Used Cts Climate Test Chamber 5,500 Liters (5.5 M³) for sale (80,673)
Sort results
- Lowest price Highest price
- Newest listings Oldest listings
- Shortest distance Farthest distance
- Newest year of manufacture Oldest year of manufacture
- Latest update Oldest update
- Manufacturer A to Z Manufacturer Z to A
- Relevance
- Lowest price
- Price
- Highest price
- Price
- Newest listings
- Release date
- Oldest listings
- Release date
- Shortest distance
- Distance
- Farthest distance
- Distance
- Newest year of manufacture
- Year of construction
- Oldest year of manufacture
- Year of construction
- Latest update
- Update
- Oldest update
- Update
- Manufacturer A to Z
- Manufacturer
- Manufacturer Z to A
- Manufacturer
- designation from A to Z
- Description
- designation from Z to A
- Description
- Model from A to Z
- Model
- Model from Z to A
- Model
- Lowest reference
- Ref.No.
- Highest reference
- Ref.No.
- Shortest runtime
- Runtime
- Longest duration
- Runtime
- Relevance
- Relevance
Listing
Borken
18,513 km
Climatic test chamber 800 L, -55°C to +180°C
WeissClimeEvent C/800/55a/25/S 25K/min
Call
Year of construction: 2020, condition: excellent (used), Weiss
Type: C/800/55a/25/S
Year of manufacture: 2020
Weiss ClimeEvent Climate Test Chamber, Water-cooled
Chamber volume: 800 liters
Internal dimensions: Height 950 mm, Width 1100 mm, Depth 800 mm
External dimensions: Height 2015 mm, Width 1415 mm, Depth 3156 mm
Floor load capacity: designed for a maximum load of 250 kg
Specifications for temperature testing:
Temperature range: -55 to +180°C
Temporal temperature fluctuation at chamber center: ±0.1 to ±0.5 K
Spatial temperature deviation (temperature gradient): 0.5 to 2.0 K
Heating rate: 25 K/min
Cooling rate: 25 K/min (down to -45°C)
Heating compensation: max. 8000 W
Specifications for climate testing:
Temperature range: +10 to +95°C
Humidity range: 10 to 98% RH
Climate performance data (excerpt)
Humidity range: 10 to 98% relative humidity (RH)
Humidity deviation (temporal):
At chamber center, in steady-state condition, depending on climatic setting:
±1 to ±3% RH
Temperature deviation (temporal):
At chamber center, in steady-state condition, depending on temperature:
±0.1 to ±0.3 K
Lodpsziiypjfx Ahksrr
Temperature uniformity (spatial):
Relative to the setpoint (in the range > 20% RH):
±0.5 to ±1 K
Operational data:
LED strip: 24 V, 6.8 W / 2 x Halogen lamp 24 V, 50 W
Rated voltage: 3/N / PE AC 400 V ± 10%, 50 Hz
Rated power: 53 kW
Rated current: 87 A
Refrigerant: WT69-R449A
Chamber is equipped with Greenmode
Weight: approx. 2050 kg
Buyer Safety Information!
The following steps are performed on all chambers we offer:
1. Functional inspection and replacement of necessary components
2. Refill with legally compliant refrigerant if required
3. Leak test with certificate
4. Upon successful testing, chambers undergo a documented trial run.
Condition: used
Scope of delivery: (see picture)
(Specifications and technical data are subject to change and error!)
For further questions, we are happy to answer your call.
Listing
Borken
18,513 km
Temperature shock chamber 580 liters
RS-SimulatorenST2K 1000/55 -70°C bis +180°C
Call
Condition: excellent (used), RS-Simulators Temperature Shock System ST2K 1000 / 55
The system was regularly serviced and maintained by the manufacturer until it was decommissioned.
Device Data
Manufacturer: RS-Simulators
Type: ST2K 1000 / 55
Design: Temperature Shock System
Cooling: water-cooled
Description
Used temperature shock system for standard-compliant thermal shock testing.
Suitable for material, component, and reliability testing.
Application in industry, automotive, research, and quality assurance.
System Description
2 separate temperature chambers (hot / cold)
Automatic horizontal test basket transfer
Fast changeover for temperature shock tests
Temperature ranges
Hot chamber: +40 °C to +180 °C
Cold chamber: -70 °C to +100 °C
Time deviation: ±0.8 K
Test chamber
Volume: approx. 580 liters
Internal (W x H x D): approx. 1070 x 680 x 800 mm
Max. load: approx. 150 kg
Power supply
400 V / 3~ / N / PE / 50 Hz
Power: max. 33 kVA
Current consumption: max. 65 A
Media connections
Cooling water: G 1", approx. 3 bar (max. 10 bar)
Cooling water requirement: max. 3.2 m³/h
Cooling water return: unpressurized
Compressed air: NW 7.2, 4–10.5 bar
Dimensions:
External (W x H x D): approx. 2800 x 2400 x 2200 mm
Weight: approx. 2800 kg
Equipment:
Horizontal basket movement
C-rails in the test chamber
Large test basket (>1000 mm)
Observation window
Ledpsy H Igfjfx Ahksrr
Internal lighting
Controller SE-604
Program operation and data logging
RS232 interface
Refrigeration system
Refrigerant: R449A / R23
R449A: approx. 8.0 kg
R23: approx. 2.5 kg
Operating data:
Operating hours: approx. 4,500 hours
Sound level: approx. 67 dB(A)
Environmental conditions
Temperature: +12 °C to +30 °C
Humidity: 25 % to 75 % rel. humidity
Scope of supply:
RS-Simulators Temperature Shock System ST2K 1000 / 55
Scope of supply as shown in the pictures
Functional test
Refrigerant service
Leakage test
Condition: Used.
