Climate chamber with humidity, 100 litersWeiss
WKL 100/40 -40...+180°C
Climate chamber with humidity, 100 liters
Weiss
WKL 100/40 -40...+180°C
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Climate chamber with humidity, 100 liters
- Manufacturer:
- Weiss
- Model:
- WKL 100/40 -40...+180°C
- Condition:
- excellent (used)
Price & Location
- Location:
- Einsteinstraße 8a, 46325 Borken, DE
Call
Details about the offer
- Listing ID:
- A20124430
- Reference number:
- 24814
- Update:
- 02.10.2025
Description
Type: WKL 100/40
Climate Test Chamber, Air-Cooled
with Humidity Control, -40 to +180°C
Specifications for Temperature Testing:
Temperature Range: -40 to +180°C
Temperature stability at steady state:
Temporal fluctuation in center of workspace: ±0.3 to ±1 K
Spatial deviation: ±0.5 to ±2 K
Rate of temperature change:
Heating: 3.5 K/min
Cooling: 5 K/min
Heat compensation capacity: max. 1100 W
Specifications for Climatic Testing:
Humidification System Data
Reservoir capacity: approx. 13 l
Water quality: Demineralized
pH value: 6 – 7
Conductivity: max. 20 μS/cm
Water consumption at constant temperature +40°C, 92% r.H.: 2 l / 24 h
Temperature range: +10 to +95°C
Humidity range: 10 to 98% r.H.
Temperature and humidity variation (steady state):
Temporal temperature fluctuation in center of workspace: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temporal humidity fluctuation in center of workspace: ±1 to ±3% r.H.
Mechanical Load Data:
Maximum load on chamber floor: 25 kg
Per shelf: 10 kg
Total shelf load: 50 kg
Access port: 50 mm diameter
Interfaces:
Ethernet interface (RJ45), USB interface
Operational Data:
Chamber lighting: Halogen bulb 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 3.0 kW
Rated current: 13.0 A
Required fuse: 16A slow blow
Protection class:
Control cabinet IP 22 and operator panel IP 54
Heat Emission for Air-cooled Test Chambers:
Max. heat emission to ambient: 2000 W
Noise Measurement:
Sound pressure level (free field), measured at 1 m in front and 1.6 m high: approx. 56 dB(A)
Cjdpfjxhf Erjx Abujrh
Chamber Volume: approx. 100 liters
Weight: 190 kg
Refrigerant: R404A
Important Safety Information for Buyers:
The following procedures are performed in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Changes and errors in technical data and specifications reserved!)
For further questions, we are happy to assist you by phone.
The listing was translated automatically. Translation errors are possible.
Climate Test Chamber, Air-Cooled
with Humidity Control, -40 to +180°C
Specifications for Temperature Testing:
Temperature Range: -40 to +180°C
Temperature stability at steady state:
Temporal fluctuation in center of workspace: ±0.3 to ±1 K
Spatial deviation: ±0.5 to ±2 K
Rate of temperature change:
Heating: 3.5 K/min
Cooling: 5 K/min
Heat compensation capacity: max. 1100 W
Specifications for Climatic Testing:
Humidification System Data
Reservoir capacity: approx. 13 l
Water quality: Demineralized
pH value: 6 – 7
Conductivity: max. 20 μS/cm
Water consumption at constant temperature +40°C, 92% r.H.: 2 l / 24 h
Temperature range: +10 to +95°C
Humidity range: 10 to 98% r.H.
Temperature and humidity variation (steady state):
Temporal temperature fluctuation in center of workspace: ±0.3 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±1.5 K
Temporal humidity fluctuation in center of workspace: ±1 to ±3% r.H.
Mechanical Load Data:
Maximum load on chamber floor: 25 kg
Per shelf: 10 kg
Total shelf load: 50 kg
Access port: 50 mm diameter
Interfaces:
Ethernet interface (RJ45), USB interface
Operational Data:
Chamber lighting: Halogen bulb 24V, 50W
Rated voltage: 1/N / PE AC 230 V ±10% 50 Hz
Rated power: 3.0 kW
Rated current: 13.0 A
Required fuse: 16A slow blow
Protection class:
Control cabinet IP 22 and operator panel IP 54
Heat Emission for Air-cooled Test Chambers:
Max. heat emission to ambient: 2000 W
Noise Measurement:
Sound pressure level (free field), measured at 1 m in front and 1.6 m high: approx. 56 dB(A)
Cjdpfjxhf Erjx Abujrh
Chamber Volume: approx. 100 liters
Weight: 190 kg
Refrigerant: R404A
Important Safety Information for Buyers:
The following procedures are performed in advance on our offered chambers:
1. Functional check and replacement of necessary components
2. New filling with legally compliant refrigerant if required
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (See photo)
(Changes and errors in technical data and specifications reserved!)
For further questions, we are happy to assist you by phone.
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Send inquiry
Telephone & Fax
+49 2861 ... show
Your listing has been deleted successfully
An error has occurred