Drying and Burn-in Furnace TRO, Model II
Drying and Burn-in Furnace TRO, Model II
Fixed price plus VAT
€27,345
Year of construction
2024
Condition
New
Location
Bünde 

Show images
Show map
Machine data
- Machine type:
- Drying and Burn-in Furnace TRO, Model II
- Machine number:
- 05004100140
- Year of construction:
- 2024
- Condition:
- new
Price & Location
Fixed price plus VAT
€27,345
- Location:
- Daimlerstraße 28-32, 32257 Bünde, DE
Call
Machine sale

Have you already listed your used machine?
Sell via Machineseeker without commission.
More about selling machinery
More about selling machinery
Details about the offer
- Listing ID:
- A7295457
- Reference number:
- 05004100140
- Update:
- 17.03.2025
Description
Drying and Burn-in Furnace TRO, Model III
Dwjdpfx Adsh Tytbsuec
For drying racks with max. 50rods, useable size 100x140cm, outer dimensions: approx. 2520mm wide x 1870mm deep x 2300mm high, useable space: approx. 1700x 1350x 1660cm. Suitable for vaporisation of low amounts of solvent, authorised for inks and solvents up to hazard class A II, according to safety requirements DIN EN 1539 (max. permitted solvent quantity: 110g per charge). Equipped with control of the minimum exhaust volume and a heating system in regard to the exceedance of the max. temperature. Fixing and drying temperature: up to max. 180°C. Power connection: 400V/50Hz, 21kW, weight: 1,000kg, varnishing: corps RAL 7035 (light grey), doors RAL 7037 (dust grey). Special varnishing upon request.
Chamber dryer, all-steel construction, with good thermal insulation. Simple insertion of drying racks by means of easy-to-open wing doors. The air is sucked out of the drying chamber by ventilators, is blown through thermostat-controlled heating registers and re-fed temperature-controlled to the drying chamber. The solvents released during the drying process are dissipated from the exhaust side of the ventilator while supply air gets into the drying chamber. The horizontal air guide in the drying chamber guarantees an even temperature control. The required temperature can easily be adjusted via actual and nominal value thermostat. Overheating protection by safety thermostat. Particularly suitable for fixing and drying of textile inks, flock glues as well as for burning-in of plate and aluminium signs up to 180°C. - Various drying racks for different applications available. - We recommend the installation of a gas warning unit. ATTENTION: Not permitted for solvents! Not permitted for foods!
Dwjdpfx Adsh Tytbsuec
For drying racks with max. 50rods, useable size 100x140cm, outer dimensions: approx. 2520mm wide x 1870mm deep x 2300mm high, useable space: approx. 1700x 1350x 1660cm. Suitable for vaporisation of low amounts of solvent, authorised for inks and solvents up to hazard class A II, according to safety requirements DIN EN 1539 (max. permitted solvent quantity: 110g per charge). Equipped with control of the minimum exhaust volume and a heating system in regard to the exceedance of the max. temperature. Fixing and drying temperature: up to max. 180°C. Power connection: 400V/50Hz, 21kW, weight: 1,000kg, varnishing: corps RAL 7035 (light grey), doors RAL 7037 (dust grey). Special varnishing upon request.
Chamber dryer, all-steel construction, with good thermal insulation. Simple insertion of drying racks by means of easy-to-open wing doors. The air is sucked out of the drying chamber by ventilators, is blown through thermostat-controlled heating registers and re-fed temperature-controlled to the drying chamber. The solvents released during the drying process are dissipated from the exhaust side of the ventilator while supply air gets into the drying chamber. The horizontal air guide in the drying chamber guarantees an even temperature control. The required temperature can easily be adjusted via actual and nominal value thermostat. Overheating protection by safety thermostat. Particularly suitable for fixing and drying of textile inks, flock glues as well as for burning-in of plate and aluminium signs up to 180°C. - Various drying racks for different applications available. - We recommend the installation of a gas warning unit. ATTENTION: Not permitted for solvents! Not permitted for foods!
Documents
Seller
Note: Register for free or log in, to access all information.
Send inquiry
Telephone & Fax
+49 5223 ... show
Your listing has been deleted successfully
An error has occurred