Condition: see pictures.
Inspection possible by arrangement.
Loading and transport can be organized upon request.
Subject to changes and prior sale.
If you have any questions, please contact us.
Listing
Borken
18,513 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1998, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Year of Manufacture: 1998
TK 09
Ljdpfx Ahouuin Rjkerr
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month
Listing
Borken
18,513 km
Thermal shock test chamber
WeissTS 130 -80/+220°C 130L nur 108,7h
Call
Condition: excellent (used), Weiss TS 130 Temperature Shock Test Chamber
Manufacturer: Weiss Umwelttechnik GmbH
Type: TS 130
Machine Type: Temperature Shock Test Chamber
Test Chamber Volume: approx. 130 liters
Operating Hours: approx. 108.7 hours
For sale is a used Weiss TS 130 temperature shock test chamber with S!MCON/32 control system. The two-chamber system enables rapid temperature changes between a hot chamber and a cold chamber. The test specimen is moved between the chambers using a lift basket.
Suitable for temperature cycling and temperature shock tests, material testing, quality assurance, electronics testing, as well as research and development.
Temperature Data:
Temperature Range Hot Chamber: +60 °C to +220 °C
Temperature Range Cold Chamber: −10 °C to −80 °C
Switching Time between Hot and Cold Chamber: approx. 10 seconds
Temperature Stability: approx. ±1 K
Test Chamber:
Test Chamber Volume / Lift Basket: approx. 130 liters
Dimensions Lift Basket (W × D × H): approx. 500 × 600 × 450 mm
Lodpfxjzp D D Ne Ahkjrr
Maximum Load of Lift Basket: 20 kg
Maximum Load per Insert Shelf: 10 kg
Electrical Data:
Power Connection: 3/N/PE AC 400 V ±10 % / 50 Hz
Rated Power: 14.0 kW
Rated Current according to Nameplate: 26.0 A
Connection: CEE 32 A
Recommended Fuse: 35 A slow-blow
Protection Class: IP20
Refrigeration System:
Refrigerant: R404A, Filling Quantity 2.2 kg
Refrigerant: R23, Filling Quantity 1.2 kg
Maximum Low Pressure: 18 bar
Maximum High Pressure: 25 bar
Standing Pressure: 11 bar
Cooling Water Data:
Water Inlet Pressure: 2–6 bar
Connection: R 1/2 inch
Cooling Water Consumption at Full Load: approx. 0.3–0.6 m³/h
Maximum Particle Size: 40 µm
Dimensions and Weight:
External Dimensions (W × D × H): approx. 1,820 × 900 × 1,990 mm
Width Including Door Hinge: approx. 1,850 mm
Depth Including Removable Door: approx. 1,155 mm
Additional Depth of Removable Touch Panel: max. 170 mm
Weight of Test Chamber without Options: approx. 950 kg
Weight of Separate Cooling Unit: not determined
Equipment:
S!MCON/32 control system with external touch panel
Two-chamber design with lift basket
Viewing window
Adjustable temperature limiter
Digital and analog I/O
RS232 and RS485/RS422 interfaces
Potential-free contact
Connection for external Pt100 sensor
Separate cooling unit as shown in the pictures
SIMPATI 3.0 software and extensive documentation as shown in the pictures
Condition and Scope of Supply:
Used
Operating hour counter shows approx. 108.7 hours.
Optical condition as shown in the pictures.
Scope of supply includes separate cooling unit, software, documentation and accessories, exclusively as shown in the pictures.
Loading and shipping via forwarding agent possible upon agreement.
Subject to changes, errors and prior sale.
Listing
Borken
18,513 km
Temperature Test Chamber -40 to +100°C
FeutronTPK 3403/125
Call
Condition: good (used), Feutron Temperature Test Chamber: -40 to +100°C
Thanks to its robust construction, the Feutron TPK 3403/125 is a workhorse for standardized temperature testing.
The primary areas of application for this model are:
1. Electronics and Component Testing
This is the most common area of application. It focuses on how components react to extreme temperatures:
Functional Testing: Does the circuit board continue to operate flawlessly even at -40°C or +150°C?
Burn-In Testing: Artificial aging of components through continuous operation at high temperatures to induce early-stage failures.
2. Materials Testing
Investigation of physical changes in materials:
Brittleness: Do plastics or rubber seals become brittle in cold conditions?
Deformation: Do composite materials warp when exposed to heat?
Storage Testing: How stably do chemical substances or adhesives behave over extended periods at a constant temperature?
Ledpfx Aoy Nynajhkorr
3. Quality Assurance (QA)
Sample Testing: In-process testing conducted alongside production to ensure that manufacturing output adheres to specified temperature ranges.
