Used Thermotron Se-1000-6-6 -70°C Bis + 180°C for sale (94,369)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
18,513 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch Type: VTS 7018-5 Heraeus Vötsch Temperature Test Chamber, Water-Cooled Temperature range: -70°C to +180°C Temporal temperature deviation: ± 0.1 to ± 0.5 K Spatial temperature deviation: ± 0.5 to ± 2.0 K Temperature change rate (cooling): 6.5 K/min Temperature change rate (heating): 7.5 K/min Heat compensation: 4,500 W Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm External dimensions: Width 870 mm x Depth 1,280 mm x Height 1,575 mm Viewing window: Width 300 mm x Height 540 mm Test chamber volume: 190 liters Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz Rated power: 10 kW Rated current: 21 A Supply-side fuse: 32 A slow-blow Sound level at 1 m distance (free-field measurement): < 63 dB(A) Lateral port: 50 cm / 125 cm Chamber is water-cooled Refrigerants: R452A and R23 Weight: approx. 460 kg Important safety information for buyers: The following procedures are carried out on all chambers offered by us: 1. Functional check and replacement of necessary components 2. If required, refilling with legally compliant refrigerant 3. Leak test with certificate 4. After successful inspection, all chambers are subjected to a documented trial run. Condition: used Scope of delivery: (see photos) (Technical data and specifications subject to change and errors!) If you have further questions, we are happy to provide information by phone.
Lasdpfx Anjyu Rhgeujc
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVCS³ 7034-5 -70°C bis +180°C
Call
Condition: excellent (used), Vötsch
Model: VCS³ 7034-5
Vötsch Climate Test Chamber, Water-Cooled
With temperature change rate of 5 K/min
Specifications for temperature testing:
Temperature range: -70°C to +180°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.5 K
Spatial temperature deviation: ±0.5 K to ±2.0 K
Temperature change rate:
Heating: 6.8 K/min
Cooling: 6.7 K/min
Specifications for climate testing:
Temperature range: +10°C to +95°C
Temporal temperature deviation in the center of the usable space: ±0.1 K to ±0.3 K
Spatial temperature deviation: ±0.5 K to ±1.0 K
Temporal humidity deviation in the center of the usable space: ±1% to ±3% RH
Humidity range: 10% to 98% RH
(Extended climate range: 2°C/95% RH regulated for a maximum of 2 hours)
Exterior dimensions (W x D x H): 870 x 1700 x 1775 mm
Test chamber dimensions (W x D x H): 580 x 765 x 750 mm
Test chamber volume: approx. 335 liters
Side ports: 50 mm and 125 mm
Operating data:
LED strip 24 V, 6.8 W / 2 x halogen bulbs 24 V, 50 W
Rated voltage: 3/N/PE AC 400 V ±10%, 50 Hz
Rated power: 9 kW Rated current: 20 A
Customer-side fuse: 63 A slow-blow
Refrigerant: R404A / R-23
Weight approx. 570 kg
Lajdpfxoygvn Nj Anujc
For your security as a buyer, please note the following:
The following procedures are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerant, if needed
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see image)
(Technical data and information subject to change and errors!)
Further questions can be answered by phone.
Listing
Borken
18,513 km
Climate test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Type: VCS 7034-5
Climatic Test Chamber, Water-cooled
Vötsch VCS 7034-5
Test Volume: 335 liters
Lasdpfsygur Tox Anuoc
Specifications for Temperature Testing:
Temperature range: -70 to +180°C
Time-based temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature gradient: 1 to 4 K
Change rate:
Cooling: 6.7 K/min
Heating: 6.8 K/min
Heat compensation at +20°C: 3000 W / at -20°C: 3000 W
Temperature calibration points: +23°C and +80°C
Specifications for Climate Testing:
Temperature range: +10 to +95°C
Time-based temperature deviation: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1.0 K
Temperature gradient: 1 to 2 K
Humidity range: 10 to 98%
Time-based humidity deviation: ±1 to ±3%
Dew point range: -3 to +94°C
Heat compensation: 400 W
Climate calibration points: +23°C / 50% RH and +95°C / 50% RH
Test chamber dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10 kW
Rated current: 21 A
Sound pressure level: 64 dB(A)
Cooling water consumption: 1.4 m³/h
Refrigerants: R452A / R-23
Important safety information for buyers:
The following procedures are carried out on our offered chambers prior to sale:
1. Functional inspection and replacement of necessary components
2. Recharging with legally compliant refrigerant, if required
3. Leak test with certificate
4. After successful testing, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See image)
(Subject to technical modifications and errors. All information is non-binding!)
