
Temperature range -10°C to +45°C
Temperature deviation over time ± 0.5 K
Iisdpfx Aov Ivnzjquec
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% RH approx. 0.8 kW
Characteristics for climatic tests with irradiation
Temperature range +10°C to +45°C with light on +10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Humidification and dehumidification system, stainless steel test chamber
Internal dimensions: Height 1400 mm, Depth 750 mm, Width 1270 mm
External dimensions: Height 1985 mm, Depth 980 mm, Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single door with observation window
Interface for computer connection
Connection 3/N/PE 400V ±10% 50Hz
CE marking, mobile, very good condition
Pipe penetration ∅ 50 mm
Air cooling
Refrigerant R404A
Weight approx. 480 kg + 130 kg lighting module
Listing
Borken
18,517 km
Control system
Vötsch Pflanzenwuchsschrank -10 bis +45Fitotron HGC 1014 V Schrank 4
Call
Condition: excellent (used), Year of construction: 2012, functionality: fully functional, Fitotron® Modular Plant Growth Chambers, Type HGC 1014 V, including HQI-T and Krypton Lighting Module
Temperature range -10°C - +45°C for temperature testing
Test chamber volume approx. 1300 l
Simpac Control System
Network Connection
USB Connection
The Fitotron® HGC series plant growth chambers are based on a modular design. Individual modules can be added or replaced as needed. This allows them to be adapted to different applications. They are suitable for plants with high light requirements, such as wheat, corn, cotton, rice, and C4 plants.
Isdpfxov Ivn Us Aqusic
Lighting HQI-BT-400 W/D and 100 W,
Temperature range -10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% RH approx. 0.8 kW
Characteristics for climatic tests with irradiation
Temperature range +10°C to +45°C with light on +10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Humidification and dehumidification system, stainless steel test chamber
Internal dimensions: Height 1400 mm, Depth 750 mm, Width 1270 mm
External dimensions: Height 1985 mm, Depth 980 mm, Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single door with observation window
Interface for computer connection
Connection 3/N/PE 400V ±10% 50Hz
CE marking, mobile, very good condition
Pipe penetration ∅ 50 mm
Air cooling
Refrigerant R404A
Weight approx. 480 kg + 130 kg lighting module
Listing
Borken
18,517 km
Plant growth cabinet Fitotron HGC 1014
Vötsch Pflanzenwuchsschrank -10 bis +45Fitotron HGC 1014 V Schrank 2
Call
Condition: excellent (used), functionality: fully functional, Year of construction: 2012, Fitotron® Modular Plant Growth Chambers, Type HGC 1014 V, including HQI-T and Krypton Lighting Module
Temperature range -10°C - +45°C for temperature testing
Test chamber volume approx. 1300 l
Simpac Control System
Network Connection
USB Connection
The Fitotron® HGC series plant growth chambers are based on a modular design. Individual modules can be added or replaced as needed. This allows them to be adapted to different applications. They are suitable for plants with high light requirements, such as wheat, corn, cotton, rice, and C4 plants.
Lighting HQI-BT-400 W/D and 100 W,
Temperature range -10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Humidity deviation over time ± 3 to 5% RH
Fresh air up to 7.5 m³/h
Power consumption without fresh air operation at 25°C / 75% RH approx. 0.8 kW
Characteristics for climatic tests with irradiation
Temperature range +10°C to +45°C with light on +10°C to +45°C
Temperature deviation over time ± 0.5 K
Humidity range 40% to 95%
Dew point range +4°C to +35°C
Isdpfxov Ivn Is Aquoic
Humidity deviation over time ± 3 to 5% RH
Humidification and dehumidification system, stainless steel test chamber
Internal dimensions: Height 1400 mm, Depth 750 mm, Width 1270 mm
External dimensions: Height 1985 mm, Depth 980 mm, Width 2320 mm
External dimensions with lighting module: Height 2450 mm
Single door with observation window
Interface for computer connection
Connection 3/N/PE 400V ±10% 50Hz
CE marking, mobile, very good condition
Pipe penetration ∅ 50 mm
Air cooling
Refrigerant R404A
Weight approx. 480 kg + 130 kg lighting module
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
With temperature change rate of 5 K/min
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Ijdpjygvn Nefx Aquoic
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Refrigerant: R404A / R-23
Weight approx. 570 kg
For your security as a buyer, please note the following:
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.
