Used Single Temperature Cooling Unit (Tcu)/ Chiller for sale (43,585)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Hochdorf
18,599 km
Temperature Cooling Unit (TCU)/ Chiller
SingleChill Plus Testing CHT-130
Call
Condition: new, *TECHNICAL SPECIFICATION:
Heating capacity: up to 36 kW per consumer circuit
Cooling capacity: up to 30 kW per consumer circuit at -30°C
Load circuits: 1 or 2 as standard
Temperature range: - 45°C to +130°C
Medium: water / glycol mixture
Dimensions LxWxH (without connections) :
1-circuit: 1950 x 1280 x 1725 mm
2-circuit: 2150 x 1640 x 1725 mm
Weight:
1-circuit: approx. 1300kg
2-circuit: approx. 1500kg
*HIGHLIGHTS EQUIPMENT:
-Controls: Temperature control (standard)
-Control via SPS with touch screen
-Analogue and digital interfaces
-Internal 2-circuit pump system (INFO: Ensures performance values even at low flow rates)
-Heating control via solid-state relay (SSR)
-Flow measurement in the internal circuit for flow monitoring (INFO: If the water/glycol mixture is incorrect, the system automatically warns and switches off in the next step)
-Pressure-controlled cooling water regulator (INFO: Much more accurate than temperature controls)
Chjdpfx Aisg Ezare Nsa
Stainless steel tank, corrosion-resistant components (stainless steel/non-ferrous metal) (non-ferrous metal-free optional)
All medium-carrying components and piping insulated for low-temperature application
-Water-cooled condenser (air-cooled on request).
*OPTIONS:
-flow rate control: up to 100l/min, >4 l/min +/- 5% of measured value
-Pressure control: 0.5 to 4.5 bar (control range)
-compressed air monitoring
-test piece emptying by means of compressed air
- Cooling water monitoring
-Limitation of inlet pressure
-Other special options available on request and after technical inspection
Visit our website for more details or for other performance classes.
*This unit conforms to the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Listing
Hochdorf
18,599 km
Temperature Cooling Unit (TCU)
SingleEasitemp 150/6/45 (Easi150.B)
Call
Condition: new, *Technical standard specification:
Unit type: 6/150
Heating capacity: 6 kW
Cooling capacity: 45 kW
(Performance data at 80°C flow temperature and 15°C cooling water temperature and a pressure difference between cooling water inlet and outlet of at least 2 bar)
Medium: water up to 150°C
Maximum external volume: 9 ltr at 150°C
*Functional equipment:
- Cooling and filling controlled via solenoid valve
- Automatic filling via cooling water
- Level monitoring by magnetic float switch
- Dirt filter in return flow of circulation and cooling water inflow
- Reversing circuit for leakage stop operation (usable up to system closing temp.)
- Ball valve in flow & return
- Automatic temperature-dependent system closure
- Filling time monitoring and aquatimer
- Adjustable pump overrun
- Adjustable temperature alarm
- Options: Interface cable
- Regulation and control unit SBCmini, with relay for common alarm, 230V, on rear of controller on terminal block
- Heating control SSR
- Control box IP54
Cjdjfnvwqspfx Ai Njha
- Interface 20mA TTY; pin assignment Arburg
- Cekon plug 16A
- Corrosion-resistant components (VA,MS)
- Unit mounted on castors, two of them steerable with brake
- Additional temperature fuse for safe shutdown of the heating on heating contactor
- Bypass between flow and return with reduced cross-section
*Pump:
Type: Y2051
Delivery rate (max) 27 ltr/min
Delivery pressure (max) 4.5 bar
Motor power 0.5 kW
Type of submersible pump / peripheral impeller
*Dimensions/Weights/Colours
Dimensions L/W/H: 600 mm x 240 mm x 493 mm (without connection)
Weight: approx. 43 kg
Colour: Housing: RAL 7035 light grey
Front door: RAL 5015 sky blue
*Connections:
Circulation medium socket G1/2"
cooling water socket G3/8"
*This unit conforms to the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Listing
Hochdorf
18,599 km
Temperature Cooling Unit (TCU)
SingleCompact WK3-160-9-50 (IM160F)
Call
Condition: new, *Technical standard specification:
Heating capacity: 9 kW
Cooling capacity: 50 kW
Cedpfx Asftm Hrji Nsha
medium: water up to 160°C
Max. external volume: 16 ltr at 160°C
max. Flow rate 57l/min
max. Delivery pressure 6,0 bar
Dimension L x W x H 780 x 305 x 705 mm
Weight approx. 80 kg
HIGHLIGHTS EQUIPMENT:
- Smart Controller Plus 7" touch / 4.0 capable
- Flow measurement, adjustable flow alarms
- Return temperature display
- Frequency converter for pump speed control with automatic mode for energy-optimised operation, or adjustable flow rate (in the operating range of the temperature control system)
- Electronic pressure transducer in the flow
- Interface via 9-pin D-Sub connector 20mA/TTY
- Connection for external temperature sensor PT 100 for measuring and displaying the mould temperature
- Continuous bypass of the heat exchanger with a 3-way valve to reduce deposits in the heat exchangers
- More powerful pump, hydraulic parts made of VA, magnetically coupled
- Tool emptying by suction
- Booster pump for tool filling at high temperatures
- Filling via cooling water can be switched to separate filling
- SSR for heating control
- IP54 splash water protection
Visit our website for more details or for other performance classes.