For further questions, please do not hesitate to contact us by phone.
Listing
Borken
18,513 km
Temperature test chamber 350 liters
CTSTS-70/350 -70°C bis 180°C
Call
Condition: excellent (used), Here we offer you a temperature test chamber.
Water-cooled
Technical specifications:
Temperature operating range
Temperature range in °C: -70 / +180°C
Temperature change rate according to DIN 50 011, Part 12
Cooling rate: approx. 5 K/min
Heating rate: approx. 5 K/min
Dimensions:
Test volume: 350 liters
Test chamber dimensions (approx.): Height 750 mm, Width 650 mm, Depth 720 mm
External dimensions (approx.): Height 1800 mm, Width 850 mm, Depth 1640 mm
Operating data:
Electrical connection: 400 V, 3/N, 50 Hz
Nominal power: 13.3 kW
Refrigerant: R404A / R23
Weight: approx. 650 kg
Type: TS-70/350
Important safety information for buyers:
The following steps are performed on all our offered chambers prior to sale:
1. Functional check and replacement of necessary components
2. Refill with legally compliant refrigerant
3. After successful inspection, the chambers undergo a test run, monitored with calibrated instruments.
Condition: used
Scope of delivery: (see picture)
Lodpeyguprefx Anujac
(Specifications subject to change and error!)
Further questions can be answered by phone.
Listing
Borken
18,513 km
Climatic test chamber 335 liters with humidity
VötschVCS 7034-5 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Vötsch VCS 7034-5
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation temporal K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Lasdsuudx Depfx Anuec
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
Condition: gebraucht / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber 335 liters
Vötsch-70°C bis +180°C VTS 7034-5
Call
Condition: excellent (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50 Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
Lodpfx Anju H U Tweusac
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Climate test chamber with humidity 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Lajdpfjwgaykex Anuoc
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-15 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-15
Vötsch Climate Test Chamber, Water-Cooled
Temperature Test Data:
Temperature range: -70°C to 180°C
Temporal temperature deviation at center of workspace: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 16 K/min
Cooling: 14.5 K/min
Climate Test Data:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temporal temperature deviation at center of workspace: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation at center of workspace: ±1 to ±3% RH
Maximum heat compensation: 8000 W
Enclosure dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Internal dimensions:
Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on both the right and left sides. These allow for test leads and testing devices to be routed into the chamber.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test chamber illumination:
Halogen bulb 24V, 50W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 44.0 kW
Lajdpfswvgwbsx Anujc
Rated current: 63.0 A
Customer-provided fuse: 100 A slow-blow
Maximum heat output to the environment: 2.2 kW
Permissible test item weight:
Total load on shelf supports: 100 kg
Test chamber floor: 150 kg, Removable shelf: 50 kg
Refrigerants: R 404A/R 23
Weight: 1900 kg
For your security as a buyer, please note:
The following steps are carried out in advance on our chambers offered for sale:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in the technical data and specifications!)
We are happy to answer any further questions by phone.
Listing
Geffen
18,585 km
Box body
MitsubishiCanter 7 C 18 Bak + Klep 1000 KG Euro 6
Call
Condition: used, mileage: 125,000 km, power: 132 kW (179.47 HP), fuel type: diesel, fuel: diesel, color: white, gearing type: automatic, emission class: euro6, loading space length: 6,100 mm, loading space width: 2,500 mm, loading space height: 2,370 mm, Year of construction: 2020, Equipment: ABS, air conditioning, central locking, cruise control, electric window regulation, spoiler, tail-lift, Year of manufacture: 2020
Empty weight: 4.358 kg
Carrying capacity: 3.132 kg
GVW: 7.490 kg
Tail lift: tail lift, 1000 kg
= Additional options and accessories =
Lasdpfx Ajyni Ixsnuec
- Airbag
- Beifahrerbank
- Front center armrest
- Outside temperature display
- Radio
- Reversing camera
- Roof spoiler
- Suspension seat
- Tachograph
- Tined glass
- Toolbox
Listing
Borken
18,513 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), Here, we offer a Weiss temperature chamber.
