Used Vötsch/Weiss Gtts 220 for sale (5,164)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
18,513 km
Dryer for coating materials
VötschLTU 60/60
Call
Condition: excellent (used), Vötsch
Type: LTU 60/60
Heraeus Vötsch dryer for coating materials
Maximum concentration of flammable substances of 40 % of the lower explosion limit (LEL)
Highest temperature of the heating surface above 750 °C
Device description:
Technical data:
Interior (usable space) 0.216 m3
Internal dimensions: Width 600 mm Height 600 mm Depth 600 mm
External dimensions: Total width 796 mm Height 1725 mm Depth 850 mm
Loading / load capacity
Total roller conveyor 55 kg
Loading height above installation floor 820 mm
Weight (net) kg 275
Ppodpfeun Rr Rsx Ak Der
Minimum exhaust air volume flow 96 m3/h
Purge time 5-fold air change 90 sec.
Increased recirculation air volume flow 33 m3/h
Total vapor space 0.414 m3
Sound pressure level (according to DIN 45635) < 70 dB(A)
Switch-off temperature
Temperature limiter (TB) fixed setting 300 °C
Temperature selector limiter (TWB) adjustable above nominal temperature 20
Temperature safety class (according to EN 60519-2)
Temperature limiter (TB) 1
Temperature selector limiter (TWB) 2
Nominal temperature 200 °C
Electrical data
Rated voltage / frequency 400V, 3/(N)PE, AC 50/60 Hz
Rated current 12.0 A
Nominal power 6.0 kW
Connected load 7.0 kW
Weight: 275kg
Condition: second-hand / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Ppjdpfxsun Rulo Ak Dor
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Climatic chamber
VötschVCS 7033
Call
Condition: excellent (used), Heraeus Vötsch climatic chamber
Here we offer you a Heraeus Vötsch climatic chamber.
Vötsch climatic chamber VCS 7033 water cooled
Temperature range: -70°C to +180°C
Temperature change rate:
Heating 7.5 K/min.
Cooling 6,5 K/min.
Humidity range: 10% to 98% r.H.
Temperature deviation temporal ± 0.5 K
Temperature deviation time-related ± 1.5 K
Test chamber dimensions: Width 675 mm x Depth 650 mm x Height 760 mm
Housing dimensions: Width 930 mm x depth 1565 mm x height 1840 mm
Lateral feedthrough 90mm ∅
approx. 330 L Weight: 600 kg
voltage: 3/N/PE AC 400V ±6/-10% 50Hz
rated power 9,5 kW
Rated current 17 A
Refrigerant R404A / R23
Type: VCS 7033
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Ppodpfx Akepz H Hxe Djr
Further questions we can answer on the phone for you.

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
18,513 km
Emission test chamber
WEISSWT 5,1'/ + 18-45
Call
Condition: excellent (used), Weiss
Here we offer a Weiss emission test chamber.
Mini - SHED for Diurnal Loss Measurements
Test chamber dimensions: Width 1600 mm x Depth 2140 mm x Height 2150 (Usable 1600) mm.
Housing dimensions: Width 1760 mm x depth 3100 mm x heights 2790 mm
Max. floor load 250 kg
Operating range +18 °C ...+45 °C, (at higher temperatures SHED operation is only possible without Tedlar bag)
Temperature range +18 °C ...+45 °C
Temperature constancy ≤ ±1 K (temporal)
Temperature change rate, (heating and cooling) approx. 0.5 K/min., without test material
Duct connection (air inlet and outlet) ∅ 80 mm, in chamber rear wall
Ppsdpomfny Iefx Ak Dsr
Shut-off valve, gas-tight (air inlet and outlet) ∅ 80 mm, gas-tight, pneumatic operation Delivery limit: connection flange of shut-off valve
Cooling water consumption approx. 0.8 m3/h
Voltage: 230/400 V; 3 PH + N + PE; 50 Hz
Rated power: 4,1 kW Rated current: 14,0A
Weight: approx. 2500 kg
type: WT 5,1'/ + 18-45
Condition: used / used
Sale ex location
Scope of supply: (Only the Weiss emission test chamber WT 5,1'/ + 18-45 Mini-SHED)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Temperature test chamber
WEISSWT1-600/70
Call
Condition: excellent (used), Weiss temperature test chamber
Here we offer a Weiss temperature test chamber.
