Climate test chamber with seat pulsatorWeiss
SD 1400/+20 DU
Climate test chamber with seat pulsator
Weiss
SD 1400/+20 DU
ONO plus VAT
€16,640
Condition
Used
Location
Borken 

Show images
Show map
Machine data
- Machine type:
- Climate test chamber with seat pulsator
- Manufacturer:
- Weiss
- Model:
- SD 1400/+20 DU
- Condition:
- good (used)
Price & Location
ONO plus VAT
€16,640
- Location:
- Dunkerstrasse 29, 46325 Borken/Burlo, DE
Call
Machine sale

Have you already listed your used machine?
Sell via Machineseeker without commission.
More about selling machinery
More about selling machinery
Details about the offer
- Listing ID:
- A19961285
- Reference number:
- 48551
- Update:
- 09.09.2025
Description
Weiss Climatic Test Chamber with Seat Pulsator
Manufacturer: Weiss
Type: SD 1400/+20 DU
Test Chamber:
Material: Stainless steel
Dimensions
Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm
Capacity: 1440 liters
Outer casing
Material: Double-coated Zincor sheet
Dimensions
Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm
HxWxD 2000 x 2200 x 2000 mm
Paint finish: Light gray (RAL 9002)
Double-leaf door: hinged on the left and right
Equipment:
Tubing in the floor and ceiling: 2 each, NW 100 mm, for installing the pulsator tables
Tubing in the the side walls: 1 each, left and right, 100 mm
Dsdpfx Afoxbgrgjzjku
Cooling unit: Air-cooled
Control: Digital measurement and control system DMR
Basic control panel: Integrated into the main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS Windows
Performance data:
Temperature range without air conditioning: +20...+100 °C
Temperature stability without air conditioning: +0.2 ... t0.5 K (over time) depending on the range, in steady state
Temperature range with air conditioning: 20...+95 °C
Temperature stability with air conditioning: +0.2 ... +0.5 K (over time) depending on the range, in steady state
Dew point range: 20...+94 °C
Humidity range: 10...98 % RH
Humidity stability: +3 ... +5 % RH depending on the range, in steady state
Temperature change rate measured in the exhaust without a test specimen and without load
- Cooling: 0.5 K/min on average, between +100 and +20 °C
⁃ Heating: 0.5 K/min. On average, between +20 and +100 °C
The performance specifications refer to an ambient temperature of max. +25 °C and the specified nominal voltage.
For proper operation of the system, the ambient temperature must be between +10 and +35 °C.
Seat test device with steel construction for placing and attaching to the climatic test chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for changing test specimens, 12 weights of 5 kg each
• 1 base frame in mild steel welded construction for attaching to the underside of the climatic test chamber. This frame is equipped with removable panels on all sides and has two hinged doors for adjusting the eccentricity. These doors have safety switches.
• 2 eccentric discs with bearings and tachometer, 2 connecting rods, 2 ball bearings,
• 2 mounting tables, perforated, 20 mm grid, 650 x 650 mm, for attaching the test specimens, made of aluminum, thickness min. 10 mm
• 2 mounting plates, perforated, 20 mm grid, 200 x 200 mm, for attaching the buttocks simulation
• 2 stainless steel 60° load rods (The connection to the test specimen is not included in our price, but can be offered subsequently upon precise specification.)
• 2 three-phase motors, 2 belt drives with tensioning devices,
• 1 pneumatic control unit with 2 manual valves, a filter-regulator unit, and a shut-off valve. 1 electrical control cabinet with 2 SEW frequency converters, hand switches, emergency stop button, 2 on/off switches, 2 speed indicators, 2 potentiometers for speed adjustment, 2 pre-selected load changers with zero position and shutdown.
Technical specifications:
Frequency: 100-1000 strokes/minute
Load: 2 x 45 g
Stroke: 0-40 mm
Load from above: 450 N each
You can find more items - new and used - in our shop!
International shipping costs upon request!
Manufacturer: Weiss
Type: SD 1400/+20 DU
Test Chamber:
Material: Stainless steel
Dimensions
Height approx. 800 mm
Width approx. 2000 mm
Depth approx. 900 mm
Capacity: 1440 liters
Outer casing
Material: Double-coated Zincor sheet
Dimensions
Height approx. 2000 mm
Width approx. 2200 mm
Depth approx. 2000 mm
HxWxD 2000 x 2200 x 2000 mm
Paint finish: Light gray (RAL 9002)
Double-leaf door: hinged on the left and right
Equipment:
Tubing in the floor and ceiling: 2 each, NW 100 mm, for installing the pulsator tables
Tubing in the the side walls: 1 each, left and right, 100 mm
Dsdpfx Afoxbgrgjzjku
Cooling unit: Air-cooled
Control: Digital measurement and control system DMR
Basic control panel: Integrated into the main switch panel
Interface: RS 232 C, for connection to a PC
Software: Operating software for MS Windows
Performance data:
Temperature range without air conditioning: +20...+100 °C
Temperature stability without air conditioning: +0.2 ... t0.5 K (over time) depending on the range, in steady state
Temperature range with air conditioning: 20...+95 °C
Temperature stability with air conditioning: +0.2 ... +0.5 K (over time) depending on the range, in steady state
Dew point range: 20...+94 °C
Humidity range: 10...98 % RH
Humidity stability: +3 ... +5 % RH depending on the range, in steady state
Temperature change rate measured in the exhaust without a test specimen and without load
- Cooling: 0.5 K/min on average, between +100 and +20 °C
⁃ Heating: 0.5 K/min. On average, between +20 and +100 °C
The performance specifications refer to an ambient temperature of max. +25 °C and the specified nominal voltage.
For proper operation of the system, the ambient temperature must be between +10 and +35 °C.
Seat test device with steel construction for placing and attaching to the climatic test chamber, including:
• 2 pneumatic weight lifting devices (150 mm stroke) for changing test specimens, 12 weights of 5 kg each
• 1 base frame in mild steel welded construction for attaching to the underside of the climatic test chamber. This frame is equipped with removable panels on all sides and has two hinged doors for adjusting the eccentricity. These doors have safety switches.
• 2 eccentric discs with bearings and tachometer, 2 connecting rods, 2 ball bearings,
• 2 mounting tables, perforated, 20 mm grid, 650 x 650 mm, for attaching the test specimens, made of aluminum, thickness min. 10 mm
• 2 mounting plates, perforated, 20 mm grid, 200 x 200 mm, for attaching the buttocks simulation
• 2 stainless steel 60° load rods (The connection to the test specimen is not included in our price, but can be offered subsequently upon precise specification.)
• 2 three-phase motors, 2 belt drives with tensioning devices,
• 1 pneumatic control unit with 2 manual valves, a filter-regulator unit, and a shut-off valve. 1 electrical control cabinet with 2 SEW frequency converters, hand switches, emergency stop button, 2 on/off switches, 2 speed indicators, 2 potentiometers for speed adjustment, 2 pre-selected load changers with zero position and shutdown.
Technical specifications:
Frequency: 100-1000 strokes/minute
Load: 2 x 45 g
Stroke: 0-40 mm
Load from above: 450 N each
You can find more items - new and used - in our shop!
International shipping costs upon request!
Seller
Note: Register for free or log in, to access all information.
Registered since: 2008
Send inquiry
Telephone & Fax
+49 2862 ... show
Your listing has been deleted successfully
An error has occurred