Weiss temperature test chamber with S!MCON / 32 control, air-cooled
(Refrigerant converted to R-452A)
Control panel »Touchpanel«
On the »Touchpanel« control panel, all control and operating commands can be triggered by simply touching the function symbols.
Adjustable feet
To compensate for uneven floors and to ensure sufficient ventilation of the machine part, the test chamber is equipped with adjustable feet.
Feedthroughs
The test chamber is equipped with feedthroughs on the right and left sides.
These allow measuring cables and test equipment to be placed in the test chamber.
Feedthrough installed as standard
R1: 125 mm
L1: 50 mm
Test chamber volume: approx. 600 liters
External dimensions with hinges and door lock
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, Width 1000 mm, Depth 1660 mm
Internal dimensions: Height 950 mm, Width 800 mm, Depth 800 mm
Data for temperature tests:
Temperature range: -42 to +180 °C
Temperature deviation over time in the center of the usable space: ± 0.1 to ± 0.5 K
Temperature deviation spatially: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 4.0 K/min
Cooling: 3.0 K/min
Maximum heat compensation: 2500 W
Data for operation:
Test chamber lighting: halogen bulb 2 x 24V, 50W
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Rated current: 15 A, Rated power 7.8 kW
Fuse, to be provided by the customer: 16 A, slow-blow
Sound pressure level approx.
measured at a distance of 1m from the front, 1m height: 61 dB(A)
Refrigerant: R-452A
Weight: 620 kg
Type: WT3-600/40
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
Ljdpjzga Huofx Anuoac
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
18,513 km
Temperature test chamber 600 liters
Vötsch KlimaprüfschrankVC 4060 -40°C bis +180°C
Call
Condition: excellent (used), Vötsch VC 4060 Climate Testing Chamber
Lasdozf E E Tspfx Anujc
Manufacturer: Vötsch Industrietechnik GmbH
Type: VC 4060
Machine Type: Climate Testing Chamber / Temperature Testing Chamber
Test Chamber Volume: approx. 600 liters
Control System: S!MCON / 32
Cooling: water-cooled
Refrigerant: R452A
For sale is a used climate testing chamber from Vötsch.
The testing chamber is suitable for temperature and climate tests, environmental simulation,
material testing, quality assurance, as well as development and stress tests.
Technical Data
Test Chamber Dimensions: approx. 800 x 800 x 950 mm (W x D x H)
Housing Dimensions: approx. 1090 x 1960 x 1995 mm (W x D x H)
Weight: approx. 600 kg net
Temperature Range: -40 °C to +180 °C
Temperature Change Rate (Heating): approx. 4.0 K/min
Temperature Change Rate (Cooling): approx. 3.0 K/min
Temperature Deviation (Time): ±0.1 to ±0.5 K
Temperature Deviation (Spatial): ±0.5 to ±2 K
Temperature Gradient: approx. 1 to 4 K
Climate Range (Temperature): -10 °C to +95 °C
Humidity Range: 10 % to 98 % RH
Humidity Deviation: ±0.1 to ±3 % RH
Temperature Deviation (Climate Operation, Time): ±0.1 to ±0.3 K
Temperature Deviation (Climate Operation, Spatial): ±0.5 to ±1.0 K
Temperature Gradient (Climate Operation): approx. 1 to 2 K
Power Connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated Power: 7.8 kW
Rated Current: 15.0 A
Fuse: 16 A slow-blow, on-site
1 cable entry Ø 50 mm installed on the left
1 cable entry Ø 125 mm installed on the right
Test chamber made of stainless steel
Touch panel operation
Equipment
S!MCON / 32 control system
Touch panel operation
Interior made of stainless steel
Test chamber lighting
Side cable entries Ø 50 mm and Ø 125 mm
Shelving / test chamber equipment as shown in the pictures
Water-cooled system
Documentation / operating manual
Accessories as shown in the pictures
Application Areas
Temperature testing
Climate testing
Environmental simulation
Material testing
Electronics testing
Quality assurance
Research and development
Scope of Supply
1x Vötsch VC 4060 Climate Testing Chamber
Documentation / operating manual
Accessories as shown in the pictures
Condition
Used
Optical condition as shown in the pictures
Inspection possible by appointment
Note: The unit has been converted to use R452A refrigerant.