Weiss temperature test chamber water cooled
Technical data:
Test chamber designation: WT1-600/70
Outer dimensions without hinges and door lock
height 1980 mm, width 1085 mm, depth 1655 mm
Internal dimensions
height 950mm, width 800mm, depth 800mm
Test chamber capacity: approx. 600 liters
cold / heat operation -70 to 180°C
Temperature change per time
cooling approx. 2,5 K/min
Heating up approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Permissible test material weight
Total load of grate supports 80kg
Refrigerant: R 404A +R23
Weight: 600kg
Type: WT1-600/70
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
Ppedsirmg Aepfx Ak Djr
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Assemblies / Test cabinet
VötschVT 3050 -30°C / +100°C 500 Liter
Call
Condition: excellent (used), Vötsch
Type: VT 3050
Modules / Test Chamber Temperature Chamber
Air-cooled
Test chamber capacity 500 litres
Temperature range -30°C / +100°C
Temporal temperature fluctuation K ±0.5
Spatial temperature fluctuation K ±1.5
Temperature gradient K 3
Change rate
Heating K/min 2.0
Cooling K/min 1.4
Heat compensation max. W 650
Ppedpfx Aow S E N Tek Der
Calibration values +23°C +80°C
Test chamber dimensions Width 710 mm Depth 590 mm Height 1250 mm
External dimensions Width 940 mm Depth 1030 mm Height 1955 mm
Sound pressure level db(A)
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS³ 7018-5
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7018-5
Water-cooled
Test chamber dimensions: Width 580 mm x depth 450 mm x height 750 mm
Pjdpfx Aon E Sk Esk Djpr
Housing dimensions: Width 900 mm x depth 1550 mm x height 1850 mm
Temperature test:
Temperature range: -70°C to +180°C
Temperature change rate: Heating 7.5 K/min
Temperature change rate: cooling 7.5 K/min
Test chamber volume: 190 liters
Nominal voltage: 400V
Rated current: 20 A
Rated power: 9 kW
Weight: approx. 540 kg
Refrigerant: R404A and R23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Spray and splash water test cabinet
WeissSWT 200/400
Call
Condition: excellent (used), Weiss
Ppedpfx Ajvzz A Rek Dsr
Type: SWT 200/400
Weiss spray and splash water test cabinet
The penetration of water into the housing is tested.
In conjunction with a timer, the test cycle can be automated with an adjustable test time of 3 seconds to 30 hours.
According to DIN VDE 0470 T1 or EN 60529 for tests according to protection classes IPX3 and IPX4.
The integrated circulation device means that water consumption can be reduced to a minimum.