*This unit is compliant with European Directives. Other directives and standards are only complied with if stated in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Hochdorf
18,599 km
Temperature Cooling Unit (TCU)
SingleVariotherm ATT H2-200-48
Call
Condition: new, *TECHNICAL SPECIFICATION:
Heating power hot circuit: 48 kW
heating capacity cold circuit: 12 kW
cooling capacity hot circuit: 42 kW
cooling capacity cold circuit: 270 kW
medium: water up to 200°C
Max. external volume: 10 ltr at 200°C
Max. flow rate: up to 200 l/min
max. delivery pressure: up to 6,5 bar
motor power: 5,5 kW
Dimension LxWxH: 1.395 x 753 x 1.180 mm
Weight approx. 580 kg
*HIGHLIGHTS EQUIPMENT:
Csdjg Ey Ufspfx Ai Nsha
-regulation and control via SPS with touch screen
-heating via stainless steel tubular heating elements made of Incolloy
-Heating control via solid-state relay
-control box IP54 externally ventilated2
-electrical wiring on terminal blocks
-pot. free input for signal for cold/warm changeover (front door)
- Pot.-free contact for collective alarm on 3-pin plug-in connector (front door) (front door)
-temperature control unit with heating and cooling circuit, for connection of a valve station for quick changeover between hot and cold circuit
-temperature controlled feed of the return water
-level monitoring with automatic level compensation
-dirt filter in the cooling water supply and in the return of the circulation system
-Separate automatic filling with strainer
-Flow measurement in differential pressure principle in both circuits
-monitoring of the heating rod surface by temperature sensors
-System pressure control, necessary compressed air connection: 6 to 8 bar
-booster pump type DS 360 for water make-up
-corrosion-resistant components (VA, MS)
-unit mounted on rollers and ready for connection
*OPTIONS:
-System EcoTemp for intermittent operation
-connection for ext temperature sensor PT100 or type J/K
-Remote touch screen with 15 m cable
Visit our website for more details or for other performance classes.
*This device is compliant with the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Listing
Hochdorf
18,599 km
Temperature Cooling Unit (TCU)
SingleWater Advanced WP7
Call
Condition: new, *TECHNICAL SPECIFICATION:
Heating capacity: up to 54 kW
Cooling capacity: up to 300 kW
medium: water up to 200°C
Max. external volume: 43 ltr at 200°C
max. Flow rate: max. 230 l/min
max. delivery pressure: up to 8.3 bar
Motor power: up to 3 kW
Dimensions LxWxH: 1,460 x 525 x 1,200 mm
Weight approx. 330kg
Circulation medium connection: flange DN40 (DIN EN 1092-1), form B1
*HIGHLIGHTS EQUIPMENT:
-Control and regulation Smart Controller (7" touch display)
Cjdeg Ey T Eopfx Ai Njha
-Heating control via solid-state relay
-Control box IP54, externally ventilated
-Expansion tank, heater and piping stainless steel
-Heating via stainless steel tubular heating elements made of Incolloy
-Dirt trap (circulation)
-Unit ready for connection and mounted on castors, 2 of them steerable and with brake
-Cooling and filling controlled by solenoid valve
-configurable automatic filling via KW inflow or separate connection (factory-supplied via cooling water inflow)
-flow measurement by differential pressure principle
-Level monitoring by magnetic float switch
-automatic temperature-dependent system closure (not with WP7-90)
-flow monitoring by recording the flow rate
-Bypass between flow and return with reduced cross-section
-dirty filter in the cooling water inflow, filling and return of the circulation system
-Continuous bypass of the heat exchanger via 3-way motorised control valve (WP7-180/200)
-System pressure monitoring via pressure transmitter in the AD tank (WP7-150/180/200)
-Pressure booster pump for system filling (WP7-180/200, otherwise optional)
-Safety temperature limiter (STB) in the heater and flow (WP7-200)
-Pressure gauge in the supply line on the back of the unit
-heat-insulated circulation circuit (WP7-150/180/200)
Visit our website for more details or for other performance classes.
*This unit is compliant with the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Listing
Wymysłów
17,869 km
Unitek Benchmark 043008 Chiller, Cooling unit, Recirculator, 230 V
Unitek Benchmark 043008 Chiller Agregat chłodzący Recyrkulator 230 VUnitek Benchmark 043008 Chiller Agregat chłodzący Recyrkulator 230 V
Call
Condition: excellent (used), I am offering for sale a professional Unitek Benchmark laboratory chiller/recirculator.
This unit is designed for cooling and maintaining a constant temperature of liquids in laboratory systems, measuring devices, lasers, medical equipment, and other systems requiring a cooling circuit.
The housing is made of coated steel, and the tank is a durable construction resistant to the effects of cooling fluids.
Technical data:
Manufacturer: Unitek Benchmark
Stock No.: 043008
Serial No.: LJ080297F
Power supply: 230 V AC
Chodpfxezlutgo Ai Nea
Current: 3.1 A
1 phase
Frequency: 50/60 Hz
Condition:
Used.
