Description
CTS
Type: C-40/350 Ex/l
Climate Test Chamber, Water-Cooled
ATEX Zone 1
The Ex/l designation indicates that this climate test chamber is suitable for use in hazardous areas classified as Zone 1. This means it is designed for environments where explosive atmospheres may occur. Such equipment is specially constructed and tested to ensure safety in these conditions.
Temperature Testing:
Temperature range: -40°C to +180°C
Temperature deviation: ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5:
Heating: 3.5 K/min
Laedpfjwvr H Uox Agrsi
Cooling: 4 K/min
Heat compensation:
approx. 3500 W at +20°C
approx. 2000 W at -20°C
Climate Testing:
Temperature range: +10°C to +90°C
Humidity range: 10% to 95% relative humidity
Dew point range: +5°C to 78°C
Temperature deviation: ≤ 1.0 K over time
Humidity deviation: ≤ ±3.0% r.h. over time
The technical data refer to an ambient temperature of +25°C, nominal voltage of 400V, without test specimen, without heat compensation, and without additional equipment. Options may affect performance data.
Technical Design:
Cooling unit:
water-cooled, low-noise, fully hermetic, infinitely variable power adjustment via electronic monitoring and control system, environmentally friendly refrigerant R404A
Test chamber: Floor load capacity 150 kg/m²
Rack: Stainless steel,
support surface 620 x 600 mm
Load per rack max. 35 kg
Total load with maximum rack configuration 100 kg
Control system:
32-bit controller
LCD operating panel
Digital display of setpoint and actual values
Numeric input of setpoints
Plain text fault messages
RS 232 interface
Ethernet interface
Free switching channels for user-side test item control
Dimensions:
Test volume: 350 liters
Internal dimensions: Height 750 mm × Width 650 mm × Depth 720 mm
External dimensions: Height 1800 mm × Width 850 mm × Depth 1640 mm
Operating Data:
Electrical connection: 400V +6/-10%, 3/N, 50 Hz
Nominal power: 7.15 kW
Nominal current: 14.3 A
Protection class: IP 54
Sound pressure level
The listing was translated automatically. Translation errors are possible.
Type: C-40/350 Ex/l
Climate Test Chamber, Water-Cooled
ATEX Zone 1
The Ex/l designation indicates that this climate test chamber is suitable for use in hazardous areas classified as Zone 1. This means it is designed for environments where explosive atmospheres may occur. Such equipment is specially constructed and tested to ensure safety in these conditions.
Temperature Testing:
Temperature range: -40°C to +180°C
Temperature deviation: ≤ ±0.3 K over time
Temperature change rate according to IEC 60068-3-5:
Heating: 3.5 K/min
Laedpfjwvr H Uox Agrsi
Cooling: 4 K/min
Heat compensation:
approx. 3500 W at +20°C
approx. 2000 W at -20°C
Climate Testing:
Temperature range: +10°C to +90°C
Humidity range: 10% to 95% relative humidity
Dew point range: +5°C to 78°C
Temperature deviation: ≤ 1.0 K over time
Humidity deviation: ≤ ±3.0% r.h. over time
The technical data refer to an ambient temperature of +25°C, nominal voltage of 400V, without test specimen, without heat compensation, and without additional equipment. Options may affect performance data.
Technical Design:
Cooling unit:
water-cooled, low-noise, fully hermetic, infinitely variable power adjustment via electronic monitoring and control system, environmentally friendly refrigerant R404A
Test chamber: Floor load capacity 150 kg/m²
Rack: Stainless steel,
support surface 620 x 600 mm
Load per rack max. 35 kg
Total load with maximum rack configuration 100 kg
Control system:
32-bit controller
LCD operating panel
Digital display of setpoint and actual values
Numeric input of setpoints
Plain text fault messages
RS 232 interface
Ethernet interface
Free switching channels for user-side test item control
Dimensions:
Test volume: 350 liters
Internal dimensions: Height 750 mm × Width 650 mm × Depth 720 mm
External dimensions: Height 1800 mm × Width 850 mm × Depth 1640 mm
Operating Data:
Electrical connection: 400V +6/-10%, 3/N, 50 Hz
Nominal power: 7.15 kW
Nominal current: 14.3 A
Protection class: IP 54
Sound pressure level
The listing was translated automatically. Translation errors are possible.
Seller
Note: Register for free or log in, to access all information.
Registered since: 2012
Send inquiry
Telephone & Fax
+49 2861 ... show
These listings may also fit your interest.
Listing
Haiger
18,535 km
Machining center
DMG MORICMX 600 V
DMG MORICMX 600 V
Listing
品川区
9,242 km
5-axis Vertical Machining center
DMGDMU80 monoBLOCK
DMGDMU80 monoBLOCK
Listing
Schloß Holte-Stukenbrock
18,424 km
Machining center
Droop & ReinModimill
Droop & ReinModimill
Listing
Butzbach
18,532 km
Machining center
Starrag-HeckertHEC500D
Starrag-HeckertHEC500D
Listing
Kaufungen
18,422 km
Universal machining center
Deckel MahoDMU 80 monoblock
Deckel MahoDMU 80 monoblock
Listing
Tatabánya
18,028 km
Surface grinding machine surface grinding
JungHF 50 (2338)
JungHF 50 (2338)
Listing
Sedliště
17,966 km
Machining centre
Deckel MahoDMF 220 Linear
Deckel MahoDMF 220 Linear
Listing
Nauen
18,145 km
Vollrath EWFX 60 dissolver
Dissolver VollrathEWFX 60
Dissolver VollrathEWFX 60
Listing
Ruhla
18,406 km
5-axis milling machine
Deckel MahoDMU 70 eVlin
Deckel MahoDMU 70 eVlin
Listing
Germany
18,608 km
DMG DMU 40 eVo linear, year of manufacture 2012, RefNo 231419
DMG40 eVo linear
DMG40 eVo linear
Your listing has been deleted successfully
An error has occurred