08 Maseveon Station + LC Degassing UnitMasevon Station
Chamber Up-Down + + LC Degassing Unit
08 Maseveon Station + LC Degassing Unit
Masevon Station
Chamber Up-Down + + LC Degassing Unit
Year of construction
2021
Condition
Used
Location
Maasmechelen 

Show images
Show map
Machine data
- Machine type:
- 08 Maseveon Station + LC Degassing Unit
- Manufacturer:
- Masevon Station
- Year of construction:
- 2021
- Condition:
- like new (used)
Price & Location
- Location:
- Breitwaterstraat 22, 3630 Maasmechelen, BE
Call
Machine sale

Have you already listed your used machine?
Sell via Machineseeker without commission.
More about selling machinery
More about selling machinery
Details about the offer
- Listing ID:
- A18885536
- Reference number:
- S-LTD-318
- Update:
- 05.04.2025
Description
1.Introduction:
1. This document describes the functional requirements regarding a;
1.1. LC tray degassing chamber
1.2. LC tray degassing chamber is a (controlled vacuum chamber) in which
an aluminum tray containing LC liquid is degassed in a vacuum
environment during a period of time (i.e. entrapped air is evacuated)
Vacuum profiles;
1.1. Pressure set points adjustable between 1.103 and 1.10-3mBar
1.1.1. Measurement range: 1.103 – 5.10-4
1.2. Time set points adjustable between 1 and 600min per step
1.2.1. Degassing step (D) can be minutes to days
1.3. Evacuation and ventilation rates must be controllable
1.4. The evacuation cycle (A – D) is performed automatically
1.4.1. The vent step (E) must be activated manually (operator)
1.5. Typical degassing profile
2.Interior;
2.1.Stainless steel (aluminum) polished process chamber (inside)
2.1.1. Leak rate to be discussed
2.2. LC-tray (adaptation) drawer to easily (un-)load the LC-tray (no shock/shake
movement allowed), see Section 2 LC-tray dimensions and appendix 1
2.3. LC tray must be level (waterpas) at all times to prevent LC spillage
2.4.Chamber must be easily/quickly accessible for cleaning and/or LC tray
(un)loading
2.5.Chamber inside must be polished for easy cleaning and prevention of
contamination and/or moisture collection
2.6.Monitoring (window) possibility of the degassing cycle i.e. monitoring LC
Fjdpfewam Saex Afiopn
liquid surface behavior in the LC tray
2.7.No process contamination caused by chamber material (-manufacturing)
The listing was translated automatically. Translation errors are possible.
1. This document describes the functional requirements regarding a;
1.1. LC tray degassing chamber
1.2. LC tray degassing chamber is a (controlled vacuum chamber) in which
an aluminum tray containing LC liquid is degassed in a vacuum
environment during a period of time (i.e. entrapped air is evacuated)
Vacuum profiles;
1.1. Pressure set points adjustable between 1.103 and 1.10-3mBar
1.1.1. Measurement range: 1.103 – 5.10-4
1.2. Time set points adjustable between 1 and 600min per step
1.2.1. Degassing step (D) can be minutes to days
1.3. Evacuation and ventilation rates must be controllable
1.4. The evacuation cycle (A – D) is performed automatically
1.4.1. The vent step (E) must be activated manually (operator)
1.5. Typical degassing profile
2.Interior;
2.1.Stainless steel (aluminum) polished process chamber (inside)
2.1.1. Leak rate to be discussed
2.2. LC-tray (adaptation) drawer to easily (un-)load the LC-tray (no shock/shake
movement allowed), see Section 2 LC-tray dimensions and appendix 1
2.3. LC tray must be level (waterpas) at all times to prevent LC spillage
2.4.Chamber must be easily/quickly accessible for cleaning and/or LC tray
(un)loading
2.5.Chamber inside must be polished for easy cleaning and prevention of
contamination and/or moisture collection
2.6.Monitoring (window) possibility of the degassing cycle i.e. monitoring LC
Fjdpfewam Saex Afiopn
liquid surface behavior in the LC tray
2.7.No process contamination caused by chamber material (-manufacturing)