Climate chamber Temp. and humidityEspec
PHP-J3 bis +100°C
Climate chamber Temp. and humidity
Espec
PHP-J3 bis +100°C
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Climate chamber Temp. and humidity
- Manufacturer:
- Espec
- Model:
- PHP-J3 bis +100°C
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, Deutschland

Call
Details about the offer
- Listing ID:
- A16418486
- Reference number:
- 24224
- Update:
- 15.11.2024
Description
Espec
Type: PHP - J3
Technical data:
Air-cooled
Temperature and humidity range Room temperature +10°C to +100°C / 40 to 98% rel. LF
Temperature fluctuation ±0.3 K
Lredpetzbz Ajfx Adkjw
Humidity fluctuation ±2.5%
Volume 398 liters
Dimensions:
Internal dimensions: Width 600 mm x height 830 mm x depth 800 mm
External dimensions: Width 1010 mm x height 1690 mm x depth 1273 mm
Mains voltage: 400 VAC 3∅ 50 Hz
Maximum current 400 VAC 8.3 A
Weight: 335 kg
Scope of delivery: Espec climatic test chamber
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
The listing was translated automatically. Translation errors are possible.
Type: PHP - J3
Technical data:
Air-cooled
Temperature and humidity range Room temperature +10°C to +100°C / 40 to 98% rel. LF
Temperature fluctuation ±0.3 K
Lredpetzbz Ajfx Adkjw
Humidity fluctuation ±2.5%
Volume 398 liters
Dimensions:
Internal dimensions: Width 600 mm x height 830 mm x depth 800 mm
External dimensions: Width 1010 mm x height 1690 mm x depth 1273 mm
Mains voltage: 400 VAC 3∅ 50 Hz
Maximum current 400 VAC 8.3 A
Weight: 335 kg
Scope of delivery: Espec climatic test chamber
The following information is for your safety as a buyer!
The following points are carried out on our chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Borken
18,513 km
Climate chamber Temp. and humidity
EspecPHP-J3 bis +100°C
EspecPHP-J3 bis +100°C
Listing
Borken
18,513 km
Climate chamber with humidity 34 liters
WeissWKL 34/60 -60°C bis 150°C
WeissWKL 34/60 -60°C bis 150°C
Listing
Borken
18,513 km
Climate chamber
VötschVC³ 4060
VötschVC³ 4060
Listing
Borken
18,513 km
Temperature cabinet 110 liters
VötschVT 7011 -70°C bis +180°C
VötschVT 7011 -70°C bis +180°C
Listing
Borken
18,513 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Listing
Nieuw-Vennep
18,570 km
Filling machine Dosing machine Filling
50-500ml Cilinder Water Oil Creme FluidAfvulmachine Doseermachine Vulmachine
50-500ml Cilinder Water Oil Creme FluidAfvulmachine Doseermachine Vulmachine
Listing
Borken
18,513 km
Climate chamber
CTSC-40/200
CTSC-40/200
Listing
Borken
18,513 km
Corrosion test cabinet for salt spray
VLMCC 1000-FL HL V.745.672.120
VLMCC 1000-FL HL V.745.672.120
Listing
Berlin
18,139 km
All Surface Empty Bottle Inspector
KronesLinatronic 735 M2
KronesLinatronic 735 M2
Your listing has been deleted successfully
An error has occurred