Temperature test chamber ex protected
CTS T-30/950 Ex/I

Year of construction
2011
Condition
Used
Location
Borken Germany
Temperature test chamber ex protected CTS T-30/950 Ex/I
Temperature test chamber ex protected CTS T-30/950 Ex/I
Temperature test chamber ex protected CTS T-30/950 Ex/I
Temperature test chamber ex protected CTS T-30/950 Ex/I
Temperature test chamber ex protected CTS T-30/950 Ex/I
Temperature test chamber ex protected CTS T-30/950 Ex/I
Temperature test chamber ex protected CTS T-30/950 Ex/I
Temperature test chamber ex protected CTS T-30/950 Ex/I
more Images
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I
CTS T-30/950 Ex/I
Show images
Show map

Machine data

Machine type:
Temperature test chamber ex protected
Manufacturer:
CTS
Model:
T-30/950 Ex/I
Year of construction:
2011
Condition:
excellent (used)

Price & Location

Location:
Einsteinstraße 8a, 46325 Borken, DE Germany
Call

Details about the offer

Listing ID:
A7538378
Reference number:
23117
Update:
27.06.2025

Description

CTS
Type: T-30/950 Ex/I
CTS Temperature Test Chamber, Explosion-Proof
Control – 32-bit controller
LCD control panel
Digital display for set and actual values
Numerical input of set values
Error messages in plain text
RS 232 interface
Free switching channels for product-side test specimen activation
Temperature Testing:

Temperature range: -30°C to +80°C
Temperature deviation: ±0.3 K over time
Temperature change rate:
Heating: 2 K/min
Cooling: 1.5 K/min down to -10°C
Thermal radiation: approx. 1000 W at +20°C
approx. 200 W at -25°C
Dcjdpfxoihb Amj Af Ijn
Nitrogen inerting with residual oxygen monitoring
With nitrogen inerting, the test chamber is first purged with a large flow rate of N2 until the
o2 content drops below 3%. Then, it switches to a base flow amount (approx. 10% of the large flow rate).
The nitrogen flow for the base amount is measured and displayed using a flowmeter and monitored via a limit switch.
O2 monitoring continuously extracts gas from the test chamber via a flame arrestor and passes it over an O2 sensor which checks the residual oxygen content of the extracted air.
Afterwards, the gas is returned to the test chamber via a second flame arrestor.
The extraction pump is monitored by a volumetric flow meter. Additional details can be found in the Dräger user manual in the appendix.
The gas system is currently deactivated!
All technical data refer to an ambient temperature of +25°C, nominal voltage 400V, without test specimen, without irradiation, and without additional equipment.
Dimensions:
Test chamber volume: 950 liters
Test chamber dimensions: Height approx. 700 mm / Width approx. 900 mm / Depth approx. 1500 mm
External dimensions: Height approx. 2400 mm / Width approx. 1270 mm / Depth approx. 3125 mm
Operating data:
Electrical connection: 400V +6/-10 %, 3/N, 50 Hz
Nominal power: 21.6 kW
Rated current: 36.5 A
Protection class: IP 54
Condensate drain: non-pressurized, R 1/2" inner thread
Sound pressure level:

The listing was translated automatically. Translation errors are possible.

Seller

Last online: A week ago

Registered since: 2012

596 listings online

Trustseal Icon
Call

Send inquiry

Countryus 
Germany
Austria
Switzerland
United States
United Kingdom
France
Belgium
Spain
Mexico
Italy
Netherlands
Poland
Russian Federation
Belarus
Ukraine
Estonia
Turkey
New Zealand
Ireland
Czech Republic
Denmark
Finland
Sweden
Norway
Luxembourg
Greece
Lithuania
Latvia
Iceland
Portugal
Brazil
Venezuela
Argentina
Hungary
Slovakia
Romania
Moldova
Slovenia
Serbia
Montenegro
Albania
Croatia
Bulgaria
Macedonia
Bosnia and Herzegovina
Israel
Egypt
Morocco
India
Indonesia
South Korea
Japan
Thailand
Malaysia
Vietnam
China
Taiwan
Iran
Bangladesh
Afghanistan
Note: Your inquiry will be forwarded to all sellers in this machine category. This allows you to receive a large number of offers.
The inquiry could not be sent. Please try again later.

Telephone & Fax

+49 2861 ... show