Listing
Borken
18,513 km
Temperature test chamber 990 liters
VötschVT³ 4100 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VT³ 4100
Water-Cooled Temperature Test Chamber
S!MCON/32.NET (with Touch Panel)
Control System Features:
- Color touchscreen with intuitive menu navigation (typically 5.7" or larger)
- Programming of temperature/humidity profiles with ramps and dwell times
- Data acquisition & logging (e.g., temperature profile, alarms)
- USB port for data export (CSV, optionally S!MPATI compatible)
- Network interface (Ethernet) for remote monitoring and control
- User management with password protection
- Interfaces: Volt-free contacts, optionally Modbus or Profibus
VT³ 4100 – Technical Specifications (Temperature Test Chamber)
- Test volume: 990 liters
- Temperature range: -40 °C to +180 °C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature deviation: ±0.5 to ±1.5 K
- Temperature gradient: 1 to 3 K
- Temperature change rate (per IEC 60068-3-5):
• Heating: 4.0 K/min
• Cooling: 3.0 K/min
- Maximum heat compensation capacity: 4500 W
- Calibration values: +23 °C and +80 °C
- Internal dimensions (W×D×H): 1100 × 950 × 950 mm
- External dimensions (W×D×H): 1390 × 1955 × 1995 mm
Feed-Throughs:
The chamber is equipped with feed-throughs on both the right and left sides, allowing insertion of measuring cables and test devices into the test space.
• 1 × L1 nominal width 50 mm
• 1 × R1 nominal width 125 mm
• 3 × R1 nominal width 50 mm
Electrical connection: 3/N/PE AC, 400V ±10%, 50Hz
Power consumption: 11.5 kW
Rated current: 22 A
Noise level: approx. 62 dB(A)
Refrigerant: R452A
Weight: 920 kg
Important information for buyers:
For your security, the following measures are carried out on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant, if needed
Iodpfx Aqjygvm Ejueic
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data; information may be subject to alteration!)
For any further questions, feel free to contact us by phone.
Listing
Borken
18,513 km
Climatic chamber
VötschVC³ 4100
Call
Condition: excellent (used), Vötsch Climate Test Chamber
We offer a Vötsch climate test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
External dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Feed-throughs: Ø 125 mm, Ø 50 mm
Specifications for temperature tests:
- Temperature range: -42°C to +180°C
- Temporal temperature deviation: ±0.1 to ±0.5 K
- Spatial temperature uniformity: ±0.5 to ±1.5 K
- Temperature change rates:
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
- Maximum heat compensation at +20°C: 4500 W
Specifications for climate tests:
- Temperature range: +10°C to +95°C
- Dew point range: -3°C to +94°C
- Humidity range: 10 to 98% r.H.
- Temporal temperature deviation: ±0.1 to ±0.3 K
- Spatial temperature uniformity: ±0.5 to ±1.0 K
- Temporal humidity deviation: ±1 to ±3% r.H.
Iisdpfx Aqsyguw Neusc
- Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 11.5 kW
Nominal current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
Important buyer information:
The following procedures are carried out on all our chambers prior to sale:
1. Functional checks and replacement of necessary components
2. If required, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (See picture)
(Technical data subject to change and errors excepted!)
For further questions, please feel free to contact us by phone.
Listing
Borken
18,513 km
Temperature test chamber
VötschVT³ 4150/S
Call
Condition: excellent (used), Vötsch
Model: VT³ 4150/S
Vötsch Temperature Test Chamber
Water-cooled
Rated voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated power: 11.5 kW; Rated current: 22.0 A
Change rate (cooling): approx. 3.5 K/min
Change rate (heating): approx. 4 K/min
Temperature testing
Temperature range: -40°C to +180°C
Layout drawing
External dimensions (W x D x H): approx. 1390 x 2380 x 1995 mm
Test chamber dimensions (W x D x H): approx. 1100 x 1475 x 950 mm
Weight: approx. 1020 kg / 1540 liters
Refrigerant: R 404A
Iodpfx Aqjyguuzoueic
For your safety as the buyer, please note the following information!