Very good visual condition.
Sold in the exact condition as shown in the pictures.
Listing
Forst
18,625 km
Chiller unit, 737 kW cooling capacity
RhossTFAVSZ 2660
Call
Condition: used, Year of construction: 2018, functionality: unexamined, cooling capacity: 737 kW (1,002.04 HP), type of input current: three-phase, overall weight: 8,560 kg, total width: 2,260 mm, total length: 10,080 mm, total height: 2,580 mm, Liquid cooler in free-cooling mode with air-cooled condenser and axial fans
Nominal cooling capacity: 737 kW
Energy Efficiency Ratio (EER): 3.76
Power consumption: 196 kW
Voltage: 400 V / 50 Hz
Power consumption: 196 kW
Max. operating current: 486 A
Starting current: 636 A
Cedpfx Aozmtvcoi Neha
Refrigerant type: R134A (GWP=1430)
Max. gas pressure (HPS): 2,300 kPa
Max. gas pressure (LPS): 1,800 kPa
Max. H2O pressure: 1,000 kPa
Refrigerant temperature: min. -22 °C / max. +130 °C
Sound pressure level: 62 dB(A)
Sound power: 95 dB(A)
Dimensions:
Length: 10,800 mm
Width: 2,260 mm
Height: 2,580 mm
Weight: 8,600 kg
All information is without guarantee; an inspection is highly recommended. The machine is currently still energized and filled with refrigerant.
The sale is made with the exclusion of any warranty and guarantee.
If you have any technical questions or are interested, please do not hesitate to contact us.
Listing
Tatabánya
18,030 km
Temperature control unit, chiller
Industrial FrigoTW 9/95/x
Call
Condition: used, Tempering, Circulating fluid tempering, Thermolator, Used machine
Manufacturer: Industrial Frigo
Típus: TW 9/95/x
Chedpfxoyrtk So Ai Nja
Year of manufacture: 2008
Weight: 190 Kg
Overall dimensions: 1300 x 450 x 1200 mm
Max. temperature: 95 °C
Pressure: 4,35 bar
Electrical data:
400 V ; 50 Hz ; 26 A ; 10 kW
Listing
Hessisch Lichtenau
18,422 km
Cooling water recooler, cooling unit, water cooler, chiller, water recooler, cooling device
O. Hellwig
Call
Condition: used, Cooling unit, cooling water recooler, water chiller, chiller O. Hellwig
Cedspu R Ncjpfx Ai Nsha
Year of manufacture: approx. 1995
Cooling capacity: approx. 8 kW
Rated power of cooling unit: 3 kW
Refrigerant: R422D
Water tank volume: approx. 35 liters
Circulation pump flow rate: 40 liters/min
Pump output: 0.63 kW
Water connections: 1/2 inch
Power supply: 380 Volt, 50 Hz
- Temperature setting via rotary potentiometer
Space requirement (L x W x H): 1100 x 750 x 140 mm
Weight: 285 kg
Listing
Freiberg am Neckar
18,600 km
Single-circuit temperature control unit
SingleSKA-2-L
Call
Condition: used, Year of construction: 2009, machine/vehicle number: 090924, Temperature control unit manufactured by Single, used and untested. The device is intended for applications in tool temperature control, injection molding, and industrial process engineering. It operates as a single-circuit system with an SBC control system. The medium used is water*; the maximum flow temperature is 30 °C. Heating output is not specified; pump performance is 28 l/min at 3.2 bar*. Year of manufacture is 2009, and the total weight is 105 kg.
Chjdpfxoy Su Efo Ai Nsa
Listing
Freiberg am Neckar
18,600 km
Single-circuit temperature control unit
Singlesingle
Call
Condition: used, machine/vehicle number: 0926292, Year of construction: 2009, Temperature control unit manufactured by Single, used and untested. The device is intended for applications in tool temperature control, injection molding, and industrial process engineering. It operates as a single-circuit system with an SBC control system. The medium used is water*; the maximum flow temperature is 30 °C. Heating output is not specified; pump performance is 28 l/min at 3.2 bar*. Year of manufacture is 2009, and the total weight is 105 kg.
Cjdpfxsy Su D Ue Ai Noha
Listing
Hochdorf
18,599 km
Temperatre Cooling Unit (TCU)
SingleOil Advanced D2
Call
Condition: new, *TECHNICAL SPECIFICATION:
Heating capacity: up to 36 kW
Cooling capacity: up to 116 kW
medium: oil up to 350°C
Maximum external volume: 66 ltr at 350°C
max. flow rate: up to 150 l/min
max. delivery pressure: up to 8,0 bar
Motor power: 2.8 or 4 kW
Dimensions LxWxH: 1,414 x 503 x 1,350 mm
(without connections for continuous bypass)
Weight approx. 225-320 kg
Circulation medium connection: Flange DN25 PN16-40 (DIN EN 1092-1), form B1
*HIGHLIGHTS EQUIPMENT:
-Regulation and control unit Smart Controller (7" Touch-Displ)
-Heating control via solid-state relay
-Control box IP54
-Cooling controlled via solenoid valve
-Flow measurement using the differential pressure principle
-Bypass between flow and return with reduced cross-section
-Level monitoring by means of magnetic float switch
-flow monitoring by recording the heating rod surface temperature and the flow rate
-dirt filter in the cooling water supply and in the return of the circulation system
-monitoring of the flow temperature by electronic safety temperature limiter
-external oil filler neck
Chjdpfx Aijg Ey Rfs Nsa
-Dilo fittings on internal piping connections (except pump connections)
-at 350°C: continuous bypass, including bellows valves
-Connection for nitrogen blanketing with pressure gauge and safety valve 0.5 bar at 350°C (option)
Visit our website for more details or for other performance classes.