Standards Compliance Testing: Conducting tests in accordance with common industry standards (e.g., DIN EN 60068) that prescribe specific temperature profiles.
4. Research & Development
Prototyping: Testing new housing designs or materials under controlled thermal conditions prior to mass production. Manufacturer: Feutron
Model: TPK 3403/125
Temperature Range: -40 to +100°C
Refrigeration System: Air-cooled condenser
Temperature Stability: approx. ±0.1 to ±0.5 K
Usable Chamber Volume: approx. 125 liters
Refrigerant: R22
Operating Pressure: 23 bar
Power Supply: 220/280V-3-50Hz
Input Fuse Rating: 25 A
Protection Class: IP 20
Weight: 480 kg
"Everything from a single source: We would be happy to offer you suitable bank financing for your project."
komplett-konzept.leasingo.de
You can find additional items—both new and used—in our shop!
International shipping costs available upon request!
Listing
Borken
18,513 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer you a temperature shock test chamber.
Weiss Temperature Shock Test Chamber, Air-Cooled
(Compressor has been replaced!)
Specifications:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber switching time: 10 s
Temperature stability: ±1 K
Lrjdpfxozp D Axs Ahker
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with swivel arm): without... approx. 1820 mm, with... approx. 1915 mm
Depth (without and with test chamber door): without... approx. 900 mm, with... approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have by phone.
Listing
Borken
18,513 km
Temperature shock test chamber
WEISSTS 130
Call
Condition: excellent (used), Weiss Temperature Shock Test Chamber
Here we offer a temperature shock test chamber.
Weiss Temperature Shock Test Chamber, Water-Cooled
Specification:
Temperature range, hot chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Hot/cold chamber switching time: 10 sec.
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: Height 1990 mm
Width (without and with door hinge): without… approx. 1820 mm, with… approx. 1850 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lifting platform (test chamber): Height 450 mm, Width 500 mm, Depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz / 14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Lsdpfx Ahjzp D Diekjrr
Type: TS 130
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Temperature shock test chamber
Weiss130 Liter TS 130 *
Call
Condition: excellent (used), Here we offer you a temperature shock testing chamber.
Weiss temperature shock testing chamber, air-cooled
Specification:
Temperature range, warm chamber: +60°C … +220°C
Temperature range, cold chamber: -10°C … -80°C
Changeover time, warm/cold chamber: 10 s
Temperature stability: ±1 K
Dimensions and other data:
External dimensions: height 1990 mm
Width (without and with door hinge): without… approx. 1820 mm, with… approx. 1850 mm
Depth (without and with test chamber door): without… approx. 900 mm, with… approx. 1155 mm
Dimensions of the lifting platform (test chamber): height 450 mm, width 500 mm, depth 600 mm
Volume: 130 liters
Test chamber load: max. 20 kg
Load on the test chamber floor: max. 20 kg
Cooling water pressure: min. 2 ... max. 6 bar
Max. fuse rating: 35 A (plug 32 A CEE)
Lrodpfx Aszp D A Eehkjr
Sound pressure level, 1 m in front of the device: approx. 65 dB(A)
Refrigeration cascade, water-cooled
Connection values: 3/N/PE/AC 400V ±10% 50Hz /14.0 kW
Rated current: 26.0 A
Refrigerant: R 404A / R23
Weight: approx. 950 kg
Type: TS 130
Condition: used
Scope of delivery: (See picture)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Climatic chamber temperature and humidity
EspecPL-3KPH -40°C bis 180°C
Call
Condition: excellent (used), ESPEC Climate Testing Chamber PL-3KPH
Device Data
Manufacturer: ESPEC
Type: PL-3KPH
Design: Climate Testing Chamber
Cooling: Air-cooled
Description
Used climate testing chamber from ESPEC.
Suitable for temperature and humidity testing.
Used in research, development, and quality assurance.
Operating Status
Display: STOP / ready for operation.
Technical Data
Lrsdpfx Ahey H H Iujkjr
Model: PL-3KPH
Test chamber volume: approx. 400 liters
Temperature range: -40 °C to +180 °C
Temperature change rate (heating): approx. 3.4 K/min
Temperature change rate (cooling): approx. 1.7 K/min
Temperature stability (-40 °C to +100 °C): ±0.3 K
Temperature stability (+100.1 °C to +150 °C): ±0.5 K
Temperature stability (+150.1 °C to +180 °C): ±1.0 K
Humidity range: 20 to 98 % RH
Humidity stability: ±2.5 % RH
Dimensions
Internal (W x H x D): 600 x 850 x 800 mm
External (W x H x D): 1010 x 1690 x 1195 mm
Electrical Data
400 V / 3~ / 50 Hz
Refrigeration System
Refrigerant: R404A
Air-cooled (no external water connection required)
Weight approx. 350 kg
Equipment
Touchscreen control panel
Program and constant operation
BTHC temperature and humidity control
Observation window
Stainless steel test chamber
Internal lighting
Cable gland
Overheating protection
Hour meter
Industrial design
Scope of supply
ESPEC Climate Testing Chamber PL-3KPH
Scope of supply as shown in the images
Service before delivery (optional)
Functional test
Refrigerant service
Leakage test
Test run with protocol
Condition
Used.