The following items are carried out on all chambers offered by us:
1. Functional inspection and replacement of necessary components
2. If needed, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see photo)
(Technical data and information subject to change and errors excepted!)
We are happy to answer further questions by telephone.
Listing
Borken
18,513 km
Climate test chamber with humidity
VötschVC³ 0100 0°C bis + 90°C
Call
Condition: excellent (used), Vötsch
Type: VC³ 0100
Vötsch Climate Test Chamber, Air-Cooled
Internal Test Chamber Dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall Device Dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Test Chamber Volume: 990 litres
Temperature Testing:
Minimum Temperature: -0°C
Iedoygut Rjpfx Aqusic
Maximum Temperature: +90°C
Temperature Change Rate, Cooling: 0.2 K/min
Temperature Change Rate, Heating: 0.5 K/min
Temporal Temperature Deviation: ±0.1 to ±0.5 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Heat Compensation at +20 °C: 350 W
Climatic Testing:
Minimum Temperature: +10°C
Maximum Temperature: +90°C
Dew Point Temperature Range: +4°C to +89.5°C
Humidity Range: 10 to 98% r.h.
Temporal Humidity Deviation: ±1 to ±3% r.h.
Temporal Temperature Deviation: ±0.1 to ±0.3 K
Spatial Temperature Uniformity: ±0.5 to ±1.0 K
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated Power: 2.3 kW
Rated Current: 10 A
Refrigerant: R-404A
Weight: approx. 1400 kg
Important information for you as a buyer:
The following measures are carried out on our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certification
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see image)
(Specifications and technical details are subject to change and error!)
For further questions, we are happy to assist you by phone.
Listing
Borken
18,513 km
Climate test chamber with humidity
VötschVC³ 4100 990 Liter -42°C bis +180°C
Call
Condition: excellent (used), Here we offer a Vötsch climatic test chamber.
Model: VC³ 4100, air-cooled
With a temperature change rate of 3 K/min
Test chamber internal dimensions: Height 950 mm x Width 1100 mm x Depth 950 mm
Overall unit dimensions: Height 2000 mm x Width 1300 mm x Depth 1916 mm
Chamber volume: 990 liters
Port openings: Ø 125 mm, Ø 50 mm
Temperature test specifications:
Temperature range: -42°C to +180°C
Ijdjygutwepfx Aqujic
Temporal temperature deviation: ± 0.1 to ± 0.5 K
Spatial temperature uniformity: ± 0.5 to ± 1.5 K
Temperature change rate:
Heating: 4.0 K/min
Cooling: 3.0 K/min
Max. heat compensation at +20°C: 4500 watts
Climatic test specifications:
Temperature range: +10°C to +95°C
Dew point range: -3°C to +94°C
Humidity range: 10 to 98% r.h.
Temporal temperature deviation: ± 0.1 to ± 0.3 K
Spatial temperature uniformity: ± 0.5 to ± 1.0 K
Temporal humidity deviation: ± 1% to ± 3% r.h.
Max. heat compensation: 500 W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 11.5 kW
Rated current: 22.0 A
Refrigerant: R-404A
Weight: approx. 840 kg
Type: VC³ 4100
For your security as a buyer, please note the following information!
The following points are checked and carried out on all our chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. If needed, fresh filling with legally compliant refrigerant
3. Leak check with certificate
4. After a successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Subject to prior sale, changes and errors in technical data and specifications reserved!)
We are happy to answer any further questions by phone.
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
Iiedpfoygur Tox Aquoc
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Borken
18,513 km
Temperature test chamber
VötschVTR 7033/S
Call
Condition: good (used), Year of construction: 1996, Vötsch VTR 7033/S Temperature test chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item no.: 60885637
Temperature chamber
Temp. range: -70°C to +180°C
Mains voltage:400V
Rated current:24A
Rated output: 9.5 kW
Refrigerant VK: R 404 A
Refrigerant TK: R 23
Year of manufacture: 1996
TK 07
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Iiodpfxowbpzmo Aquec
You will find further articles - new and used - in our store!
International shipping costs on request!