*Unit is compliant with European Directives. Other directives and standards are only complied with if stated in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be stated in quotations or order confirmations.
Listing
Hochdorf
18,599 km
Temperatre Cooling Unit (TCU)
SingleEasitemp 95/6/45 (Easi95.A)
Call
Condition: new, *Technical Specification:
device type: 6/95
heating capacity: 6 kW
cooling capacity: 45 kW
Medium: water up to 95°C
maximum external volume: 50 ltr at 95°C
*Equipment hydraulic:
- Cooling and filling controlled by solenoid valve
- Automatic from cooling water or manual filling (at filling nozzle/option)
- Level monitoring by magnet float-switch
- Dirt trap in from process line of circulating system and cooling water inlet
- Pump reversing for leak-stop operation
- Manual mould draining via leak-stop operation and venting by tap at backside of unit
- Filling time monitoring and aquatimer
- Cool down mode (temperature adjustable)
- Adjustable temperature alarm
- Options: filling nozzle, interface cable, mechanical flow metering
*Equipment electrical:
- Controller SBCmini, with relay for collective alarm
230V switchable, on the back of controller on terminal
- Heating control by SSR
- Control cabinet IP54
- Interface 20mA TTY; pinning Arburg
- Cekon plug 16A
*General equipment:
- Corrosion resistant components (stainless stell, brass)
- Heating rod made of Incoloy
- Unit mounted on rolls, two pieces steerable with break
- Additional temperature fuse for safe heating switch-off
by contactor
*Cooling:
Power: 45 kW (stainless steel plate heat exchanger)
Cooling water connection: Socket G3/8" IG
(Performance data at 80°C flow and 15°C cooling water temperature and a pressure difference between cooling water inlet and outlet of 3 bar)
*Pump:
Type: T401
Output rate (max): 40 ltr/min
Pressure (max): 3,8 bar
Motor capacity: 0,5 kW
Construction: submersible pump / peripheral wheel
*Dimensions/Weights/Colours
Dimensions L/W/H: 514 mm x 238 mm x 493 mm (w/o conne.)
Weight: approx. 30 kg
Colour: Case: RAL 7035 light grey
Front door: RAL 5015 sky blue
Cjdpfxsfnvvis Ai Noha
*Connections:
Circulating medium int. thread G1/2"
Cooling water int. thread G3/8"
Filling (option)
*This unit complies to the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment; customer requests deviating from the standard will be indicated in offers or order confirmations.
Listing
Hochdorf
18,599 km
Temperature Control Unit/ Chiller
Single Temperiertechnik GmbHChill Advanced C-25-L
Call
Condition: new, *Technical specification:
-air-cooled, 25.5 kW referred to +10°C flow temperature at an ambient temperature of +32°C.
-temperature range flow: +5°C to +30°C
(optionally lower temperatures down to -5°C possible)
-air flow rate: 8,000 m³/h
-max. air inlet temperature: +30°C
-Optionally with heating capacity up to 24kW
*Pumps:
-Delivery capacity up to 150 ltr/ min.
-Delivery pressure up to max. 4 or 7 bar
-Motor output 1.1 or 2.2 kW
*Dimensions:
-L/W/H: 1,450 mm x 750 mm x 1,680 mm
-empty weight: approx. 480 kg
-Circulation medium connection: DN 32 IG
*Details & Highlights:
-Internal refrigerant: R 123 a
-Power supply: 380-425V/ 50Hz
-Regulation and control unit SBC-T
-Setpoint and actual value display, alarm display
-Fully hermetic reciprocating compressor
-Refrigerant receiver with safety valve according to DIN EN 378
-capacity control
-frost protection monitoring
-Flow monitoring
-grid cover over condenser
Chodpfxsg Ewwrs Ai Nea
-oil sump heater
-drainage device
-Level monitoring by magnetic float switch
-installed dirt trap in the return line in the circulating medium
-overflow valve between flow and return as pump protection, fixed setting
-high and low pressure limiter according to DIN EN 378
-stainless steel tank, capacity: 80 litres, open system completely insulated
Self-supporting housing with castors, mobile
-system for indoor installation
-control box IP 54
Other performance classes are available on request. Visit our homepage for further details.
*This unit conforms to the European Directives. Other directives and standards are only fulfilled if they are listed in the order confirmation. This technical specification reflects the standard equipment, customer requests deviating from the standard will be shown in quotations or order confirmations.