Condition see images.
Note
Loading and transport can be arranged upon request.
Subject to changes and prior sale.
If you have any questions, please do not hesitate to contact us.
Listing
Borken
18,513 km
Temperature test chamber Climate test
VötschVTR 7033/S
Call
Year of construction: 1997, condition: good (used), Vötsch VTR 7033/S Temperature Test Chamber
Lrodpfx Ahsuuiv Isker
Manufacturer: Vötsch
Type: VTR 7033/S
Item No.: 60885637
Temperature Chamber
Temp. Range: -70°C to +180°C
Line Voltage: 400V
Rated Current: 24A
Rated Power: 9.5 kW
Refrigerant (VK): R 404 A
Refrigerant (TK): R 23
Year of Manufacture: 1997
TK 08
Financing through our bank is also possible.
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs upon request!
Listing
Borken
18,513 km
Climatic chamber
RS-SimulatorenKKC 22/45
Call
Condition: good (used), RS Simulators
Type: Walk-in Climate Simulation Chamber KKC 22/45
Technical specifications:
Temperature range: -40...+120 °C
Ljdpfxjzg Txdo Ahkjrr
Temperature tolerance: +/- 1.5°C
Temperature change rate: 1 K/min
Humidity range:
10...approx. 95% r.h.
Humidity tolerance:
+/- 5.0% r.h.
Dimensions:
Test chamber volume: 22 m³
External dimensions (W x D x H): approx. 2600 mm x 6400 mm x 2800 mm
Test chamber (W x D x H): approx. 2200 mm x 4700 mm x 2300 mm
Door opening (W x H): approx. 2200 mm x 2300 mm
Condition: used
Scope of delivery: (see picture)
(Subject to change and errors in technical data!)
We are happy to answer further questions by phone.
Listing
Wymysłów
17,869 km
Vötsch VT 7004 – climatic chamber / temperature chamber
Vötsch VT 7004 – komora klimatyczna / komora temperaturowaVötsch VT 7004 – komora klimatyczna / komora temperaturowa
Call
Condition: excellent (used), For sale: a Vötsch VT 7004 climate chamber, designed for precise research and testing under controlled temperature conditions. This unit is suitable for use in laboratories, quality control departments, materials research, electronics, and the automotive industry.
The chamber is equipped with an electronic temperature controller, an efficient cooling system, and a forced air circulation system that ensures uniform temperature distribution throughout the working chamber. The interior is made of stainless steel, which facilitates cleaning and ensures high durability.
Technical data:
Manufacturer: Vötsch Industrietechnik GmbH
Model: VT 7004
Year of manufacture: 2000
Device number: 58566024350010
Power supply: 230 V AC, 50 Hz
Rated power: 2.0 kW
Lredpezi U Tnofx Ahkjr
Rated current: 10 A
Refrigerant:
R404A – 0.7 kg
R23 – 0.22 kg
Maximum working pressure: 25 bar
Interior: stainless steel
Electronic temperature controller
Forced air circulation
Door with silicone seal
Lighting and service access port in the chamber
Compact design
Condition:
Used unit.
Visually in good condition.
The chamber is clean and complete.
Sold in the exact condition as shown in the pictures.
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Lrjdjzg Tp Nepfx Ahksr
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature Range: -70°C to +180°C
Temperature Deviation (temporal): ±0.1 to ±0.5 K
Temperature Deviation (spatial): ±0.5 to ±2.0 K
Temperature Change Rate (cooling): 5.0 K/min
Temperature Change Rate (heating): 6.5 K/min
Heat Compensation at +20°C: 3000 W
Heat Compensation at -20°C: 3000 W
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test Chamber Volume: 335 liters
Rated Voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated Power: 10 kW, Rated Current: 21 A
Sound Level at 1m Distance (Free-Field Measurement): < 69dB (A)
Side Feedthrough: 5.5 cm / 12.5 cm
Chamber is water-cooled.
Refrigerant: R-404A and R-23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information:
The following points are carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components.
2. New filling with legally compliant refrigerant.
3. After successful inspection, the chambers are subjected to a test run, which is monitored with calibrated equipment.
Condition: used
Scope of Delivery: (See image)
(Changes and errors in the technical data and information are subject to change!)
We are happy to answer any further questions you may have by phone.
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Test Chamber, Water-Cooled
Temperature Range: -70°C to +180°C
Temporal Temperature Deviation: ± 0.1 to ± 0.5 K
Spatial Temperature Deviation: ± 0.5 to ± 2.0 K
Lredpfozg Tpiex Ahkjr
Temperature Change Rate (Cooling): 5.0 K/min
Temperature Change Rate (Heating): 6.5 K/min
Thermal Compensation at +20°C: 3000 W
Thermal Compensation at -20°C: 3000 W
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test Chamber Volume: 335 liters
Rated Voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated Power: 10 kW, Rated Current: 21 A
Sound Level at 1m Distance (Free Field Measurement): < 69dB (A)
Side Access: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R-404A and R-23
Weight: approx. 570 kg
For your safety as a buyer, please note the following information:
The following steps are performed on our offered chambers in advance:
1. Functional check and replacement of any necessary components
2. Refilling with refrigerants compliant with legal regulations
3. After successful inspection, the chambers undergo a test run, which is monitored with calibrated equipment.
Condition: used
Scope of Supply: (See picture)
(Changes and errors in the technical data are subject to change!)