Features
Glass door with wiper
Pneumatic drive of the swivel tube
Adjustable swivel angle
Replaceable swivel tubes
Nozzle holder swivels and can be replaced
Adjustable water volume flow and measurement
Control of the test duration
Data for mechanical stress
Max. load with test material (evenly distributed over the surface)
Permissible test material weight for test material carrier (total) 25 kg
Spray radius 200 mm / 400 mm
Data for IP protection class tests
Swivel speed approx. 60°/s
Swivel angle IPX3 approx. ± 60°
Swivel angle IPX4 approx. ± 180° -10°
Dimensions:
External dimensions with control cabinet (D x W x H) approx. 1000 x 1350 x 1,900 mm
External (D x W x H) approx. 1000 x 1000 x 1,900 mm
Internal dimensions (D x W x H) 400 x 650 x 750 mm
Data for operation
Voltage: 3/N/PE AC 400V ±10% 50hz
Rated power 1.5 KW
Rated current 6.0 A
Weight: 375 kg
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Climate test chamber Temp. -70 to 180°C
Weiss explosionsgeschütztWK-600/70 (I)-(II) 2 G EEx
Call
Condition: excellent (used), Weiss
Type: WK-600/70 (I)-(II) 2 G EEx /22605147
Weiss climate chamber water-cooled
(test room explosion-proof)
INERTIZATION WITH NITROGEN / EXPLOSION-PROOF TEST ROOM
Technical data:
Test chamber designation: WK-600/70 (I)-(II) 2 G EEx
External dimensions with hinges and door lock
Height 1995 mm, width 1090 mm, depth 1660 mm
External dimensions without hinges and door lock
Height 1995 mm, width 1000 mm, depth 1660 mm
Test room capacity: approx. 600 liters
Cold / heat operation -70 to 180°C
Climate operation 10 – 95°C
Humidity 10...98% r. H.
Temperature change per time
Cooling approx. 2.5 K/min
Heating approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 14 kW
Ppodpfov Ewy Hox Ak Dsr
Rated current: 25 A
On-site fuse: 32 A slow-blow
Permissible test item weight
Total load of the grate supports 80 kg
Test room floor 80 kg, grate insert 40 kg
Weight: 800 kg
Refrigerant: R 404A/R 23
(The air conditioning system's evaporator has been replaced)
For your safety as a buyer, the following information! The following points are carried out in advance on the chambers we offer:
1. Functional check and replacement of necessary components
2. If necessary, new filling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Temperature test chamber spraying device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in steady state
according to IEC 60068-3-5 dependent on the test chamber temperature
over time ± 1 K
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the insert grid
Water level = 0 mm
The water level is at the top edge of the insert grid
Data for standard spray device
Number of spray nozzles: 6
Spray volume per nozzle: 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles: 6
Spray volume per nozzle: 4.5 l/min
Additional flooding nozzles: 2
Spray volume of additional nozzle: 6 l/min
Compressed air consumption: approx. 3 m³/h
Data for water tank with pre-temperature control
Volume: approx. 2000 l
Pjdpfxswc Nvge Ak Dspr
Temperature range for pre-temperature control +5°C to +40°C
Temperature change duration
Cooling of +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Installation and Operation Data:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Plug-ins
1 50 mm diameter plug installed on the left
Test chamber capacity: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Nominal voltage 3/N/PE AC 400V ± 10% 50Hz
Nominal power approx. 26 kW
Nominal current approx. 44.0 A (neutral conductor loaded)
Fuse protection 63 A gG, on-site
Weight approx. 890 kg net
For your safety, please note the following information!
The following steps are carried out on our chambers in advance:
1. Functional testing and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Temperature cabinet
VötschVTS 7011-5
Call
Condition: good (used), Vötsch
Type: VTS 7011-5
Pjdoum Uzmopfx Ak Djpr
Heraeus Vötsch temperature chamber, water-cooled
Test chamber volume 110 liters
Test chamber dimensions: Width 560 mm Depth 350 mm Height 630 mm
External dimensions: Width 850 mm Depth 1030 mm Height 1640 mm
Temperature range - 70°C to +180°C
Temperature deviation in time ± 0.3 to 1 K
Spatial temperature deviation ± 0.5 to ± 2 K
Temperature change rate cooling 6 K/min
Temperature change rate heating 10 K/min
Refrigerant: R-404 A / R 23
Voltage 3/N/PE AC 400V±10% 50Hz
Rated power 7.5 kW
Rated current 13 A