Scope of supply as pictured.
Subject to changes and errors in the technical data, as well as prior sale.
Listing
Borken
18,513 km
Climatic test chamber with humidity, 600 liters
RS-SimulatorenKSS600/75-10K -75°C bis +180°C
Call
Condition: excellent (used), RS-Simulators Climate Chamber KSS 600/75-10K
Device Data
Manufacturer: RS-Simulators Prüf- und Messtechnik GmbH
Type: KSS 600/75-10K
Design: Climate test chamber / Environmental simulation chamber
Cooling: Water-cooled
Description
Used climate test chamber from RS-Simulators.
Suitable for temperature tests, climate tests, material and aging tests.
Application in industrial testing and measurement.
Technical Data
Temperature range: -75 °C to +180 °C
Temperature change: Heating/cooling approx. 10 K/min
Test chamber volume: approx. 600 liters
Dimensions
Internal (W x D x H): 840 x 840 x 840 mm
External (W x D x H): 1200 x 1600 x 1995 mm
Electrical Data
400 V / 3~ / N / PE
Current consumption: approx. 55 A
Refrigeration System
Refrigerant: R404A / R23
R404A: 6.0 kg
R23: 3.0 kg
Weight
approx. 1400 kg
Equipment
RS-Simulators control panel / operating panel
Program operation
Observation window
Temperature monitoring in the test chamber
Operating hour counter
Side feed-through
Robust industrial design
Scope of delivery
Lasdpfx Aoy H Ib Ajnuec
RS-Simulators climate chamber KSS 600/75-10K
Scope of delivery as shown in the pictures
Functional test
Refrigerant service
Leak test
Condition: Used.
Condition: See pictures.
Inspection possible by arrangement.
Loading and transport can be organized upon request.
Subject to changes and prior sale.
If you have any questions, please do not hesitate to contact us.
Listing
Borken
18,513 km
With moisture 600 liters
CTS KlimaprüfschrankC-70/600 -70°C bis +210°C
Call
Condition: excellent (used), CTS Climate Test Chamber C-70/600
Type: C-70/600
Manufacturer: CTS Klima Temperatur Systeme
Design: Air-cooled
For sale is a CTS climate test chamber for temperature and climate testing in industry, research, development, and quality assurance.
Condition / Display:
Used unit, optical condition see pictures.
Display in manual operation / stop.
Temperature actual value: 16.59 °C
Temperature setpoint: 5.00 °C
Humidity actual value: 39.7 % RH
Water supply: 11.0 l
Special feature:
Extended temperature range up to +210 °C
(many standard versions only up to +180 °C)
Technical data:
Temperature range: -70 °C to +210 °C
Humidity range: 10 % to 98 % RH
Dew point range: -10 °C to +94 °C
Temperature change rate: approx. 2.5 K/min (heating/cooling)
Test chamber volume: approx. 600 liters
Electrical data:
Connection: 400 V / 3/N / 50 Hz
Rated power: approx. 9.0 kW
Rated current: approx. 14.6 A
Protection class: IP 22
Refrigeration system:
Refrigerant: R452A / R23
Cascade refrigeration system for low temperatures down to -70 °C
Pressure data:
Operating overpressure: 25 bar
Test pressure: 27.5 bar
Test chamber: Internal dimensions: approx. 850 x 850 x 830 mm
Dimensions: approx. 1900 x 1115 x 1850 mm
Weight: approx. 800 kg (depending on equipment)
Equipment:
Observation window
Stainless steel test chamber
Digital setpoint/actual value display
Test specimen protection / temperature limiter
VE water connection
Condensate drain
Pipe penetrations
Lasdpfsy I Tdxox Anuec
RS232 interface
Digital outputs for test specimen control
Scope of supply:
CTS Climate Test Chamber C-70/600
Scope of supply as shown in the pictures
Service / Preparation:
Functional check and replacement of necessary components
Refilling with legally compliant refrigerant (if necessary)
Leak test with certificate
Documented test run
Other:
Inspection possible by arrangement
Loading can be organized
Commercial sale
(Changes and errors in the technical data are subject to change!)