We will be happy to answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Walk-in climate test chamber
VötschVSKZ 04/120/S
Call
Year of construction: 1996, condition: excellent (used), Vötsch VSKZ 04/120/S Walk-In Climatic Test Chamber
Manufacturer: Vötsch
Type: VSKZ 04/120/S
Temp. Range: -40°C to +120°C
Line Voltage: 400V
Rated Current: 95A
Rated Power: 56 kW
Refrigerant: R 404 A
Year of Manufacture: 1996
External Dimensions: W 2850 x D 4100 x H 3080 mm
SO-01
Financing through our bank is also possible.
Ljdpjuuigyofx Ahkorr
komplett-konzept.leasingo.de
Find more items - new and used - in our shop!
International shipping costs on request!
Listing
Borken
18,513 km
Temperature test chamber 190 L
Heraeus VötschTemp. -70°C bis + 180°C VTS 7018-5
Call
Condition: excellent (used), Heraeus Vötsch Type: VTS 7018-5 Heraeus Vötsch Temperature Test Chamber, Water-Cooled Temperature range: -70°C to +180°C Temporal temperature deviation: ± 0.1 to ± 0.5 K Spatial temperature deviation: ± 0.5 to ± 2.0 K Temperature change rate (cooling): 6.5 K/min Temperature change rate (heating): 7.5 K/min Heat compensation: 4,500 W Test chamber dimensions: Width 580 mm x Depth 450 mm x Height 750 mm External dimensions: Width 870 mm x Depth 1,280 mm x Height 1,575 mm Viewing window: Width 300 mm x Height 540 mm Test chamber volume: 190 liters Rated voltage: 3/N/PE AC, 400V ±10%, 50Hz Rated power: 10 kW Rated current: 21 A Supply-side fuse: 32 A slow-blow Sound level at 1 m distance (free-field measurement): < 63 dB(A) Lateral port: 50 cm / 125 cm Chamber is water-cooled Refrigerants: R452A and R23 Weight: approx. 460 kg Important safety information for buyers: The following procedures are carried out on all chambers offered by us: 1. Functional check and replacement of necessary components 2. If required, refilling with legally compliant refrigerant 3. Leak test with certificate 4. After successful inspection, all chambers are subjected to a documented trial run. Condition: used Scope of delivery: (see photos) (Technical data and specifications subject to change and errors!) If you have further questions, we are happy to provide information by phone.
Lrodpfx Ahjyu Rhgsker
Listing
Borken
18,513 km
Temperature test chamber
VötschVTS 7034-5
Call
Condition: good (used), Heraeus Vötsch
Type: VTS 7034-5
Heraeus Vötsch Temperature Testing Chamber, Water-Cooled
Temperature Range: -70°C to +180°C
Temperature Deviation (Temporal): ± 0.1 to ± 0.5 K
Temperature Deviation (Spatial): ± 0.5 to ± 2.0 K
Temperature Change Rate (Cooling): 5.0 K/min
Temperature Change Rate (Heating): 6.5 K/min
Heat Compensation at +20°C: 3000 W
Heat Compensation at -20°C: 3000 W
Test Chamber Dimensions: Width 580 mm, Depth 765 mm, Height 750 mm
External Dimensions: Width 870 mm, Depth 1595 mm, Height 1775 mm
Test Chamber Volume: 335 Liters
Ledpjzg Tp Aefx Ahkerr
Rated Voltage: 3/N/PE AC, 400V ±10%, 50Hz
Rated Power: 10 kW, Rated Current: 21 A
Sound Pressure Level at 1m Distance (Free-Field Measurement): < 69dB (A)
Side Opening: 5.5 cm / 12.5 cm
Chamber is water-cooled
Refrigerant: R-404A and R-23
Weight: Approximately 570 kg
For your safety as a buyer, please note the following information:
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. Refilling with legally compliant refrigerants
3. After successful inspection, the chambers will be subjected to a test run, which is monitored with calibrated devices.
Condition: used
Scope of Supply: (See Image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
Listing
Borken
18,513 km
Climatic chamber
RS-SimulatorenKKC 22/45L
Call
Condition: good (used), RS Simulators
Type: Walk-in Climate Simulation Chamber KKC 22/45L
Technical Data:
Temperature range: -40...+120 °C
Temperature tolerance: +/- 1.5°C
Temperature change rate: 1 K/min
Humidity range:
10...approx. 95% r.H.
Humidity tolerance:
+/- 5.0% r.H.
Dimensions:
Ledpfx Aozg Txkehkerr
Test chamber volume: 22 m³
External dimensions (W x D x H): approx. 2600 mm x 6400 mm x 2800 mm
Test chamber (W x D x H): approx. 2200 mm x 4700 mm x 2300 mm
Door opening (W x H): approx. 2200 mm x 2300 mm
Year of manufacture: 2009
Technical data for solar simulation:
Control module: Mitronic STB1-8
Number of lamps: 8
Ballast unit: Mitronic CP2k5 – 2ZS
Ignition unit: Hönle
Lamp type: OSRAM Powerstar HQI 2000W W/D/S
Condition: used / second-hand
Scope of delivery: (see image)
(Specifications subject to change and errors excepted!)