Weight: 360 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, refilling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Ppedpfx Asun Rv Nek Der
Heraeus Vötsch temperature test chamber water-cooled
Temperature range -70°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5 K
Temperature deviation in terms of time ± 0.5 to ± 2.0 K
Temperature change rate cooling 5.0 K/min
Temperature change rate heating 6.5 K/min
Heat compensation +20°C 3000 W
Thermal compensation -20°C 3000 W
Test chamber dimensions: Width 580 mm Depth 765 mm Height 750 mm
External dimensions: Width 870 mm Depth 1595 mm Height 1775 mm
Test chamber volume 335 liters
Rated voltage: 3/N/PE AC, 400V ±10 %, 50Hz
Rated power: 10 kW Rated current: 21 A
Sound level at 1m distance (free-field measurement) < 69dB (A)
Lateral feed-through 5.5 cm / 12.5 cm
Cabinet is water-cooled
Refrigerant: R- 404A and R 23
Weight approx. 570 kg
The following information for you as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. refilling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Climatic test chamber -70°C to +180°C
VötschVCS 7034-5 - 335 Liter
Call
Condition: used, Vötsch
Type: VCS 7034-5
Water-cooled climatic test chamber
Test chamber capacity 335 liters
Performance for temperature tests
Temperature range -70 to +180°C
Temperature deviation in time K ±0.1 to ±0.5
Spatial temperature deviation K ±0.5 to ±2.0
Temperature gradient 1 to 4
Rate of change :
Cooling 6.7 K/min
Heating 6.8 K/min
Heat compensation at +20 °C 3000 W / at -20°C 3000 W
Temperature calibration values +23 °C and +80 °C
Performance for climate tests
Temperature range +10 to +95°C
Temperature deviation in time ±0.1 to ±0.3 K
Spatial temperature deviation ±0.5 to ±1.0 K
Temperature gradient 1 to 2 K
Humidity range 10 to 98%
Ppjdpfx Aeuxq T Dok Dsr
Humidity deviation in time ±1 to ±3%
Dew point range -3 to +94°C
Heat compensation 400W
Climate calibration values +23 °C / 50 % r.h. and +95 °C / 50 % r.h.
Test chamber dimensions: Width 580mm Depth 765mm Height 750mm
External dimensions: Width 870mm Depth 1595mm Height 1775mm
Electrical connection: 3/N/PE AC, 400 V ±10% 50 Hz
Rated power: 10kW
Rated current: 21 A
Sound pressure level: 64dB(A)
Cooling water consumption: 1.4m³/h
Refrigerant: R-404A / R-23
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Shock test chamber
VötschVT 7012 S3
Call
Condition: excellent (used), Vötsch shock test chamber
Here we offer you a Vötsch shock test chamber.
Water cooled
Temp. range -80C to +220C
Hot chamber +50 to +220
Medium chamber -10 to +90
Cold chamber -80 to +70
Mains voltage 400V +-10% 3/N 50Hz
Rated current 30.5 A
Rated power 13.5 KW
Refrigerant VK : R 404A 3.00kg p*: 25bar
Refrigerant TK : R23 15bar p* : 25 bar
Condition: used / used
Type: VT 7012 S3
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Psdpfx Asn Avcujk Djpr
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Temperature chamber
WEISSWT11-1000/40
Call
Condition: excellent (used), Weiss temperature chamber
Here we offer a Weiss temperature chamber.
Weiss temperature chamber air cooled with Weiss condenser cooler
Test chamber capacity approx. 990 liters
Data for temperature tests:
Temperature range -40°C to +180°C
Temperature deviation in time in center of chamber ± 0,1 to ± 0,5 K
Temperature deviation spatially ± 0.5 to ± 2.0 K
Temperature gradient (acc. to IEC 60068-3-5) 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating 4 K/min
Cooling 3 K/min
Heat compensation max. 4500 W
Feedthrough built into basic equipment
R1: NW 125 mm
L1: NW 50 m
Pjdpfx Ajp Dun Usk Djpr
Dimensions:
Test chamber dimensions: Width 1100 mm x depth 950 mm x height 950 mm
Housing dimensions: width 1390 mm x depth 1525 mm x height 1995 mm
maximum load (evenly distributed over the surface) of the test chamber floor 150 kg
per insert grate 50 kg
total load of the grate supports 100 kg
Data for operation:
Test room lighting halogen bulb 24V, 50W
Rated voltage 3/N / PE AC 400 V ± 10% 50 Hz
Rated power 11,5 kW
Rated current 22 A
Heat output water-cooled test chambers max. heat output to environment 1.3 kW
Noise measurement:
Sound pressure level approx. 64 dB(A)
Refrigerant: ( converted to R-452a )
weight: approx. 840 kg
Type: WT11-1000/40
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Temperature test chamber
WEISSWT-600/70
Call
Condition: excellent (used), Weiss temperature test chamber
Here we offer a temperature test chamber.