We will gladly answer any further questions you may have by telephone.
Listing
Borken
18,513 km
Temperature test chamber 600 liters
WeissWT3-600/40 -42°C bis +180°C
Call
Condition: excellent (used), We are offering a Weiss temperature test chamber for sale.
Weiss Temperature Test Chamber with S!MCON / 32-controller, water-cooled
Control Unit: "Touchpanel"
All control and operation commands can be initiated by simply touching the function symbols on the "Touchpanel" control unit.
Adjustable Feet
The test chamber is equipped with adjustable feet to compensate for floor unevenness and to provide adequate ventilation for the machine section.
Cable Ports
Cable ports are installed on both the right and left sides of the test chamber. These allow measurement cables and test devices to be routed into the test space. Ports included as standard:
- R1: NW 125 mm
- L1: NW 50 mm
(The refrigerant has been converted to R-452A)
Test Chamber Volume: approx. 600 liters
Ljdpfsyguh Iox Anueac
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1090 mm, Depth: 1660 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1000 mm, Depth: 1660 mm
Internal dimensions:
Height: 950 mm, Width: 800 mm, Depth: 800 mm
Temperature Test Data:
Temperature range: -42 to +180 °C
Temporal temperature deviation at center of usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature change rate (according to IEC 60068-3-5):
- Heating: 4.0 K/min
- Cooling: 3.0 K/min
Maximum thermal compensation: 2500 W
Operating Data:
- Test chamber lighting: Halogen bulb 2 x 24V, 50W
- Rated voltage: 3/N/PE AC 400V ±10% 50Hz
- Rated current: 15 A; Rated power: 7.8 kW
- Fuse (on-site): 16 A slow-blow
- Sound pressure level: approx. 58 dB(A) (measured 1 m in front, 1 m height)
- Refrigerant: R-452A
- Weight: 620 kg
Type: WT3-600/40
Important information for your safety as a buyer!
The following steps are carried out on our offered chambers in advance:
1. Function check and replacement of necessary components
2. Refill with legally compliant refrigerant, if necessary
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical data subject to change and errors reserved!)
We are happy to answer any further questions by phone.
Listing
Wiefelstede
18,341 km
Thermostat
DanfossRT 107 17-1566 70 bis 150 °C
Call
Condition: excellent (used), Temperature controller, temperature sensor, temperature setting, temperature converter, temperature limiter, electronic temperature controller, temperature switch, thermostat
-Manufacturer: Danfoss, thermostat temperature switch, unused, original packaging
-Type: RT 107 17-1566
-Temperature range: 70 to 150 °C
Laodpfxslc Uh Es Anujc
-Quantity: 4 thermostats available
-Price: per piece
-Package dimensions: 280/130/H75 mm
-Weight: 1.2 kg/pc.
Listing
Borken
18,513 km
Temperature test chamber 270 liters
VötschVTS³ 7027-25 -72°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7027-25
Heraeus Vötsch temperature test chamber, water-cooled
Performance data:
With temperature change rate of 25 K/min
Test chamber dimensions Height 750 mm Width 580 mm Depth 615 mm
Laedjtz Rqmspfx Anusc
External dimensions Height 1775 mm Width 780 mm Depth 1895 mm
Temperature range -72°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5
Temperature homogeneity in space ± 0.5 to ± 2.0
Temperature change rate cooling 25 K/min
Temperature change rate heating 25 K/min
Heat compensation at -20 °C 8000 W
Heat compensation at +20 °C 8000 W
Test volume: 270 liters
2x lateral feed-through ∅ 125 cm
1x side feed-through ∅ 50 cm
Cabinet is water-cooled
Test room lighting:
LED strip 24 V, 6.8 W / 2x halogen bulb 24 V, 50 W
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 26 KW
Rated current: 44 A
Refrigerant: R-452A and R-23
Weight: approx. 980 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Climatic test chamber with humidity, 600 liters
CTSC-40/600 -40 bis +180°C
Call
Condition: excellent (used), CTS Climate Test Chamber Type: C -40/600, Air-Cooled
(converted to R-452a refrigerant)
Test chamber volume: 600 liters
Temperature tests:
- Temperature range: -40°C to +180°C
- Temperature deviation: ±0.1 K / ±0.3 K over time (at stabilized condition)
- Average temperature rate of change (without test load and radiant heat):
- Heating: 2.5 K/min
Ljdpow U Awmefx Anuoac
- Cooling: 3.0 K/min
- Maximum radiant heat input: 2500 W at +20°C
Climatic tests:
- Climate range / Technical data:
- Temperature range: +10°C to +95°C
- Humidity range: 10% r.h. to 98% r.h.