For further questions, feel free to contact us by phone.
Listing
Borken
18,513 km
Temperature test chamber spray device
VötschVBT 03/500 500 Liter -30 bis 80°C
Call
Condition: excellent (used), Vötsch
Type: VBT 03/500
Lsdpfx Ahjzh D S Reksrr
Air-cooled
Temperature test chamber with spray device
Technical description:
Data for temperature tests without water:
Temperature range -30°C to +80°C
Temperature deviation in the stabilized state
according to IEC 60068-3-5, depending on the test chamber temperature
± 1 K over time
Temperature change rate according to IEC 60068-3-5
Heating: approx. 2 K/min.
Cooling: approx. 2 K/min.
Data for temperature tests with water
Temperature range +5°C to +80°C
Possible water level -10 mm to 540 mm
Water level = -10 mm
The water level is below the support grid
Water level = 0 mm
The water level is at the top edge of the support grid
Data for spray device, standard
Number of spray nozzles 6
Spray volume per nozzle 0.5 l/min
Data for spray device according to EN 539-2, Method B
Number of spray nozzles 6
Spray volume per nozzle 4.5 l/min
Additional flooding nozzles 2
Spray volume additional nozzle 6 l/min
Compressed air consumption approx. 3 m³/h
Data for water tank with preheating
Volume approx. 2000 l
Temperature range for preheating +5°C to +40°C
Temperature change duration
Cooling from +18°C to +5°C approx. 15 h
Heating from +15°C to +40°C approx. 10 h
Data for installation and operation:
Test chamber: Width 1120 mm, Depth 840 mm, Height 540 mm
Housing: Width 2700 mm, Depth 1300 mm, Height 1575 mm
Water tank: Width 1100 mm, Depth 800 mm, Height 2200 mm
Feedthroughs
1 feedthrough ∅ 50 mm, installed on the left
Test chamber volume: approx. 500 liters
Refrigerant R-404a
Electrical connection:
Rated voltage 3/N/PE AC 400V ± 10% 50Hz
Rated power approx. 26 kW
Rated current approx. 44.0 A (neutral conductor loaded)
Fuse 63 A gG, on-site
Weight approx. 890 kg net
For your safety as a buyer, the following information!
The following points will be carried out on our offered chambers in advance:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers will be subjected to a documented test run.
Condition: used
Scope of supply: (See picture)
(Changes and errors in the technical data and specifications are subject to change!)
We will gladly answer any further questions you may have over the phone.
Listing
Borken
18,513 km
Walk-in climate simulation chamber
TIRAKB 127 TCZ 4022 S -2K -40 bis +140°C
Call
Condition: excellent (used), TIRA
Type: TCZ 4022 S -2K
Description: Air-cooled climate simulation chamber
System Structure:
The unit consists of the following main assemblies:
- Walk-in, insulated chamber
- Air handling room
- Humidification system
- Machinery room
- Control cabinet
Technical Data:
Performance Range for Temperature Testing:
- Temperature range: -40...+140°C
- Temperature stability, in supply air (temporal): ≤ ±0.5°C (without thermal test chamber load, according to DIN 50011 T13 / EN 60068)
- Temperature stability, in supply air (spatial): ≤ ±1.0°C (without thermal test chamber load, according to DIN 50011 / EN 60068)
- Heating rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
- Cooling rate (per DIN 50011): approx. 2.0 K/min (without thermal test chamber load, per DIN 50011 / EN 60068) or test specimen in the temperature range of -30°C...+85°C
Performance Range for Climate Testing:
- Temperature range: +10...+90°C
- Humidity working range: 10...approx. 95% RH (without thermal test chamber load)
- Dew point temperature range: +5...+89°C (without thermal test chamber load)
- Humidity stability (in supply air, temporal): ≤ ±2.5% RH, measured in supply air
Performance Range for Climate Testing with Heat Compensation:
- Temperature range: +15...+80°C
- Humidity: 15...approx. 80% RH (without thermal test chamber load; with max. 16 kW heat compensation)
- Dew point temperature range: +10...+74°C (without thermal test chamber load)
Dimensions:
- Test chamber (WxDxH): approx. 2260 x 4648 x 2260 mm
- External dimensions (WxDxH): approx. 2660 x 6460 x 2800 mm
- Clear door passage test chamber door (WxH): 2260 x 2260 mm
- Climate module KB 127 (WxDxH): 1700 x 800 x 1400 mm
- Control cabinet (WxDxH): 800 x 500 x 2000 mm
Lrjdpfx Ahjzizk Heker
Design:
- Airflow: Supply air via perforated plate at the rear wall, ceiling area; exhaust air via perforated plate at the rear wall, floor area
