Zwick Roell HIT5P Plus pendulum impact testerZwick Roell Pendelschlagwerk
HIT5P Plus inkl. TestXpert III
Zwick Roell HIT5P Plus pendulum impact tester
Zwick Roell Pendelschlagwerk
HIT5P Plus inkl. TestXpert III
Year of construction
2019
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Zwick Roell HIT5P Plus pendulum impact tester
- Manufacturer:
- Zwick Roell Pendelschlagwerk
- Year of construction:
- 2019
- Condition:
- excellent (used)
- Functionality:
- fully functional
Price & Location
- Location:
- Mollenwieske 4a, 46325 Borken, DE
Call
Details about the offer
- Listing ID:
- A19716451
- Update:
- 13.08.2025
Description
Zwick Roell Pendulum Impact Testing Machine HIT5P Plus incl. TestXpert III software and 2 Charpy pendulums
Year of Manufacture: 2019
Dossier number: DO733812
Safety guard, fixed left side
• 010924
TestXpert III Software
TestXpert III Basic Program 1035123
TestXpert III Standard Test Program 1035790
Manual
Charpy Pendulum 1J BPI-ACPECHI.112
Charpy Pendulum 5J BPI-ACPECHI.115
Performed according to Charpy ISO 179-1:2000 + Amend. 1:2005 German Version EN ISO 179-1:2000 + A1_2005
Dimensions: 680 x 658 x 404 mm (without guard)
Maximum working capacity: 5 J
Dimensions (W x H x D): 680 x 658 x 404 mm (without guard)
Weight (without fixtures) approx. 75 kg
Electrical connection: 100 to 240 V, 50/60 Hz, 70 W
Interfaces: RS232, USB
Angular resolution: 0.018°
Test results,
numerical
Impact energy [%]
Impact energy [J; ft lbf]
Dksdpfxsw H Ando Afzeu
Impact toughness [kJ/m²]
Control function: Pendulum vertical position
Oscillation duration
Pendulum vertical position
Oscillation period
Correction function: friction correction
Impact tensile test:
Air and bearing friction, kinetic yoke energy
3.1 Charpy Testing
The Charpy blocks consist of a solid cast base. Test-specific parts, such as anvils and supports, are selected according to the specimen spectrum.
The anvils, which through surface roughness and radius can significantly affect test results, are fully precision CNC-manufactured and 100% measured. Single-piece anvils, which often lack sufficient dimensional accuracy, are not offered by ZwickRoell. During installation, the spatial position of the anvils relative to the pendulum hammer is ensured by an optional gauge.
Anvils are subject to higher wear than supports, but two-piece anvils can be economically replaced independently of other accessories. Quick-change adapter plates allow adjustment of the impact point to the specimen width (impact direction). Adaptation to specimen thickness (vertical direction) is achieved by appropriately dimensioned supports, which are accurately fitted using locating pins.
Optional accessories for the testing frame include a pivoting safety shield and alignment units, which position the specimen either at the notch or at one end face aligned to the impact center.
Advantages:
• Rapid block change
• Precision manufacturing and documented 100% dimensional accuracy control of the anvils
The listing was translated automatically. Translation errors are possible.
Year of Manufacture: 2019
Dossier number: DO733812
Safety guard, fixed left side
• 010924
TestXpert III Software
TestXpert III Basic Program 1035123
TestXpert III Standard Test Program 1035790
Manual
Charpy Pendulum 1J BPI-ACPECHI.112
Charpy Pendulum 5J BPI-ACPECHI.115
Performed according to Charpy ISO 179-1:2000 + Amend. 1:2005 German Version EN ISO 179-1:2000 + A1_2005
Dimensions: 680 x 658 x 404 mm (without guard)
Maximum working capacity: 5 J
Dimensions (W x H x D): 680 x 658 x 404 mm (without guard)
Weight (without fixtures) approx. 75 kg
Electrical connection: 100 to 240 V, 50/60 Hz, 70 W
Interfaces: RS232, USB
Angular resolution: 0.018°
Test results,
numerical
Impact energy [%]
Impact energy [J; ft lbf]
Dksdpfxsw H Ando Afzeu
Impact toughness [kJ/m²]
Control function: Pendulum vertical position
Oscillation duration
Pendulum vertical position
Oscillation period
Correction function: friction correction
Impact tensile test:
Air and bearing friction, kinetic yoke energy
3.1 Charpy Testing
The Charpy blocks consist of a solid cast base. Test-specific parts, such as anvils and supports, are selected according to the specimen spectrum.
The anvils, which through surface roughness and radius can significantly affect test results, are fully precision CNC-manufactured and 100% measured. Single-piece anvils, which often lack sufficient dimensional accuracy, are not offered by ZwickRoell. During installation, the spatial position of the anvils relative to the pendulum hammer is ensured by an optional gauge.
Anvils are subject to higher wear than supports, but two-piece anvils can be economically replaced independently of other accessories. Quick-change adapter plates allow adjustment of the impact point to the specimen width (impact direction). Adaptation to specimen thickness (vertical direction) is achieved by appropriately dimensioned supports, which are accurately fitted using locating pins.
Optional accessories for the testing frame include a pivoting safety shield and alignment units, which position the specimen either at the notch or at one end face aligned to the impact center.
Advantages:
• Rapid block change
• Precision manufacturing and documented 100% dimensional accuracy control of the anvils