- Dew point range I: +7°C to +94°C
- Dew point range II: –10°C to +7°C
- Consistency values (over time):
- Humidity consistency I: ±0.5% r.h. to ±1.5% r.h.
- Humidity consistency II: ±1% r.h. to ±3% r.h.
- Temperature consistency: ±0.1 K to ±0.3 K
Chamber internal dimensions (approx.): Height: 850 mm, Width: 850 mm, Depth: 830 mm
External dimensions (approx.): Height: 1900 mm, Width: 1115 mm, Depth: 1850 mm
Refrigerant: R-452A
Power connection: 400V 3/N 50Hz
Connected load: 8.2 kW, Rated current: 11.9 A
Weight: 550 kg
Important information for your purchase!
The following checks and procedures are performed on all our offered chambers prior to delivery:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run
Condition: used
Scope of delivery: (see image)
(Subject to changes and errors in the technical data and specifications!)
If you have further questions, we will be happy to answer them by phone.
Listing
Remscheid
18,553 km
Control unit
MitsubishiHA80CB-SS Servomotor SN:180715 + OSE 5KN-6-12-108 Encoder SN:66018S
Call
Condition: ready for operation (used), Mitsubishi HA80CB-SS servo motor, serial number: 180715 + Tamagawa OSE 5KN-6-12-108 encoder, serial number: 66018S, used, with normal signs of wear, 100% functional, scope of delivery as shown in the photos.
Lajdpfx Asi D I R Djnuoc
Listing
Borken
18,513 km
Temperature test chamber 15 K/min
Weiss -70°C +180°CWT-1300/70/15 1340 Liter
Call
Condition: excellent (used), Weiss WT-1300/70/15 Temperature Testing Chamber
Manufacturer: Weiss Umwelttechnik GmbH
Type: WT-1300/70/15
Lajdpfxeza Dv Io Anuoc
Water-cooled temperature testing chamber with touch panel control for temperature tests in research, development, quality assurance, and industry.
Technical Data
Temperature range: -70 °C to +180 °C
Test chamber volume: approx. 1340 liters
Temperature change rate (heating): 15 K/min
Temperature change rate (cooling): 10 K/min
Temperature deviation (over time): ± 0.1 to ± 0.5 K
Temperature homogeneity (spatial): ± 0.5 to ± 2 K
Test chamber dimensions:
Height 920 mm
Width 1100 mm
Depth 1330 mm
External dimensions:
Height approx. 2050 mm
Width approx. 1300 mm
Depth approx. 3200 mm
Permissible test specimen load:
Test chamber floor: 150 kg
Insert shelf: 50 kg
Electrical Data
Rated voltage: 3/N/PE AC 400 V ±10 % 50 Hz
Rated current: 63 A
Rated power: 44 kW
Refrigeration System
Refrigerant R404A: 14.0 kg
Refrigerant R23: 5.4 kg
R404A LP max.: 18 bar
R404A HP max.: 25 bar
R23 LP max.: 19 bar
R23 HP max.: 25 bar
Standing pressure: 18.5 bar
Equipment
Touch panel control
Stainless steel test chamber
Multiple insertion levels
Side access port
Heated door seal
Water-cooled refrigeration unit
CEE connection
CE marking
Weight: approx. 1500 kg
Condition
Used equipment from industrial application.
Optical condition as shown in the pictures.
For the safety of our customers, the following work will be carried out on the offered climate chambers beforehand:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
Scope of delivery: see pictures
Shipping or freight transport possible.
Subject to changes, errors and prior sale.
We will be happy to answer any further questions by telephone.