Listing
Borken
18,513 km
Temperature shock test chamber
VötschVT 7030 S2
Call
Condition: good (used), Year of construction: 1998, Vötsch VT 7030 S2 Temperature Shock Test Chamber -80 °C to +220 °C
The Vötsch VT 7030 S2 Environmental Test Chamber is designed for laboratory applications that require testing of materials and components in a known environment. With its versatile capabilities and easy-to-use controls, this programmable unit can be used to simulate a variety of environmental conditions for scientific studies, product testing and process control.
Data for temperature tests in single chamber operation
Hot chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range +50 °C to +220 °C
Temperature deviation in time in the center of the chamber ± 1 K
Temperature deviation in space ± 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 11 K/min
Cold chamber:
Temperature shock test chamber Test chamber 300 l
Temperature range -80 °C to +70 °C
Temperature deviation in time in the middle of the usable space ± 1 K
Temperature deviation in space 2 K
Temperature gradient (according to IEC 60068-3-5) 4 K
Rate of temperature change (according to IEC 60068-3-5, measured in supply air)
Heating 1.5 K/min
Cooling 4K/min
Technical data:
Temperature shock test chamber
Test chamber volume approx. 300 l
Voltage: 3/N/PE AC 400 V ± 10 % , 50 Hz
Rated power: 30 kW
Rated power: 50 A
Refrigerant: R-404a /R-23
Iodpfjwbdv Ssx Aqueic
Chiller: Water-cooled
Weight: approx. 940 kg
Year of construction. 1998
Test room dimensions: Width 770 mm x depth 650 mm x height 610 mm
Housing dimensions: Width 1200 mm x depth 1800 mm x height 2050 mm
TS 05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items - new and used - can be found in our store!
International shipping costs on request!
Listing
Borken
18,513 km
Temperature test chamber
VötschVT 7100
Call
Condition: excellent (used), Heraeus Vötsch VT 7100 Temperature test chamber -70°C to +180°C
Ijdpfx Aeph Uzxsqusic
Heraeus Vötsch
Temperature test chamber
VT 7100
-70°C to +180°C
1035 liters
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further articles - new and used - you will find in our store!
International shipping costs on request!
Listing
Borken
18,513 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1998, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Iedpfouuin Rjx Aqujic
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Year of Manufacture: 1998
TK 09
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVCS 7100
Call
Condition: good (used), Vötsch VCS 7100 Climatic Test Chamber -70°C to +180°C
Manufacturer: Vötsch
Type: VCS 7100
Temp. Range: -70°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Rated Power: 11 kW
Refrigerant: R404A
Height: 1980 mm
Width: 1350 mm
Depth: 2060 mm
Chamber:
Height: 900 mm
Width: 970 mm
Depth: 1400 mm
KK-05
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Iiodpfx Aqeuuix Neuoc
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Temperature shock test chamber -70-220°C
VötschVT 7012 S2
Call
Year of construction: 2000, operating hours: 104,382 h, condition: excellent (used), Vötsch Shock Test Chamber VT 7012 S2
System for extreme temperature cycling
Temperature shock testing is used to test the resistance of components, devices, and other products to rapid changes in ambient temperature.
The test specimens are subjected to rapid temperature changes in air with alternating upper and lower temperature loads.
These cyclical stresses and the accelerated aging caused by temperature changes reveal weaknesses in the test specimen.
Vertical arrangement of the test chambers
Ball screw drive for safe guidance of the car
Cart load capacity 50 kg for VT3 7012 S2
All-around grilles in the car secure the test specimens
High air circulation rate, short temperature change times, and uniform temperature distribution in the test chamber
Hot chamber can be used as a temperature storage unit, cold chamber as a temperature exchange unit
Minimal energy consumption
No compressed air required
Manufacturer: Vötsch
Type: VT 7012 S2
Type: Temperature shock test chamber
Test chamber volume: 120 l
Nominal voltage: 400 V
Nominal power: 10 kW
Nominal current: 25 A
Refrigerant: R452A
Cooling unit: Water-cooled
Shock cooling (nitrogen cooling) via customer-supplied nitrogen
External dimensions
Width: 930 mm
Depth: 2115 mm
Height: 1970 mm
Test chamber dimensions
Iiodpfjx Exmtex Aquec
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class
Device: IP 42
Operating panel: IP 20
Control cabinet: IP 54
Temperature test parameters for single-chamber operation |
Test chamber dimensions
Width: 470 mm
Depth: 650 mm
Height: 410 mm
Protection class ...Temperatur Temperature range
Hot chamber: +50°C to +220°C
Cold chamber: -70°C to +70°C
Temperature deviation over time: ±2 K
in steady state
Temperature deviation over space: ±2 K
in steady state in the car
Heating rate, hot chamber: 11 K/min
Cooling rate, cold chamber: K/min
Heating rate, cold chamber: 2 K/min
Cooling rate, hot chamber: K/min
Observation window: 355 x 355 mm
Pipe opening: 67 mm
Year of manufacture: 2000
Operating hours: 104,382
Weight: 1000 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Further items – new and used – can be found in our shop! International shipping costs on request!