Weiss temperature test chamber water cooled
Technical data:
Test cabinet designation: WT-600/70
Outer dimensions with hinges and door lock
height 1995 mm, width 1090 mm, depth 1660 mm
Outer dimensions without hinges and door lock
height 1995 mm, width 1000 mm, depth 1660 mm
Internal dimensions:
Height 950 mm, width 800 mm, depth 800 mm
Test chamber capacity: approx. 600 liters
cold / heat operation -70°C to 180°C
Psdpfx Asiqk Absk Depr
Temperature change per time
cooling approx. 2.5 K/min
Heating up approx. 4 K/min
3/N/PE AC 400V ±10% 50Hz
Rated power: 9.1 kW
Rated current: 19 A
Fuse on site: 32 A slow blow
Permissible test material weight
Total load of grate supports 80kg
test chamber floor 80kg, insert grate 40kg
Refrigerant: R 404A/R23
Weight: 675kg
Type: WT-600/70
For you as a buyer for safety the following information!
The following points are carried out on our offered chambers in advance:
1. functional check and exchange of necessary components
2. new filling with legally compliant refrigerant
3. after successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used / used
Scope of delivery: (See picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Temperature shock test chamber
Weiss130 Liter TS 130 *
Call
Condition: excellent (used), Here we offer a temperature shock test cabinet.
White Temperature Shock Test Cabinet Air Cooled
Specification:
Temperature range hot chamber +60°C ... +220°C
Temperature range cold chamber -10°C ... -80°C
Change hot/cold chamber 10 s
Temperature constancy ±1 K
Pedpslgux Aofx Ak Dspr
Dimensions and other data:
External dimensions: Height 1990 mm
Width ( without and with door hinge ) without....approx. 1820 mm with....approx. 1850 mm
Depth ( without and with test room door ) without....ca. 900 mm with....ca. 1155 mm
Dimensions of the lifting basket ( test chamber ) height 450 mm, width 500 mm, depth 600 mm
volume 130 liters
Test space load max. 20 kg
Test chamber floor load max. 20 kg
Cooling water pressure min. 2 ... max. 6 bar
Max. Backup fuse 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of unit approx. 65 dB(A)
Cooling cascade water cooled
Connected load: 3/N/PE/AC 400V ±10% 50Hz /14,0 kW
nominal current 26,0 A
Refrigerant R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used / used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
Further questions we can answer on the phone for you.
Listing
Borken
18,513 km
Temperature test chamber 270 liters
VötschVTS³ 7027-25 -72°C bis +180°C
Call
Condition: excellent (used), Vötsch
Type: VTS³ 7027-25
Heraeus Vötsch temperature test chamber, water-cooled
Performance data:
With temperature change rate of 25 K/min
Test chamber dimensions Height 750 mm Width 580 mm Depth 615 mm
External dimensions Height 1775 mm Width 780 mm Depth 1895 mm
Ppjdpfxetz Rqms Ak Der
Temperature range -72°C to + 180°C
Temperature deviation temporal ± 0.1 to ± 0.5
Temperature homogeneity in space ± 0.5 to ± 2.0
Temperature change rate cooling 25 K/min
Temperature change rate heating 25 K/min
Heat compensation at -20 °C 8000 W
Heat compensation at +20 °C 8000 W
Test volume: 270 liters
2x lateral feed-through ∅ 125 cm
1x side feed-through ∅ 50 cm
Cabinet is water-cooled
Test room lighting:
LED strip 24 V, 6.8 W / 2x halogen bulb 24 V, 50 W
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal power: 26 KW
Rated current: 44 A
Refrigerant: R-452A and R-23
Weight: approx. 980 kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Climate chamber
WEISSWK1-1000/70
Call
Condition: good (used), White
Type: WK1-1000/70
Weiss climatic test chamber water-cooled
(refrigerant converted to R-452A)
Touch panel" control unit
All control and operating commands can be triggered by simply touching the function icons on the
all control and operating commands by simply touching the function icons.