Listing
Hessisch Lichtenau
18,422 km
Cooling unit, water recirculation chiller, cooling machine, refrigeration unit, for spot welding mac
DALEXDRF 2
Call
Condition: used, Cooling unit, water-cooled condenser, DALEX Type DRF 2
Cedpeg D H Rusfx Ai Neha
Machine No. 38913719, Year of manufacture 1989
Flow rate 0.35 m3/h
Cooling capacity 1950 Watts
Operating pressure 2 to 3 bar
Refrigerant R 134a; unit was converted from R12 to R134a
Operating overpressure 18 bar
Pipe connection thread 3/4"
Tank volume 600 x 400 x 350 mm = approx. 80 liters
Mains connection 380 Volts, 50 Hz
Space requirement L x W x H 900 x 800 x 1020 mm
Weight 100 kg
Good condition
Listing
Wald
18,661 km
Temperature control unit single-circuit temperature control unit
WITTMANNMTC Basic-C90 F27
Call
Condition: ready for operation (used), Wittmann MTC Basic-C90 F27 Temperature Control Unit Single-Circuit Temperature Controller
Codoyw Rh Hjpfx Ai Njha
Price is for one unit. Several units available!
Year of manufacture: 2017
Year of manufacture: 2017
Year of manufacture: 2018
Max. temperature: 90°C
Pump capacity: 40 l/min
Dimensions: approx. 235mm x 590mm x 660mm (W x D x H)
Weight: approx. 31 kg
Power: 10 kW
You are welcome to schedule a viewing appointment.
We can also organize affordable shipping for you!
You will receive a proper invoice.
For international customers, a net invoice can also be issued, provided a valid VAT ID number is supplied.
Subject to prior sale.
Visit our shop and check our further offers.
Company names and trademarks mentioned are the property of their respective owners and are used for identification and product description purposes only.
Deviations in technical data and errors in the item description may occur and are subject to change.
Listing
Wald
18,661 km
Temperature control unit single-circuit temperature control unit
WITTMANNMTC Primus-C90 F27
Call
Year of construction: 2017, condition: ready for operation (used), Wittmann MTC Primus-C90 F27 Temperature Control Unit Single-Circuit Temperature Control Unit
Price is for one unit.
Year of manufacture: 2017
Max. temperature: 90°C
Pump capacity: 40 l/min
Dimensions: approx. 235mm x 590mm x 660mm (W x D x H)
Weight: approx. 31 kg
Power: 10 kW
You are welcome to arrange an inspection.
We are happy to organize an affordable shipping service for you!
You will receive a proper invoice.
For international customers, a net invoice can also be issued, provided a valid VAT ID number is supplied.
Subject to prior sale.
Chedpfsyw Rfxjx Ai Nsa
Visit our shop and check out our other offers.
The company names and trademarks mentioned are property of their respective owners and are used for identification and description purposes only.
Technical data may differ and errors in the article description are possible and reserved.
Listing
Hessisch Lichtenau
18,422 km
Universal temperature control unit with electric heating and connections for external cooling, circu
WEINREICHWTD 4
Call
Condition: used, Universal temperature control unit WEINREICH, Type WTD 4
Temperature control unit with electric heating and connections for external cooling
Manufacturer's serial number: 11932217, Year of manufacture: 1993
Temperature: max. 140°C
Operating overpressure: max. 6 bar
Pump capacity: 30 l/min
Tank volume: 4 liters
Heating capacity: 4 kW
Cooling capacity (heat exchanger): 15 kW
Pump motor power: 0.37 kW
Circulating water, supply + return: G 3/8"
Cooling water, supply + return: G 3/8"
Total power: 4.4 kW
Chedpfxeg Rhx Us Ai Nsa
Mains connection: 380 volts, 50 Hz, CEE plug
- Temperature control medium: water
- Temperature control with actual and setpoint display: STÖRK-TRONIC, Type ST 96-35.02K
- Water circulation pump: SPECK
- An external cooling unit is required for cooling
(the cooled water is fed to the temperature control unit)
- Movable on 4 rollers
Dimensions L x W x H: 620 x 260 x 670 mm
Weight: 55 kg
Good condition
Listing
Oradea
17,779 km
Precision Temperature Control Unit (TCU)
BOFA
Call
Year of construction: 2016, condition: defective spare-parts repository (used), machine/vehicle number: 00050, Precision Temperature Control Unit (TCU) - BOFA
THE DISPLAY CONTROLLER IS DEFECTIVE!
Year of manufacture: November 2016, serial number 00050, excellent condition, the filter is in good shape, electric documentation of the TCU is present, refrigerant gas: R134a 0.75Kg in the system
Precision temperature control unit designed for solder paste applications
Reverse flow air technology enhances filter performance and increases life
Process monitoring via temperature sensors that can be strategically mounted within the printer
Precision temperature control unit designed for solder paste applications.
The Temperature control unit (TCU) has been designed to meet a very specific process requirement within the electronics sector. The reliable placement of surface mount devices during PCB assembly requires that during the initial printing stage the solder paste is maintained at a temperature that ensures optimum performance.
With assembly now on a global basis, the variation of local climate and factory conditions means that this optimum level cannot be maintained without some form of intervention.
The design of the TCU includes cooling and heating elements which ensure that the temperature within the printing environment is maintained within 1ºC of the optimum paste performance temperature regardless of whether the factory ambient is above or below this level.