Listing
Borken
18,513 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1997, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Isdpjuuiv Iofx Aqujic
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Year of Manufacture: 1997
TK 08
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVCS 4100
Call
Condition: good (used), Vötsch VCS 4100 Climatic Test Chamber -40°C to +180°C
Manufacturer: Vötsch
Type: VCS 4100
Temp. Range: -40°C to +180°C
Line Voltage: 400 V
Rated Current: 17 A
Rated Power: 11 kW
Refrigerant: R404A
Ijdpfjuuiygex Aqujic
KK-07
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
18,513 km
Climate test chamber Temperature test
Heraeus VötschHC 4055
Call
Condition: good (used), Heraeus Vötsch HC 4055 Temperature Test Chamber
Manufacturer: Heraeus Vötsch
Type: HC 44055
Temperature Chamber
Temperature Range: +180°C
Rated Voltage: 380V, +-10%, 3/N, 50Hz
Rated Current: 13.5 A
Rated Power: 9 kW
Housing Dimensions: W 1065 x D 1560 x H 1890 (mm)
Observation Window: Width x Height 350 x 640 mm
Test Chamber: (L x D x H) approx. 800 x 795 x 855 mm
Test Chamber Volume: 550 l
Cabinet is air-cooled
Caution
Cabinet can only be operated as an oven.
Refrigeration circuit empty and shut down.
Air conditioning system shut down.
Isdpeuuilvofx Aquoic
Disconnected contactors:
03K2 Compressor
03K5 Condenser fan
15K6 Panel heater
Solid state relay 21V4 Humidifier.
Weight approx. 550 kg
Financing through our bank is also possible.
komplett-konzept.leasingo.de
More items - new and used - can be found in our shop!
International shipping costs on request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVTSR 7034/S
Call
Year of construction: 2002, condition: good (used), Vötsch VTSR 7034/S Climatic Test Chamber -70 to +180°C
Iedpfx Aeuuif Njquoic
Manufacturer: Vötsch
Type: VTSR 7034/S
Test Chamber Capacity: 335 liters
Climatic Test Chamber
Temp. Range: -70 to +180°C
Line Voltage: 3/N/PE AC, 400 V ±10%, 50 Hz
Rated Current: 22 A
Rated Power: 12.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Year of Manufacture: 2002
TK-11
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
18,513 km
Walk-in climate test chamber
VötschVSKZ 04/120/S
Call
Year of construction: 1996, condition: excellent (used), Vötsch VSKZ 04/120/S Walk-In Climatic Test Chamber
Manufacturer: Vötsch
Type: VSKZ 04/120/S
Temp. Range: -40°C to +120°C
Line Voltage: 400V
Rated Current: 95A
Rated Power: 56 kW
Refrigerant: R 404 A
Year of Manufacture: 1996
External Dimensions: W 2850 x D 4100 x H 3080 mm
SO-01
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Isdpfx Aqjuuigysusic
Find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
18,513 km
Climate test chamber Temperature test
VötschVC 0150
Call
Condition: excellent (used), Vötsch VC 0150 Climatic Test Chamber 0°C - +90°C
Manufacturer: Vötsch
Type: VC 0150
Climatic Test Chamber
Voltage: 230 V
Rated Power: 1.5 kW
Voltage: 1540 liters
Temperature Range: 0°C to +90°C
Humidity: 10% to 98%
Refrigerant: R 134a
Dimensions: W 950 x D 1100 x H 1475 mm
Microprocessor Controller
List Price: €19,500
Isdpfx Aqeuuikfsujic
KK-09
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
We make it easier for you to find: "vötsch vötsch vc7034"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month