Feedthroughs
The test chamber is equipped with feed-throughs on the right and left side.
Measurement cables and test equipment can be routed into the test chamber through these.
Feed-throughs:
1 feed-through ∅ 125 mm installed on the right
Ppsdpfxsrvx Ezs Ak Dsr
1 feed-through ∅ 50 mm installed on the left
Volume 990 liters
Test chamber dimensions:
Test chamber: width 1100 mm, depth 950 mm, height 950 mm
Housing: width 1385 mm, depth 1850 mm, 1980 mm
Data for temperature tests:
Minimum temperature -70 °C
Maximum temperature +180 °C
Temperature deviation, temporal ± 0.1 to ± 0.5 K
Temperature homogeneity, spatial ± 0.5 to ± 2 K
Temperature change rate, heating 4 K/min
Temperature change rate, cooling 2.5 K/min
Max. heat compensation 2750 W
Data for climate tests:
Temperature range +10°C to +95°C
Humidity range 10 to 98% r.h.
Temperature deviation, temporal ± 0.1 to ± 0.3 K
Temperature homogeneity, spatial ± 0.5 to ± 1 K
Humidity deviation, temporal ± 1 to ± 3% r.h.
Data for operation:
Rated voltage: 3/N/PE AC 400V ±10% 50Hz
Nominal current: 29A Nominal power 19.8 kW
Refrigerant: R-452A/ R23
Weight approx. 910kg
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Temperature cabinet 335 liters
WeissWT3-340/70 -72°C bis +180°C
Call
Condition: excellent (used), Here we offer a Weiss temperature cabinet.
Weiss temperature cabinet With S!MCON / 32 control Air-cooled
(refrigerant converted to R-452A)
Test chamber capacity: approx. 335 liters
Test chamber dimensions: Height 750 mm, width 580 mm, depth 765 mm
External dimensions: Height 1775 mm, width 870 mm, depth 1600 mm
Data for operation:
Test room lighting Halogen bulb 24V, 50W
Nominal voltage: 3/N / PE AC 400 V ± 10% 50 Hz
Rated current: 12.5 A Rated power 4.1 kW
On-site fuse 16 A slow-blow
Sound pressure level approx.
measured at a distance of 1 m from the front. 1m height 58 dB(A)
Data for temperature tests:
Temperature range: -72 to +180 °C
Temperature deviation in time in the center of the usable space: ± 0.1 to ± 0.5 K
Spatial temperature deviation: ± 0.5 to ± 1.5 K
Temperature gradient
(according to IEC 60068-3-5): 1 to 4 K
Temperature change rate (according to IEC 60068-3-5)
Heating: 3.0 K/min
Cooling: 3.0 K/min
Heat compensation max. 1500 W
Refrigerant: R-452A / R-23
Weight: 585 kg
Type: WT3-340/70
The following information is for your safety as a buyer!
The following points are carried out on our offered chambers in advance:
1. functional check and replacement of necessary components
2. if necessary, new filling with legally compliant refrigerant
3. leak test with certificate
Podpjq U Sdnjfx Ak Dopr
4. after successful inspection, the chambers are subjected to a documented test run.