- Temperature control: Direct cooling via evaporation of refrigerant in a finned heat exchanger; heating via electric resistance heater
- Dehumidification: Direct dehumidification via refrigerant evaporation in a heat exchanger
- Interior lining: Stainless steel
- Exterior cladding: Galvanized, plastic-coated steel sheet
- Floor: Stainless steel, floor load 15,000 N/m²
- Wheel load (contact area ≥4 cm²): 1,500 N/wheel
- Door: Double-leaf, stainless steel, externally coated with viewing window (WxH): 1000 x 1000 mm
- Test area lighting: 4 spotlights, 500 W each
- Insulation: Dual-layer insulation, 80 mm PUR foam, 120 mm mineral wool
- Refrigeration unit (1 pc): Bitzer 6G-30.2Y
- Refrigerant: R449A
- Refrigeration oil: SEZ 32
- Steam humidifier (1 pc): EDB 40
Color scheme:
- Chamber RAL 9010, white
- Door RAL 9010, white
- Machine unit RAL 7032, pebble grey
- Control cabinet RAL 7032, pebble grey
Weights:
- Total system: approx. 4,900 kg
- Machine set KB 127: approx. 750 kg
- Control cabinet: approx. 120 kg
- Humidification unit: approx. 64 kg
Connections:
- Rated voltage: 400 V +6%/-10%, 3/PE N, 50Hz
- Rated power: 95 kW
- Rated current: 150 A
Listing
Borken
18,513 km
Temperature test chamber 15 K/min
Weiss -70°C +180°CWT-1300/70/15 1340 Liter
Call
Condition: excellent (used), Weiss WT-1300/70/15 Temperature Testing Chamber
Manufacturer: Weiss Umwelttechnik GmbH
Type: WT-1300/70/15
Water-cooled temperature testing chamber with touch panel control for temperature tests in research, development, quality assurance, and industry.
Technical Data
Temperature range: -70 °C to +180 °C
Test chamber volume: approx. 1340 liters
Temperature change rate (heating): 15 K/min
Temperature change rate (cooling): 10 K/min
Temperature deviation (over time): ± 0.1 to ± 0.5 K
Temperature homogeneity (spatial): ± 0.5 to ± 2 K
Test chamber dimensions:
Height 920 mm
Width 1100 mm
Depth 1330 mm
External dimensions:
Height approx. 2050 mm
Width approx. 1300 mm
Depth approx. 3200 mm
Permissible test specimen load:
Test chamber floor: 150 kg
Insert shelf: 50 kg
Electrical Data
Rated voltage: 3/N/PE AC 400 V ±10 % 50 Hz
Rated current: 63 A
Rated power: 44 kW
Lredpeza Dv Ijfx Ahkor
Refrigeration System
Refrigerant R404A: 14.0 kg
Refrigerant R23: 5.4 kg
R404A LP max.: 18 bar
R404A HP max.: 25 bar
R23 LP max.: 19 bar
R23 HP max.: 25 bar
Standing pressure: 18.5 bar
Equipment
Touch panel control
Stainless steel test chamber
Multiple insertion levels
Side access port
Heated door seal
Water-cooled refrigeration unit
CEE connection
CE marking
Weight: approx. 1500 kg
Condition
Used equipment from industrial application.
Optical condition as shown in the pictures.
For the safety of our customers, the following work will be carried out on the offered climate chambers beforehand:
1. Functional check and replacement of necessary components
2. If necessary, refilling with legally compliant refrigerant
3. Leak test with certificate
4. Documented test run after successful inspection
Scope of delivery: see pictures
Shipping or freight transport possible.
Subject to changes, errors and prior sale.
We will be happy to answer any further questions by telephone.
Trust Seal
Dealers certified through Machineseeker

Listing
Borken
18,513 km
Climatic chamber with humidity, -70°C to 180°C
WeissWK11-600/70/5
Call
Condition: excellent (used), Weiss
Type: WK11 - 600/70/5
Weiss Climate Chamber Water-Cooled
The Weiss climate chamber WK11-600/70/5 with approximately 600 liters usable volume is suitable for temperature and humidity testing, as well as for the conditioning of samples and materials in a range from −70 °C to +180 °C.
Simcon/32 - Net controller
Technical Data:
Lrsdpfxezimg Hs Ahkjr
Test chamber designation: WK11-600/70/5
External dimensions with hinges and door lock:
Height 1995 mm, Width 1090 mm, Depth 1660 mm
External dimensions without hinges and door lock:
Height 1995 mm, Width 1000 mm, Depth 800 mm
Internal dimensions:
Height 950 mm, Width 800 mm, Depth 800 mm
Feedthroughs:
2x R1 NW 125 mm ∅
1x L1 NW 50 mm ∅
Test chamber volume: approx. 600 liters
Temperature Test Data:
Temperature range: -70 °C to +180°C
Temporal temperature deviations at the center of usable space: ±0.1 to ±0.5 K
Spatial temperature deviations: ±0.5 to ±2 K
Temperature gradient: 1 to 4 K
Temperature change rate:
Heating: 6 K/min
Cooling: 6 K/min
Heat compensation:
At +20 °C: 5000 W
At -20 °C: 5000 W
Climate Test Data:
Temperature range: +10 to +95 °C
Humidity range: 10 to 98% r. H.