Reverse flow air (RFA) technology
The RFA technology feature causes a fall in velocity and air direction change. Larger particulate falls out of the airstream into the filter’s drop-out chamber. With less particulate entering the filter media the filter life is significantly increased, enhancing filter capture performance and ensuring longer life.
Technical specifications
1. Chiller module
2. Condensate collection container
3. Air outlet
4. Air inlet
5. Castors
6. Service door lock
7. Fail style condensate sensor
8. Four colour beacon mounting plate
Technical data:
Air delivery system: Re-circulating
Temperature range: +/- 8°C from ambient within a programmable range of 19 – 30°C
Temperature control: +/- 1°C
Cooling capacity: 2000W
Temperature sensor: Shared output from integrated printer sensor (0 – 10V input over 0 –50°C)
Air in filter: G4 (91% Average Arrestance) EN 779: 2002
Refrigerant gas: R134a 0.75Kg
Full load current: 12.6A
Start up Current: 20A
Frequency: 50 / 60Hz
Voltage: 230V +/- 10% (207V – 253V working range) Single Phase
Noise Level: higher then 75dBA*
Dimensions: 1285mm (H) + (beacon 450mm), 540mm (W), 670mm (D)
Condensate: Collected in 5 litre container for disposal or piped to drain
Weight: 140Kg
Documentation include: Electrical Schematic
Chedpfxshgr Ihe Ai Nja
Sales price: 1.500 Euro + VAT, negotiable, FCA Oradea, Romania
Irrtum, Anderungen und Zwischenverkauf vorbehalten /
Subject to errors, changes and prior sale /
Ne rezervăm dreptul la greșeli, modificări și vânzare prealabila.
We speak English. /Wir sprechen Deutsch./ Beszélünk magyarul. /Nous parlons français/Vorbim romana
Listing
Oradea
17,781 km
Precision Temperature Control Unit (TCU)
BOFA
Call
Year of construction: 2016, condition: as good as new (ex-display), machine/vehicle number: 00069, Precision Temperature Control Unit (TCU) - BOFA
Year of manufacture: November 2016, serial number 00069, excellent condition, the filter is in good shape, electric documentation of the TCU is present, refrigerant gas: R134a 0.75Kg in the system
Precision temperature control unit designed for solder paste applications
Reverse flow air technology enhances filter performance and increases life
Process monitoring via temperature sensors that can be strategically mounted within the printer
Precision temperature control unit designed for solder paste applications.
The Temperature control unit (TCU) has been designed to meet a very specific process requirement within the electronics sector. The reliable placement of surface mount devices during PCB assembly requires that during the initial printing stage the solder paste is maintained at a temperature that ensures optimum performance.
With assembly now on a global basis, the variation of local climate and factory conditions means that this optimum level cannot be maintained without some form of intervention.
The design of the TCU includes cooling and heating elements which ensure that the temperature within the printing environment is maintained within 1ºC of the optimum paste performance temperature regardless of whether the factory ambient is above or below this level.
Reverse flow air (RFA) technology
The RFA technology feature causes a fall in velocity and air direction change. Larger particulate falls out of the airstream into the filter’s drop-out chamber. With less particulate entering the filter media the filter life is significantly increased, enhancing filter capture performance and ensuring longer life.
Technical specifications
1. Chiller module
2. Condensate collection container
3. Air outlet
4. Air inlet
5. Castors
6. Service door lock
7. Fail style condensate sensor
8. Four colour beacon mounting plate
Technical data:
Air delivery system: Re-circulating
Temperature range: +/- 8°C from ambient within a programmable range of 19 – 30°C
Temperature control: +/- 1°C
Cooling capacity: 2000W
Temperature sensor: Shared output from integrated printer sensor (0 – 10V input over 0 –50°C)
Air in filter: G4 (91% Average Arrestance) EN 779: 2002
Refrigerant gas: R134a 0.75Kg
Full load current: 12.6A
Csdpfx Aijhgfnbe Nsha
Start up Current: 20A
Frequency: 50 / 60Hz
Voltage: 230V +/- 10% (207V – 253V working range) Single Phase
Noise Level: higher then 75dBA*
Dimensions: 1285mm (H) + (beacon 450mm), 540mm (W), 670mm (D)
Condensate: Collected in 5 litre container for disposal or piped to drain
Weight: 140Kg
Documentation include: Electrical Schematic
Sales price: 1.900 Euro + VAT, negotiable, FCA Oradea, Romania
Irrtum, Anderungen und Zwischenverkauf vorbehalten /
Subject to errors, changes and prior sale /
Ne rezervăm dreptul la greșeli, modificări și vânzare prealabila.
We speak English. /Wir sprechen Deutsch./ Beszélünk magyarul. /Nous parlons français/Vorbim romana
Listing
Oradea
17,781 km
Precision Temperature Control Unit (TCU)
BOFA
Call
Year of construction: 2013, condition: excellent (used), machine/vehicle number: 2310-028, Precision Temperature Control Unit (TCU) - BOFA
Chjdpjhgg Rrefx Ai Noa
Year of manufacture: November 2013, serial number 2310-028, excellent condition, the filter is in good shape, electric documentation of the TCU is present, refrigerant gas: R134a 0.75Kg in the system
Precision temperature control unit designed for solder paste applications
Reverse flow air technology enhances filter performance and increases life
Process monitoring via temperature sensors that can be strategically mounted within the printer
Precision temperature control unit designed for solder paste applications.