Condition: used
Scope of delivery: (see picture)
(Changes and errors in the technical data, specifications are reserved!)
We will be happy to answer any further questions you may have on the phone.
Listing
Borken
18,513 km
Climate test chamber with humidity 190 liters
VötschVC 7018 -70 bis 180°C
Call
Condition: excellent (used), Vötsch
Type: VC 7018
Vötsch Climatic Test Chamber VC 7018 Water-Cooled
Touch Panel Control Unit
On the touch panel control unit, all control and operating commands can be triggered by simply touching the function symbols.
Ppjdpfx Aswgaykok Djr
Adjustable Feet
To compensate for uneven floors and ensure adequate ventilation of the machine section,
the test chamber is equipped with adjustable feet.
Ports
The test chamber is equipped with port holes on the right and left sides.
These allow measurement cables and test equipment to be routed into the test chamber.
Feedthrough included in standard equipment
R1: NW 125 mm
L1: NW 50 mm
Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm
Housing dimensions: Width 870 mm x Depth 1280 mm x Height 1745 mm
Characteristics for temperature tests:
Temperature range: -70°C to +180°C
Temperature ±0.1 to ±0.5 K
Spatial ±0.5 to ±2.0 K
Temperature change rate according to IEC 60068-3-5
Heating: 4 K/min
Cooling: 2.3 K/min
Characteristics for climatic tests:
Temperature range: -10°C to +95°C
Humidity range: 10% to 98% r.h. F.
Temperature deviation over time in the center of the usable space ± 0.1 to ± 0.3 K
Temperature deviation over space ± 0.5 to ± 1.0 K
Temperature gradient 1 to 2 K
Humidity deviation over time in the center of the usable space ± 1 to ± 3 %RH
Electrical connection:
Nominal voltage: 3/N/PE AC 400V ±10 50Hz
Nominal power: 5.9 kW
Nominal current: 12.0 A
Connection cable: 3.5 m
Fuse protection: 16 A slow-blow, provided by the customer
Refrigerants: R-404A and R-23
Test chamber capacity: approx. 190 liters
Weight: approx. 460 kg net
For your safety, the following information is provided as a buyer!
The following steps are performed on our offered chambers in advance:
1. Functional testing and replacement of necessary components
2. Refilling with legally compliant refrigerant, if necessary
3. Leak testing with a certificate
4. After successful testing, the chambers are subjected to a documented test run.
Condition: Used
Scope of delivery: (See image)
(Subject to change and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
18,513 km
Climatic test chamber 800 L, -55°C to +180°C
WeissClimeEvent C/800/55a/25/S 25K/min
Call
Year of construction: 2020, condition: excellent (used), Weiss
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Pjdpow R Rt Iofx Ak Djpr
Temperature range: -55 to +180°C
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
For further questions, we are happy to answer your call.
Listing
Borken
18,513 km
Salt spray chamber / climate cycling device
WeissSC/KWT 450
Call
Condition: excellent (used), White
Type: SC/KWT 450
Salt Spray Chamber
Technical Specifications:
Test chamber capacity: 450 liters
Max. load: 100 kg
Brine storage tank: 180 liters
External dimensions: Height 920 mm, Width 1930 mm, Depth 800 mm
Test chamber dimensions: Height 740 mm, Width 850 mm, Depth 570 mm
Areas of application:
Corrosion tests:
Salt spray test: Room temperature up to +50°C
Condensation test: Room temperature Up to +45°C
Humidifier +75°C
Temperature stability
The temperature deviation over time is ± K.
Voltage: 1/N/PE AC 230V ±10% 50Hz
Rated power 2.0 kW, Rated current 8.7 A
Combination:
Salt spray test SS: DIN 50021
Condensation test KFW: DIN 50017
Normal climate (ventilation): DIN 50014
Weight: 180 kg
Condition: Used
Scope of delivery: (See image)
(Subject to changes and errors in the technical data, information is subject to change!)
We are happy to answer any further questions you may have over the phone.