Temporal temperature deviations at the center of usable space: ±0.1 to ±0.3 K
Spatial temperature deviations: ±0.5 to ±1 K
Temperature gradient: 1 to 2
Humidity fluctuation (temporal, center of usable space): ±1 to ±3% r. H.
Heat compensation: 500 W
3/N/PE AC 400V ±10% 50Hz
Rated power: 16.5 kW
Rated current: 29 A
Main fuse (to be provided by customer): 32 A slow-blow
Permissible test material weight:
Total load of racks: 80 kg
Test chamber floor: 80 kg, Insert rack: 40 kg
Weight: 675 kg
Refrigerants: R452A / R23
Important Note:
"The table shown in the photos is not included in the sale."
For your safety as a buyer, please note the following information:
The following points are completed on our offered chambers beforehand:
1. Functional check and replacement of necessary components
2. If required, refilling with legally compliant refrigerant
3. Leak test with certificate
4. After successful inspection, the chambers undergo a documented test run.
Condition: used
Scope of delivery: (see photo)
(Technical specifications subject to change and errors excepted!)
We are happy to answer any further questions over the phone.
Listing
Meiningen
18,424 km
Chamber furnace 1300°C, 60 liters, exhaust hood
ROHDELS 60/13 mit Bentrup Regler
Call
Condition: reconditioned (used), Year of construction: 2017, machine/vehicle number: SN48357, functionality: fully functional, Chamber furnace with exhaust hood, fully refurbished, 12-month warranty, available for immediate delivery
- Max. temperature: 1300 °C
- Internal dimensions (W x D x H): 400 x 400 x 400 mm
- Capacity: 60 liters
- Separate main switch
- 5-sided heating
- Supply and exhaust air with electrically actuated dampers (driven by Belimo actuators)
- Supply air fan with frequency converter, controlled via regulator
- Stainless steel exhaust hood
- Bentrup 507 control system with thyristor control
- Note: Controller language is German only; switching to other languages is not possible!
- Additional drag element Type S for external recording
Ljdpfxjtbq Eqs Ahkerr
- Documentation included
- Net weight: 250 kg
- Power consumption: 18 kW
- Current rating: 26 amperes
- Supply voltage: 3/N/PE 400VAC
- Connection type: prepared for fixed connection, 32 A plug
- Documentation, CE declaration
- Electrically tested and supplied with current DGUV test protocol
Inspection by appointment.
Furnace, furnaces, annealing furnace, industrial furnace, chamber furnace, kiln, curing furnace, tempering furnace, laboratory furnace, hardening furnace, ceramic furnace
Listing
Borken
18,513 km
Climatic chamber
TiraTCZ 4012
Call
Condition: good (used), TIRA
Type: Walk-in Climate Simulation Chamber TCZ 4012 S(m)
Technical Data:
Temperature range: -40...+120 °C
Temperature tolerance: +/- 1.0°C
Temperature change rate: 1 K/min
Humidity range: 10...approx. 95 % rH
Humidity tolerance: +/- 5.0 % rH
Dimensions:
Test chamber volume: 13 m³
External dimensions (W x D x H): approx. 2260mm x 3850mm x 2780mm
Test chamber (W x D x H): approx. 2254mm x 2645mm x 2251mm
Door opening (W x H): approx. 2251mm x 2254mm
Condition: used
Delivery contents: (see picture)
Lrjdozg Tw Hepfx Ahker
(Subject to changes and errors in the technical data!)
For further enquiries, please contact us by phone.
Listing
Borken
18,513 km
Climatic chamber
TiraTTZ 4008
Call
Condition: good (used), TIRA
Type: Walk-in climate simulation chamber TTZ 4008 S(m)
Technical data:
Temperature range: -40 to +120 °C
Temperature tolerance: +/- 1.0 °C
Temperature change rate: 1 K/min
Humidity range:
10…approx. 95% RH
Humidity tolerance:
+/- 5.0% RH
Dimensions:
Test chamber volume: 8 m³
External dimensions (W x D x H): approx. 2410 mm x 3920 mm x 2530 mm
Test chamber (W x D x H): approx. 2002 mm x 2148 mm x 2005 mm
Lredpfx Ahszg Twmskjr
Door opening (W x H): approx. 2002 mm x 2005 mm
Condition: used
Scope of supply: (See image)
(Changes and errors in the technical data are subject to change!)
We would be happy to answer any further questions you may have by phone.
We make it easier for you to find: "cts climate test chamber 5,500 liters (5.5 m³)"
You will receive new offers immediately and free of charge via e-mail
You can easily terminate the search request at any time
This may be of interest to you

Get information now
+44 20 806 810 84
+44 20 806 810 84
List now
*per listing / month



















































































































































































































