The Temperature control unit (TCU) has been designed to meet a very specific process requirement within the electronics sector. The reliable placement of surface mount devices during PCB assembly requires that during the initial printing stage the solder paste is maintained at a temperature that ensures optimum performance.
With assembly now on a global basis, the variation of local climate and factory conditions means that this optimum level cannot be maintained without some form of intervention.
The design of the TCU includes cooling and heating elements which ensure that the temperature within the printing environment is maintained within 1ºC of the optimum paste performance temperature regardless of whether the factory ambient is above or below this level.
Reverse flow air (RFA) technology
The RFA technology feature causes a fall in velocity and air direction change. Larger particulate falls out of the airstream into the filter’s drop-out chamber. With less particulate entering the filter media the filter life is significantly increased, enhancing filter capture performance and ensuring longer life.
Technical specifications
1. Chiller module
2. Condensate collection container
3. Air outlet
4. Air inlet
5. Castors
6. Service door lock
7. Fail style condensate sensor
8. Four colour beacon mounting plate
Technical data:
Air delivery system: Re-circulating
Temperature range: +/- 8°C from ambient within a programmable range of 19 – 30°C
Temperature control: +/- 1°C
Cooling capacity: 2000W
Temperature sensor: Shared output from integrated printer sensor (0 – 10V input over 0 –50°C)
Air in filter: G4 (91% Average Arrestance) EN 779: 2002
Refrigerant gas: R134a 0.75Kg
Full load current: 12.6A
Start up Current: 20A
Frequency: 50 / 60Hz
Voltage: 230V +/- 10% (207V – 253V working range) Single Phase
Noise Level: higher then 75dBA*
Dimensions: 1285mm (H) + (beacon 450mm), 540mm (W), 670mm (D)
Condensate: Collected in 5 litre container for disposal or piped to drain
Weight: 140Kg
Documentation include: Electrical Schematic
Sales price: 1900 Euro + VAT, negotiable, FCA Oradea, Romania
Irrtum, Anderungen und Zwischenverkauf vorbehalten /
Subject to errors, changes and prior sale /
Ne rezervăm dreptul la greșeli, modificări și vânzare prealabila.
We speak English. /Wir sprechen Deutsch./ Beszélünk magyarul. /Nous parlons français/Vorbim romana
Trust Seal
Dealers certified through Machineseeker

Listing
Nettetal
18,588 km
Chiller, water chiller unit, cooler,
MTA S.p.A., KühlmaschinenTAEevo Tech 031 P5-NF – 8,98 kW
Call
Condition: used, Year of construction: 2019, functionality: fully functional, machine/vehicle number: TET031P5-NF - 2200346063, cooling capacity: 8.98 kW (12.21 HP), type of input current: three-phase, type of cooling: water, overall weight: 331 kg, ambient temperature (max.): 46 °C, ambient temperature (min.): -5 °C, input voltage: 400 V, pressure: 6 bar, temperature: 7 °C, volume flow: 1.5 m³/h, pump pressure: 5 bar, total width: 660 mm, total length: 1,315 mm, total height: 1,373 mm, warranty duration: 3 months, input frequency: 50 Hz, Equipment: type plate available, Process air cooler / chiller / chilled water unit, air-cooled,
Type: TAEevo Tech 031 P5-NF
MTA S.p.A.
TAEevo Tech 031 P5-NF are air-cooled compact chilled water units suitable for outdoor installation (-5°C to +46°C). Includes crankcase heater, phase monitoring, 115-liter buffer tank, integrated P5 high-pressure pump, open expansion tank (14 liters), and evaporator in a NON-FERROUS design.
Chilled water outlet temperatures from -10°C to +30°C are adjustable.
Cooling capacity kW 8.98
Chilled water temperature outlet/inlet (°C): 7 / 12
Volume flow (m³/h): 1.5
Available pump pressure (bar): 5
Ambient temperature (°C): 32
Refrigerant: R 410A
Electrical data:
Voltage V: 400, Frequency Hz: 50, Phases: 3,
Max. power consumption (kW): 6.6
Max. current (A): 12
Starting current (A): 47
Csdpfsw S Ef Ijx Ai Neha
Protection class: IP54
Dimensions:
Length (mm): 1315, Width (mm): 660, Height (mm): 1373,
Weight (kg): 331
Connection: Rp 1"
Serial number: 2200346063
Year of manufacture: 2019
Condition: Visually 2-3, Technically okay
Used
Price: upon request in Euro (plus VAT, ex works Nettetal) – 3 months warranty
Used machines may have optical defects due to their use.
(Subject to technical changes and prior sale!)