Listing
Remscheid
18,553 km
Component
Axesta Grossenbacher Axis Control IEEE 488 / 50 70 086 SN:9705180044 !
Call
Condition: new, Axesta Grossenbacher Axis Control IEEE 488 / 50 70 086, serial number: 9705180044, unused, 100% functional, scope of delivery as shown in the photos.
Laedpfx Anoi D T A Aousc
Listing
Remscheid
18,553 km
Component
Axesta / Grossenbacher Axis Control IEEE 488 / 50 70 086 SN:9705180034 !
Call
Condition: new, Axesta 50 70 086 Axis Control, Serial No.: 9705180034, unused, in opened original packaging, 100% functional, scope of delivery as shown in the photos.
Lasdei D T Aqopfx Anusc
Trust Seal
Dealers certified through Machineseeker

Listing
Remscheid
18,553 km
Control unit
BoschSE-C4.170.030-10.037 Servomotor SN:861000004 !
Call
Condition: new, Bosch SE-C4.170.030-10.037 servo motor, serial number: 861000004, unused, in open original packaging, 100% functional, scope of delivery as shown in the photos.
Lasdpsi D Hfdefx Anusc
Listing
Borken
18,513 km
Climate test chamber with humidity control
Feutron3707/06 Temp. -40°C bis 150°C
Call
Condition: excellent (used), Here we offer a Feutron climate test chamber.
Feutron Climate Test Chamber
Temperature
Temperature range: -40...90°C
Climatic range (without heat load): 10...85°C
Temporal temperature deviation during temperature operation: ≤ ± 0.5 K/min
Temporal temperature deviation during climatic operation: ± 1.0... ± 1.5 K/min
Change rates
Heating: avg. 2.0 K/min
Cooling: avg. 2.0 K/min
Standard IEC 1646 is achievable with testing, solar modules up to max. 160kg weight and nonlinear ramps (setpoint jump)
Drying
Air drying: condensation drying
Humidity
Air humidification: steam humidification
Humidity range: 10...95 % r.h.
Temporal humidity deviation: ≤ ± 3.0... ±5.0 % r.h.
Dew point range: 8...80.9°C
Test Chamber
Test chamber volume: 7.0 m³
Dimensions
Internal dimensions: Width 1500 mm x Height 2250 mm x Depth 2000 mm
Swing door DIN right, heated, Width 900 mm x Height 2100 mm
Observation window, heated, with blackout shutter and lockable: Width 500 mm x Height 600 mm
Feedthrough: 2x, right front side, Ø 75 mm
Irradiation unit, test chamber
Opening: 4x in left side wall for SC 2500, each 850 x 700 mm
Irradiated area when using SC 2500: 1200 x 1200 mm
Radiation intensity at 1.0 m wall distance: 1000 ± 10% W/m²
Lighting: 1x halogen lamp, 200W
Refrigeration system: Bitzer compressor, semi-hermetic, 2-stage, air cooled
Condenser: split condenser (outdoor installation, winter control)
Refrigerant: R507 / R23
Temperature control system
Coolant medium Tyfocor / water
Mixing ratio 50/50%
Coolant density: 1.072 kg/dm³
Filling quantity: approx. 80 dm³
Pyranometer
Temperature range: -40...150°C
Max. radiation absorption: 4000 W/m²
Spectral range (50% points): 305...2800 nm
Sensitivity (nominal): 7 µV/W/m²
Power supply, test chamber
Mains connection: 400V, 3/N/PE, AC, 50Hz
Connection type: hardwired
Max. simultaneous power demand: approx. 32.0 kW
Supply fuse: 3 x 63, Char C (A)
Power supply, SolarConstant
Mains connection: 400V, 3/N/PE, AC, 50Hz
Lajdpfozd Sdgjx Anusc
Connection type:
Max. simultaneous power demand: approx. 30.0 kW
Supply fuse: 3 x 63, Char C (A)
Overall external dimensions of the test cell including: equipment room/control cabinet and control cabinet for SolarConstant 2500
External dimensions equipment room: Width 3440 mm x Height 2580 mm x Depth 2950 mm
/control cabinet: Width 2200 mm x Height 1830 mm x Depth 1100 mm
External dimensions condenser, split: Width 900 mm x Height 950 mm x Depth 2000 mm
Weight test chamber (total): approx. 2700 kg
Condenser empty weight: 153 kg
Weight: 2700 kg
Type: 3707/06
Condition: used
Scope of delivery: (see picture)
(Technical data and information are subject to change and errors!)