Ppodpfsw Strcsx Ak Dsr
Listing
Borken
18,513 km
Temperature test chamber -70°C to +180°C
VötschVTS 7018-5 190 Liter
Call
Condition: excellent (used), Vötsch
Model: VTS 7018-5
Podpfxjwq Iymo Ak Dspr
Water-cooled Temperature Test Chamber
System retrofitted with R-452A
Temperature range: -70°C to +180°C
Temporal temperature deviation: ±0.1 to ±0.5 K
Spatial temperature deviation: ±0.5 to ±2.0 K
Temperature change rate cooling: 7.5 K/min
Temperature change rate heating: 7.5 K/min
Heat compensation at +20°C: 3000 W
Heat compensation at -20°C: 3000 W
Test chamber dimensions: Width 580 mm, Depth 450 mm, Height 750 mm
External dimensions: Width 870 mm, Depth 1280 mm, Height 1575 mm
Test chamber volume: 190 liters
Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated power: 10.0 kW, Rated current: 21 A
Main fuse (on-site): 32 A slow-blow
Sound level at 1m distance (free-field measurement): < 69dB (A)
Side port: 50 mm / 125 mm
Chamber is water-cooled
Refrigerants: R-452A and R 23
Weight approx. 460 kg
For your safety as a buyer, the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If required, new charging with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented trial run.
Condition: used
Scope of delivery: (See picture)
(Technical data may be subject to change or error!)
If you have any further questions, we will be happy to answer them by phone.
Listing
Borken
18,513 km
Climate test chamber 1300 liters with humidity control
VötschVCS 7130-15 -70°C bis +180°C
Call
Condition: good (used), Vötsch
Model: VCS 7130-15
Vötsch Climate Test Chamber, Water-Cooled
Temperature Test Data:
Temperature range: -70°C to 180°C
Temporal temperature deviation at center of workspace: ±0.3 to ±0.8 K
Spatial temperature deviation: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 16 K/min
Cooling: 14.5 K/min
Ppjdpfxswvgwbj Ak Der
Climate Test Data:
Temperature range: +10°C to +95°C
Humidity range: 10 to 98% RH
Temporal temperature deviation at center of workspace: ±0.1 to ±0.3 K
Spatial temperature deviation: ±0.5 to ±1 K
Temperature gradient: 1 to 2 K
Temporal humidity fluctuation at center of workspace: ±1 to ±3% RH
Maximum heat compensation: 8000 W
Enclosure dimensions:
External dimensions with hinges and door lock:
Height: 1995 mm, Width: 1680 mm, Depth: 1855 mm
External dimensions without hinges and door lock:
Height: 1995 mm, Width: 1300 mm, Depth: 1855 mm
Internal dimensions:
Height: 950 mm, Width: 1100 mm, Depth: 950 mm
Test chamber volume: approx. 1300 liters
Feedthroughs:
The test chamber is equipped with feedthroughs on both the right and left sides. These allow for test leads and testing devices to be routed into the chamber.
1 x R1 NW 125 mm
1 x R1 NW 140 mm
1 x L1 NW 50 mm
Test chamber illumination:
Halogen bulb 24V, 50W
Power supply: 3/N/PE AC 400V ±10% 50Hz
Rated power: 44.0 kW
Rated current: 63.0 A
Customer-provided fuse: 100 A slow-blow
Maximum heat output to the environment: 2.2 kW
Permissible test item weight:
Total load on shelf supports: 100 kg
Test chamber floor: 150 kg, Removable shelf: 50 kg
Refrigerants: R 404A/R 23
Weight: 1900 kg
For your security as a buyer, please note:
The following steps are carried out in advance on our chambers offered for sale:
1. Functional check and replacement of necessary components
2. If necessary, refill with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Subject to changes and errors in the technical data and specifications!)
We are happy to answer any further questions by phone.
We make it easier for you to find: "vötsch/weiss gtts 220"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month