Location: MTA Deutschland GmbH, 41334 Nettetal
Listing
Tatabánya
18,030 km
Coolant unit,Liquid chiller,Oil chiller
NeslabCFT300
Call
Condition: ready for operation (used), Liquid chiller, Oil chiller, Neslab, used machine
Manufacturer : Neslab
Type : CFT300
Overall dimensions : 640 x 900 x 1090 mm
Electrical data : 400 V, 50 Hz, 10 A
Chodpfsyvfrcex Ai Nsa
Refrigerant : R22
Cooling capacity : 10.6 kW
Adjustable temperature range : 5–35 °C
Water flow rate : 75.7 l/min
Listing
Lindau
18,646 km
Chiller, water chiller unit, cooler,
NOVATECH, Kühlmaschinen,NOVATECH NTC 20 – 21 kW
Call
Condition: used, Year of construction: 2020, functionality: fully functional, machine/vehicle number: NTC20 - 14720, cooling capacity: 21 kW (28.55 HP), type of input current: three-phase, type of cooling: water, overall weight: 225 kg, input voltage: 400 V, total width: 950 mm, total length: 1,080 mm, total height: 1,400 mm, warranty duration: 3 months, input frequency: 50 Hz, Equipment: type plate available, Air-cooled chiller / water chiller,
Type: NOVATECH NTC 20
NOVATECH
NOVATECH NTC 20 are air-cooled compact water chillers suitable for indoor/outdoor installation (IP 54). Includes a shell-and-tube evaporator, 110-liter buffer tank, and built-in circulation pump.
Galvanized steel frame, hot-painted with polyester powder.
Special features:
- Mounted expansion tank for internal water only
- Shut-off valve between water inlet and outlet
- Water outlet balancing valve
Cooling capacity: 21 kW
Cold water temp. Outlet/Inlet (°C): 15 / 20
Flow rate (l/min) max. 100
Available pump pressure (bar) max. 3.3
Ambient temperature (°C) 35
Refrigerant: R 410A
Chsdpswcflwefx Ai Nea
Electrical data:
Voltage: 400 V, Frequency: 50 Hz, Phases: 3
Max. power consumption (kW) 8.85
Max. current (A) 12.5
Starting current (A) 19
Protection class: IP54
Dimensions:
Length (mm) 1080, Width (mm) 950, Height (mm) 1400
Weight (kg) 225
Connection: Rp 1"
Serial no.: 14720
Year of manufacture: 2020
Condition: Visually 1-2, Technically OK
Used, like new
Price: Available upon request in euros (plus VAT from Nettetal) – 3-month warranty
Used machines may have cosmetic defects due to use.
(Subject to technical changes and prior sale!)
Location: MTA Deutschland GmbH, 88131 Lindau
Listing
Łęczna
17,609 km
Chiller
Used Industrial ChillerEF COOLING - 88 kW | With warranty
Call
Condition: excellent (used), Year of construction: 2019, functionality: fully functional, cooling capacity: 88 kW (119.65 HP), type of input current: three-phase, type of cooling: water, overall weight: 1,700 kg, input voltage: 400 V, total width: 1,300 mm, total length: 2,000 mm, total height: 2,000 mm, warranty duration: 6 months, Watercooled chiller EF COOLING EVO 90 WKL770FC 88 kW
Cooling capacity: 88 kW / 25.02 tons (12/7 — 35°C)
Year of manufacture: 2019
Chjdewlnwujpfx Ai Nja
Options: Hydraulic module. Freecooling (Dry cooler is additionally required)
Refrigerant circuit: 2 pcs.
Heat exchanger: Plate
Compressors: 4 pcs. Copeland ZR125KCE-TFD-455 (scroll)
Type of refrigerant: R407c
Hydraulic module: 2 pcs. Grundfoss CM 10-5 + 1 pcs. Grundfoss CR20-2 + 1 pcs. Grundfoss CM15-1, expansion vessel, buffer tank 500 l.
Dimensions: 2x1.3x2 m.
Weight: 1700 kg.
Working hours: 10432/10428/1333/1532 h.
Condition: Used, tested, fully operational
CONDITION, TESTING & READINESS
The chiller / kaltwassersatz / undergoes seven stages of technical inspection and operational parameter verification. It is also tested at our own test station, with connection to water (or glycol) and adjustment of parameters according to your requirements.
After testing, you will receive a detailed report with the operating performance and the overall condition of the chiller.
The chiller / kaltwassersatz / is ready for transport and commissioning.
Our engineers will assist you with cooling capacity calculations, selection of the appropriate cooling scheme, and configuration of the required equipment options.
WARRANTY & SUPPORT
The quality of the equipment is confirmed with a warranty ranging from 6 to 36 months.
Our company can also offer:
- refrigerant charging;
- replacement of oil and filters;
- technical support.
LOGISTICS
- Worldwide delivery available
- Support with loading, export documentation, and logistics coordination
Get a detailed consultation. Photos, videos, and a full testing report can be provided immediately upon request.
We make it easier for you to find: "single temperature cooling unit (tcu)/ chiller"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month






















































































































































