For further questions, we are happy to assist you by phone.
Listing
Borken
18,513 km
Temperature chamber
ThermotronSE-1000-5-5
Call
Condition: excellent (used), Thermotron Temperature Chamber
Here we offer a Thermotron temperature chamber.
Water-cooled
Thermotron temperature chamber SE-1000-5-5
Dimensions of the working area - WxDxH: 102 x 100 x 97 centimeters
Lsdpszd R S Nofx Anusac
Working area volume: 986 liters
Temperature uniformity: ± 0.5°C
Temperature range: -70ºC to 180ºC
Temperature control tolerance: 0.3°C
Installation dimensions - WxDxH: 122 x 188 x 218 centimeters
Electrical requirements 400/3/50 32.4 A
Refrigerant: R-404A / R23
Approximate weight: 862 kg
Type: Thermotron SE-1000-5-5
For your safety as a buyer, please note the following information!
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Hoofddorp
18,565 km
Closed box
IvecoDaily 70C18 Koffer 7 TON LBW 1000 Kg Euro 6
Call
Condition: excellent (used), mileage: 223,714 km, power: 132 kW (179.47 HP), first registration: 01/2020, fuel type: diesel, tire size: 225/75R16, axle configuration: 4x2, wheelbase: 4,750 mm, fuel: diesel, fuel tank capacity: 85 l, color: white, driver cabin: day cab, gearing type: automatic, number of gears: 8, emission class: euro6, suspension: air, number of seats: 2, total length: 7,670 mm, total width: 2,320 mm, total height: 3,100 mm, permissible axle load (axle 1): 2,500 kg, permissible axle load (axle 2): 5,350 kg, loading space length: 5,240 mm, loading space width: 2,240 mm, loading space height: 2,090 mm, Year of construction: 2020, Equipment: ABS, AdBlue, Bluetooth, USB port, air conditioning, airbag, central locking, cruise control, electric window regulation, electronic stability program (ESP), hill-start assist, onboard computer, power mirror, sliding door, tail-lift, traction control, General information
Number of doors: 3
Cab: single
Registration number: 77-BPF-4
Technical information
Number of cylinders: 4
Engine capacity: 2.998 cc
Transmission
Transmission: HI-MATIC, 8 gears, Automatic
Axle configuration
Tyre size: 225/75R16
Brakes: disc brakes
Front axle: Max. axle load: 2500 kg; Steering; Tyre profile left: 80%; Tyre profile right: 80%
Rear axle: Max. axle load: 5350 kg; Tyre profile left inner: 70%; Tyre profile left outer: 70%; Tyre profile right outer: 70%; Tyre profile right outer: 70%; Suspension: air suspension
Weights
Empty weight: 3.865 kg
Carrying capacity: 3.135 kg
GVW: 7.000 kg
Functional
Tail lift: DHOLLANDIA DHLM.15, tail lift, 1000 kg
Make of bodywork: LAMBOO
Maintenance
APK (MOT): New APK (MOT) upon delivery
Condition
Technical condition: very good
Visual appearance: very good
Damages: none
Additional information
Please contact Moussa or Youssef for more information
= Additional options and accessories =
- Camera 360 degree
- Climate control
- Heated door mirrors
- Lane assist
- Multifunctional Steering Wheel
- Passenger seat
- Radio/Cd/Audio system
- Reversing camera
Lasdpfey Dt I Nex Anuec
- Side door
- Tachograph
- Twin wheel axle
= Remarks =
VIDEO:
Very beautiful and neat
Iveco Daily 70C18 3.0 D 180hp Euro 6D
Hi-Matic 8-speed automatic
GVW 7000 KG ( Driving license C1 / C )
Payload 3175 kg
Internal dimensions Cargo space L. 5243 mm / W. 2236 mm / H. 2093 mm
Electric sliding door
223000 KM Fully dealer maintained
Technically and visually in very good condition
We make it easier for you to find: "thermotron se-1000-6-6 -70°c bis + 180°c"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you